877 resultados para prosthetic fit


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Odontologia - FOA

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this systematic review was to evaluate clinical studies on the follow-up survival of implants inserted in the zygomatic bone for maxillary rehabilitation. A comprehensive search of studies published from 2000 to July 2012 and listed in the PubMed/MEDLINE, Embase, and Cochrane Library databases was performed in accordance with the PRISMA statement. Relevant studies were selected according to predetermined inclusion and exclusion criteria. The initial database search yielded 751 titles. After filtering, 313 abstracts were selected, culminating in 42 full text articles. Application of eligibility criteria led to the elimination of 17 articles. Hence 25 full-text articles were considered clinically relevant and were included. Calculations of the interval survival rates and cumulative survival rates of implants could be carried out on the data extracted from the final list of included studies for the different time intervals. These studies reported the insertion of a total of 1541 zygomatic implants and 33 implant failures. Failure generally occurred during the first year interval and was related to clinical complications, such as recurrent acute and chronic sinusitis. After a 36-month follow-up, the survival rate was 97.86%. Additional studies with longer follow-up periods, including the number of zygomatic implants inserted and details of the variations in the surgical techniques used and the impact of the maxillary morphology are still required.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Statement of problem. An imprecise fit between frameworks and supporting dental implants in loaded protocols increases the strain transferred to the periimplant bone, which may impair healing or generate microgaps.Purpose. The purpose of this study was to investigate the microstrain between premachined 1-piece screw-retained frameworks (group STF) and screw-retained frameworks fabricated by cementing titanium cylinders to the prefabricated framework (group CTF). This procedure was developed to correct the misfit between frameworks and loaded implants.Material and methods. Four internal hexagon cylindrical implants were placed 10 mm apart in a polyurethane block by using the surgical guides of the corresponding implant system. Previously fabricated titanium frameworks (n=10) were divided into 2 groups. In group STF, prefabricated machined frameworks were used (n=5), and, in group CTF, the frameworks were fabricated by using a passive fit procedure, which was developed to correct the misfit between the cast titanium frameworks and supporting dental implants (n=5). Both groups were screw-retained under torque control (10 Ncm). Six strain gauges were placed on the upper surface of the polyurethane block, and 3 strain measurements were recorded for each framework. Data were analyzed with the Student t test (alpha=.05).Results. The mean microstrain values between the framework and the implants were significantly higher for group STF (2517 me) than for group CTF (844 me) (P<.05).Conclusions. Complete-arch implant frameworks designed for load application and fabricated by using the passive fit procedure decreased the strain between the frameworks and implants more than 1 piece prefabricated machined frameworks.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

When dental implants are malpositioned in relation to the adjacent teeth and alveolar bone or in an excessive buccal or lingual position, the final prosthesis rehabilitation impairs the peri-implant health of the gingival tissues and the aesthetics of the patient. Thus, the purpose of this case was to report and discuss a multidisciplinary protocol for the treatment of a compromised maxillary tooth in a patient with an abscess in his right central incisor due to an excessive buccal implant position. The patient presented with an implant-supported provisional restoration on his right maxillary central incisor and a traumatic injury in his left central incisor. The treatment protocol consisted in (i) abutment substitution to compensate the incorrect angulation of the implant, (ii) clinical crown lengthening, (iii) atraumatic extraction of the left central incisor, and (iv) immediate implant placement. Finally, (v) a custom abutment was fabricated to obtain a harmonious gingival contour around the prosthetic crown. In conclusion, when implants are incorrectly positioned in relation to the adjacent teeth, associated with soft-tissue defects, the challenge to create a harmonious mucogingival contours may be achieved with an interdisciplinary approach and with the placement of an appropriate custom abutment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study investigated the biomechanical behavior of screwed partial fixed prosthesis supported by implants with different diameters (2.5 mm; 3.3 mm and 3.75 mm) by using a photoelastic analysis. Six photoelastic models were fabricated in PL-2 resin as single crowns or splinted 3-unit piece. Models were positioned in a circular polariscope and 100-N axial and oblique (45 degrees) loads were applied in the occlusal surface of the crowns by using a universal testing machine (EMIC). The stresses were photographically recorded and qualitatively analyzed using a software (Adobe Photoshop). Under axial loading, the number of fringes was inversely proportional to the diameter of the implants in the single crown models. In the splinted 3-unit piece, the 3.75-mm implant promoted lower number of fringes regardless of loading area application. Under oblique loading, a slight increase of fringes number was observed for all groups. The standard implant diameter promoted better stress distribution than the narrow and mini diameter implants. Additionally, the splinted crowns showed a more uniform stress distribution.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The gastroesophageal reflux disease (GERD) is one of the main causes of dental erosion. The aim of this case presented is to describe the prosthetic rehabilitation of a patient with GERD after 4 years of followup. A 33-year-old male patient complained about tooth sensitivity. The lingual surface of the maxillary anterior teeth and the cusps of the upper and lower posterior teeth presented wear. It was suspected that the feeling of heartburn reported by the patient associated with the intake of sports supplements (isotonics) was causing gastroesophageal changes. The patient was referred to a gastroenterologist and was diagnosed with GERD. Dental treatment was performed with metal-free crowns and porcelain veneers after medical treatment of the disease. With the change in eating habits, the treatment of GERD and lithium disilicate ceramics provided excellent cosmetic results after 4 years and the patient reported satisfaction with the treatment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The treatment of orofacial tumors may cause facial deformities by losses of structures that affect basic functions, i.e. feeding, speech, and the reduction of patient self-steam. A white male patient was diagnosed with epidermoid cancer on the mandibular alveolar ridge with infiltration staging IV A. The patient was submitted to a mandibulectomy associated with a complete extraction of mandibular teeth. For rehabilitation, a conventional denture for the mandibular arch and a removable partial denture for the maxillary arch were fabricated. A correct occlusal adjustment and a satisfactory amount of alveolar bone was favorable for conventional dentures of the prostheses bases improve their retention and stability. After one year of follow-up, the patient was adapted to the prostheses, satisfied with their retention, and reported an improvement on his feeding. The prosthetic rehabilitation of patients after a partial mandibulectomy is essential for their self-steam. Conventional dentures may have their retention and stability improved if they are well fabricated, recorded and have a balanced occlusion. A correct occlusal adjustment and an adequate retention of the prostheses bases may improve their retention and stability. Patients without xerostomy and with a satisfactory amount of alveolar bone may have a favorable prognosis for conventional dentures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Theories proposed by Chickering, Astin, Helms, Gilligan, and Perry serve as a framework for under¬standing and explaining the development of college students.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: The aim of this study was to investigate the internal fit (IF) of glass-infiltrated alumina (ICA - In-Ceram Alumina), yttria-stabilized tetragonal zirconia polycrystals (Y-TZP - IPS e.max ZirCAD), and metal-ceramic (MC - Ni-Cr alloy) crowns. Material and Methods: Sixty standardized resin-tooth replicas of a maxillary first molar were produced for crown placement and divided into 3 groups (n=20 each) according to the core material used (metal, ICA or Y-TZP). The IF of the crowns was measured using the replica technique, which employs a light body polyvinyl siloxane impression material to simulate the cement layer thickness. The data were analyzed according to the surfaces obtained for the occlusal space (OS), axial space (AS) and total mean (TM) using two-way ANOVA with Tukey's multiple comparison test (p<0.05). Results: No differences among the different areas were detected in the MC group. For the Y-TZP and ICA groups, AS was statistically lower than both OS and TM. No differences in AS were observed among the groups. However, OS and TM showed significantly higher values for ICA and Y-TZP groups than MC group. Comparisons of ICA and Y-TZP revealed that OS was significantly lower for Y-TZP group, whereas no differences were observed for TM. Conclusions: The total mean achieved by all groups was within the range of clinical acceptability. However, the metal-ceramic group demonstrated significantly lower values than the all-ceramic groups, especially in OS.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: The aim of this study was to evaluate the variation in removal torque of implant prosthetic abutment screws after successive tightening and loosening cycles, in addition to evaluating the influence of the hexagon at the abutment base on screw removal torque. Material and methods: Twenty hexagonal abutments were tightened to 20 regular external hex implants with a titanium alloy screw, with an insertion torque of 32 N cm, measured with a digital torque gauge. The implant/abutment/screw assemblies were divided into two groups: ( 1) abutments without hexagon at the base and ( 2) abutments with a hexagon at the base. Each assembly received a provisional restoration and was submitted to mechanical loading cycles. After this, the screws were removed and the removal torque was measured. This sequence was repeated 10 times, then the screw was replaced by a new one, and another cycle was performed. Linear regression analysis was performed. Results: Removal torque values tended to decrease as the number of insertion/removal cycles increased, for both groups. Comparisons of the slopes and the intercepts between groups showed no statistical difference. There was no significant difference between the mean values of last five cycles and the 11th cycle. Within the limitations of this in vitro study, it was concluded that ( 1) repeated insertion/removal cycles promoted gradual reduction in removal torque of screws, ( 2) replacing the screw with a new one after 10 cycles did not increase resistance to loosening, and ( 3) removal of the hexagon from the abutment base had no effect on the removal torque of the screws.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bertuzzi, R, Franchini, E, Tricoli, V, Lima-Silva, AE, Pires, FDO, Okuno, NM, and Kiss, MAPDM. Fit-climbing test: A field test for indoor rock climbing. J Strength Cond Res 26(6): 1558-1563, 2012-The aim of this study was to develop an indoor rock-climbing test on an artificial wall (Fit-climbing test). Thirteen climbers (elite group [EG] = 6; recreational group [RG] = 7) performed the following tests: (a) familiarization in the Fitclimbing test, (b) the Fit-climbing test, and (c) a retest to evaluate the Fit-climbing test's reliability. Gas exchange, blood lactate concentration, handgrip strength, and heart rate were measured during the test. Oxygen uptake during the Fit-climbing test was not different between groups (EG = 8.4 +/- 1.1 L; RG = 7.9 +/- 1.5 L, p > 0.05). The EG performance (120 +/- 7 movements) was statistically higher than the RG climbers' performance (78 +/- 13 movements) during the Fit-climbing test. Consequently, the oxygen cost per movement during the Fit-climbing test of the EG was significantly lower than that of the RG (p < 0.05). Handgrip strength was higher in the EG when compared with that in the RG in both pre-Fit- and post-Fit-climbing test (p < 0.05). There were no significant differences in any other variables analyzed during the Fit-climbing test (p > 0.05). Furthermore, the performance in the Fit-climbing test presented high reliability (intraclass correlation coefficient = 0.97). Therefore, the performance during the Fit-climbing test may be an alternative to evaluate rock climbers because of its specificity and relation to oxygen cost per movement during climbing.