909 resultados para self evaluation


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Background and Objectives. The adhesion of dental materials is important for the success of treatment. The aim of this study is to evaluate the bond strength of a composite resin applied with a self-etching adhesive system in different dentins after irradiation with Er:YAG and Nd:YAG lasers, observing their morphologic pattern using Scanning Electronic Microscopy (SEM). Materials and Methods. The buccal surface of 72 bovine incisors was worn until exposure of medium depth dentin. The specimens were divided into three groups; GI: normal, GII: demineralized and GIII: hypermineralized dentin. These were also divided into two subgroups; A-irradiated for 30 s with Er:YAG laser in noncontact mode at 40 mJ and 6 Hz and B- irradiated for 30 s with Nd:YAG laser in contact mode at 60 mJ and 10 Hz. The adhesive system Clearfil SE. Bond (Kuraray) and composite resin Tetric Ceram (Vivadent) were applied on the irradiated area by the incremental technique. After storage for 24 h in distilled water at 37 degrees C, the specimens were submitted to the shear strength test in a universal testing machine (EMIC) at a crosshead speed of 1.0 mm/min. Other specimens were made to be analyzed by SEM. Results. The results were statistically analyzed by Analysis of Variance and the Tukey test. Regardless of the type of dentin, the bond strength of specimens irradiated with the Nd:YAG laser (8,94 +/- 2,07) was higher compared to specimens irradiated with the Er:YAG laser (7,03 +/- 2,47); the highest bond strength was obtained for the group of hypermineralized dentin irradiated with the Nd:YAG laser. The SEM analysis showed that the Er:YAG laser caused opening of tubules and the Nd:YAG laser produced areas of fusion as well as regions of opening of dentinal tubules. Conclusions. The dentin showed different morphological patterns and the laser promote alterations on their surfaces, influencing the bond strength of the composite resin. (C) 2010 Laser Institute of America.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This article compares the efficiency of induced polarization (IP) and resistivity in characterizing a contamination plume due to landfill leakage in a typical tropical environment. The resistivity survey revealed denser electrical current flow that induced lower resistivity values due to the high ionic content. The increased ionic concentration diminished the distance of the ionic charges close to the membrane, causing a decrease in the IP phenomena. In addition, the self-potential (SP) method was used to characterize the preferential flow direction of the area. The SP method proved to be effective at determining the flow direction; it is also fast and economical. In this study, the resistivity results were better correlated with the presence of contamination (lower resistivity) than the IP (lower chargeability) data.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The present clinical study aimed to assess the postoperative sensitivity (POS) after 48 hours and seven days in occlusal restorations bonded with three different adhesive systems, two of them containing glutaraldehyde. The restorative procedures were performed using the three-step etch-and-rinse Adper SBMP-Plus adhesive (SBMP), the two-step etch-and-rinse Gluma Comfort One Bond + Desensitizer adhesive (GC+D) and the all-in-one self-etching/priming I Bond (IB) adhesive, which also has glutaraldehyde in its formula. All cavities were restored with Filtek Supreme nanoparticle composite resin. After 48 hours and seven days the patients were recalled and the postoperative sensitivity evaluated. The data analyzed by non-parametric Friedman test showed no significant differences in POS among the three tested groups after 48 hours and seven days.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

OBJECTIVE: to evaluate the structure, process and results of the Capillary Blood Glucose Self-monitoring Program in a Brazilian city. METHOD: epidemiological, cross-sectional study. The methodological framework of Donabedian was used to construct indicators of structure, process and outcome. A random sample (n = 288) of users enrolled and 96 health professionals who worked in the program was studied. Two questionnaires were used that were constructed for this study, one for professionals and one for users, both containing data for the evaluation of structure, process and outcome. Anthropometric measures and laboratory results were collected by consulting the patients' health records. The analysis involved descriptive statistics. RESULTS: most of the professionals were not qualified to work in the program and were not knowledgeable about the set of criteria for patient registration. None of the patients received complete and correct orientations about the program and the percentage with skills to perform conducts autonomously was 10%. As regards the result indicators, 86.4% of the patients and 81.3% of the professionals evaluated the program positively. CONCLUSION: the evaluation indicators designed revealed that one of the main objectives of the program, self-care skills, has not been achieved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The efficacy of postgraduate practical training courses is frequently evaluated by self-assessment instruments. The present study analyses the effect of a basic course in laparoscopic surgery on self-assessed medical competencies.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Bluetooth wireless technology is a robust short-range communications system designed for low power (10 meter range) and low cost. It operates in the 2.4 GHz Industrial Scientific Medical (ISM) band and it employs two techniques for minimizing interference: a frequency hopping scheme which nominally splits the 2.400 - 2.485 GHz band in 79 frequency channels and a time division duplex (TDD) scheme which is used to switch to a new frequency channel on 625 μs boundaries. During normal operation a Bluetooth device will be active on a different frequency channel every 625 μs, thus minimizing the chances of continuous interference impacting the performance of the system. The smallest unit of a Bluetooth network is called a piconet, and can have a maximum of eight nodes. Bluetooth devices must assume one of two roles within a piconet, master or slave, where the master governs quality of service and the frequency hopping schedule within the piconet and the slave follows the master’s schedule. A piconet must have a single master and up to 7 active slaves. By allowing devices to have roles in multiple piconets through time multiplexing, i.e. slave/slave or master/slave, the Bluetooth technology allows for interconnecting multiple piconets into larger networks called scatternets. The Bluetooth technology is explored in the context of enabling ad-hoc networks. The Bluetooth specification provides flexibility in the scatternet formation protocol, outlining only the mechanisms necessary for future protocol implementations. A new protocol for scatternet formation and maintenance - mscat - is presented and its performance is evaluated using a Bluetooth simulator. The free variables manipulated in this study include device activity and the probabilities of devices performing discovery procedures. The relationship between the role a device has in the scatternet and it’s probability of performing discovery was examined and related to the scatternet topology formed. The results show that mscat creates dense network topologies for networks of 30, 50 and 70 nodes. The mscat protocol results in approximately a 33% increase in slaves/piconet and a reduction of approximately 12.5% of average roles/node. For 50 node scenarios the set of parameters which creates the best determined outcome is unconnected node inquiry probability (UP) = 10%, master node inquiry probability (MP) = 80% and slave inquiry probability (SP) = 40%. The mscat protocol extends the Bluetooth specification for formation and maintenance of scatternets in an ad-hoc network.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Most physical education intervention studies on the positive effect of sports on self-concept development have attempted to increase schoolchildren’s self-concept without taking the veridicality of the self-concept into account. The present study investigated whether a 10-week intervention in physical education would lead to an increase not only in the general level of self-concept of endurance and self-concept of strength but also in its veridicality in those who had previously under- or overestimated their abilities. A total of 464 primary schoolchildren (246 boys, 218 girls, Mage = 11.9) either participated in the intervention or served as controls. The intervention group received endurance and strength training during physical education lessons carried out with a consistent individualized teacher frame of reference (iTFR). Results showed that this specific intervention was associated with increases not only in the general level of self-concept but also in its veridicality in under- and overestimators. Results are discussed in terms of didactic methods to promote functional self-concepts in physical education.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

There is a shortage of empirical applications of the capability approach that employ closed survey instruments to assess self-reported capabilities. However, for those few instruments that have been designed and administered through surveys until now, no psychometric properties (reliability, validity, and factor structure) were reported. The purpose of this study is the assessment of the psychometric properties of three new language versions (German, French, and Italian) of an established (English) set of eight self-reported capability items. The set of items is taken from a previously published British study by Anand and van Hees (J Soc Econ 35(2):268–284, 2006). Our sample consists of 17,152 young male adults aged 18–25 years from the three major language regions in Switzerland. The results indicate good reliability of the three language versions. The results from the exploratory factor analyses suggest a one-dimensional factor structure for seven domain specific items. Furthermore, the results from multiple regression analyses suggest that a global summary item on overall capabilities represents a measurement alternative to the set of seven domain specific capability items. Finally, the results confirm the applicability of the closed capability instrument in a large scale survey questionnaire and represent the first attempt to measure self-reported capabilities in Switzerland.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The relationship was explored between a subjective measure of hearing status, derived from a functional self-assessment expressed in terms of ability to hear and understand spoken words, and a comparable objective measure of hearing status, obtained from a speech reception test. The Augmentation Survey of the Health and Nutrition Examination Survey of the National Center for Health Statistics provided the necessary data for a sample of 3059 adults. Using chi-square tests for the subsample with the highest level of objectively assessed hearing status, favorable subjective assessments were found to be significantly associated with higher income, lower age group, higher level of educational attainment, greater psychological adjustment, fewer symptoms of depression, and higher self-ratings of overall health. In a linear regression with self-assessment of hearing status as the dependent variable, less than one-quarter of the variation could be explained by objective status and the six explanatory variables.^

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This study includes an analysis of the applicability of current models used for estimating the mechanical properties of conventional concrete to self-compacting concrete. The mechanical properties evaluated are: modulus of elasticity, tensile strength, and modulus of rupture. An extensive database which included the dosifications and the mechanical properties of 627 mixtures from 138 different references, was used. The models considered are: ACI, EC-2, NZS 3101:2006 (New Zealand code) and the CSA A23.3-04 (Canadian code). The precision in estimating the modulus of elasticity and tensile strength is acceptable for all models; however, all models are less precise in estimating the modulus of rupture.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We have developed a highly pure, self-adjuvanting, triepitopic Group A Streptococcal vaccine based on the lipid core peptide system, a vaccine delivery system incorporating lipidic adjuvant, carrier, and peptide epitopes into a single molecular entity. Vaccine synthesis was performed using native chemical ligation. Due to the attachment of a highly lipophilic adjuvant, addition of 1% (w/v) sodium dodecyl sulfate was necessary to enhance peptide solubility in order to enable ligation. The vaccine was synthesized in three steps to yield a highly pure product (97.7% purity) with an excellent overall yield. Subcutaneous immunization of B10. BR (H-2(k)) mice with the synthesized vaccine, with or without the addition of complete Freund's adjuvant, elicited high serum IgG antibody titers against each of the incorporated peptide epitopes.