896 resultados para sources of power


Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Enriquillo and Azuei are saltwater lakes located in a closed water basin in the southwestern region of the island of La Hispaniola, these have been experiencing dramatic changes in total lake-surface area coverage during the period 1980-2012. The size of Lake Enriquillo presented a surface area of approximately 276 km2 in 1984, gradually decreasing to 172 km2 in 1996. The surface area of the lake reached its lowest point in the satellite observation record in 2004, at 165 km2. Then the recent growth of the lake began reaching its 1984 size by 2006. Based on surface area measurement for June and July 2013, Lake Enriquillo has a surface area of ~358 km2. Sumatra sizes at both ends of the record are 116 km2 in 1984 and 134 km2in 2013, an overall 15.8% increase in 30 years. Determining the causes of lake surface area changes is of extreme importance due to its environmental, social, and economic impacts. The overall goal of this study is to quantify the changing water balance in these lakes and their catchment area using satellite and ground observations and a regional atmospheric-hydrologic modeling approach. Data analyses of environmental variables in the region reflect a hydrological unbalance of the lakes due to changing regional hydro-climatic conditions. Historical data show precipitation, land surface temperature and humidity, and sea surface temperature (SST), increasing over region during the past decades. Salinity levels have also been decreasing by more than 30% from previously reported baseline levels. Here we present a summary of the historical data obtained, new sensors deployed in the sourrounding sierras and the lakes, and the integrated modeling exercises. As well as the challenges of gathering, storing, sharing, and analyzing this large volumen of data in a remote location from such a diverse number of sources.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Based on the Heckscher-Ohlin-Vanek model, this paper investigates relative factor abundance in Brazil, as revealed by its international trade. We study two different time periods: one characterized by high trade barriers (1980 to 1985) and the trade liberalization period (1990 to 1995). Two alternative methodologies are used: the estimation of factor intensity regressions on net exports and the direct computation of factor content in net exports. In the factor intensity regression, we incorporate technological changes that might have occurred over time, and those turned out to be significant. Both methods yield the same results: the Brazilian international trade reveals relative abundance in capital, land and unskilled labor, and scarcity in skilled labor, with qualitatively equivalent results for the two time periods studied.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper studies the joint determination of the wage payments period between firms and employees. The aggregate timeseries analysis reaches two conclusions: a) the average payments period keep an equilibrium relationship with the previous inflation peak, this indicates some degree of irreversibility of payments practices. b) the low previous inflation peak .;:;_asticity of ave r age payments periods reveal.s a high degree of rigidity of payments practices.The framework developed in the paper incorporates the fol.l.owing sources of payments practices rigidity: a)interactions between optimal. payments period decisions and optimal. number of trips to the bank. b)the occurrence of Pare to inneficiencies in the bargaining process between firms and empl.oyees due to wage regulation. c) integer restrictions on payments frequencies produced by upper bounds on the payments period. The empirical. part of the paper assesses the rel.evance of these different sources of payments practices rigidity using Brazil.ian micro data.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Although the existence of spinoff equity gains is well documented, their source remains controversial. Arnong many potential causes, the literature suggests that spinoff equity gains could arise from expected tax benefits, expected takeover premia, operating performance improvement or from refocusing benefits. This paper investigates the link between spinoff announcement and post completion equity gains and post spinoff operating performance changes, takeover activity and refocusing benefits. The results indicate that spinoff announcement retums reflect anticipated takeover premiums as well as expected operating performance gains and refocusing benefits unrelated to operating performance. However, only the parent's operating performance gains are anticipated at the spinoff announcement. We find that post spinoff equity gains are driven mostly by operating performance changes for both parents and spun off subsidiaries. Takeover activity and unrelatedness of business lines between parent and subsidiary expIain littIe of post spinoff equity gains. OveralI, the data suggests that spinoffs equity gains mostly reflect anticipated real economic gains in terms of improved operating performance, and to a lesser extent takeover premium and refocusing benefit.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Salmonellosis is a worldwide disease caused by bacteria of the genus Salmonella. Currently, there are over 2,500 identified serovars of Salmonella. A reduced number of these serovars, about eighty, are implicated in most animals and human diseases. Most cases of salmonellosis in humans are associated with the consumption of contaminated food products such as beef, pork, poultry meat, eggs, vegetables, juices and other kind of foods. It may also be associated with the contact between humans and infected pet animals. Therefore, the chain of human salmonellosis is very complex and in most cases the origin of the infection is difficult to establish. The use of antimicrobial agents to treat and to prevent bacterial infections in humans and animals, as well as as growth promoters in animal production, has favoured the selection and transference of resistance genes between different bacteria, including Salmonella serovars. Many studies have confirmed the role of foods of animal origin as a source of multi drugresistant Salmonella serovars. For this reason, continuous surveillance of these pathogens along the food chain together with the responsible use of antimicrobial agents is necessary.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The present study was carried out with the objective of evaluating the effects of feeding dairy cows with organic or inorganic sources of zinc (Zn), copper (Cu) and selenium (Se) on blood concentrations of these minerals, blood metabolic profiles, nutrient intake and milk yield and composition. Nineteen Holstein cows were selected and randomly assigned to two groups for receiving organic (n = 9) or inorganic (n = 10) sources of Zn, Cu and Se from 60 days before the expected date of calving to 80 days of lactation. Samples of feed, orts and milk were collected for analysis. Body condition score (BCS) was determined and blood samples were collected for analysis of Zn, Cu and Se concentrations, as well as for metabolic profile. Supplying organic or inorganic sources of Zn, Cu, and Se did not affect dry matter and nutrient intake, blood metabolic profile, milk yield and composition, plasma concentration of these minerals, and BCS or change the BCS in cows from 60 days before the expected date of calving to 80 days of lactation. An effect of time was observed on all feed intake variables, plasma concentrations of Zn and Se, milk yield, milk protein content, BCS and change in BCS.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The conventional Newton and fast decoupled power flow (FDPF) methods have been considered inadequate to obtain the maximum loading point of power systems due to ill-conditioning problems at and near this critical point. It is well known that the PV and Q-theta decoupling assumptions of the fast decoupled power flow formulation no longer hold in the vicinity of the critical point. Moreover, the Jacobian matrix of the Newton method becomes singular at this point. However, the maximum loading point can be efficiently computed through parameterization techniques of continuation methods. In this paper it is shown that by using either theta or V as a parameter, the new fast decoupled power flow versions (XB and BX) become adequate for the computation of the maximum loading point only with a few small modifications. The possible use of reactive power injection in a selected PV bus (Q(PV)) as continuation parameter (mu) for the computation of the maximum loading point is also shown. A trivial secant predictor, the modified zero-order polynomial which uses the current solution and a fixed increment in the parameter (V, theta, or mu) as an estimate for the next solution, is used in predictor step. These new versions are compared to each other with the purpose of pointing out their features, as well as the influence of reactive power and transformer tap limits. The results obtained with the new approach for the IEEE test systems (14, 30, 57 and 118 buses) are presented and discussed in the companion paper. The results show that the characteristics of the conventional method are enhanced and the region of convergence around the singular solution is enlarged. In addition, it is shown that parameters can be switched during the tracing process in order to efficiently determine all the PV curve points with few iterations. (C) 2003 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

One of the important issues about using renewable energy is the integration of dispersed generation in the distribution networks. Previous experience has shown that the integration of dispersed generation can improve voltage profile in the network, decrease loss, etc. but can create safety and technical problems as well. This work report the application of the instantaneous space phasors and the instantaneous complex power in observing performances of the distribution networks with dispersed generators in steady state. New IEEE apparent power definition, the so-called Buchholz-Goodhue effective apparent power, as well as new proposed power quality (oscillation) index in the three-phase distribution systems with unbalanced loads and dispersed generators, are applied. Results obtained from several case studies using IEEE 34 nodes test network are presented and discussed. (C) 2006 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The parameterized fast decoupled power flow (PFDPF), versions XB and BX, using either theta or V as a parameter have been proposed by the authors in Part I of this paper. The use of reactive power injection of a selected PVbus (Q(PV)) as the continuation parameter for the computation of the maximum loading point (MLP) was also investigated. In this paper, the proposed versions obtained only with small modifications of the conventional one are used for the computation of the MLP of IEEE test systems (14, 30, 57 and 118 buses). These new versions are compared to each other with the purpose of pointing out their features, as well as the influence of reactive power and transformer tap limits. The results obtained with the new approaches are presented and discussed. The results show that the characteristics of the conventional FDPF method are enhanced and the region of convergence around the singular solution is enlarged. In addition, it is shown that these versions can be switched during the tracing process in order to efficiently determine all the PV curve points with few iterations. A trivial secant predictor, the modified zero-order polynomial, which uses the current solution and a fixed increment in the parameter (V, theta, or mu) as an estimate for the next solution, is used for the predictor step. (C) 2003 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work presents the application of the Decentralized Modal Control method for pole placement in multimachine power systems utilizing FACTS (Flexible AC Transmission Systems), STATCOM (Static Synchronous Compensator) and UPFC (Unified Power Flow Controller) devices. For this, these devices are equipped with supplementary damping controllers, denominated POD ( Power Oscillation Damping), achieving a coordinated project with local controllers (Power System Stabilizers - PSS). Comparative analysis on the function of damping of the FACTS, STATCOM and UPFC is performed using the New England System that has 10 generators, 39 buses and 46 transmission lines. (c) 2011 Elsevier Ltd. All rights reserved.