974 resultados para Bifurcated stent Graft
Resumo:
OBJECTIVE: Balloon-expandable stent valves require flow reduction during implantation (rapid pacing). The present study was designed to compare a self-expanding stent valve with annular fixation versus a balloon-expandable stent valve. METHODS: Implantation of a new self-expanding stent valve with annular fixation (Symetis, Lausanne, Switzerland) was assessed versus balloon-expandable stent valve, in a modified Dynatek Dalta pulse duplicator (sealed port access to the ventricle for transapical route simulation), interfaced with a computer for digital readout, carrying a 25 mm porcine aortic valve. The cardiovascular simulator was programmed to mimic an elderly woman with aortic stenosis: 120/85 mmHg aortic pressure, 60 strokes/min (66.5 ml), 35% systole (2.8 l/min). RESULTS: A total of 450 cardiac cycles was analysed. Stepwise expansion of the self-expanding stent valve with annular fixation (balloon-expandable stent valve) resulted in systolic ventricular increase from 120 to 121 mmHg (126 to 830+/-76 mmHg)*, and left ventricular outflow obstruction with mean transvalvular gradient of 11+/-1.5 mmHg (366+/-202 mmHg)*, systolic aortic pressure dropped distal to the valve from 121 to 64.5+/-2 mmHg (123 to 55+/-30 mmHg) N.S., and output collapsed to 1.9+/-0.06 l/min (0.71+/-0.37 l/min* (before complete obstruction)). No valve migration occurred in either group. (*=p<0.05). CONCLUSIONS: Implantation of this new self-expanding stent valve with annular fixation has little impact on haemodynamics and has the potential for working heart implantation in vivo. Flow reduction (rapid pacing) is not necessary.
Resumo:
AIM: To investigate the putative modifying effect of dual antiplatelet therapy (DAPT) use on the incidence of stent thrombosis at 3 years in patients randomized to Endeavor zotarolimus-eluting stent (E-ZES) or Cypher sirolimus-eluting stent (C-SES). METHODS AND RESULTS: Of 8709 patients in PROTECT, 4357 were randomized to E-ZES and 4352 to C-SES. Aspirin was to be given indefinitely, and clopidogrel/ticlopidine for ≥3 months or up to 12 months after implantation. Main outcome measures were definite or probable stent thrombosis at 3 years. Multivariable Cox regression analysis was applied, with stent type, DAPT, and their interaction as the main outcome determinants. Dual antiplatelet therapy adherence remained the same in the E-ZES and C-SES groups (79.6% at 1 year, 32.8% at 2 years, and 21.6% at 3 years). We observed a statistically significant (P = 0.0052) heterogeneity in treatment effect of stent type in relation to DAPT. In the absence of DAPT, stent thrombosis was lower with E-ZES vs. C-SES (adjusted hazard ratio 0.38, 95% confidence interval 0.19, 0.75; P = 0.0056). In the presence of DAPT, no difference was found (1.18; 0.79, 1.77; P = 0.43). CONCLUSION: A strong interaction was observed between drug-eluting stent type and DAPT use, most likely prompted by the vascular healing response induced by the implanted DES system. These results suggest that the incidence of stent thrombosis in DES trials should not be evaluated independently of DAPT use, and the optimal duration of DAPT will likely depend upon stent type (Clinicaltrials.gov number NCT00476957).
Resumo:
Purpose: To assess geographical differences within Switzerland regarding management and revascularization procedures for acute myocardial infarction (AMI). Methods: Swiss hospital discharge database for period 2007-2008. The main inclusion criterion was AMI as a primary discharge diagnosis. AMI revascularization procedures were identified and seven Swiss regions (Leman, Mittelland, Northwest, Zurich, Central, Eastern and Ticino) were analyzed. Results: Data from 25,674 AMI discharges were analyzed. Almost half (53.6%) of them were managed in a single hospital, the values ranging from 63.1% (Leman) to 31.4% (Ticino) see table. Relative to the total number of discharges, the highest Intensive Care Unit admission rate was in Leman (69.7%), the lowest (16.4%) in Ticino (Swiss average: 35.8%). Intracoronary revascularization rates were highest in Leman (51.6%) and lowest (30.8%) in Central Switzerland (Swiss average: 41.4%). Bare (non-drug-eluting) stents use was highest in Leman (33.1%) and lowest (7.0%) in Ticino (Swiss average: 15.8%), while drug eluting stent use was highest (32.8%) in Ticino and lowest (13.9%) in Central Switzerland (Swiss average: 24.0%). Coronary artery bypass graft rates were highest (4.6%) in Ticino and lowest (0.4%) in Eastern Switzerland (Swiss average: 2.6%). Mechanical circulatory assistance rates were highest (4.1%) in Zurich and lowest (0.4%) in Ticino (Swiss average: 1.7%). The differences in revascularization procedures remained after adjusting for age, single or multiple hospital management and gender. Conclusion: In Switzerland, significant geographical differences in management and revascularization procedures for AMI were found.
Resumo:
BACKGROUND & AIMS: Recent studies have described a major impact of genetic variations near the IL28B gene on the natural course and outcome of antiviral therapy in chronic hepatitis C. We therefore, aimed to explore the impact of donor and recipient genotypes of these polymorphisms on hepatitis C virus (HCV) liver graft reinfection. METHODS: Donor and recipient genotypes of IL28B rs12979860C>T single nucleotide polymorphism were determined in 91 patients with HCV liver graft reinfection, 47 of whom were treated with pegylated interferon-α (PEG-IFN-α) and ribavirin. IL28B genetic polymorphisms were correlated with the natural course and treatment outcome of recurrent hepatitis C. RESULTS: Patients requiring liver transplantation due to end-stage chronic hepatitis C appeared to be selected toward the adverse genotypes rs12979860 CT/TT compared to non-transplanted HCV-infected patients (p=0.046). Patients with the donor genotype rs12979860 CC had higher peak ALT and HCV RNA serum concentrations than those with CT/TT (p=0.04 and 0.06, respectively). No association was observed between ALT/HCV RNA serum concentrations and recipient genotypes (p>0.3). More important, donor IL28B rs12979860 CC vs. CT/TT genotypes were associated with rapid, complete early, and sustained virologic response (RVR, cEVR, SVR) to treatment with PEG-IFN-α and ribavirin (p=0.003, 0.0012, 0.008, respectively), but weaker associations of recipient genotypes with RVR, cEVR, and SVR were observed as well (p=0.0046, 0.115, 0.118, respectively). CONCLUSIONS: We provide evidence for a dominant, but not exclusive impact of the donor rather than the recipient IL28B genetic background on the natural course and treatment outcome of HCV liver graft reinfection.
Resumo:
Objective: To evaluate the agreement between multislice CT (MSCT) and intravascular ultrasound (IVUS) to assess the in-stent lumen diameters and lumen areas of left main coronary artery (LMCA) stents. Design: Prospective, observational single centre study. Setting: A single tertiary referral centre. Patients: Consecutive patients with LMCA stenting excluding patients with atrial fibrillation and chronic renal failure. Interventions: MSCT and IVUS imaging at 912 months follow-up were performed for all patients. Main outcome measures: Agreement between MSCT and IVUS minimum luminal area (MLA) and minimum luminal diameter (MLD). A receiver operating characteristic (ROC) curve was plotted to find the MSCT cut-off point to diagnose binary restenosis equivalent to 6 mm2 by IVUS. Results: 52 patients were analysed. PassingBablok regression analysis obtained a β coefficient of 0.786 (0.586 to 1.071) for MLA and 1.250 (0.936 to 1.667) for MLD, ruling out proportional bias. The α coefficient was −3.588 (−8.686 to −0.178) for MLA and −1.713 (−3.583 to −0.257) for MLD, indicating an underestimation trend of MSCT. The ROC curve identified an MLA ≤4.7 mm2 as the best threshold to assess in-stent restenosis by MSCT. Conclusions: Agreement between MSCT and IVUS to assess in-stent MLA and MLD for LMCA stenting is good. An MLA of 4.7 mm2 by MSCT is the best threshold to assess binary restenosis. MSCT imaging can be considered in selected patients to assess LMCA in-stent restenosis
Resumo:
Rapport de synthèse : But: la resténose intra-stent au sirolimus (SAS) reste un problème clinique. Parmi tes diverses approches thérapeutiques disponibles aujourd'hui aucune n'a la primauté car tes résultats à moyen terme restent relativement médiocres. Méthodologie: les patients souffrant d'une resténose intra-SAS chez lesquels un second SAS a été implanté comme traitement de cette resténose ont été inclus dans ce registre. Lors d'ischémie clinique ou électrique après implantation d'un SAS les malades chez lesquels l'angioplastie au ballon seul ne donnait pas un résultat satisfaisant ont bénéficié de l'implantation d'un stent actif dans un stent actif. Résultats: vingt-sept patients sont inclus dans ce registre. La resténose était de type focale dans 34% des cas, diffuse dans 59% des cas et proliférative dans 7% des cas. La procédure a été un succès chez tous les patients sans complications aiguës durant l'hospitalisation. A 14±7 mois, on dénombre 8 (30%) événements cardiaques majeurs (1 mort, 1 infarctus du myocarde, 4 revascularisations additionnelles de la lésion, 1 revascularisation additionnelle du vaisseau cible). Un patient a subi un pontage aorto-coronarien. Dix-neuf patients (70%) ont évolué sans aucun problème. Conclusion: en conclusion, l'implantation d'un SAS pour traiter une resténose intra-SAS est réalisable avec un très bon résultat immédiat. Cependant, l'incidence d'un événement cardiaque majeur reste élevée à long terme.
Resumo:
OBJECTIVE: An operative technique is described as a salvage treatment for severe subglottic and supraglottic laryngeal stenosis. In addition to expansion of the laryngeal framework with an anterior cartilage graft, as used in a classical laryngotracheal reconstruction, the scar tissue obliterating the airway lumen is excised and a mucosal graft is placed to reconstruct the inner lining of the airway. The graft is harvested from buccal mucosa. METHODS: The operative technique is outlined. Three cases, 2 paediatric and one adult, with complete or near complete laryngeal stenosis are presented where this operative technique was employed. In all patients several surgeries had been performed previously which were unsuccessful. RESULTS: In all 3 patients a patent airway was achieved with decannulation of the tracheostomy in the 2 paediatric patients. CONCLUSIONS: In patients with severe subglottic or supraglottic airway stenosis where other surgeries have failed, excision of endoluminal scar tissue and placement of a buccal mucosal graft, in addition to conventional laryngotracheal reconstruction, is a promising technique. In revision cases of subglottic stenosis cricotracheal resection might not be an option because of scarring from previous surgeries. This operation is an alternative, which allows an increase in the airway lumen by excising the scar tissue then re-lining the exposed internal lumen. The buccal mucosa reduces granulation formation and re-stenosis.
Resumo:
Aim: The aim of this study was to assess the effect of iStent (trabecular micro-bypass stent) implantation in combination with phacoemulsification on IOP and glaucoma medications and to compare this to the outcome of phacoemulsification alone. Patients and Methods: A retrospective consecutive comparative review was undertaken. 131 eyes with ocular hypertension and medically controlled glaucoma underwent phacoemulsification alone (n = 78 group I) or combined with gonioscopic-guided implantation of one iStent (n = 31, group II) or two iStents (n = 22, group III). Patients were assessed at postoperative weeks 1, 3 and 6, and months 3 and 6. Pre- and post-operative measures included visual acuity, IOP and glaucoma medications. Results: Post-operatively at 6 months, mean IOP decreased from 16.3 mmHg to 14.2 mmHg in group I (p < 0.01), from 16.7 mmHg to 15.1 mmHg in group II (p < 0.16) and from 17.0 to 13.8 in group III (p = 0.05). Mean glaucoma medication decreased from 1.9 to 1.6 in group I (8 %, p = 0.12), from 2.5 to 0.8 in group II (27 %, p = 0.04), and from 2.1 to 1.0 in group III (45 %, p < 0.01). Conclusions: iStent implantation resulted in similar IOP reduction to phacoemulsification alone but achieved a significantly greater reduction in glaucoma medications. This may improve compliance and quality of life, and reduce health care costs in patients with early to moderate glaucoma.
Resumo:
BACKGROUND: Recurrent hepatitis C virus infection after liver transplantation is associated with reduced graft and patient survival. Re-transplantation for graft failure due to recurrent hepatitis C is controversial and not performed in all centers. CASE PRESENTATION: We describe a 54-year-old patient with hepatitis C virus genotype 1b infection and a null response to pegylated interferon-α and ribavirin who developed decompensated graft cirrhosis 6 years after a first liver transplantation. Treatment with sofosbuvir and ribavirin allowed for rapid negativation of serum HCV RNA and was well tolerated despite advanced liver and moderate renal dysfunction. Therapeutic drug monitoring did not reveal any clinically significant drug-drug interactions. Despite virological response, the patient remained severely decompensated and re-transplantation was performed after 46 days of undetectable serum HCV RNA. The patient is doing well 12 months after his second liver transplantation and remains free of hepatitis C virus. CONCLUSIONS: The use of directly acting antivirals may allow for successful liver re-transplantation for recipients who remain decompensated despite virological response and is likely to improve the outcome of liver re-transplantation for end-stage recurrent hepatitis C.
Resumo:
Objective: To evaluate the agreement between multislice CT (MSCT) and intravascular ultrasound (IVUS) to assess the in-stent lumen diameters and lumen areas of left main coronary artery (LMCA) stents. Design: Prospective, observational single centre study. Setting: A single tertiary referral centre. Patients: Consecutive patients with LMCA stenting excluding patients with atrial fibrillation and chronic renal failure. Interventions: MSCT and IVUS imaging at 9-12 months follow-up were performed for all patients. Main outcome measures: Agreement between MSCT and IVUS minimum luminal area (MLA) and minimum luminal diameter (MLD). A receiver operating characteristic (ROC) curve was plotted to find the MSCT cut-off point to diagnose binary restenosis equivalent to 6 mm2 by IVUS. Results: 52 patients were analysed. Passing-Bablok regression analysis obtained a β coefficient of 0.786 (0.586 to 1.071) for MLA and 1.250 (0.936 to 1.667) for MLD, ruling out proportional bias. The α coefficient was −3.588 (−8.686 to −0.178) for MLA and −1.713 (−3.583 to −0.257) for MLD, indicating an underestimation trend of MSCT. The ROC curve identified an MLA ≤4.7 mm2 as the best threshold to assess in-stent restenosis by MSCT. Conclusions: Agreement between MSCT and IVUS to assess in-stent MLA and MLD for LMCA stenting is good. An MLA of 4.7 mm2 by MSCT is the best threshold to assess binary restenosis. MSCT imaging can be considered in selected patients to assess LMCA in-stent restenosis
Resumo:
OBJETIVOS: Descrever o uso do "shunt" intra-hepático portossistêmico (TIPS) e do "stent" venoso supra-hepático no manejo da síndrome de Budd-Chiari, enfocando suas indicações, aspectos técnicos e benefícios do procedimento. MATERIAIS E MÉTODOS: De janeiro de 1999 a março de 2002, nove casos de síndrome de Budd-Chiari foram encaminhados ao Serviço de Hemodinâmica do Hospital São Lucas, Porto Alegre, RS. A obstrução venosa supra-hepática foi constatada em todos os casos por meio de ultra-sonografia com Doppler em cores. A criação de TIPS foi realizada entre o sistema venoso supra-hepático ou a veia cava inferior e a veia porta, posicionando-se a endoprótese entre as duas abordagens. Doppler em cores pós-procedimento foi efetuado em todos os pacientes em períodos seriados. RESULTADOS: Três casos foram tratados inicialmente com inserção de "stent" venoso por apresentarem estenose preponderante em veias supra-hepáticas. Em dois desses casos ocorreu trombose do "stent", sendo necessária colocação de TIPS. Os demais seis casos foram tratados primariamente com TIPS. Dos oito "shunts" criados, trombose da endoprótese foi constatada em três casos, resolvidas com limpeza dos trombos e dilatação com balão em um caso e inserção de novas próteses nos demais. Embolização com molas de colaterais venosas ectasiadas foi efetuada em um paciente. CONCLUSÕES: A colocação de TIPS constitui-se numa estratégia terapêutica segura e efetiva na síndrome de Budd-Chiari, promovendo uma significativa melhora clínica e hemodinâmica dos pacientes, evitando procedimentos mais invasivos e podendo, em casos sem cirrose estabelecida, servir de tratamento definitivo da hipertensão portal.
Resumo:
OBJECTIVE: The primary end points of this study were safety and efficacy of early cannulation of the Flixene graft (Maquet-Atrium Medical, Hudson, NH). Secondary end points were complications and patency. METHODS: This is a prospective single-center nonrandomized study. Study data included patient characteristics; history of vascular access; operative technique; interval between implantation and initial cannulation; complications; and patency at 1 month, 3 months, and every 6 months. Patency rates were estimated by the Kaplan-Meier method. RESULTS: Between January 2011 and September 2013, a total of 46 Flixene grafts were implanted in 44 patients (27 men) with a mean age of 63 years. The implantation site was the upper arm in 67% of cases, the forearm in 11%, and the thigh in 22%. Seven grafts were never cannulated during the study period. Of the remaining 39 grafts, 32 (82%) were successfully cannulated within the first week after implantation, including 16 (41%) on the first day. The median interval from implantation to initial cannulation was 2 days (interquartile range, 1-3 days). The median follow-up was 223.5 days (interquartile range, 97-600 days). Five hematomas occurred, but only one required surgical revision. Primary assisted and secondary patency rates were 65% and 86%, respectively, at 6 months and 56% and 86%, respectively, at 1 year. CONCLUSIONS: This study suggests that cannulation of the Flixene graft within 1 week after implantation is safe and effective. Early cannulation avoids or shortens the need for a temporary catheter. One-year patency rates appeared to be comparable to those achieved with conventional grafts, but long-term follow-up and randomized controlled studies will be needed to confirm this finding.
Resumo:
This report describes a solution for a restenosis and for the fracture of a stent in the vertebral artery in a patient suffering from vertebrobasilar symptoms. Angiography demonstrates restenosis of a vertebral stent as well as its fracture and migration into the subclavian artery. This complication was managed percutaneously by passing a guide wire through the fractured stent. Pre-dilatation and kissing balloon techniques were applied in both the vertebral and subclavian arteries to modify the stent's dimensions and shape it into the form of a "ring." Postprocedural angiography demonstrated an excellent final result with the assistance of StentBoost visualization. Control angiography at six months also utilized StentBoost imaging and confirmed the patency of the bifurcation and that the stent was not displaced.
Improving coronary artery bypass graft durability: use of the external saphenous vein graft support.
Resumo:
Coronary bypass grafting remains the best option for patients suffering from multivessel coronary artery disease, and the saphenous vein is used as an additional conduit for multiple complete revascularizations. However, the long-term vein graft durability is poor, with almost 75% of occluded grafts after 10 years. To improve the durability, the concept of an external supportive structure was successfully developed during the last years: the eSVS Mesh device (Kips Bay Medical) is an external support for vein graft made of weft-knitted nitinol wire into a tubular form with an approximate length of 24 cm and available in three diameters (3.5, 4.0 and 4.5 mm). The device is placed over the outer wall of the vein and carefully deployed to cover the full length of the graft. The mesh is flexible for full adaptability to the heart anatomy and is intended to prevent kinking and dilatation of the vein in addition to suppressing the intima hyperplasia induced by the systemic blood pressure. The device is designed to reduce the vein diameter of about 15-20% at most to prevent the vein radial expansion induced by the arterial blood pressure, and the intima hyperplasia leading to the graft failure. We describe the surgical technique for preparing the vein graft with the external saphenous vein graft support (eSVS Mesh) and we share our preliminary clinical results.