959 resultados para lithic artifacts
Resumo:
In proton magnetic resonance imaging (MRI) metallic substances lead to magnetic field distortions that often result in signal voids in the adjacent anatomic structures. Thus, metallic objects and superparamagnetic iron oxide (SPIO)-labeled cells appear as hypointense artifacts that obscure the underlying anatomy. The ability to illuminate these structures with positive contrast would enhance noninvasive MR tracking of cellular therapeutics. Therefore, an MRI methodology that selectively highlights areas of metallic objects has been developed. Inversion-recovery with ON-resonant water suppression (IRON) employs inversion of the magnetization in conjunction with a spectrally-selective on-resonant saturation prepulse. If imaging is performed after these prepulses, positive signal is obtained from off-resonant protons in close proximity to the metallic objects. The first successful use of IRON to produce positive contrast in areas of metallic spheres and SPIO-labeled stem cells in vitro and in vivo is presented.
Resumo:
The aim was to propose a strategy for finding reasonable compromises between image noise and dose as a function of patient weight. Weighted CT dose index (CTDI(w)) was measured on a multidetector-row CT unit using CTDI test objects of 16, 24 and 32 cm in diameter at 80, 100, 120 and 140 kV. These test objects were then scanned in helical mode using a wide range of tube currents and voltages with a reconstructed slice thickness of 5 mm. For each set of acquisition parameter image noise was measured and the Rose model observer was used to test two strategies for proposing a reasonable compromise between dose and low-contrast detection performance: (1) the use of a unique noise level for all test object diameters, and (2) the use of a unique dose efficacy level defined as the noise reduction per unit dose. Published data were used to define four weight classes and an acquisition protocol was proposed for each class. The protocols have been applied in clinical routine for more than one year. CTDI(vol) values of 6.7, 9.4, 15.9 and 24.5 mGy were proposed for the following weight classes: 2.5-5, 5-15, 15-30 and 30-50 kg with image noise levels in the range of 10-15 HU. The proposed method allows patient dose and image noise to be controlled in such a way that dose reduction does not impair the detection of low-contrast lesions. The proposed values correspond to high- quality images and can be reduced if only high-contrast organs are assessed.
Resumo:
RecA protein in bacteria and its eukaryotic homolog Rad51 protein are responsible for initiation of strand exchange between homologous DNA molecules. This process is crucial for homologous recombination, the repair of certain types of DNA damage and for the reinitiation of DNA replication on collapsed replication forks. We show here, using two different types of in vitro assays, that in the absence of ATP hydrolysis RecA-mediated strand exchange traverses small substitutional heterologies between the interacting DNAs, whereas small deletions or insertions block the ongoing strand exchange. We discuss evolutionary implications of RecA selectivity against insertions and deletions and propose a molecular mechanism by which RecA can exert this selectivity.
Resumo:
Bacteria are generally difficult specimens to prepare for conventional resin section electron microscopy and mycobacteria, with their thick and complex cell envelope layers being especially prone to artefacts. Here we made a systematic comparison of different methods for preparing Mycobacterium smegmatis for thin section electron microscopy analysis. These methods were: (1) conventional preparation by fixatives and epoxy resins at ambient temperature. (2) Tokuyasu cryo-section of chemically fixed bacteria. (3) rapid freezing followed by freeze substitution and embedding in epoxy resin at room temperature or (4) combined with Lowicryl HM20 embedding and ultraviolet (UV) polymerization at low temperature and (5) CEMOVIS, or cryo electron microscopy of vitreous sections. The best preservation of bacteria was obtained with the cryo electron microscopy of vitreous sections method, as expected, especially with respect to the preservation of the cell envelope and lipid bodies. By comparison with cryo electron microscopy of vitreous sections both the conventional and Tokuyasu methods produced different, undesirable artefacts. The two different types of freeze-substitution protocols showed variable preservation of the cell envelope but gave acceptable preservation of the cytoplasm, but not lipid bodies, and bacterial DNA. In conclusion although cryo electron microscopy of vitreous sections must be considered the 'gold standard' among sectioning methods for electron microscopy, because it avoids solvents and stains, the use of optimally prepared freeze substitution also offers some advantages for ultrastructural analysis of bacteria.
Resumo:
Apresentam‑se os principais resultados obtidos nas duas missões arqueológicas patrocinadas pelo Centro Português de Actividades Subaquáticas (CPAS) à ilha de São Vicente (República de Cabo Verde), em 1998 e em 2005. Em 1998, confirmou‑se o efectivo interesse arqueológico do sítio, localizado sobre o mar, em local abrigado da vasta baía de Salamansa, situada na parte setentrional da ilha, tendo‑se registado a respectiva extensão e estratigrafia e procedido à colheita de amostras para datação. Embora os resultados dessa campanha tivessem sido publicados, indicando estação de carácter habitacional, revelada pela notável acumulação de conchas, acompanhada de abundantes fragmentos de cerâmicas manuais, de produção africana, mantinha‑se indefinida a sua verdadeira natureza. Impunha‑se, assim, proceder à escavação integral da área que ainda subsistia da estação — sujeita de forma contínua a forte erosão marinha — bem como à colheita de novos materiais para datação, de forma a confirmar as conclusões preliminares anteriormente obtidas, objectivos que se concretizaram em 2005. Deste modo, foi possível concluir que, contrariando a hipótese, de início considerada, de poder corresponder a um testemunho da ocupação da ilha em época anterior à chegada dos Portugueses — hipótese que já as primeiras datas de radiocarbono contradiziam — se trata de um sítio onde uma unidade habitacional construída por muros de pedra seca, de planta ortogonal, revela inspiração europeia, aliás sublinhada pelos materiais exumados, onde estão representados produtos com tal origem, como cachimbos de caulino, vidros, faianças portuguesas, e projécteis de armas de fogo, a par de objectos oriundos do Extremo Oriente, num quadro dominado pelas produções cerâmicas africanas. Esta situação evidencia um estabelecimento cuja ocupação se centrou no século XVII, conforme indicam os materiais recolhidos e os resultados das datações obtidas, francamente aberto aos contactos de longa distância, apesar do isolamento do local escolhido. Os restos faunísticos recolhidos, com a presença deburro e de boi, sugerem um estacionamento sedentário, sendo a alimentação assegurada essencialmente pela captura de tartarugas, pela pesca e pela recolecção de moluscos marinhos (especialmente grandes lapas) e complementada pelo consumo de cabra, que poderia ser doméstica ou caçada, dado o estado selvagem a que retornou ali esta espécie. na última parte do trabalho, discutem‑se as diversas hipóteses susceptíveis de explicar esta estação — desde um entreposto comercial relacionado com a exploração agro‑pecuária da ilha de Santo Antão, passando por pequeno estabelecimento especializado de apoio à navegação, com a produção de carne salgada de tartaruga, até ter constituído refúgio relacionado com a intensa pirataria vigente à época no arquipélago, tendo presente os elementos históricos conhecidos, que, aliás, indicam que o início da ocupação permanente de São Vicente só se produziu a partir da segunda década do século XIX. Seja como for, a forte componente cultural africana revelada pelo espólio destes primeiros ocupantes da ilha expressa‑se também pelos rituais que terão envolvido o abandono do estabelecimento, com o enterramento de dois vasos emborcados sob o chão da habitação explorada, e a deposição de uma pequena taça, nas mesmas circunstâncias, junto à parede da mesma, do lado externo.
Resumo:
Team Archaeology is excited to be riding with you this year! We hope to make our participation an annual opportunity to share the story of Iowa’s amazing past. As you ride across the state you will be passing by the locations of hundreds of known archaeological sites and an as yet unknown number of new discoveries waiting to be made. These archaeological sites, and the artifacts they contain, tell the history of the first people to travel this landscape and the stories of each generation that has contributed to what we know of ourselves today. As you travel through our beautiful state, you too are now a part of that story, making history for the future to learn and wonder about! The Office of the State Archaeologist serves a unique dual role in Iowa as both a designated research unit of The University of Iowa and as a state agency. The larger mission of the OSA is to develop, disseminate, and preserve knowledge of Iowa’s human past through Midwestern and Plains archaeological research, scientific discovery, public stewardship, service, and education. It is our goal to provide all Iowans the opportunity to learn about their past. I see this as an investment in the preservation of a nonrenewable resource—the archaeological record of Iowa. Look for the Team Archeology members as you ride and be sure to ask them about Iowa archeology. Please help yourself to free materials about our shared past from our information tables at each overnight town and get one of the free Iowa Archeology wrist bands. There will also be free public talks by local archaeologists each afternoon, as well as flintknapping and other demonstrations of archaeological interest, so keep this booklet as your guide to the week’s activities. Most of all, ride smart, be safe, and when you get home tell your friends and neighbors about Iowa archaeology!
Resumo:
In this work we present a first feasibility study of the ClearPEM technology for simultaneous PET-MR imaging. The mutual electromagnetic interference (EMI) effects between both systems were evaluated on a 7 T magnet by characterizing the response behavior of the ClearPEM detectors and front-end electronics to pulsed RF power and switched magnetic field gradients; and by analyzing the MR system performance degradation from noise pickup into the RF receiver chain, and from magnetic susceptibility artifacts caused by PET front-end materials.
Resumo:
PURPOSE: Recent work practices in the conservation and restoration involve the use of cyclododecane (CDD, CAS 294-62-2) to protect fragile artifacts during their handling or transportation. Little is known about its toxicity, and no previous exposure has been reported. A short field investigation was conducted to characterize the exposure conditions to both CDD vapors and aerosols.METHODS: Measurements were conducted in the laboratory of conservation and restoration of the archeological service in Bern (Switzerland). Three indoor and four outdoor typical work situations, either during brush or spray gun applications, were investigated. Measurements were performed on charcoal adsorbent tube and analyzed by a gas chromatograph equipped with a flame ionization detector.RESULTS: Measurements have been conducted during both brush and spray gun applications. Indoor exposures were of 0.75-15.5 mg/m(3), while outdoors exposures were 19.5-53.9 mg/m(3). Exposures appear to be extremely localized due to both physicochemical properties and application methods of the CDD. Vapor exposure increases dramatically with the confinement of the workplace.CONCLUSION: Preventive measures should be undertaken to limit as much as possible these exposures. Field work in confined areas (ditches, underground) is of particular concern. CDD-coated artifacts or materials should be stored in ventilated areas to avoid delayed exposures. [Authors]
Resumo:
At 3 T, the effective wavelength of the RF field is comparable to the dimension of the human body, resulting in B1 standing wave effects and extra variations in phase. This effect is accompanied by an increase in B0 field inhomogeneity compared to 1.5 T. This combination results in nonuniform magnetization preparation by the composite MLEV weighted T2 preparation (T2 Prep) sequence used for coronary magnetic resonance angiography (MRA). A new adiabatic refocusing T2 Prep sequence is presented in which the magnetization is tipped into the transverse plane with a hard RF pulse and refocused using a pair of adiabatic fast-passage RF pulses. The isochromats are subsequently returned to the longitudinal axis using a hard RF pulse. Numerical simulations predict an excellent suppression of artifacts originating from B1 inhomogeneity while achieving good contrast enhancement between coronary arteries and surrounding tissue. This was confirmed by an in vivo study, in which coronary MR angiograms were obtained without a T2 Prep, with an MLEV weighted T2 Prep and the proposed adiabatic T2 Prep. Improved quantitative and qualitative coronary MRA image measurement was achieved using the adiabatic T2 Prep at 3 T.
Resumo:
The objective of this study was to evaluate the prenatal detection of chromosomal abnormalities by fetal ultrasonographic examination in a large database provided by 19 Registries of Congenital Anomalies from 11 European countries. This study included 1738 cases of chromosomal abnormalities, liveborn, stillborn or termination of pregnancy regardless of maternal age from a population of 664,340 births during the period 1996 - 1998. The most frequent chromosomal anomalies were Down syndrome (n=1050), trisomy 18 (n=191), Turner syndrome (n=125), trisomy 13 (n=86), and triploidy (n=56). Fetal ultrasonographic examination resulted in the prenatal detection of 37.7% of the chromosomal abnormalities, thereby resulting in a reduction of 28.6% in their prevalence at birth due to terminations of pregnancy. The detection rate by ultrasound examination varied according to local policies of prenatal diagnosis : it was lower in countries where routine scan were not performed and higher in countries in which at least one routine anomaly scan during the second trimester of pregnancy was performed. The ultrasound detection varied according to the specific chromosomal anomaly and was lowest for Klinefelter syndrome (5.7%) and highest for triploidy (78.6%). For Down syndrome it was 26.4%. Termination of pregnancy was performed in 75.9% of the cases. Among the 655 cases detected by ultrasound, the most frequent ultrasound signs by category of chromosomal abnormalities were analysed. This study shows that ultrasound screening is an important tool in the prenatal detection of chromosomal abnormalities in Europe, leading to a significant reduction in the prevalence of livebirth children with chromosomal anomalies.
Resumo:
Among numerous magnetic resonance imaging (MRI) techniques, perfusion MRI provides insight into the passage of blood through the brain's vascular network non-invasively. Studying disease models and transgenic mice would intrinsically help understanding the underlying brain functions, cerebrovascular disease and brain disorders. This study evaluates the feasibility of performing continuous arterial spin labeling (CASL) on all cranial arteries for mapping murine cerebral blood flow at 9.4 T. We showed that with an active-detuned two-coil system, a labeling efficiency of 0.82 ± 0.03 was achieved with minimal magnetization transfer residuals in brain. The resulting cerebral blood flow of healthy mouse was 99 ± 26 mL/100g/min, in excellent agreement with other techniques. In conclusion, high magnetic fields deliver high sensitivity and allowing not only CASL but also other MR techniques, i.e. (1)H MRS and diffusion MRI etc, in studying murine brains.
Resumo:
BACKGROUND: Coronary in-stent restenosis cannot be directly assessed by magnetic resonance angiography (MRA) because of the local signal void of currently used stainless steel stents. The aim of this study was to investigate the potential of a new, dedicated, coronary MR imaging (MRI) stent for artifact-free, coronary MRA and in-stent lumen and vessel wall visualization. METHODS AND RESULTS: Fifteen prototype stents were deployed in coronary arteries of 15 healthy swine and investigated with a double-oblique, navigator-gated, free-breathing, T2-prepared, 3D cartesian gradient-echo sequence; a T2-prepared, 3D spiral gradient-echo sequence; and a T2-prepared, 3D steady-state, free-precession coronary MRA sequence. Furthermore, black-blood vessel wall imaging by a dual-inversion-recovery, turbo spin-echo sequence was performed. Artifacts of the stented vessel segment and signal intensities of the coronary vessel lumen inside and outside the stent were assessed. With all investigated sequences, the vessel lumen and wall could be visualized without artifacts, including the stented vessel segment. No signal intensity alterations inside the stent when compared with the vessel lumen outside the stent were found. CONCLUSIONS: The new, coronary MRI stent allows for completely artifact-free coronary MRA and vessel wall imaging.
Resumo:
In studying and forming an understanding of Iowa’s transportation history, we must surely develop a reverence for the lifestyles which preceded ours. Achieving a greater understanding of our past, we are better prepared to plan our future as we say farewell to the 20th century and move forward into the 21st. In the words of Oliver Wendell Holmes: “I believe the greatest thing in this world is not so much where we stand as in what direction we are moving... and the further backward you can look, the farther forward you can see.” To help Iowans gain a better understanding of our state’s rich transportation past, the Iowa Department of Transportation has produced a collection of materials including this booklet, the 1999-2000 Iowa Transportation Map, a video entitled A History of Iowa’s Rivers, Roads, Rails and Runways, and a traveling photo exhibit. In addition, Iowa is fortunate to have many local organizations, and the state-owned museum and historic sites, working to preserve the history of our state. Listed in the back section of this booklet are the addresses and descriptions of many sites that offer visitors an opportunity to see a wide range of transportation- related artifacts. The information and photographs are organized in time sequence. However, you will note that many of the transportation eras overlap. The booklet begins with Iowa’s pre-settlement era and concludes with the historic highway and transit program that was signed into law by President Clinton in 1998. As you can imagine, condensing this much Iowa history into a booklet-sized resource was a monumental challenge. Making selections and abbreviating the information resulted in some difficult editorial choices. However, we hope this publication will inspire readers to learn more about our rich, rewarding past and to visit and experience some of Iowa’s historic sites.
Resumo:
ABSTRACTPostmortem injuries are a source of misinterpretations in forensic analysis and therefore are subject matter of taphonomic interest. Many types of injuries can cause different artifacts, which deserve attention of the forensic pathologists when evaluating corpses, either at the crime scene or during an autopsy. Insects can be important biotaphonomic agents and their activity may result in artifacts that resemble antemortem injuries. Here, we describe postmortem injuries caused by the Neotropical wasp Agelaia fulvofasciata (Degeer, 1773) on domestic pig carcasses weighting 15 kg. The specimens showed extensive injuries to the lower lip, similar to lacerations, and some minor lesions on the snout and anus. In addition, we observed the same wasp species preying on larvae of Sarcophagidae (Peckia sp.). Besides causing postmortem injuries, the ability of this species to detect carcasses in the early and fresh decomposition stages should be noted. Thus, future applications aiming criminal, any biotaphonomic events caused by carrion insects need to be disclosed.
Resumo:
Multidetector computed tomography is becoming more widespread in forensic medicine. In most services, autopsy assistants perform the radiological examination. We introduced professional radiographers into the legal medicine service and hypothesized they would also be able to take over duties currently reserved for other specialists. The aims of this study were to evaluate if radiographers could be trained as "forensic radiographers" by (1) integrating graduated medical radiographers into the legal medicine service, (2) investigating the advantages of this collaboration, and (3) defining the duties of the forensic radiographers.The study was performed prospectively on a group of 8 recruited radiographers who underwent a testing period with special training. They learned the basics of medicolegal case treatment, the autonomous execution of postmortem computed tomography angiography, and postprocessing of data. Seven of 8 radiographers finished the training and were integrated into our service. Although all radiographers were able to fulfill the duties demanded after the training period, some radiographers could not enter or complete the program because they were unable to work with dead bodies.Our study presents the advantages of integrating radiographers into the medicolegal team and proposes how to train the forensic radiographers. In addition, the duties and responsibilities of these new specialists are defined.