818 resultados para Anaerobic reserve recovery
Resumo:
The smart grid concept is a key issue in the future power systems, namely at the distribution level, with deep concerns in the operation and planning of these systems. Several advantages and benefits for both technical and economic operation of the power system and of the electricity markets are recognized. The increasing integration of demand response and distributed generation resources, all of them mostly with small scale distributed characteristics, leads to the need of aggregating entities such as Virtual Power Players. The operation business models become more complex in the context of smart grid operation. Computational intelligence methods can be used to give a suitable solution for the resources scheduling problem considering the time constraints. This paper proposes a methodology for a joint dispatch of demand response and distributed generation to provide energy and reserve by a virtual power player that operates a distribution network. The optimal schedule minimizes the operation costs and it is obtained using a particle swarm optimization approach, which is compared with a deterministic approach used as reference methodology. The proposed method is applied to a 33-bus distribution network with 32 medium voltage consumers and 66 distributed generation units.
Resumo:
Nesta dissertação pretendeu-se estudar a viabilidade do uso de eletrodiálise com membranas bipolares (BM) na recuperação de ácido clorídrico e de hidróxido de sódio a partir de um efluente industrial que contém 1.4 mol/L de cloreto de sódio. Estas membranas mostraram ser uma ferramenta eficiente para a produção de ácidos e bases a partir do respetivo sal. Foi feita uma seleção de diferentes membranas bipolares (Neosepta, Fumatech e PCA) e aniónicas (PC-SA e PC-ACID 60) na tentativa de encontrar a combinação mais adequada para o tratamento do efluente. Dependendo do critério, o melhor arranjo de membranas é o uso de PC-ACID 60 (membrana aniónica), PC-SK (membrana catiónica) e membranas bipolares do tipo Neosepta para maior pureza dos produtos; membranas bipolares Fumatech para maior eficiência de dessalinização e membranas bipolares PCA para um maior grau de dessalinização. Tecnologicamente foi possível obter uma dessalinização de 99.8% em quatro horas de funcionamento em modo batch com recirculação de todas as correntes. Independentemente da combinação usada é recomendável que o processo seja parado quando a densidade de corrente deixa de ser máxima, 781 A/m2. Assim é possível evitar o aumento de impurezas nos produtos, contra difusão, descida instantânea do pH e uma dessalinização pouco eficiente. A nível piloto o principal fornecedor de membranas e unidade de tratamento “stack” é a marca alemã PCA. Sendo assim realizaram-se ensaios de repetibilidade, contra difusão, avaliação económica e upscaling utilizando as membranas bipolares PCA. A nível económico estudou-se o uso de dois tipos de unidades de tratamento; EDQ 380 e EDQ 1600, para diferentes níveis de dessalinização (50, 75 e 80%). Tendo em conta a otimização económica, é recomendável uma dessalinização máxima de 80%, uma vez que a eficiência de processo a este ponto é de 40%. A aplicação do método com a unidade EDQ 1600 para uma dessalinização de 50% é a mais vantajosa economicamente, com custos de 16 €/m3 de efluente tratado ou 0,78 €/kg Cl- removido. O número de unidades necessárias é 4 posicionados em série.
Resumo:
An 80 years old man suffered a cardiac arrest shortly after arrival to his local health department. Basic Life Support was started promptly and nine minutes later, on evaluation by an Advanced Life Support team, the victim was defibrillated with a 200J shock. When orotracheal intubation was attempted, masseter muscle contraction was noticed: on reevaluation, the victim had pulse and spontaneous breathing.Thirty minutes later, the patient had been transferred to an emergency department. As he complained of chest pain, the ECG showed a ST segment depression in leads V4 to V6 and laboratory tests showed cardiac troponine I slightly elevated. A coronary angiography was performed urgently: significant left main plus three vessel coronary artery disease was disclosed.Eighteen hours after the cardiac arrest, a quadruple coronary artery bypass grafting operation was undertaken. During surgery, a fresh thrombus was removed from the middle left anterior descendent artery. Post-operative course was uneventful and the patient was discharged seven days after the procedure. Twenty four months later, he remains asymptomatic.In this case, the immediate call for the Advanced Life Support team, prompt basic life support and the successful defibrillation, altogether, contributed for the full recovery. Furthermore, the swiftness in the detection and treatment of the acute reversible cause (myocardial ischemia in this case) was crucial for long-term prognosis.
Resumo:
Thesis submitted to the Universidade Nova de Lisboa, Faculdade de Ciências e Tecnologia for the degree of Doctor of Philosophy in Environmental Engineering
Resumo:
The purpose of this study was to evaluate the influence of variables in a flotation technique for the recovery of Toxocara canis eggs from soil. The trials were done under standardized conditions on one gram of previously sterilized soil samples contaminated with 200 eggs of T. canis. The following variables were evaluated in serial steps: sieving; type of wash; time of stirring; resuspension of sediment; solution flotation. Centrifuge-flotation in sodium nitrate (d = 1.20 g/cm³) was adopted as an initial technique, using Tween 80 (0.2%) and decinormal sodium hydroxide as solutions for washing the samples. Ten tests were done to compare the variables, using counting in triplicate. The sieving of the material reduced significantly the recovery of eggs (p < 0.001) and the number of eggs recovered was higher when the sediment was resuspended (p < 0.05). After standardization, flotation solutions sodium chloride, zinc sulfate, sodium dichromate, magnesium sulfate, and sodium nitrate (d = 1.20g/cm³) were compared. The best results were obtained by using zinc sulfate solution. In conclusion, the chances of recovering T. canis eggs from samples using flotation solutions can be increased by washing of soil twice using distilled water, and resuspension of sediment. On the other hand, the sieving procedure can drastically reduce the number of eggs.
Resumo:
O crescente aumento do consumo energético das sociedades desenvolvidas e emergentes, motivado pelo progresso económico e social, tem induzido a procura de alternativas focalizadas nas energias renováveis, que possam contribuir para assegurar o fornecimento de energia sem agravar o consumo de combustíveis fósseis e a emissão de gases com efeito de estufa. Nesse sentido, a produção de energia eléctrica a partir do gás metano resultante da estabilização anaeróbia de efluentes tem vindo a ser estudada e praticada desde finais do século XIX, tendo assumido maior expressão a partir dos anos 70 do século XX, na sequência das primeiras crises petrolíferas. As instalações agropecuárias reúnem dois fatores chave para o sucesso do aproveitamento energético do biogás produzido no tratamento dos efluentes: por um lado, produzem matéria-prima com potencial energético – dejeto animal com um potencial enorme de criação de biogás quando procedido de tratamento anaeróbio - e, por outro, necessitam de energia eléctrica para o funcionamento dos equipamentos electromecânicos e de calor para a manutenção das instalações. A valorização energética do biogás produzido na estabilização anaeróbia dos efluentes agro-pecuários, para além de permitir obter um retorno financeiro, que contribui para o equilíbrio dos custos de investimento e de exploração, contribui igualmente para a redução das emissões de gases com efeito de estufa, como o dióxido de carbono e o metano, e para a segurança de abastecimento energético à instalação, na medida em que assegura a alimentação de energia eléctrica em caso de falha no fornecimento pela rede nacional. A presente dissertação apresenta um contributo para estudos a desenvolver por proprietários de agropecuárias, cooperativas regionais do setor da agropecuária, empresas de projecto e estudantes de Engenharia, constituído por uma compilação da informação mais relevante associada à estabilização anaeróbia de efluentes e à valorização energética do biogás produzido. Com base em informação referente ao número real de animais existentes em Portugal, este trabalho pretende fazer ver a essas entidades que o aproveitamento energético do biogás é viável e útil para o país. Com a criação de uma aplicação informática de análise económica de investimento, provar que o investimento em pequenas propriedades, com apenas 80 cabeças normais, pode obter um retorno financeiro razoável, com um prazo de recuperação do investimento bastante baixo, aproveitando um recurso que caso contrário será desperdiçado e poluirá o ambiente.
Resumo:
Dissertação para obtenção do Grau de Mestre em Engenharia do Ambiente, perfil Engenharia Sanitária
Resumo:
SUMMARY The efficacy of nitazoxanide (NTZ) against toxocariasis was investigated in an experimental murine model and results were compared to those obtained using mebendazole. Sixty male BALB/c mice, aged six to eight weeks-old, were divided into groups of 10 each; fifty were orally infected with 300 larvaed eggs of T. canisand grouped as follows, G I: infected untreated mice; G II: infected mice treated with MBZ (15 mg/kg/day) 10 days postinfection (dpi); G III: infected mice treated with NTZ (20 mg/kg/day) 10 dpi; G IV: infected mice treated with MBZ 60 dpi; G V: infected mice treated with NTZ 60 dpi; GVI: control group comprising uninfected mice. Mice were bled via retro-orbital plexus on four occasions between 30 and 120 dpi. Sera were processed using the ELISA technique to detect IgG anti- Toxocaraantibodies. At 120 dpi, mice were sacrificed for larval recovery in the CNS, liver, lungs, kidneys, eyes and carcass. Results showed similar levels of anti- ToxocaraIgG antibodies among mice infected but not submitted to treatment and groups treated with MBZ or NTZ, 10 and 60 dpi. Larval recovery showed similar values in groups treated with NTZ and MBZ 10 dpi. MBZ showed better efficacy 60 dpi, with a 72.6% reduction in the parasite load compared with NTZ, which showed only 46.5% reduction. We conclude that administration of these anthelmintics did not modify the humoral response in experimental infection by T. canis. No parasitological cure was observed with either drug; however, a greater reduction in parasite load was achieved following treatment with MBZ.
Resumo:
Neurocardiogenic syncope (NCS) is a common clinical entity resulting from an excessive reflex autonomic response, particularly during orthostatism. Treatment options are controversial and of limited effectiveness. Tilt training (TT) is a promising option to treat these patients. However, its mechanism of action and clinical impact remain unclear. OBJECTIVE: To characterize hemodynamic and autonomic responses during a TT program in patients with NCS refractory to conventional measures. METHODS: We studied 28 patients (50% male, mean age 41±14 years) without structural heart disease, with NCS documented by tilt testing. The TT program included 9 tilt sessions (3 times a week, 30 min) (60° - 6 sessions, 70° - 3 sessions), under ECG and blood pressure monitoring combined with home orthostatic self-training and 10° head-up during sleep. Systolic volume, cardiac output, total peripheral resistance, baroreflex sensitivity and heart-rate variability were computed. Patients were reassessed at 1 month and every 6 months for a maximum of 36 months (24±12 months). RESULTS: Over the course of the TT program there was a significant increase in total peripheral resistance (1485±225 vs. 1591±187 dyn·s·cm(-5), p<0.05), with a decrease in standard deviation (206±60 vs. 150±42, p<0.05). During follow-up, syncope recurred in five patients (19%), with a significant reduction in the number of episodes (4.0±3.2/patient in the 12 months before TT vs. 1.4±0.8/patient post-TT, p<0.05). CONCLUSION: In refractory NCS, TT may be an effective therapeutic option, with long-term benefits. These results appear to be due to an increase in vasoconstrictor reserve combined with a reduction in its variance.
Resumo:
Dissertation submitted in partial fulfillment of the requirements for the Degree of Master of Science in Geospatial Technologies.
Resumo:
Energy conservation in chemotrophic anaerobic bacteria is achieved by two possible processes, substrate level phosphorylation (SLP) and electron transfer phosphorylation (ETP). This second mechanism, also known as respiration, involves chemiosmotic coupling. However, a third mechanism for energy coupling was recently proposed: the flavin-based electron bifurcation (FBEB). (...)
Resumo:
This project aims to delineate recovery strategies for a Portuguese Bank, as a way to increase its preparedness towards unexpected disruptive events, thus avoiding an operational crisis escalation. For this purpose, Business Continuity material was studied, a risk assessment performed, a business impact analysis executed and new strategic framework for selecting strategies adopted. In the end, a set of recovery strategies were chosen that better represented the Bank’s appetite for risk, and recommendations given for future improvements.
Resumo:
Natural disasters are events that cause general and widespread destruction of the built environment and are becoming increasingly recurrent. They are a product of vulnerability and community exposure to natural hazards, generating a multitude of social, economic and cultural issues of which the loss of housing and the subsequent need for shelter is one of its major consequences. Nowadays, numerous factors contribute to increased vulnerability and exposure to natural disasters such as climate change with its impacts felt across the globe and which is currently seen as a worldwide threat to the built environment. The abandonment of disaster-affected areas can also push populations to regions where natural hazards are felt more severely. Although several actors in the post-disaster scenario provide for shelter needs and recovery programs, housing is often inadequate and unable to resist the effects of future natural hazards. Resilient housing is commonly not addressed due to the urgency in sheltering affected populations. However, by neglecting risks of exposure in construction, houses become vulnerable and are likely to be damaged or destroyed in future natural hazard events. That being said it becomes fundamental to include resilience criteria, when it comes to housing, which in turn will allow new houses to better withstand the passage of time and natural disasters, in the safest way possible. This master thesis is intended to provide guiding principles to take towards housing recovery after natural disasters, particularly in the form of flood resilient construction, considering floods are responsible for the largest number of natural disasters. To this purpose, the main structures that house affected populations were identified and analyzed in depth. After assessing the risks and damages that flood events can cause in housing, a methodology was proposed for flood resilient housing models, in which there were identified key criteria that housing should meet. The same methodology is based in the US Federal Emergency Management Agency requirements and recommendations in accordance to specific flood zones. Finally, a case study in Maldives – one of the most vulnerable countries to sea level rise resulting from climate change – has been analyzed in light of housing recovery in a post-disaster induced scenario. This analysis was carried out by using the proposed methodology with the intent of assessing the resilience of the newly built housing to floods in the aftermath of the 2004 Indian Ocean Tsunami.
Resumo:
Phosphorus (P) is becoming a scarce element due to the decreasing availability of primary sources. Therefore, recover P from secondary sources, e.g. waste streams, have become extremely important. Sewage sludge ash (SSA) is a reliable secondary source of P. The use of SSAs as a direct fertilizer has very restricted legislation due to the presence of inorganic contaminants. Furthermore, the P present in SSAs is not in a plant-available form. The electrodialytic (ED) process is one of the methods under development to recover P and simultaneously remove heavy metals. The present work aimed to optimize the P recovery through a 2 compartment electrodialytic cell. The research was divided in three independent phases. In the first phase, ED experiments were carried out for two SSAs from different seasons, varying the duration of the ED process (2, 4, 6 and 9 days). During the ED treatment the SSA was suspended in distilled water in the anolyte, which was separated from the catholyte by a cation exchange membrane. From both ashes 90% of P was successfully extracted after 6 days of treatment. Regarding the heavy metals removal, one of the SSAs had a better removal than the other. Therefore, it was possible to conclude that SSAs from different seasons can be submitted to ED process under the same parameters. In the second phase, the two SSAs were exposed to humidity and air prior to ED, in order to carbonate them. Although this procedure was not successful, ED experiments were carried out varying the duration of the treatment (2 and 6 days) and the period of air exposure that SSAs were submitted to (7, 14 and 30 days). After 6 days of treatment and 30 days of air exposure, 90% of phosphorus was successfully extracted from both ashes. No differences were identified between carbonated and non-carbonated SSAs. Thus, SSAs that were exposed to the air and humidity, e.g. SSAs stored for 30 days in an open deposit, can be treated under the same parameters as the SSAs directly collected from the incineration process. In the third phase, ED experiments were carried out during 6 days varying the stirring time (0, 1, 2 and 4 h/day) in order to investigate if energy can be saved on the stirring process. After 6 days of treatment and 4 h/day stirring, 80% and 90% of P was successfully extracted from SSA-A and SSA-B, respectively. This value is very similar to the one obtained for 6 days of treatment stirring 24 h/day.
Resumo:
There is a need to develop viable techniques for removal and recovery organic and inorganic compounds from environmental matrices, due to their ecotoxicity, regulatory obligations or potential supplies as secondary materials. In this dissertation, electro –removal and –recovery techniques were applied to five different contaminated environmental matrices aiming phosphorus (P) recovery and/or contaminants removal. In a first phase, the electrokinetic process (EK) was carried out in soils for (i) metalloids and (ii) organic contaminants (OCs) removal. In the case of As and Sb mine contaminated soil, the EK process was additionally coupled with phytotechnologies. In a second phase, the electrodialytic process (ED) was applied to wastes aiming P recovery and simultaneous removal of (iii) toxins from membrane concentrate, (iv) heavy metals from sewage sludge ash (SSA), and (v) OCs from sewage sludge (SS). EK enhanced phytoremediation showed to be viable for the remediation of soils contaminated with metalloids, as although remediation was low, it combines advantages of both technologies while allowing site management. EK also proved to be an effective remediation technology for the removal and degradation of emerging OCs from two types of soil. Aiming P recovery and contaminants removal, different ED cell set-ups were tested. For the membrane concentrates, the best P recovery was achieved in a three compartment (3c) cell, but the highest toxin removal was obtained in a two compartment (2c) cell, placing the matrix in the cathode end. In the case of SSA the best approach for simultaneous P recovery and heavy metals removal was to use a 2c-cell placing the matrix in the anode end. However, for simultaneous P recovery and OCs removal, SS should be placed in the cathode end, in a 2c-cell. Overall, the data support that the selection of the cell design should be done case-by-case.