951 resultados para phage display antibody
Resumo:
The most practicable assay for measurement of measles IgG (mIgG) in large numbers of sera is an enzyme immunoassay (EIA). To assess how EIA results would agree with those by the gold standard method of plaque reduction neutralization (PRN) we compared the results from the two methods in 43 pairs of maternal and umbilical cord sera, and sera from the corresponding infants when aged 11 - 14 months. In maternal-cord sera, the differences between mean antibody levels by EIA or PRN were not statistically significant, though in individual sera, differences could be large. However, agreement was less good for infants sera, in which levels of mIgG were very low. The conclusions of a study of transplacental transport of mIgG would not be affected by the use of either technique. When studying waning immunity in infants, PRN should be the method of choice, while results from studies using EIA should be interpreted with caution.
Resumo:
Toxocariasis is caused by infection of man by Toxocara canis and Toxocara cati larvae, the common roundworm of dogs and cats. Because larvae are difficult to detect in tissues, diagnosis is mostly based on serology. Non specific reactions are observed mainly due to cross-reactivity with Ascaris sp antigens. This investigation aimed at developing and evaluating an indirect antibody competition ELISA (IACE) employing a specific rabbit IgG anti-Toxocara canis excretory-secretory antigens as the competition antibody, in order to improve indirect ELISA specificity performed for toxocariasis diagnosis. For that, the rabbit IgG was previously absorbed by Ascaris suum adult antigens. Sensitivity and specificity of IACE were first evaluated in 28 serum samples of mice experimentally infected with T. canis embryonated eggs. Adopting cut-off value established in this population before infection, sensitivity and specificity were 100% after 20 days post-inoculation. For human population IACE was evaluated using sera from 440 patients with clinical signs of toxocariasis and the cut-off value was established with 60 serum samples from apparently healthy individuals. Using as reference test the indirect ELISA performed by Adolfo Lutz Institute, sensitivity was 60.2%, specificity was 98% and concordance was 77.3%. Repeatability of IACE was evaluated by the inter-reactions variation coefficient (2.4%).
Resumo:
We report the detection of specific IgA antibodies and the determination of IgG avidity in sequential serum samples from a patient exhibiting significant levels of Toxoplasma-specific IgM antibodies for seven years after the onset of the clinical symptoms of toxoplasmosis. IgM antibodies were detected by an indirect immunofluorescence test and by three commercial enzyme-linked immunosorbent assays (ELISA). Anti-T. gondii IgA was quantified by the a-capture ELISA technique using a commercial kit. As defined by the manufacturer of the IgA ELISA test used, most patients with acute toxoplasmosis have antibody levels > 40 arbitrary units per ml (AU/mL). At this cut-off level, the patient still had a positive ELISA result (45 AU/mL) in a serum sample taken one year after the beginning of clinical manifestations. The IgG avidity-ELISA test was performed with the Falcon assay screening test (F.A.S.T.®) - ELISA system. Avidity indices compatible with a recent Toxoplasma infection were found only in serum samples taken during the first 5 months after the onset of the clinical symptoms of toxoplasmosis. These results show that the interpretation of positive IgM results as indicative of recently acquired toxoplasmosis requires additional laboratory confirmation either by other tests or by the demonstration of a significant rise in the antibody titers in sequential serum samples.
Resumo:
Active infection by T. gondii was evaluated by immunoassay for soluble SAG-1 (p30), the major surface antigen from T. gondii, specific antibodies and immune complexes in human cerebrospinal fluid (CSF) samples. A total of 263 samples of CSF were collected from hospitalized patients presenting neurological disorders and analyzed for antibodies to HIV. Patients were divided into two groups: HIV positive (n = 96) or HIV negative (n =167). The results of the assays showed that 45% of all samples were positive for soluble SAG-1. Toxoplasma Ag/Ab immune complexes were detected in 19% of the CSF samples and 62% were positive for T. gondii- specific IgG. A combination of these assays in the presence of clinical findings consistent with active Toxoplasma infection may predict the presence of toxoplasmic encephalitis. Moreover, detection of soluble SAG-1 in the CSF of these individuals appears consistent with active infection.
Resumo:
Despite the absence of current official reports showing the number of cattle infected by rabies, it is estimated that nearly 30,000 bovines are lost each year in Brazil. In order to minimize the important economic losses, control of the disease is achieved by eliminating bat colonies and by herd vaccination. In this study, we compare the antibody response in cattle elicited by vaccination with an attenuated ERA vaccine (AEvac) and an inactivated-adjuvanted PV (IPVvac) vaccine. The antibody titers were appraised by cell-culture neutralization test and ELISA, and the percentage of seropositivity was ascertained for a period of 180 days. IPVvac elicited complete seropositivity rates from day 30 to day 150, and even on day 180, 87% of the sera showed virus-neutralizing antibody titers (VNA) higher than 0.5IU/ml. There were no significant differences between the VNA titers and seropositivity rates obtained with IPVvac in the two methods tested. AEvac, however, elicited significantly lower titers than those observed in the group receiving inactivated vaccine. In addition, the profiles of antirabies IgG antibodies, evaluated by ELISA, and VNA, appraised by cell-culture neutralization test, were slightly different, when both vaccines were compared.
Resumo:
The clinical significance of isolated anti-HBc is still a challenge. To elucidate the real importance of this finding in our blood donors, an investigation algorithm was tested. One hundred and twelve isolated anti-HBc seropositive blood donors underwent clinical evaluation and retesting of HBV markers. Those who presented repeatedly reactive isolated anti-HBc, received a single dose of hepatitis B recombinant vaccine to verify anti-HBs early response. A HBV-DNA determination by PCR was done for those who did not test positive to anti-HBs after vaccine. The level of anti-HBc was recorded as a ratio of the sample-to-cut-off values (S:C ratio) in 57 candidates at donation. Comparing true and false-positive anti-HBc results, the different S:C ratios of them were statistically significant and when less than 2, implying in a false-positive result probability over 80%. A high percent of false-positive results (16.07%) was verified after anti-HBc retesting. HBV immunity was characterized in 49.11%, either by anti-HBs detection in retesting (15.18%), or after a single dose HBV vaccination (33.93%). HBV-DNA was negative in all tested donors. In conclusion, this algorithm was useful to clarify the meaning of isolated anti-HBc in most of our blood donors.
Resumo:
A prospective study was designed to evaluate disorders of hemostasis and levels of anticardiolipin antibodies (ACL) in 30 patients with severe leptospirosis and acute renal failure (ARF) (ARF was defined as serum creatinine > or = 1.5 mg/dL). The patients had been admitted to the Walter Cantídio University Hospital, São José Infectious Diseases Hospital and General Hospital of Fortaleza, Ceará, from August 1999 to July 2001. They all were male, with a mean age of 32 ± 14 years and with clinical and laboratory diagnoses of ARF leptospirosis. The time elapsed between onset of symptoms and the first hemorrhagic manifestation was 9 ± 4 days. Bleeding was observed in 86% of the patients. Laboratory tests showed significantly high levels of urea (181 ±95 mg/dl), fibrinogen, (515 ± 220 mg/dl), prothrombin time (13.3 ± 0.9 seconds) and low platelet counts (69 ± 65x10³/mm³) on admission. There was no elevation in activated partial thromboplastin time or thrombin time. Levels of IgM and IgG ACL concentrations were significantly increased (p < 0.05) in leptospirosis patients when compared to control patients (28.5 ± 32.4 vs. 11.5 ± 7.9MPL U/ml and 36.7 ± 36.1 vs. 6.5 ± 2.5 GPL U/ml), respectively. Vasculitis, thrombocytopenia and uremia should be considered important factors for the pathogenesis of hemorrhagic disturbances and the main cause of death in severe leptospirosis.
Resumo:
Thesis for the Master degree in Structural and Functional Biochemistry
Resumo:
272 isolates of Salmonella Enteritidis (111 isolated from frozen broiler chicken carcasses, 126 from human food and other biological materials involved in food poisoning outbreaks and 35 from different poultry materials) were selected for phage typing. From these, 111 were phage typed, 57.65% being classified as phage type 4, 32.43% as phage type 4a, 3.60% as phage type 6a and 0.90% as phage type 7, whereas 5.40% samples were not phage typeable. The predominance of phage type 4 is in agreement with the results published worldwide, and reinforces the need for studies related to the epidemiological meaning of these findings.
Resumo:
This work shows that the synthesis of protein plastic antibodies tailored with selected charged monomersaround the binding site enhances protein binding. These charged receptor sites are placed over a neutralpolymeric matrix, thus inducing a suitable orientation the protein reception to its site. This is confirmed bypreparing control materials with neutral monomers and also with non-imprinted template. This concepthas been applied here to Prostate Specific Antigen (PSA), the protein of choice for screening prostate can-cer throughout the population, with serum levels >10 ng/mL pointing out a high probability of associatedcancer.Protein Imprinted Materials with charged binding sites (C/PIM) have been produced by surfaceimprinting over graphene layers to which the protein was first covalently attached. Vinylben-zyl(trimethylammonium chloride) and vinyl benzoate were introduced as charged monomers labellingthe binding site and were allowed to self-organize around the protein. The subsequent polymerizationwas made by radical polymerization of vinylbenzene. Neutral PIM (N/PIM) prepared without orientedcharges and non imprinted materials (NIM) obtained without template were used as controls.These materials were used to develop simple and inexpensive potentiometric sensor for PSA. Theywere included as ionophores in plasticized PVC membranes, and tested over electrodes of solid or liq-uid conductive contacts, made of conductive carbon over a syringe or of inner reference solution overmicropipette tips. The electrodes with charged monomers showed a more stable and sensitive response,with an average slope of -44.2 mV/decade and a detection limit of 5.8 × 10−11mol/L (2 ng/mL). The cor-responding non-imprinted sensors showed lower sensitivity, with average slopes of -24.8 mV/decade.The best sensors were successfully applied to the analysis of serum, with recoveries ranging from 96.9to 106.1% and relative errors of 6.8%.
Resumo:
This work proposes a novel approach for a suitable orientation of antibodies (Ab) on an immunosensing platform, applied here to the determination of 8-hydroxy-2′-deoxyguanosine (8OHdG), a biomarker of oxidative stress that has been associated to chronic diseases, such as cancer. The anti-8OHdG was bound to an amine modified gold support through its Fc region after activation of its carboxylic functions. Non-oriented approaches of Ab binding to the platform were tested in parallel, in order to show that the presented methodology favored Ab/Ag affinity and immunodetection of the antigen. The immunosensor design was evaluated by quartz-crystal microbalance with dissipation, atomic force microscopy, electrochemical impedance spectroscopy (EIS) and square-wave voltammetry. EIS was also a suitable technique to follow the analytical behavior of the device against 8OHdG. The affinity binding between 8OHdG and the antibody immobilized in the gold modified platform increased the charge transfer resistance across the electrochemical set-up. The observed behavior was linear from 0.02 to 7.0 ng/mL of 8OHdG concentrations. The interference from glucose, urea and creatinine was found negligible. An attempt of application to synthetic samples was also successfully conducted. Overall, the presented approach enabled the production of suitably oriented Abs over a gold platform by means of a much simpler process than other oriented-Ab binding approaches described in the literature, as far as we know, and was successful in terms of analytical features and sample application.
Resumo:
This work uses surface imprinting to design a novel smart plastic antibodymaterial (SPAM) for Haemoglobin (Hb). Charged binding sites are described here for the first time to tailor plastic antibody nanostructures for a large size protein such as Hb. Its application to design small, portable and low cost potentiometric devices is presented. The SPAM material was obtained by linking Hb to silica nanoparticles and allowing its ionic interaction with charged vinyl monomers. A neutral polymeric matrix was created around these and the imprinted protein removed. Additional materials were designed in parallel acting as a control: a neutral imprinted material (NSPAM), obtained by removing the charged monomers from the procedure, and the Non-Imprinted (NI) versions of SPAM and NSPAM by removing the template. SEM analysis confirmed the surface modification of the silica nanoparticles. All materials were mixed with PVC/plasticizer and applied as selective membranes in potentiometric transduction. Electromotive force (emf) variations were detected only for selective membranes having a lipophilic anionic additive in the membrane. The presence of Hb inside these membranes was evident and confirmed by FTIR, optical microscopy and Raman spectroscopy. The best performance was found for SPAM-based selective membranes with an anionic lipophilic additive, at pH 5. The limits of detection were 43.8 mg mL 1 and linear responses were obtained down to 83.8 mg mL 1, with an average cationic slope of +40 mV per decade. Good selectivity was also observed against other coexisting biomolecules. The analytical application was conducted successfully, showing accurate and precise results.
Resumo:
This work proposes a novel approach for a suitable orientation of antibodies (Ab) on an immunosensing platform, applied here to the determination of 8-hydroxy-2’-deoxyguanosine (8OHdG), a biomarker of oxidative stress that has been associated to chronic diseases, such as cancer. The Anti-8OHdG was bound to an amine modified gold support through its Fc region after activation of its carboxylic functions. Non-oriented approaches of Ab binding to the platform were tested in parallel, in order to show that the presented proposal favored Ab/Ag affinity. The immunosensor design was evaluated by Quartz-Crystal microbalance with Dissipation, Atomic Force Microscopy, Electrochemical Impedance Spectroscopy (EIS) and Square-Wave Voltammetry. EIS was also a suitable technique to follow the analytical behavior of the device against 8OHdG. The affinity binding between 8OHdG and the antibody immobilized in the gold modified platform increased the charged transfer resistance across the electrochemical sep-up. The observed behavior was linear from 0.02 to 7.0 ng/mL of 8OHdG concentrations. The interference from Glucose, Urea and Creatinine was found negligible. An attempt of application to synthetic samples was also successfully conducted. Overall, the presented approach enabled the production of suitably oriented Abs over a gold platform by means of a much simpler process than other oriented-Ab binding approaches described in the literature, as far as we know, and was successful in terms of analytical features and sample application.
Resumo:
A backside protein-surface imprinting process is presented herein as a novel way to generate specific synthetic antibody materials. The template is covalently bonded to a carboxylated-PVC supporting film previously cast on gold, let to interact with charged monomers and surrounded next by another thick polymer. This polymer is then covalently attached to a transducing element and the backside of this structure (supporting film plus template) is removed as a regular “tape”. The new sensing layer is exposed after the full template removal, showing a high density of re-binding positions, as evidenced by SEM. To ensure that the templates have been efficiently removed, this re-binding layer was cleaned further with a proteolytic enzyme and solution washout. The final material was named MAPS, as in the back-side reading of SPAM, because it acts as a back-side imprinting of this recent approach. It was able to generate, for the first time, a specific response to a complex biomolecule from a synthetic material. Non-imprinted materials (NIMs) were also produced as blank and were used as a control of the imprinting process. All chemical modifications were followed by electrochemical techniques. This was done on a supporting film and transducing element of both MAPS and NIM. Only the MAPS-based device responded to oxLDL and the sensing layer was insensitive to other serum proteins, such as myoglobin and haemoglobin. Linear behaviour between log(C, μg mL−1) versus charged tranfer resistance (RCT, Ω) was observed by electrochemical impedance spectroscopy (EIS). Calibrations made in Fetal Calf Serum (FCS) were linear from 2.5 to 12.5 μg mL−1 (RCT = 946.12 × log C + 1590.7) with an R-squared of 0.9966. Overall, these were promising results towards the design of materials acting close to the natural antibodies and applied to practical use of clinical interest.
Resumo:
This work introduces two major changes to the conventional protocol for designing plastic antibodies: (i) the imprinted sites were created with charged monomers while the surrounding environment was tailored using neutral material; and (ii) the protein was removed from its imprinted site by means of a protease, aiming at preserving the polymeric network of the plastic antibody. To our knowledge, these approaches were never presented before and the resulting material was named here as smart plastic antibody material (SPAM). As proof of concept, SPAM was tailored on top of disposable gold-screen printed electrodes (Au-SPE), following a bottom-up approach, for targeting myoglobin (Myo) in a point-of-care context. The existence of imprinted sites was checked by comparing a SPAM modified surface to a negative control, consisting of similar material where the template was omitted from the procedure and called non-imprinted materials (NIMs). All stages of the creation of the SPAM and NIM on the Au layer were followed by both electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV). AFM imaging was also performed to characterize the topography of the surface. There are two major reasons supporting the fact that plastic antibodies were effectively designed by the above approach: (i) they were visualized for the first time by AFM, being present only in the SPAM network; and (ii) only the SPAM material was able to rebind to the target protein and produce a linear electrical response against EIS and square wave voltammetry (SWV) assays, with NIMs showing a similar-to-random behavior. The SPAM/Au-SPE devices displayed linear responses to Myo in EIS and SWV assays down to 3.5 μg/mL and 0.58 μg/mL, respectively, with detection limits of 1.5 and 0.28 μg/mL. SPAM materials also showed negligible interference from troponin T (TnT), bovine serum albumin (BSA) and urea under SWV assays, showing promising results for point-of-care applications when applied to spiked biological fluids.