885 resultados para quality measurement
Resumo:
Human population growth and increased industrial activity in recent decades have contributed to a range of environmental problems, including the contamination of groundwater and surface water. In order to help in the management of these resources, water quality indices are used as tools to summarize multiple parameters and express them in the form of a single number. The ability to provide both an integrated assessment of changes in environmental variables, as well as performance tracking, has resulted in such indices being increasingly employed in surface water monitoring programs. The aim of this study was to develop an Index for Public Supply Water Quality (IPS) using a fuzzy inference methodology. Linguistic systems generally provide satisfactory tools for qualitative purposes, enabling the inclusion of descriptive variables with reduced loss of individual information. Validation of the technique was achieved by analysis of measurement data obtained for the Sorocaba River, provided by CETESB. The new procedure proved more rigorous, compared to classical IPS. It could be readily applied in the evaluation of other water bodies, or be adjusted to incorporate additional parameters also considered important for the assessment of water quality.
Resumo:
The process of spermatic division and differentiation (spermatogenesis) occurs with intratesticular temperature lower that the corporal temperature and for that is essential that the testicular thermoregulation mechanism occurs properly. For evaluation of the scrotal surface temperature can be used the infrared thermography or testicular sensors, besides that, can be evaluated the blood flux in the spermatic cord through the Doppler ultrasonography. Thus, the aim of this study is to analyze the testicular thermoregulation in adult buffaloes through scrotal thermography and Doppler ultrasound of testicular artery and verify its effect on sperm quality. For that were used seven healthy buffaloes, with age of 3 and 4 years, of the Murrah breed. The animals were subjected to 3 semen collections using artificial vagina, with one day of interval. In addiction, the retal temperature measurement (RT) with dry bulb thermometer, the measurement of scrotal surface temperature (SST) and body surface temperature (BST) through infrared thermography and the pulsatility (PI) and resistivity (RI) index of testicular artery by Doppler ultrasonography, were performed using 2 distinct moments: animals previously placed to shade (M1) and animals subjected to 4 hours of sun (M2). All parameters were compared by T test and the correlations were performed by Pearson test using the In Stat Graph Pad 3 (R) program. The significant level considered was 5%. There was an increase (p<0,05) of RT, SST, SNT and RI in M2. increasing trend was observed (0,05>p>0,01) PI and RI between M1 and M2. There was a low correlation between SST and semen quality. The results of this study allow us to conclude that adult buffaloes have low ability to perform body and testicular thermoregulation in situations of enviromental heat stress. However, this low capacity of testicular temperature maintenance demonstrated no correlation with the sperm kinetic parameters and sperm morphological defects in buffalo spermatozoa.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Body composition has fundamental importance in the quality of life and is a powerful predictor of mortality and morbidity in humans. The identification and monitoring of the amount of body fat have been receiving special attention in aspects related to health promotion, not just for its actions in the prevention and in the control of cardiovascular diseases but also for their induction and association with risk factors, especially in the plasmatic lipid levels and arterial pressure. It was investigated the relationship between body mass index (BMI) and body fat percentage (%BF) by bioelectrical impedance analysis (BIA) with the blood pressure levels (systolic and diastolic) and serum lipids (TC, HDL-c, LDL-c, VLDL-c, TG). In a group of fifty seven women (aged 18 to 26 years old ), obesity was detected in 5 and 19 women by BMI (≥ 30 kg/m2) and %BF (≥ 30%), respectively. BMI and % BF were positively correlated with blood pressure (systolic and diastolic), and highly significant in the obese group by %BF. Moreover, BMI and % BF were significantly correlated with all lipids and lipoprotein fractions VLDL-c and triglyceride, respectively. These results suggest that %BF is a good indicator of “occult obesity” in subjects with normal body mass index. The associated use of BMI and %BF to better evaluate obesity may improve the study of blood pressure levels and serum lipid changes that are commonly associated with obesity.
Resumo:
The objective of this study was to evaluate the fatty acid profile and qualitative characteristics of meat from feedlot young bulls fed ground soybean or ground cottonseed, with or without supplementation of vitamin E. A total of 40 Red Norte young bulls, with an initial average age of 20 months, and an initial average BW of 339 +/- 15 kg, were allotted in a completely randomized design using a 2 x 2 factorial arrangement, with two oilseeds, and daily supplementation or not of 2500 IU of vitamin E. The experimental period was for 84 days, which was preceded by an adaptation period of 28 days. The treatments were ground soybean (SB), ground soybean plus vitamin E (SBE), ground cottonseed (CS) and ground cottonseed plus vitamin E (CSE). The percentage of cottonseed and soybean in the diets (dry matter basis) was 24% and 20%, respectively. Diets were isonitrogenous (13% CP) and presented similar amount of ether extract (6.5%). The animals were slaughtered at average live weight of 464 +/- 15 kg, and samples were taken from the longissimus dorsi muscle for the measurement of fatty acid concentration and the evaluation of lipid oxidation and color of the beef. Before fatty acid extraction, muscle tissue and subcutaneous fat of the longissimus dorsi were separated to analyze fatty acid profile in both tissues. Supplementation of vitamin E did not affect fatty acid concentration, lipid oxidation and color (P > 0.05). Subcutaneous fat from animals fed CS diet had greater C12: 0, C16: 0 and C18: 0 contents (P < 0.03). In addition, CS diets reduced the C18: 1 and C18: 2 cis-9, trans-11 contents in subcutaneous fat (P < 0.05). The muscle from animals fed CS tended to higher C16: 0 and C18: 0 contents (P < 0.11), and decreased C18: 1, C18: 2 cis-9, trans-11 and C18: 3 contents (P < 0.05) compared with SB. The Delta(9)-desaturase index was greater in muscle from animals fed SB (P < 0.01). At 42 days of age, meat from cattle fed SB had a greater lipid oxidation rate (P < 0.05). Meat from animals fed SB diets had less lightness and redness indices than meat from animals fed CS diets after 14 days of age. In conclusion, the addition of ground cottonseed in the finishing diets did increase the saturated fatty acid content of the longissimus dorsi. However, animals fed cottonseed exhibited greater lightness and redness of beef. In this study, the addition of vitamin E did not affect qualitative characteristics of meat.
Resumo:
Increased railroad traffic volumes, speeds, and axle loads have created a need to better measure track quality. Previous research has indicated that the vertical track deflection provides a meaningful indicator of track integrity. The measured deflection can be related to the bending stresses in the rail as well as characterize the mechanical response of the track. This investigation summarizes the simulation, analysis and development of a measurement system at the University of Nebraska (UNL) to measure vertical track deflection in real-time from a car moving at revenue speeds. The UNL system operates continuously over long distances and in revenue service. Using a camera and two line lasers, the system establishes three points of the rail shape beneath the loaded wheels and over a distance of 10 ft. The resulting rail shape can then be related to the actual bending stress in the rail and estimate the track support through beam theory. Finite element simulations are used to characterize the track response as related to the UNL measurement system. The results of field tests using bondable resistance strain gages illustrate the system’s capability of approximating the actual rail bending stresses under load.
Resumo:
Evaluations of measurement invariance provide essential construct validity evidence. However, the quality of such evidence is partly dependent upon the validity of the resulting statistical conclusions. The presence of Type I or Type II errors can render measurement invariance conclusions meaningless. The purpose of this study was to determine the effects of categorization and censoring on the behavior of the chi-square/likelihood ratio test statistic and two alternative fit indices (CFI and RMSEA) under the context of evaluating measurement invariance. Monte Carlo simulation was used to examine Type I error and power rates for the (a) overall test statistic/fit indices, and (b) change in test statistic/fit indices. Data were generated according to a multiple-group single-factor CFA model across 40 conditions that varied by sample size, strength of item factor loadings, and categorization thresholds. Seven different combinations of model estimators (ML, Yuan-Bentler scaled ML, and WLSMV) and specified measurement scales (continuous, censored, and categorical) were used to analyze each of the simulation conditions. As hypothesized, non-normality increased Type I error rates for the continuous scale of measurement and did not affect error rates for the categorical scale of measurement. Maximum likelihood estimation combined with a categorical scale of measurement resulted in more correct statistical conclusions than the other analysis combinations. For the continuous and censored scales of measurement, the Yuan-Bentler scaled ML resulted in more correct conclusions than normal-theory ML. The censored measurement scale did not offer any advantages over the continuous measurement scale. Comparing across fit statistics and indices, the chi-square-based test statistics were preferred over the alternative fit indices, and ΔRMSEA was preferred over ΔCFI. Results from this study should be used to inform the modeling decisions of applied researchers. However, no single analysis combination can be recommended for all situations. Therefore, it is essential that researchers consider the context and purpose of their analyses.
Resumo:
The study analyzed the correlations among the different factors of subjective well-being (SWB) using a sample of 106 married people with an average of 16.11 years of marriage. The following instruments were used: Sociodemographic Questionnaire, Socioeconomic Questionnaire, and Subjective Well-being Scale (SWBS). Data analyses were conducted using the Software R and a multivariate model to understand the correlations among the factors of the SWBS. All factors of the SWBS were significantly inter-correlated, which confirm the results of the scale validation study. Future studies are necessary to evaluate the SWB in couples (dyads), which can help to understand whether this concept is influenced by the spouse or only by the marital status.
Resumo:
'Objectives: To analyse the validity of the Brazilian versions of OHIP-EDENT and GOHAI as assessment tools of edentulous subjects' OHRQoL. Background: Inventories for measuring oral health-related quality of life (OHRQoL) are important in clinical studies regarding oral rehabilitation. However, there is a need for comprehensive validation after translation into different cultural settings. Materials and methods: The sample comprised of 100 complete denture wearers (29 men, 71 women, mean age of 65.2 +/- 9.9 years). The associations between each OHRQoL inventory and other variables served as measurements of construct validity. Data analysis comprised the Spearman correlation test as well as multiple regression using the OHRQoL inventories as dependent variables and the other scales as determinants. Results: Both OHRQoL inventories showed good correlation with denture satisfaction, whereas lower correlation coefficients were found among the inventories and the HAD subscales. Denture satisfaction alone explained 48% and 39% of the variance found for the OHIP-EDENT and GOHAI, respectively, as assessed by multiple regression. A smaller effect was found for OHIP-EDENT. Conclusion: Both OHIP-EDENT and GOHAI showed good construct validity for measurement of OHRQoL of edentulous subjects.
Resumo:
Determination of the utility harmonic impedance based on measurements is a significant task for utility power-quality improvement and management. Compared to those well-established, accurate invasive methods, the noninvasive methods are more desirable since they work with natural variations of the loads connected to the point of common coupling (PCC), so that no intentional disturbance is needed. However, the accuracy of these methods has to be improved. In this context, this paper first points out that the critical problem of the noninvasive methods is how to select the measurements that can be used with confidence for utility harmonic impedance calculation. Then, this paper presents a new measurement technique which is based on the complex data-based least-square regression, combined with two techniques of data selection. Simulation and field test results show that the proposed noninvasive method is practical and robust so that it can be used with confidence to determine the utility harmonic impedances.
Resumo:
Primary stability of stems in cementless total hip replacements is recognized to play a critical role for long-term survival and thus for the success of the overall surgical procedure. In Literature, several studies addressed this important issue. Different approaches have been explored aiming to evaluate the extent of stability achieved during surgery. Some of these are in-vitro protocols while other tools are coinceived for the post-operative assessment of prosthesis migration relative to the host bone. In vitro protocols reported in the literature are not exportable to the operating room. Anyway most of them show a good overall accuracy. The RSA, EBRA and the radiographic analysis are currently used to check the healing process of the implanted femur at different follow-ups, evaluating implant migration, occurance of bone resorption or osteolysis at the interface. These methods are important for follow up and clinical study but do not assist the surgeon during implantation. At the time I started my Ph.D Study in Bioengineering, only one study had been undertaken to measure stability intra-operatively. No follow-up was presented to describe further results obtained with that device. In this scenario, it was believed that an instrument that could measure intra-operatively the stability achieved by an implanted stem would consistently improve the rate of success. This instrument should be accurate and should give to the surgeon during implantation a quick answer concerning the stability of the implanted stem. With this aim, an intra-operative device was designed, developed and validated. The device is meant to help the surgeon to decide how much to press-fit the implant. It is essentially made of a torsional load cell, able to measure the extent of torque applied by the surgeon to test primary stability, an angular sensor that measure the relative angular displacement between stem and femur, a rigid connector that enable connecting the device to the stem, and all the electronics for signals conditioning. The device was successfully validated in-vitro, showing a good overall accuracy in discriminating stable from unstable implants. Repeatability tests showed that the device was reliable. A calibration procedure was then performed in order to convert the angular readout into a linear displacement measurement, which is an information clinically relevant and simple to read in real-time by the surgeon. The second study reported in my thesis, concerns the evaluation of the possibility to have predictive information regarding the primary stability of a cementless stem, by measuring the micromotion of the last rasp used by the surgeon to prepare the femoral canal. This information would be really useful to the surgeon, who could check prior to the implantation process if the planned stem size can achieve a sufficient degree of primary stability, under optimal press fitting conditions. An intra-operative tool was developed to this aim. It was derived from a previously validated device, which was adapted for the specific purpose. The device is able to measure the relative micromotion between the femur and the rasp, when a torsional load is applied. An in-vitro protocol was developed and validated on both composite and cadaveric specimens. High correlation was observed between one of the parameters extracted form the acquisitions made on the rasp and the stability of the corresponding stem, when optimally press-fitted by the surgeon. After tuning in-vitro the protocol as in a closed loop, verification was made on two hip patients, confirming the results obtained in-vitro and highlighting the independence of the rasp indicator from the bone quality, anatomy and preserving conditions of the tested specimens, and from the sharpening of the rasp blades. The third study is related to an approach that have been recently explored in the orthopaedic community, but that was already in use in other scientific fields. It is based on the vibration analysis technique. This method has been successfully used to investigate the mechanical properties of the bone and its application to evaluate the extent of fixation of dental implants has been explored, even if its validity in this field is still under discussion. Several studies have been published recently on the stability assessment of hip implants by vibration analysis. The aim of the reported study was to develop and validate a prototype device based on the vibration analysis technique to measure intra-operatively the extent of implant stability. The expected advantages of a vibration-based device are easier clinical use, smaller dimensions and minor overall cost with respect to other devices based on direct micromotion measurement. The prototype developed consists of a piezoelectric exciter connected to the stem and an accelerometer attached to the femur. Preliminary tests were performed on four composite femurs implanted with a conventional stem. The results showed that the input signal was repeatable and the output could be recorded accurately. The fourth study concerns the application of the device based on the vibration analysis technique to several cases, considering both composite and cadaveric specimens. Different degrees of bone quality were tested, as well as different femur anatomies and several levels of press-fitting were considered. The aim of the study was to verify if it is possible to discriminate between stable and quasi-stable implants, because this is the most challenging detection for the surgeon in the operation room. Moreover, it was possible to validate the measurement protocol by comparing the results of the acquisitions made with the vibration-based tool to two reference measurements made by means of a validated technique, and a validated device. The results highlighted that the most sensitive parameter to stability is the shift in resonance frequency of the stem-bone system, showing high correlation with residual micromotion on all the tested specimens. Thus, it seems possible to discriminate between many levels of stability, from the grossly loosened implant, through the quasi-stable implants, to the definitely stable one. Finally, an additional study was performed on a different type of hip prosthesis, which has recently gained great interest thus becoming fairly popular in some countries in the last few years: the hip resurfacing prosthesis. The study was motivated by the following rationale: although bone-prosthesis micromotion is known to influence the stability of total hip replacement, its effect on the outcome of resurfacing implants has not been investigated in-vitro yet, but only clinically. Thus the work was aimed at verifying if it was possible to apply to the resurfacing prosthesis one of the intraoperative devices just validated for the measurement of the micromotion in the resurfacing implants. To do that, a preliminary study was performed in order to evaluate the extent of migration and the typical elastic movement for an epiphyseal prosthesis. An in-vitro procedure was developed to measure micromotions of resurfacing implants. This included a set of in-vitro loading scenarios that covers the range of directions covered by hip resultant forces in the most typical motor-tasks. The applicability of the protocol was assessed on two different commercial designs and on different head sizes. The repeatability and reproducibility were excellent (comparable to the best previously published protocols for standard cemented hip stems). Results showed that the procedure is accurate enough to detect micromotions of the order of few microns. The protocol proposed was thus completely validated. The results of the study demonstrated that the application of an intra-operative device to the resurfacing implants is not necessary, as the typical micromovement associated to this type of prosthesis could be considered negligible and thus not critical for the stabilization process. Concluding, four intra-operative tools have been developed and fully validated during these three years of research activity. The use in the clinical setting was tested for one of the devices, which could be used right now by the surgeon to evaluate the degree of stability achieved through the press-fitting procedure. The tool adapted to be used on the rasp was a good predictor of the stability of the stem. Thus it could be useful for the surgeon while checking if the pre-operative planning was correct. The device based on the vibration technique showed great accuracy, small dimensions, and thus has a great potential to become an instrument appreciated by the surgeon. It still need a clinical evaluation, and must be industrialized as well. The in-vitro tool worked very well, and can be applied for assessing resurfacing implants pre-clinically.
Resumo:
The human movement analysis (HMA) aims to measure the abilities of a subject to stand or to walk. In the field of HMA, tests are daily performed in research laboratories, hospitals and clinics, aiming to diagnose a disease, distinguish between disease entities, monitor the progress of a treatment and predict the outcome of an intervention [Brand and Crowninshield, 1981; Brand, 1987; Baker, 2006]. To achieve these purposes, clinicians and researchers use measurement devices, like force platforms, stereophotogrammetric systems, accelerometers, baropodometric insoles, etc. This thesis focus on the force platform (FP) and in particular on the quality assessment of the FP data. The principal objective of our work was the design and the experimental validation of a portable system for the in situ calibration of FPs. The thesis is structured as follows: Chapter 1. Description of the physical principles used for the functioning of a FP: how these principles are used to create force transducers, such as strain gauges and piezoelectrics transducers. Then, description of the two category of FPs, three- and six-component, the signals acquisition (hardware structure), and the signals calibration. Finally, a brief description of the use of FPs in HMA, for balance or gait analysis. Chapter 2. Description of the inverse dynamics, the most common method used in the field of HMA. This method uses the signals measured by a FP to estimate kinetic quantities, such as joint forces and moments. The measures of these variables can not be taken directly, unless very invasive techniques; consequently these variables can only be estimated using indirect techniques, as the inverse dynamics. Finally, a brief description of the sources of error, present in the gait analysis. Chapter 3. State of the art in the FP calibration. The selected literature is divided in sections, each section describes: systems for the periodic control of the FP accuracy; systems for the error reduction in the FP signals; systems and procedures for the construction of a FP. In particular is detailed described a calibration system designed by our group, based on the theoretical method proposed by ?. This system was the “starting point” for the new system presented in this thesis. Chapter 4. Description of the new system, divided in its parts: 1) the algorithm; 2) the device; and 3) the calibration procedure, for the correct performing of the calibration process. The algorithm characteristics were optimized by a simulation approach, the results are here presented. In addiction, the different versions of the device are described. Chapter 5. Experimental validation of the new system, achieved by testing it on 4 commercial FPs. The effectiveness of the calibration was verified by measuring, before and after calibration, the accuracy of the FPs in measuring the center of pressure of an applied force. The new system can estimate local and global calibration matrices; by local and global calibration matrices, the non–linearity of the FPs was quantified and locally compensated. Further, a non–linear calibration is proposed. This calibration compensates the non– linear effect in the FP functioning, due to the bending of its upper plate. The experimental results are presented. Chapter 6. Influence of the FP calibration on the estimation of kinetic quantities, with the inverse dynamics approach. Chapter 7. The conclusions of this thesis are presented: need of a calibration of FPs and consequential enhancement in the kinetic data quality. Appendix: Calibration of the LC used in the presented system. Different calibration set–up of a 3D force transducer are presented, and is proposed the optimal set–up, with particular attention to the compensation of non–linearities. The optimal set–up is verified by experimental results.
Resumo:
Flicker is a power quality phenomenon that applies to cycle instability of light intensity resulting from supply voltage fluctuation, which, in turn can be caused by disturbances introduced during power generation, transmission or distribution. The standard EN 61000-4-15 which has been recently adopted also by the IEEE as IEEE Standard 1453 relies on the analysis of the supply voltage which is processed according to a suitable model of the lamp – human eye – brain chain. As for the lamp, an incandescent 60 W, 230 V, 50 Hz source is assumed. As far as the human eye – brain model is concerned, it is represented by the so-called flicker curve. Such a curve was determined several years ago by statistically analyzing the results of tests where people were subjected to flicker with different combinations of magnitude and frequency. The limitations of this standard approach to flicker evaluation are essentially two. First, the provided index of annoyance Pst can be related to an actual tiredness of the human visual system only if such an incandescent lamp is used. Moreover, the implemented response to flicker is “subjective” given that it relies on the people answers about their feelings. In the last 15 years, many scientific contributions have tackled these issues by investigating the possibility to develop a novel model of the eye-brain response to flicker and overcome the strict dependence of the standard on the kind of the light source. In this light of fact, this thesis is aimed at presenting an important contribution for a new Flickermeter. An improved visual system model using a physiological parameter that is the mean value of the pupil diameter, has been presented, thus allowing to get a more “objective” representation of the response to flicker. The system used to both generate flicker and measure the pupil diameter has been illustrated along with all the results of several experiments performed on the volunteers. The intent has been to demonstrate that the measurement of that geometrical parameter can give reliable information about the feeling of the human visual system to light flicker.
Resumo:
In 1998 a pilot experiment was carried out to study the helicity dependence of photoreaction cross sections using circularly polarized real photons on longitudinally polarized deuterons in a deuterated butanol target. The knowledge of these cross sections is required to test the validity of the Gerasimov-Drell-Hearn sum rule on the deuteron and the neutron. The focus of this thesis is on the results for the differential and total cross sections for the photodisintegration reaction for various photon energies in the range from 200 to 450 MeV using data taken with the detector system DAPHNE. The current understanding of the NN interaction as represented by the calculations by M. Schwamb could be confirmed within the given uncertainties. In addition, the detector DAPHNE has been prepared for the main experiment in 2003. The according work is presented together with results of the quality-test measurements of the renewed detector components.
Resumo:
The present dissertation focuses on the measurement of nonmethane organic carbon compounds (NMOC) and their exchange by biosphere-atmosphere interactions. To access the accuracy, precision, and reproducibility of NMOC analysis, two intercomparison experiments were carried out during the present study. These experiments comprised the sampling of NMOCs on graphitised carbon blacks, followed by gas-chromatographic analysis. Furthermore, they comprised the sampling of short chain carbonyl compounds on solid phase extraction cartridges and their analysis by high pressure liquid chromatography. To investigate the exchange of NMOCs between vegetation and the atmosphere, plant enclosure studies were performed on two European deciduous tree species. These measurements were conducted during two consecutive summer seasons by utilisation of the above specified techniques on sunlit and shaded leaves of European beech (Fagus sylvatica L., monoterpene emitter) and sunlit leaves of English oak (Quercus robur L., isoprene emitter). According to its broad geographical distribution, the impact of European beech on the European monoterpene budget was characterized by a model simulation. Complementary an instrument was developed, that is capable of measuring the amount of total NMOC that is exchanged by biosphere-atmosphere interactions. The instrument was tested under laboratory conditions and was evaluated versus an independent method performing branch enclosure measurements.