999 resultados para Consumo de corrente elétrica
Resumo:
This paper presents the development of a boost converter with the possibility of higher gain than the conventional boost converter for applications under similar conditions and increased power. Presents the main concepts involving the boost converter and two variations: the boost converter of three levels and the boost converter interspersed with two converter cells. The breakdown mounting positions, the operating steps, the addressing and the main strengths of each converter in order to check for possible uses in the construction of a prototype joining their main advantages. In the presentation of this converter addresses the operating steps, the equation governing its design, the simulations obtained through software (PSIM), a comparison between the boost converter models studied and the experimental results.
Resumo:
Distributed generation systems must fulfill standards specifications of current harmonics injected to the grid. In order to satisfy these grid requirements, passive filters are connected between inverter and grid. This work compares the characteristic response of the traditional inductive (L) filter with the inductive-capacitive-inductive (LCL) filter. It is shown that increasing the inductance L leads to a good ripple current suppression around the inverter switching frequency. The LCL filter provides better harmonic attenuation and reduces the filter size. The main drawback is the LCL filter impedance, which is characterized by a typical resonance peak, which must be damped to avoid instability. Passive or active techniques can be used to damp the LCL resonance. To address this issue, this dissertation presents a comparison of current control for PV grid-tied inverters with L filter and LCL filter and also discuss the use of active and passive damping for different regions of resonance frequency. From the mathematical models, a design methodology of the controllers was developed and the dynamic behavior of the system operating in closed loop was investigated. To validate the studies developed during this work, experimental results are presented using a three-phase 5kW experimental platform. The main components and their functions are discussed in this work. Experimental results are given to support the theoretical analysis and to illustrate the performance of grid-connected PV inverter system. It is shown that the resonant frequency of the system, and sampling frequency can be associated in order to calculate a critical frequency, below which is essential to perform the damping of the LCL filter. Also, the experimental results show that the active buffer per virtual resistor, although with a simple development, is effective to damp the resonance of the LCL filter and allow the system to operate stable within predetermined parameters.
Resumo:
In recent years the photovoltaic generation has had greater insertion in the energy mix of the most developed countries, growing at annual rates of over 30%. The pressure for the reduction of pollutant emissions, diversification of the energy mix and the drop in prices are the main factors driving this growth. Grid tied systems plays an important role in alleviating the energy crisis and diversification of energy sources. Among the grid tied systems, building integrated photovoltaic systems suffers from partial shading of the photovoltaic modules and consequently the energy yield is reduced. In such cases, classical forms of modules connection do not produce good results and new techniques have been developed to increase the amount of energy produced by a set of modules. In the parallel connection technique of photovoltaic modules, a high voltage gain DC-DC converter is required, which is relatively complex to build with high efficiency. The current-fed isolated converters explored in this work have some desirable characteristics for this type of application, such as: low input current ripple and input voltage ripple, high voltage gain, galvanic isolation, feature high power capacity and it achieve soft switching in a wide operating range. This study presents contributions to the study of a high gain and high efficiency DC-DC converter for use in a parallel system of photovoltaic generation, being possible the use in a microinverter or with central inverter. The main contributions of this work are: analysis of the active clamping circuit operation proposing that the clamp capacitor connection must be done on the negative node of the power supply to reduce the input current ripple and thus reduce the filter requirements; use of a voltage doubler in the output rectifier to reduce the number of components and to extend the gain of the converter; detailed study of the converter components in order to raise the efficiency; obtaining the AC equivalent model and control system design. As a result, a DC-DC converter with high gain, high efficiency and without electrolytic capacitors in the power stage was developed. In the final part of this work the DC-DC converter operation connected to an inverter is presented. Besides, the DC bus controller is designed and are implemented two maximum power point tracking algorithms. Experimental results of full system operation connected to an emulator and subsequently to a real photovoltaic module are also given.
Resumo:
Introdução: O aumento da gordura abdominal e o sedentarismo contribuem para o risco de doença cardiovascular. A utilização de corrente elétrica de baixa intensidade (microcorrente) na região abdominal, associado ao exercício físico, parece ser um método inovador no aumento da taxa lipolítica dos adipócitos abdominais. Objetivos: Analisar os efeitos da utilização da microcorrente associada a um programa de exercícios em indivíduos saudáveis e com doença arterial coronária na gordura abdominal, e ainda, analisar os efeitos de um programa de exercício físico específico realizado no domicílio em indivíduos com doença arterial coronária, na fase de manutenção da reabilitação cardiovascular, na capacidade cardiorrespiratória. Métodos: Foram conduzidos três estudos: Estudo 1, em indivíduos saudáveis, durante 5 semanas (n=42), distribuídos aleatoriamente por quatro grupos experimentais (realizavam microcorrente e exercício físico: grupo 1- frequência 25 a 10Hz, elétrodos transcutâneos, exercício físico após; grupo 2- frequência 25 a 50Hz, elétrodos trancutâneos, exercício físico após; grupo 3- frequência 25 a 10Hz, elétrodos percutâneos e exercício físico após; grupo 4- frequência 25 a 10Hz, elétrodos transcutâneos e exercício físico realizado em simultâneo) e placebo (realizavam apenas exercício físico), onde foram avaliadas medidas de gordura abdominal; Estudo 2, em indivíduos saudáveis, durante uma sessão de microcorrente e exercício físico (n=83), distribuídos aleatoriamente por grupo experimental (realizavam microcorrente e exercício físico) e grupo placebo (realizavam exercício físico), onde foram avaliadas a atividade lipolítica (níveis de glicerol) e a oxidação de ácidos gordos (estimada pelo VO2 e VCO2); Estudo 3, em indivíduos após um ano de evento de síndrome coronária aguda (n=44), distribuídos aleatoriamente em dois grupos experimentais (grupo 1- exercício físico no domicílio; grupo 2- microcorrente e exercício físico no domicílio) e um grupo controlo (cuidados habituais), durante 8 semanas, sendo avaliados a gordura abdominal, o colesterol, a capacidade cardiorrespiratória, os hábitos de atividade física e alimentares e a qualidade de vida. Resultados: No estudo 1, após 5 semanas de intervenção de microcorrente e exercício físico, verificou-se uma redução das medidas de gordura abdominal (p<0,05); No estudo 2 observou-se que uma sessão de microcorrente associada ao exercício físico aumentou a taxa lipolítica, através da medição de glicerol (p<0,05), sem alterações significativas na oxidação de ácidos gordos, durante o exercício. No estudo 3, após as 8 semanas de aplicação de microcorrente associada a um programa de exercícios específicos no domicílio ocorreu uma diminuição significativa na gordura subcutânea (p<0,05). O programa de exercício físico de reabilitação cardiovascular no domicílio, per se, aumentou a capacidade cardiorrespiratória, na fase de manutenção (p<0,05). Não se verificaram alterações do colesterol total, dos hábitos alimentares, da atividade física e da qualidade de vida entre os três grupos. Conclusão: A utilização da microcorrente associada ao exercício físico parece ser um meio coadjuvante ao programa de exercícios, na redução do tecido adiposo abdominal em indivíduos saudáveis e em indivíduos após 1 ano de enfarte agudo do miocárdio. O programa de Reabilitação Cardiovascular no domicílio, em fase de manutenção, demonstrou melhoria da capacidade cardiorrespiratória.
Resumo:
Esta tese incide sobre o desenvolvimento de modelos computacionais e de aplicações para a gestão do lado da procura, no âmbito das redes elétricas inteligentes. É estudado o desempenho dos intervenientes da rede elétrica inteligente, sendo apresentado um modelo do produtor-consumidor doméstico. O problema de despacho económico considerando previsão de produção e consumo de energia obtidos a partir de redes neuronais artificiais é apresentado. São estudados os modelos existentes no âmbito dos programas de resposta à procura e é desenvolvida uma ferramenta computacional baseada no algoritmo de fuzzy-clustering subtrativo. São analisados perfis de consumo e modos de operação, incluindo uma breve análise da introdução do veículo elétrico e de contingências na rede de energia elétrica. São apresentadas aplicações para a gestão de energia dos consumidores no âmbito do projeto piloto InovGrid. São desenvolvidos sistemas de automação para, aquisição monitorização, controlo e supervisão do consumo a partir de dados fornecidos pelos contadores inteligente que permitem a incorporação das ações dos consumidores na gestão do consumo de energia elétrica; SMART GRIDS - COMPUTATIONAL MODELS DEVELOPMENT AND DEMAND SIDE MANAGMENT APPLICATIONS Abstract: This thesis focuses on the development of computational models and its applications on the demand side management within the smart grid scope. The performance of the electrical network players is studied and a domestic prosumer model is presented. The economic dispatch problem considering the production forecast and the energy consumption obtained from artificial neural networks is also presented. The existing demand response models are studied and a computational tool based on the fuzzy subtractive clustering algorithm is developed. Energy consumption profiles and operational modes are analyzed, including a brief analysis of the electrical vehicle and contingencies on the electrical network. Consumer energy management applications within the scope of InovGrid pilot project are presented. Computational systems are developed for the acquisition, monitoring, control and supervision of consumption data provided by smart meters allowing to incorporate consumer actions on their electrical energy management.
Resumo:
The technique of surface coating using magnetron sputtering is one of the most widely used in the surface engineering, for its versatility in obtaining different films as well as in the micro / nanometric thickness control. Among the various process parameters, those related to the active species of the plasma are of the most fundamental importance in the mechanism and kinetics of deposition. In order to identify the active species of the plasma, parameters such as gas flow, pressure and density of electric power were varied during titanium coating on glass substrate. By flowing argon gas of 10, 20, 30, 40 and 50 sccm (cubic centimeters per minute) for each gas flow a sequential scan of the electric current of 0.10, 0.20, 0.30, 0.40 , 0.50 A. The maximum value of 0.50 A was chosen based both on literature data and on limitations of the equipment. The monitoring of plasma species present during the deposition was carried out in situ by the technique of optical emission spectroscopy (OES) through the spectrometer Ocean Optics USB2000 Series. For this purpose, an apparatus was developed to adapt the OES inside the plasma reactor to stay positioned closest to the target. The radiations emitted by the species were detected by an optical fiber placed behind the glass substrate and their intensities as a function of wavelength were, displayed on a monitor screen. The acquisition time for each condition of the plain parameters was related to the minima of spectral lines intensities due to the film formed on the substrate. The intensities of different emission lines of argon and titanium were then analyzed as a function of time, to determine the active species and estimate the thickness of the deposited films. After the deposition, the coated glasses thin films were characterized by optical transmittance through an infrared laser. It was found that the thickness and deposition rate determined by in situ analysis were consistent with the results obtained by laser transmittance
Resumo:
Com a presente evolução das railguns na Marinha dos Estados Unidos da América e possível instalação em seus navios num futuro muito próximo, outras marinhas se seguirão. Creio que será do interesse da Marinha Portuguesa acompanhar esta evolução tecnológica, considerando as vantagens que advém da adoção deste tipo de armamento. Neste documento são abordados os princípios básicos subjacentes ao funcionamento da railgun, com principal foco nas questões eletrodinâmicas. Pretende-se adquirir familiaridade com este novo tipo de armamento através do estudo crítico dos seus princípios de funcionamento. O princípio básico de funcionamento de uma railgun, à primeira vista, parece bastante simples, à luz da aplicação imediata da expressão da força de Lorentz sobre um condutor percorrido por corrente elétrica. No entanto, tudo se torna mais complicado no caso de uma variação rápida dos parâmetros envolvidos (regime transitório), que exige uma análise mais aprofundada do comportamento da corrente, campos elétrico e magnético, e todos os materiais envolvidos neste sistema. Este trabalho envolveu ainda a construção de duas railguns, uma primeira de dimensões mais pequenas para ganhar familiaridade com o sistema, e uma última de dimensões de laboratório na qual foram feitos vários disparos para testar diferentes tipos de material e dimensões de projétil. Em suma, é demonstrado neste documento uma análise, no domínio do tempo, da distribuição espacial do campo eletromagnético, corrente elétrica e consequente fluxo de energia, complementados por uma parte experimental.
Resumo:
The production of water has become one of the most important wastes in the petroleum industry, specifically in the up stream segment. The treatment of this kind of effluents is complex and normally requires high costs. In this context, the electrochemical treatment emerges as an alternative methodology for treating the wastewaters. It employs electrochemical reactions to increase the capability and efficiency of the traditional chemical treatments for associated produced water. The use of electrochemical reactors can be effective with small changes in traditional treatments, generally not representing a significant additional surface area for new equipments (due to the high cost of square meter on offshore platforms) and also it can use almost the same equipments, in continuous or batch flow, without others high costs investments. Electrochemical treatment causes low environmental impact, because the process uses electrons as reagent and generates small amount of wastes. In this work, it was studied two types of electrochemical reactors: eletroflocculation and eletroflotation, with the aim of removing of Cu2+, Zn2+, phenol and BTEX mixture of produced water. In eletroflocculation, an electrical potential was applied to an aqueous solution containing NaCl. For this, it was used iron electrodes, which promote the dissolution of metal ions, generating Fe2+ and gases which, in appropriate pH, promote also clotting-flocculation reactions, removing Cu2+ and Zn2+. In eletroflotation, a carbon steel cathode and a DSA type anode (Ti/TiO2-RuO2-SnO2) were used in a NaCl solution. It was applied an electrical current, producing strong oxidant agents as Cl2 and HOCl, increasing the degradation rate of BTEX and phenol. Under different flow rates, the Zn2+ was removed by electrodeposition or by ZnOH formation, due the increasing of pH during the reaction. To better understand the electrochemical process, a statistical protocol factor (22) with central point was conducted to analyze the sensitivity of operating parameters on removing Zn2+ by eletroflotation, confirming that the current density affected the process negatively and the flow rate positively. For economical viability of these two electrochemical treatments, the energy consumption was calculated, taking in account the kWh given by ANEEL. The treatment cost obtained were quite attractive in comparison with the current treatments used in Rio Grande do Norte state. In addition, it could still be reduced for the case of using other alternative energy source such as solar, wind or gas generated directly from the Petrochemical Plant or offshore platforms
Resumo:
The thermoelectric energy conversion can be performed directly on generators without moving parts, using the principle of SEEBECK effect, obtained in junctions of drivers' thermocouples and most recently in semiconductor junctions type p-n which have increased efficiency of conversion. When termogenerators are exposed to the temperature difference (thermal gradient) eletromotriz a force is generated inducing the appearance of an electric current in the circuit. Thus, it is possible to convert the heat of combustion of a gas through a burner in power, being a thermoelectric generator. The development of infrared burners, using porous ceramic plate, is possible to improve the efficiency of heating, and reduce harmful emissions such as CO, CO2, NOx, etc.. In recent years the meliorate of thermoelectric modules semiconductor (TEG's) has stimulated the development of devices generating and recovery of thermal irreversibility of thermal machines and processes, improving energy efficiency and exergy these systems, especially processes that enable the cogeneration of energy. This work is based on the construction and evaluation of a prototype in a pilot scale, for energy generation to specific applications. The unit uses a fuel gas (LPG) as a primary energy source. The prototype consists of a porous plate burner infrared, an adapter to the module generator, a set of semiconductor modules purchased from Hi-Z Inc. and a heat exchanger to be used as cold source. The prototype was mounted on a test bench, using a system of acquisition of temperature, a system of application of load and instrumentation to assess its functioning and performance. The prototype had an efficiency of chemical conversion of 0.31% for electrical and heat recovery for cogeneration of about 33.2%, resulting in an overall efficiency of 33.51%. The efficiency of energy exergy next shows that the use of primary energy to useful fuel was satisfactory, although the proposed mechanism has also has a low performance due to underuse of the area heated by the small number of modules, as well as a thermal gradient below the ideal informed by the manufacturer, and other factors. The test methodology adopted proved to be suitable for evaluating the prototype
Resumo:
Ionic liquids (ILs) are organic compounds liquid at room temperature, good electrical conductors, with the potential to form as a means for electrolyte on electrolysis of water, in which the electrodes would not be subjected to such extreme conditions demanding chemistry [1]. This paper describes the synthesis, characterization and study of the feasibility of ionic liquid ionic liquid 1-methyl-3(2,6-(S)-dimethyloct-2-ene)-imidazole tetrafluoroborate (MDI-BF4) as electrolyte to produce hydrogen through electrolysis of water. The MDI-BF4 synthesized was characterized by thermal methods of analysis (Thermogravimetric Analysis - TG and Differential Scanning Calorimetry - DSC), mid-infrared spectroscopy with Fourier transform by method of attenuated total reflectance (FTIR-ATR), nuclear magnetic resonance spectroscopy of hydrogen (NMR 1H) and cyclic voltammetry (CV). Where thermal methods were used to calculate the yield of the synthesis of MDI-BF4 which was 88.84%, characterized infrared spectroscopy functional groups of the compound and the binding B-F 1053 cm-1; the NMR 1H analyzed and compared with literature data defines the structure of MDI-BF4 and the current density achieved by MDI-BF4 in the voltammogram shows that the LI can conduct electrical current indicating that the MDI-BF4 is a good electrolyte, and that their behavior does not change with the increasing concentration of water
Resumo:
Os GEE produzidos pelas atividades humanas podem ser neutralizados com o plantio de árvores, que transformam CO2 em biomassa. O presente trabalho objetivou contabilizar todos os GEE originados da organização e produção da XVII Reunião Brasileira de Manejo e Conservação do Solo e da Água, incluindo transportes e consumo de energia elétrica. A Convenção-Quadro das Nações Unidas sobre a Mudança do Clima (CQNUMC) é o principal órgão fornecedor de metodologias para mitigação das mudanças climáticas. Com base nestas e em dados fornecidos pelo Hotel Glória, pela Empresa Brasileira de Pesquisa Agropecuária (EMBRAPA) e Comissão Organizadora da XVI RBMCSA foi possível estimar as emissões de gases de efeito estufa da XVII RBMCSA. Foi estimado que 48,2 Mg de CO2 equivalentes (CO2eq) serão emitidas entre o período de junho de 2007 e agosto de 2008 devido à elaboração e produção do evento.
Resumo:
Dissertação para obtenção do grau de Mestre em Engenharia Electrotécnica Ramo Energia
Resumo:
Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia de Redes de Comunicação e Multimédia
Resumo:
This works presents a proposal to make automatic the identification of energy thefts in the meter systems through Fuzzy Logic and supervisory like SCADA. The solution we find by to collect datas from meters at customers units: voltage, current, power demand, angles conditions of phasors diagrams of voltages and currents, and taking these datas by fuzzy logic with expert knowledge into a fuzzy system. The parameters collected are computed by fuzzy logic, in engineering alghorithm, and the output shows to user if the customer researched may be consuming electrical energy without to pay for it, and these feedbacks have its own membership grades. The value of this solution is a need for reduce the losses that already sets more than twenty per cent. In such a way that it is an expert system that looks for decision make with assertivity, and it looks forward to find which problems there are on site and then it wont happen problems of relationship among the utility and the customer unit. The database of an electrical company was utilized and the datas from it were worked by the fuzzy proposal and algorithm developed and the result was confirmed