943 resultados para Buried Pipe
Resumo:
Different types of base fluids, such as water, engine oil, kerosene, ethanol, methanol, ethylene glycol etc. are usually used to increase the heat transfer performance in many engineering applications. But these conventional heat transfer fluids have often several limitations. One of those major limitations is that the thermal conductivity of each of these base fluids is very low and this results a lower heat transfer rate in thermal engineering systems. Such limitation also affects the performance of different equipments used in different heat transfer process industries. To overcome such an important drawback, researchers over the years have considered a new generation heat transfer fluid, simply known as nanofluid with higher thermal conductivity. This new generation heat transfer fluid is a mixture of nanometre-size particles and different base fluids. Different researchers suggest that adding spherical or cylindrical shape of uniform/non-uniform nanoparticles into a base fluid can remarkably increase the thermal conductivity of nanofluid. Such augmentation of thermal conductivity could play a more significant role in enhancing the heat transfer rate than that of the base fluid. Nanoparticles diameters used in nanofluid are usually considered to be less than or equal to 100 nm and the nanoparticles concentration usually varies from 5% to 10%. Different researchers mentioned that the smaller nanoparticles concentration with size diameter of 100 nm could enhance the heat transfer rate more significantly compared to that of base fluids. But it is not obvious what effect it will have on the heat transfer performance when nanofluids contain small size nanoparticles of less than 100 nm with different concentrations. Besides, the effect of static and moving nanoparticles on the heat transfer of nanofluid is not known too. The idea of moving nanoparticles brings the effect of Brownian motion of nanoparticles on the heat transfer. The aim of this work is, therefore, to investigate the heat transfer performance of nanofluid using a combination of smaller size of nanoparticles with different concentrations considering the Brownian motion of nanoparticles. A horizontal pipe has been considered as a physical system within which the above mentioned nanofluid performances are investigated under transition to turbulent flow conditions. Three different types of numerical models, such as single phase model, Eulerian-Eulerian multi-phase mixture model and Eulerian-Lagrangian discrete phase model have been used while investigating the performance of nanofluids. The most commonly used model is single phase model which is based on the assumption that nanofluids behave like a conventional fluid. The other two models are used when the interaction between solid and fluid particles is considered. However, two different phases, such as fluid and solid phases is also considered in the Eulerian-Eulerian multi-phase mixture model. Thus, these phases create a fluid-solid mixture. But, two phases in the Eulerian-Lagrangian discrete phase model are independent. One of them is a solid phase and the other one is a fluid phase. In addition, RANS (Reynolds Average Navier Stokes) based Standard κ-ω and SST κ-ω transitional models have been used for the simulation of transitional flow. While the RANS based Standard κ-ϵ, Realizable κ-ϵ and RNG κ-ϵ turbulent models are used for the simulation of turbulent flow. Hydrodynamic as well as temperature behaviour of transition to turbulent flows of nanofluids through the horizontal pipe is studied under a uniform heat flux boundary condition applied to the wall with temperature dependent thermo-physical properties for both water and nanofluids. Numerical results characterising the performances of velocity and temperature fields are presented in terms of velocity and temperature contours, turbulent kinetic energy contours, surface temperature, local and average Nusselt numbers, Darcy friction factor, thermal performance factor and total entropy generation. New correlations are also proposed for the calculation of average Nusselt number for both the single and multi-phase models. Result reveals that the combination of small size of nanoparticles and higher nanoparticles concentrations with the Brownian motion of nanoparticles shows higher heat transfer enhancement and thermal performance factor than those of water. Literature suggests that the use of nanofluids flow in an inclined pipe at transition to turbulent regimes has been ignored despite its significance in real-life applications. Therefore, a particular investigation has been carried out in this thesis with a view to understand the heat transfer behaviour and performance of an inclined pipe under transition flow condition. It is found that the heat transfer rate decreases with the increase of a pipe inclination angle. Also, a higher heat transfer rate is found for a horizontal pipe under forced convection than that of an inclined pipe under mixed convection.
Resumo:
The thesis deals with the experimental investigation of turbulent pipe flow at high Reynolds number. Wall-bounded turbulence is an extremely relevant topic for engineering and natural science applications and yet many aspects of the physics are not clear due to the difficulty in performing high Re experiments. To overcome these difficulties the CICLoPE Laboratory was developed, the main element of which is the Long Pipe wind tunnel. The facility is unique in its kind, as thanks to its large scale it delivers a flow quality and resolution that can not be achieved elsewhere at these Reynolds number. Reported here are the results from the first experimental campaign performed in the facility. A first part of the results presented concerns the characterization of this new facility. Flow quality and stability are assessed, particular attention is given to the characterization of pressure drop. The scaling of velocity fluctuations is analysed. The magnitude of the inner peak of the streamwise normal stress shows an increasing trend up to the highest Reynolds number examined, while no outer peak was clearly distinguishable from present measurements. Scaling of coherent motions is investigated via spectral analysis. An inner and outer spectral peaks are identified, with the former scaling in inner units while the latter neither following inner nor outer scaling, and increasing in magnitude with Re. Analysis of the spectra at y+ ≈ 15 shows how the increase of Reynolds normal stress is related to the influence of large scales in the inner wall region. Quadrant analysis was carried out on streamwise and wall-normal velocity fluctuations. The results show the important role in contribution to Reynolds shear stress of highly intermittent and strong events like ejections, that assume an even more intermittent and dominant role with the increase of Reynolds number.
Resumo:
Passive scalars measurements in turbulent pipe flows are difficult to perform and only few experimental data are available in literature. The present thesis deals with the experimental acquisition and study of the first turbulent temperature profile inside the CICLoPE wind tunnel through cold wire anemometry technique at Reτ = 6000 and Reτ = 9500. This type of measurements provides not only useful data on temperature (and passive scalars) behaviour and statistics in turbulent pipe flows, but could be used also for temperature correction of turbulent velocity profiles. In the present work, subsequent acquisitions of temperature and velocity profiles has been performed at the same Reynolds number and in the same points, through cold wire and hot wire techniques respectively. Taking as reference data from both DNS and experimental campaigns, the activity has been carried out obtaining satisfactory results. We have verified the presence of turbulent temperature profile inside the CICLoPE wind tunnel and then studied its statistical and spectral behaviours obtaining results in agreement with existing data from Hishida, Nagano, and Ferro. Cold wire temperature data were then used to correct hot wire velocity data, obtaining a slightly improvement in the near wall region.
Resumo:
Improving heat transfer is a critical area of research in various fields such as thermal engineering, energy conversion and aeronautical engineering. The aim of this thesis is to present the design, construction and testing of an experimental setup for the study of heat transfer enhancement in a turbulent boundary layer using cross-flow pulsed jets. The set-up is designed to generate and control pulsed jets, measure heat transfer and acquire all parameters related to wind tunnel flow and is also capable of varying the parameters of the pulsed jets, such as frequency, amplitude and the duty cycle, in order to study the effects on the increase in heat transfer. The thesis describes the design phases, the construction process and the final successful testing of the plant. The test results verify the functionality and accuracy of the set-up and ensure that it can be used to perform a full experimental campaign to investigate heat transfer enhancement using cross-flow pulsed jets in a turbulent layer boundary.
Resumo:
O tratamento de esgotos de pequenas cidades por lagoas de estabilização é uma maneira simples, eficiente e de baixo custo. Os esgotos são uma fonte de contaminação das águas e solos e, conseqüentemente, contribuem para a transmissão de doenças, além de serem uma ameaça à preservação do meio ambiente. Surge a necessidade de investigar as condições dos efluentes lançados nos cursos d´água. O presente trabalho tem como objetivo realizar uma investigação da qualidade das águas residuárias tratadas por lagoas de estabilização de uma estação de tratamento de esgoto localizadas no município de São Lourenço da Serra no Vale da Ribeira no Estado de São Paulo e verificar os riscos sanitários e a comunidade aquática no Rio São Lourenço da Serra. Foram realizadas amostragens para avaliar o conjunto de lagoas anaeróbia e facultativa da estação de tratamento de esgoto do Município de São Lourenço da Serra. Os parâmetros utilizados foram pH, temperatura do ar e da água, condições climáticas, demanda bioquímica de oxigênio e nitrogênio amoniacal, bactérias termotolerantes, pigmentos fotossintéticos e comunidade zooplanctônica. Verificou-se que s sistemas de lagoa anaeróbia e facultativa foram eficientes na produção de efluente e apresentou alguns valores de acordo com a Resolução Conama nº 357, que estabelecem os valores limites para lançamento em corpos d´água. O rio São Lourenço está localizado em uma área de proteção ambiental. Os dados são comparados aos limites estabelecidos na Classe 1 e 2 e demonstram processo de eutrofização, colocando em risco à biodiversidade aquática e a saúde da população
Resumo:
Shallow subsurface layers of gold nanoclusters were formed in polymethylmethacrylate (PMMA) polymer by very low energy (49 eV) gold ion implantation. The ion implantation process was modeled by computer simulation and accurately predicted the layer depth and width. Transmission electron microscopy (TEM) was used to image the buried layer and individual nanoclusters; the layer width was similar to 6-8 nm and the cluster diameter was similar to 5-6 nm. Surface plasmon resonance (SPR) absorption effects were observed by UV-visible spectroscopy. The TEM and SPR results were related to prior measurements of electrical conductivity of Au-doped PMMA, and excellent consistency was found with a model of electrical conductivity in which either at low implantation dose the individual nanoclusters are separated and do not physically touch each other, or at higher implantation dose the nanoclusters touch each other to form a random resistor network (percolation model). (C) 2009 American Vacuum Society. [DOI: 10.1116/1.3231449]
Resumo:
PMMA (polymethylmethacrylate) was ion implanted with gold at very low energy and over a range of different doses using a filtered cathodic arc metal plasma system. A nanometer scale conducting layer was formed, fully buried below the polymer surface at low implantation dose, and evolving to include a gold surface layer as the dose was increased. Depth profiles of the implanted material were calculated using the Dynamic TRIM computer simulation program. The electrical conductivity of the gold-implanted PMMA was measured in situ as a function of dose. Samples formed at a number of different doses were subsequently characterized by Rutherford backscattering spectrometry, and test patterns were formed on the polymer by electron beam lithography. Lithographic patterns were imaged by atomic force microscopy and demonstrated that the contrast properties of the lithography were well maintained in the surface-modified PMMA.
Resumo:
A buried conducting layer of metal/polymer nanocomposite was formed by very low energy gold ion implantation into polymethylmethacrylate. The conducting layer is similar to 3 nm deep and of width similar to 1 nm. In situ resistivity measurements were performed as the implantation proceeded, and the conductivity thus obtained as a function of buried gold concentration. The measured conductivity obeys the behavior well established for composites in the percolation regime. The critical concentration, below which the polymer remains an insulator, is attained at a dose similar to 1.0 x 10(16) atoms/cm(2) of implanted gold ions. (C) 2008 American Institute of Physics.
Resumo:
This study was carried out in a continental Atlantic Forest located in the southern region of Sao Paulo State, southeastern Brazil. The aim of the study was to evaluate the vegetation dynamics in similar to 70 km forest ecosystem transect that occurred during the late Pleistocene and Holocene in this region, using the stable carbon isotopes (delta C-13) analysis on soil organic matter (SOM) and the C-14 dating of buried charcoal fragments and the humin fraction of SOM. The isotope data (delta C-13) of SOM in the deeper horizons, indicating the presence of more open vegetation than the present, with a probable mixture of C-3 and C-4 plants, suggesting the presence of a drier climate in the period of similar to 20 ka to similar to 16-14 ka BP. From similar to 16 to 14 ka BP to the present, a significant predominance Of C3 plants was observed, indicating an expansion of the forest, probably associated with the presence of a more humid climate than the previous period. The results indicated the presence of open vegetation during the late glacial, probably associated with a drier period, also observed in other regions of Brazil. The Atlantic Forest ecosystem seems to have developed at least since the early Holocene in Southeastern Brazil. (c) 2007 Elsevier Ltd and INQUA. All rights reserved.
Resumo:
In this paper, a novel wire-mesh sensor based on permittivity (capacitance) measurements is applied to generate images of the phase fraction distribution and investigate the flow of viscous oil and water in a horizontal pipe. Phase fraction values were calculated from the raw data delivered by the wire-mesh sensor using different mixture permittivity models. Furthermore, these data were validated against quick-closing valve measurements. Investigated flow patterns were dispersion of oil in water (Do/w) and dispersion of oil in water and water in oil (Do/w&w/o). The Maxwell-Garnett mixing model is better suited for Dw/o and the logarithmic model for Do/w&w/o flow pattern. Images of the time-averaged cross-sectional oil fraction distribution along with axial slice images were used to visualize and disclose some details of the flow.
Resumo:
This paper presents new experimental flow boiling heat transfer results in micro-scale tubes. The experimental data were obtained in a horizontal 2.3 mm I.D stainless steel tube with heating length of 464 mm, R134a and R245fa as working fluids, mass velocities ranging from 50 to 700 kg m(-2) s(-1), heat flux from 5 to 55 kW m(-2), exit saturation temperatures of 22, 31 and 41 degrees C, and vapor qualities ranging from 0.05 to 0.99. Flow pattern characterization was also performed from images obtained by high-speed filming. Heat transfer coefficient results from 1 to 14 kW m(-2) K(-1) were measured. It was found that the heat transfer coefficient is a strong function of heat flux, mass velocity and vapor quality. The experimental data were compared against ten flow boiling predictive methods from the literature. Liu and Winterton [3], Zhang et al. [5] and Saitoh et al. [6] worked best for both fluids, capturing most of the experimental heat transfer trends. (C) 2010 Elsevier Ltd. All rights reserved.
Resumo:
Literature presents a huge number of different simulations of gas-solid flows in risers applying two-fluid modeling. In spite of that, the related quantitative accuracy issue remains mostly untouched. This state of affairs seems to be mainly a consequence of modeling shortcomings, notably regarding the lack of realistic closures. In this article predictions from a two-fluid model are compared to other published two-fluid model predictions applying the same Closures, and to experimental data. A particular matter of concern is whether the predictions are generated or not inside the statistical steady state regime that characterizes the riser flows. The present simulation was performed inside the statistical steady state regime. Time-averaged results are presented for different time-averaging intervals of 5, 10, 15 and 20 s inside the statistical steady state regime. The independence of the averaged results regarding the time-averaging interval is addressed and the results averaged over the intervals of 10 and 20 s are compared to both experiment and other two-fluid predictions. It is concluded that the two-fluid model used is still very crude, and cannot provide quantitative accurate results, at least for the particular case that was considered. (C) 2009 Elsevier Inc. All rights reserved.
Resumo:
On-line leak detection is a main concern for the safe operation of pipelines. Acoustic and mass balance are the most important and extensively applied technologies in field problems. The objective of this work is to compare these leak detection methods with respect to a given reference situation, i.e., the same pipeline and monitoring signals acquired at the inlet and outlet ends. Experimental tests were conducted in a 749 m long laboratory pipeline transporting water as the working fluid. The instrumentation included pressure transducers and electromagnetic flowmeters. Leaks were simulated by opening solenoid valves placed at known positions and previously calibrated to produce known average leak flow rates. Results have clearly shown the limitations and advantages of each method. It is also quite clear that acoustics and mass balance technologies are, in fact, complementary. In general, an acoustic leak detection system sends out an alarm more rapidly and locates the leak more precisely, provided that the rupture of the pipeline occurs abruptly enough. On the other hand, a mass balance leak detection method is capable of quantifying the leak flow rate very accurately and of detecting progressive leaks.
Resumo:
A general transition criterion is proposed in order to locate the core-annular flow pattern in horizontal and vertical oil-water flows. It is based on a rigorous one-dimensional two-fluid model of liquid-liquid two-phase flow and considers the existence of critical interfacial wave numbers related to a non-negligible interfacial tension term to which the linear stability theory still applies. The viscous laminar-laminar flow problem is fully resolved and turbulence effects on the stability are analyzed through experimentally obtained shape factors. The proposed general transition criterion includes in its formulation the inviscid Kelvin-Helmholtz`s discriminator. If a theoretical maximum wavelength is considered as a necessary condition for stability, a stability criterion in terms of the Eotvos number is achieved. Effects of interfacial tension, viscosity ratio, density difference, and shape factors on the stability of core-annular flow are analyzed in detail. The more complete modeling allowed for the analysis of the neutral-stability wave number and the results strongly suggest that the interfacial tension term plays an indispensable role in the correct prediction of the stable region of core-annular flow pattern. The incorporation of a theoretical minimum wavelength into the transition model produced significantly better results. The criterion predictions were compared with recent data from the literature and the agreement is encouraging. (C) 2007 American Institute of Chemical Engineers.