959 resultados para Copper complexes with 2-aminothiazole
Resumo:
Objectives Our main objectives were to investigate the affinity properties of endothelial and muscular α1D-adrenoceptors and to characterize the cross-talk between endothelial α1D- adrenoceptors and β2-adrenoceptors in rat carotid. Methods Relaxation and contraction concentration-response curves for phenylephrine (α1-adrenergic agonist) were obtained in carotid rings in absence or presence of increasing concentrations of BMY7378 (α 1D-adrenergic antagonist), combined or not with increasing concentration of ICI-118,551 (β2-adrenergic antagonist). Schild analysis was used to estimate the affinity constant from pA2 values of BMY7378. Key Findings BMY7378 produced an unsurmountable antagonism on phenylephrine-induced relaxation but a surmountable antagonism on phenylephrine-induced contraction. BMY7378 potency was higher in inhibiting the relaxation than the contraction induced by phenylephrine because the rightward shifts induced by BMY7378 were greater in the relaxation. The apparent pA 2 value for BMY7378 in phenylephrine-induced relaxation was greater than in contraction. When combined with ICI-118,551, BMY7378 yielded a surmountable antagonism on phenylephrine-induced relaxation and presented a pA2 value similar to that obtained in phenylephrine-induced contraction. Conclusions Endothelial α1D-adrenoceptors, which mediates rat carotid relaxation, present high ligand affinity because of the cross-talk with β2-adrenoceptors, which explains the higher potency of phenylephrine in inducing relaxation than contraction and the atypical unsurmountable antagonism produced by BMY7378 on phenylephrine-induced relaxation. © 2013 Royal Pharmaceutical Society.
Resumo:
This study investigated the effect on solubility and release of ternary complexes of sulfamerazine (SMR) with beta-(beta CD), methyl-(M beta CD) and hydroxypropyl-P-cyclodextrin (HP beta CD) using meglumine (MEG) as the ternary component. The combination of MEG with M beta CD resulted the best approach, with an increased effect (29-fold) of the aqueous solubility of SMR. The mode of inclusion was supported by 2D NMR, which indicated that real ternary complexes were formed between SMR, MEG and M beta CD or HP beta CD. Solid state analysis was performed using Fourier-transform infrared spectroscopy (FT IR), differential scanning calorimetry (DSC) and powder X-ray diffraction (XRD), which demonstrated that different interactions occurred among SMR, MEG and M beta CD or HP beta CD in the ternary lyophilized systems. The ternary complexes with beta CD and M beta CD produced an additional retention effect on the release of SMR compared to the corresponding binary complexes, implying that they were clearly superior in terms of solubility and release modulation. (C) 2014 Elsevier B.V. All rights reserved.
Resumo:
Rapidity gaps may provide an adequate signature for electroweak processes at supercolliders, including the production of the Higgs particle. We show how this important issue can be studied in the dijet final states of operating proton-antiproton colliders and present quantitative predictions.
Resumo:
Our goal was to study the use of 2.0-mm miniplates for the fixation of mandibular fractures. Records of 191 patients who experienced a total of 280 mandibular fractures that were treated with 2.0-mm miniplates were reviewed. One hundred twelve of those patients, presenting 160 fractures, who attended a late follow-up were also clinically evaluated. Miniplates were used in the same positions described by AO/ASIF. No intermaxillary fixation was used. All patients included had a minimum follow-up of 6 months. Demographic data, procedures, postoperative results, and complications were analyzed. Mandibular fractures occurred mainly in males (mean age, 30.3 years). Mean follow-up was 21.92 months. The main etiology was motor vehicle accident. The most common fracture was the angle fracture (28.21%). Twenty-two fractures developed infection, for an overall incidence of 7.85%. When only angle fractures are considered, that incidence is increased to 18.98%. Although only 1 patient (0.89%) described inferior alveolar nerve paresthesia, objective testing revealed sensitivity alterations in 31.52% of the patients who had fractures in regions related to the inferior alveolar nerve. Temporary mild deficit of the marginal mandibular branch was observed in 2.56% of the extraoral approaches performed and 2.48% presented with hypertrophic scars. Incidence of occlusal alterations was 4.0%. Facial asymmetry was observed in 2.67% of the patients, whereas malunion incidence was 1.78%. Fibrous union, mostly partial, occurred in 2.38% of the fractures, but only 1 of those presented with mobility (0.59%). Condylar resorption developed in 6.25% of the fixated condylar fractures. Mean mouth opening was 42.08 mm. The overall incidence of complications, including infections, was similar to those described for more rigid methods of fixation.
Resumo:
The methaneseleninate and 1,10-phenanthroline were used as ligands in the synthesis of new lanthanide complexes. The photostability, emission quantum yield (q) and quantum efficiency (eta) of the D-5(0) emitting level of the Eu3+ ion were determined. An energy level diagram was used to establish the most relevant channels involved in the ligand-to-metal intramolecular energy transfer process. The nephelauxetic effect was investigated to assess the covalency of the ligand-metal chemical bond. The values of the experimental 4f-4f intensity parameters, suggest that this ion is in a chemical environment less polarisable than in the case of complexes with beta-diketonates as ligands. (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
The synthesis and structural characterization of a europium complexed fluorene-bipyridine copolymer are described. A level of ion insertion of 80% in molar basis was achieved, and theoretical calculations showed that it required a twist of 179 degrees (49 kJ) between the pyridine units. Spectroscopy data showed that no electronic coupling between the main backbone and the complexation sites had occurred, but these hindered the interchain aggregation observed in the non complexed polymer. Preliminary electroluminescence studies showed that the EL and PL spectra are consistent, and that the ion had a trapping effect in the charge transport. (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
BACKGROUND: Complete arterial CABG is a surgical option to improve long-term results in the treatment of coronary artery disease (CAD). Harvesting of multiple arterial grafts is commonly associated with prolonged operating times and increased trauma. By use of new operative techniques (skeletonized grafts and the T-graft approach), CABG in multivessel CAD is now possible with only 2 grafts. We present our experience in the use of these techniques on a routine basis. METHODS AND RESULTS: Between March 1996 and September 1999, 490 patients (aged 61+/-9 years, 20% female) underwent complete arterial CABG. Left ventricular ejection fraction ranged from 15% to 85% (mean 59+/-15%). Triple-vessel disease was present in 88% of the patients. The incidence of diabetes mellitus was 32% (14% insulin dependent). Either both internal thoracic arteries (ITAs) (23%) or the left ITA and radial artery (77%) were used as conduits. In 85% of the patients, a T graft was created. Mean operating time was 198+/-46 minutes; bypass time, 82+/-25 minutes; and ischemic time, 58+/-22 minutes. Two to 7 (mean 4.1+/-0.9) anastomoses were performed per patient. Perioperative intra-aortic balloon pump was necessary in 12 patients (2.4%). The rate of perioperative myocardial infarction was 1.2%. Sternal complications occurred in 1. 0%, and in-hospital mortality was 2.2%. Postoperative coronary angiography in 172 patients (35%) documented excellent patency rates (left ITA 98.3%, right ITA 96.5%, and radial artery 96.6%). CONCLUSIONS: Complete arterial revascularization in multivessel CAD is possible with the use of only 2 grafts with good perioperative results. This approach allows for complete arterial CABG on a routine basis.
Resumo:
PURPOSE Extended grafting procedures in atrophic ridges are invasive and time-consuming and increase cost and patient morbidity. Therefore, ridge-splitting techniques have been suggested to enlarge alveolar crests. The aim of this cohort study was to report techniques and radiographic outcomes of implants placed simultaneously with a piezoelectric alveolar ridge-splitting technique (RST). Peri-implant bone-level changes (ΔIBL) of implants placed with (study group, SG) or without RST (control group, CG) were compared. MATERIALS AND METHODS Two cohorts (seven patients in each) were matched regarding implant type, position, and number; superstructure type; age; and gender and received 17 implants each. Crestal implant bone level (IBL) was measured at surgery (T0), loading (T1), and 1 year (T2) and 2 years after loading (T3). For all implants, ΔIBL values were determined from radiographs. Differences in ΔIBL between SG and CG were analyzed statistically (Mann-Whitney U test). Bone width was assessed intraoperatively, and vertical bone mapping was performed at T0, T1, and T3. RESULTS After a mean observation period of 27.4 months after surgery, the implant survival rate was 100%. Mean ΔIBL was -1.68 ± 0.90 mm for SG and -1.04 ± 0.78 mm for CG (P = .022). Increased ΔIBL in SG versus CG occurred mainly until T2. Between T2 and T3, ΔIBL was limited (-0.11 ± 1.20 mm for SG and -0.05 ± 0.16 mm for CG; P = .546). Median bone width increased intraoperatively by 4.7 mm. CONCLUSIONS Within the limitations of this study, it can be suggested that RST is a well-functioning one-stage alternative to extended grafting procedures if the ridge shows adequate height. ΔIBL values indicated that implants with RST may fulfill accepted implant success criteria. However, during healing and the first year of loading, increased IBL alterations must be anticipated.
Resumo:
OBJECTIVE To compare speech understanding of the BAHA BP110 and BAHA Intenso sound processors. STUDY DESIGN Prospective experimental study. SETTING Tertiary referral center. PATIENTS Twenty experienced user of osseointegrated auditory implants with conductive or mixed hearing loss. INTERVENTIONS In a first session, half of the participants were fitted with an Intenso, the other half with a BP110. After 1 month of use, aided speech understanding in quiet and in noise was measured, and the other test processor was fitted. One month later, speech understanding with the second sound processor was assessed. MAIN OUTCOME MEASURES Speech understanding in quiet and in noise, with noise arriving either from the front, the rear, or the side of the user with the osseointegrated bone conductor. RESULTS Significant improvements were found for both processors for speech understanding in quiet (+9.6 to +34.8 percent points; p = 0.02 to 0.001) and in noise (+6.2 to +13.8 dB, p < 0.001). No significant differences were found between the 2 devices for speech in quiet. For noise from the rear, subjects were able to understand speech at signal-to-noise ratios which were lower (less favorable) by -5.1 dB (p < 0.001) when compared with the Intenso. CONCLUSION Speech understanding is substantially improved by both devices, with no significant differences between the sound processors in quiet. In noise, speech understanding is significantly better with the BP110 when compared to the Intenso for noise from the rear.
Resumo:
BACKGROUND Urgent consultations for skin disorders are commonly done in different settings. Scarce data exist about the characteristics of these patients. OBJECTIVE The aim of this study was to analyse specific characteristics of patients receiving an urgent consultation at a dermatology department in a university hospital. METHODS We prospectively recorded the data of all patients having had an urgent consultation during a period of 12 months. RESULTS We registered 2,222 urgent consultations. The most frequent diagnoses were eczemas (24.8%), dermatomycoses (5.1%) and dermatitis not otherwise specified (4.8%). The most frequent treatments were topical steroids, emollients, topical antibiotics, systemic antihistamines, antibiotics and virostatics. 2.2% of patients were hospitalized, 78.8% asked for a consultation for a disease lasting less than 4 weeks, and 6.9% presented the same day as the skin disease appeared. CONCLUSIONS This study shows the characteristics of patients receiving an urgent dermatologic consultation. It underlines the need for collaboration between dermatologists, other physicians, general practitioners and nurses.