991 resultados para Canadian Canal Society.
Resumo:
Benign Paroxysmal Positional Vertigo is the most common peripheral vestibular disorder, especially in the elderly and presents as the predominant etiology in this population of the degeneration of the utricular macula. Aim: To compare the effectiveness of the approaches after Epley maneuver. Study Design: longitudinal cohort. Materials and Methods: The study included 53 volunteers with Benign Paroxysmal Positional Vertigo of the posterior semicircular canal, divided into Group 1, who underwent Epley maneuver associated with the use of neck collar and post-maneuver instructions, Group 2 underwent the Epley maneuver without the use cervical collar and/or post-maneuver restrictions, and Group 3 underwent the Epley maneuver associated with the use of a mini vibrator, without the use of neck collar and/or post-maneuver restrictions. Results: In the three groups, the number of Epley maneuvers ranged from one to three. We employed the Brazilian Dizziness Handicap Inventory - pre- and post-treatment and observed a statistically significant difference on most scores pre- and post-treatment for both groups. Conclusion: Regardless of the post Epley maneuver treatment selected for the treatment of Benign Paroxysmal Positional Vertigo, it was effective when comparing the Brazilian Dizziness Handicap Inventory pre- and post-treatment.
Resumo:
Interventional cardiology for paediatric and congenital cardiac disease is a relatively young and rapidly evolving field. As the profession begins to establish multi-institutional databases, a universal system of nomenclature is necessary for the field of interventional cardiology for paediatric and congenital cardiac disease. The purpose of this paper is to present the results of the efforts of The International Society for Nomenclature of Paediatric and Congenital Heart Disease to establish a system of nomenclature for cardiovascular catheterisation for congenital and paediatric cardiac disease, focusing both on procedural nomenclature and on the nomenclature of complications associated with interventional cardiology. This system of nomenclature for cardiovascular catheterisation for congenital and paediatric cardiac disease is a component of The International Paediatric and Congenital Cardiac Code. This manuscript is the first part of a two-part series. Part 1 will cover the procedural nomenclature associated with interventional cardiology as treatment for paediatric and congenital cardiac disease. This procedural nomenclature of The International Paediatric and Congenital Cardiac Code will be used in the IMPACT Registry (TM) (IMproving Pediatric and Adult Congenital Treatment) of the National Cardiovascular Data Registry (R) of The American College of Cardiology. Part 2 will cover the nomenclature of complications associated with interventional cardiology as treatment for paediatric and congenital cardiac disease.
Resumo:
Interventional cardiology for paediatric and congenital cardiac disease is a relatively young and rapidly evolving field. As the profession begins to establish multi-institutional databases, a universal system of nomenclature is necessary for the field of interventional cardiology for paediatric and congenital cardiac disease. The purpose of this paper is to present the results of the efforts of The International Society for Nomenclature of Paediatric and Congenital Heart Disease to establish a system of nomenclature for cardiovascular catheterisation for congenital and paediatric cardiac disease, focusing both on procedural nomenclature and the nomenclature of complications associated with interventional cardiology. This system of nomenclature for cardiovascular catheterisation for congenital and paediatric cardiac disease is a component of The International Paediatric and Congenital Cardiac Code. This manuscript is the second part of the two-part series. Part 1 covered the procedural nomenclature associated with interventional cardiology as treatment for paediatric and congenital cardiac disease. Part 2 will cover the nomenclature of complications associated with interventional cardiology as treatment for paediatric and congenital cardiac disease.
Resumo:
The diagnosis and treatment for paediatric and congenital cardiac disease has undergone remarkable progress over the last 60 years. Unfortunately, this progress has been largely limited to the developed world. Yet every year approximately 90% of the more than 1,000,000 children who are born with congenital cardiac disease across the world receive either suboptimal care or are totally denied care. While in the developed world the focus has changed from an effort to decrease post-operative mortality to now improving quality of life and decreasing morbidity, which the focus of this Supplement, the rest of the world still needs to develop basic access to congenital cardiac care. The World Society for Pediatric and Congenital Heart Surgery [http://www.wspchs.org/] was established in 2006. The Vision of the World Society is that every child born anywhere in the world with a congenital heart defect should have access to appropriate medical and surgical care. The Mission of the World Society is to promote the highest quality comprehensive care to all patients with pediatric and/or congenital heart disease, from the fetus to the adult, regardless of the patient`s economic means, with emphasis on excellence in education, research and community service. We present in this article an overview of the epidemiology of congenital cardiac disease, the current and future challenges to improve care in the developed and developing world, the impact of the globalization of cardiac surgery, and the role that the World Society should play. The World Society for Pediatric and Congenital Heart Surgery is in a unique position to influence and truly improve the global care of children and adults with congenital cardiac disease throughout the world [http://www.wspchs.org/].
Resumo:
For some surgical procedures in veterinary dentistry including exodontia, orthognathic surgery, orthopedic surgery, oncologic surgery, and for the placement of dental implants, it is important to know the accurate location of the neurovascular structures within the mandibular canal. The aim of this research was to determine the course of the mandibular canal in the mandible and its relationship with other anatomical structures in brachycephalic dogs using computerized tomography. Mandibles from 10 brachycephalic cadaver dogs were evaluated. Measurements were taken in relation to the lingual, vestibular alveolar crest, and ventral surfaces. These measurements indicated that the mandibular canal descends slightly from the mandibular foramen to the molar area, decreasing the distance of the mandibular canal from the mandibular ventral border The mandibular canal is slightly closer to the lingual surface than the vestibular surface except in the molar tooth region. The mandibular canal continues in a rostral direction occupying the ventral region of the mandibular body, reaching its maximum distance from the alveolar crest at the level of the first molar and fourth premolar teeth. In the third and fourth premolar tooth region, the mandibular canal maintains a similar distance between the vestibular and lingual borders; then, at the level of the second premolar tooth, the distance of the mandibular canal from the lingual and ventral border increases before its termination at the mental, foramen. The study reported here documents the feasibility of using CT to determine the location of the mandibular canal in relation to bony and dental parameters. Although the difference in mandible size of the group of brachycephalic dogs reported here resulted in broad ranges of measurements, it is clear that the MC course may vary between individual dogs. J Vet Dent 26(3); 156 - 163, 2009
Resumo:
This study aimed to test the hypothesis that dentine alterations induced by 810 nm-diode laser may affect the interaction between root canal sealers and the dentin wall. Seventy-two single root human teeth were selected and root canals were enlarged with K-files. Dentine was treated with 0.5% NaOCl and 17% EDTA-T and irradiated (laser group) by diode laser (810 nm/P = 2.5W/I = 1989 W/cm(2)) or remained non-irradiated (control group). Six samples per group were analyzed by scanning electron microscopy (SEM). The remaining samples of each group were divided into three subgroups (n = 10) and sealed with one of the tested sealers (N-Rickert/AHPlus (TM)/Apexit (R)). Apical leakage was estimated by evaluating penetration of 0.5% methylene-blue dye. SEM analysis revealed that dentine at the apical third in irradiated samples was melted and fusioned whereas non-irradiated samples exhibited opened dentinal tubules. Despite the morphological changes induced by irradiation, laser did not affect the sealing ability of N-Rickert and AHPlus (TM) sealers. However, the length of apical leakage in roots filled with Apexit (R) was lower in irradiated root canals than in non-irradiated samples (p < 0.05). Morphological changes of root canal walls promoted by diode laser irradiation may improve de sealing ability of Apexit (R), a calcium hydroxide-based sealer, suggesting that improved sealing promoted by irradiation may represent an additional factor contributing to the endodontic clinical outcome.
Resumo:
The aim of this study was to compare the effects of Nd:YAG, Er:YAG, and diode lasers on the morphology and permeability of root canal walls. The three laser wavelengths mentioned interact differently with dentin and therefore it is possible that the permeability changes caused will determine different indications during endodontic treatment. Twenty-eight human single-rooted teeth were instrumented up to ISO 40 and divided into four groups: group C, control (GC), non-laser irradiated; group N (GN), irradiated with Nd:YAG laser; group E (GE), with Er:YAG laser and group D (GD) with diode laser. After that, the roots were filled with a 2% methylene blue dye, divided into two halves and then photographed. The images were analyzed using Image J software and the percentage of dye penetration in the cervical, middle, and apical root thirds were calculated. Additional scanning electron microscopy (SEM) analyses were also performed. The analysis of variance (ANOVA) showed significant permeability differences between all groups in the middle and cervical thirds (p < 0.05). The Tukey test showed that in the cervical third, GN presented means of dye penetration statistically significantly lower than all of the other groups. In the middle third, GE and GD showed statistically higher dye penetration means than GC and GN. SEM analysis showed melted surfaces for GN, clean wall surfaces with open dentinal tubules for GE, and mostly obliterated dentinal tubules for GD. Er:YAG (2,094 nm) laser and diode laser (808 nm) root canal irradiation increase dentinal permeability and Nd:YAG (1,064 nm) laser decreases dentin permeability, within the studied parameters.
Resumo:
Reviews the literature to provide an overview of the historical significance of the elephant in Sri Lankan society, an association which dates back more than 4,000 years. The present status of this relationship assessed on the basis of the findings of a recent study undertaken on the total economic value of elephants in Sri Lanka. This paper, first briefly outlines the history, evolution, nature and their distribution of the Asian elephant while providing some insights on the status of the elephant (Elephas maxima maxima) in Sri Lanka. Next, it reviews the literature in order to assess the historical affiliation that the elephant has maintained with the Sri Lankan society, its culture, history, mythology and religion. The empirical evidence on the economic value of conservation of the remaining elephant population in Sri Lanka is reviewed and the Sri Lankan people’s attitudes towards conserving this species of wildlife. Literature reviewed and analysis undertaken indicates that the elephant in Sri Lanka, still, as in the past has a special place in Sri Lankan society, particularly, in its culture, religion and value system. Thus, there is a strong case for ensuring the survival of wild elephant population in Sri Lanka. Furthermore, it also suggests that the community as a whole will experience a net benefit from ensuring the survival of wild elephants in Sri Lanka.
Resumo:
Introduction: An experimental mineral trioxide aggregate sealer (MTAS) has been developed for use as a root canal sealer. The aim of this study was to evaluate the setting time, pH, and calcium ion release of MTAS compared with white Portland cement (CPB-40; Votorantin Cimentos, Camargo Correa SA, Pedro Leopoldo, MG, Brazil), white MTA Angelus (MTA; Angelus, Londrina, PR, Brazil), and AH Plus (Dentsply DeTrey, Konstanz, Germany). Methods: For the evaluation of setting time, each material was analyzed using Gilmore-type needles. Polyethylene tubes with the materials were immersed in distilled water for the measurement of pH (digital pH meter) and calcium release (atomic absorption spectrophotometry). The evaluations were performed at 3, 6, 12, 24, and 48 hours and 7, 14, and 28 days. Data were analyzed by analysis of variance and the Tukey test at 5% significance level. Results: MTAS showed higher calcium release at all experimental periods, a greater increase in pH up to 48 hours and the longest setting time. Conclusions: MTAS presented favorable properties for its indication as a root canal sealer. (J Endod 2011;37:844-846)
Resumo:
Objective. The aim of this study was to evaluate the precision of working length determination of 3 electronic apex locators (EALs): Root ZX, RomiApex D-30, and Ipex at 0.0 mm, at the apical foramen (AF), and at 1.0 mm short of the AF. Methodology. Thirty-eight mandibular premolars had their real lengths previously determined. Electronic measurements were determined at 1.0 mm, followed by measurements at 0.0 mm, performed in triplicate. Results. Precision of devices at 1.0 mm and 0.0 mm were: 94.7% and 97.4%, respectively (Root ZX); 78.9% and 97.4% (RomiApex D-30); and 76.3% and 97.4% (Ipex). Although no statistical differences were observed between the EALs at 0.0, at 1.0 mm Root ZX performed significantly better than the others. Conclusion. The EALs had acceptable precision when measuring the working length at the AF. However, when used at levels short of the AF, only Root ZX did not suffer a significant negative effect on precision. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2010;110:e57-e61)
Resumo:
Introduction: The aim of this study was to compare the increase of the root canal area after instrumentation with EndoSequence or ProTaper rotary systems. Methods: Twenty-two mesial root canals from mandibular molars were instrumented. Teeth were mounted on a base, numbered, and divided into 2 groups; teeth from 1-11 (PT group) were instrumented by using the ProTaper system, and teeth from 12-22 (ES group) were instrumented by using the EndoSequence system. Cone beam computed tomography was performed on all teeth before and after instrumentation. Measurements at 3,5, and 7 mm as well as differences in instrument performance were statistically compared by the Student t test at 5% significance level. Results: Both systems increased significantly the root canal area (P < .05) at all levels. Comparison between the rotary systems showed significantly greater increase (P < .05) for EndoSequence at 3 mm, with no statistically significant difference (P < .05) at the other levels. Conclusions: Both rotary systems increased significantly the root canal area. (J Endod 2010;36:1179-1182)
Resumo:
Objective. The aim of this study was to compare Profile .04 taper series 29 instruments and hand files for gutta-percha removal. Study design. Twenty maxillary central incisors with a single straight canal were instrumented and filled. The teeth were divided into 2 groups of 10 specimens each, according to gutta-percha removal techniques: Group 1- Profile series 29 and Group 2- hand files and solvent. The amount of time for gutta-percha removal and the number of fractured instruments were evaluated. Radiographs were taken and the teeth were grooved longitudinally and split. The area of residual debris was measured using computer software. Results. The time for filling material removal was significantly shorter when Profile series 29 was used (P = .00). Regarding cleanliness, there were no statistical differences in the teeth halves evaluations (P = .05). Hand instruments cleaned the canals significantly better than Profiles, in the radiographic analysis considering the whole canal. Overall, the radiographic analysis showed a smaller percentage of residual debris than the teeth halves analysis. Conclusion. The Profile series 29 instruments proved to be faster than hand instruments in removing root filling materials; however, hand instruments yielded better root canal cleanliness. Some residual debris was not visualized by radiographs. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2009; 108: e46-e50)
Resumo:
Objective. The aim was to compare the percentage and depth of sealer penetration into dentinal tubules during obturation using Sealer 26, GuttaFlow, or Sealapex in root canals filled with the lateral compaction technique. Study design. Thirty root canals filled with the lateral compaction technique using GuttaFlow (n = 10), Sealapex (n = 10), or Sealer 26 (n = 10) were analyzed using confocal microscopy. The teeth were sectioned at 3 and 5 mm from the apex, and statistical analyses was performed using analysis of variance-Tukey test (P < .05). Results. Sealapex showed the deepest sealer penetration at both levels evaluated (P < .05). No statistically significance was found between Sealer 26 and GuttaFlow at the 3 mm and 5 mm levels. No statistical significance was found in the percentage of penetration around the root canal wall among the 3 sealers evaluated at both levels. Conclusions. Although Sealapex displayed deeper penetration into the dentinal tubules there was no difference in the percentage of adaptation to the root canal walls among the 3 sealers evaluated. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2009; 108: 450-457)