930 resultados para false negative rate


Relevância:

80.00% 80.00%

Publicador:

Resumo:

We develop a general model for adaptive c, np, u and p control charts in which one, two or three design parameters (sample size, sampling interval and control limit width) switch between two values, according to the most recent process information. For a given in-control average sampling rate and a given false alarm rate, the adaptive chart detects changes in the process much faster than a chart with fixed parameters. Moreover, this study also offers general guidance on how to choose an effective design.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fluorescence diagnosis of malignant lesions has been showed as an attractive optical technique due especially to its real-time response and a more objective and quantitative evaluation. Even though the oral cavity allows a direct examination many lesions are diagnosed when it is already in advanced stage, compromising the patient prognosis. In this study, the fluorescence spectroscopy was used to the detection of chemically induced carcinoma at the lateral border of the tongue in a hamster model. Two excitations wavelengths in visible region were applied: 442 and 532 nm. All the spectra results were analyzed comparing with the histopathological diagnosis. The better results were achieved with the 442 nm laser excitation. The spectra from carcinoma showed new emission bands and these were used to determined different ratios for a quantitative analysis. Using the 625-645 nm fluorescence range under 442 nm excitation (A3 coefficient) the percentage of false negative was of 9.1%, however the false positive percentage was of 18.5%. The 532 nm excitation provided a better normal tissue detection compared to 442 nm excitation. The ideal clinical condition is probably the use of multiple wavelengths excitation for a broader tissue fluorescence investigation.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This work aims to investigate the efficiency of digital signal processing tools of acoustic emission signals in order to detect thermal damages in grinding processes. To accomplish such a goal, an experimental work was carried out for 15 runs in a surface grinding machine operating with an aluminum oxide grinding wheel and ABNT 1045 Steel as work material. The acoustic emission signals were acquired from a fixed sensor placed on the workpiece holder. A high sampling rate data acquisition system working at 2.5 MHz was used to collect the raw acoustic emission instead of the root mean square value usually employed. Many statistical analyses have shown to be effective to detect burn, such as the root mean square (RMS), correlation of the AE, constant false alarm rate (CFAR), ratio of power (ROP) and mean-value deviance (MVD). However, the CFAR, ROP, Kurtosis and correlation of the AE have been presented more sensitive than the RMS. Copyright © 2006 by ABCM.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In this work, a new approach for supervised pattern recognition is presented which improves the learning algorithm of the Optimum-Path Forest classifier (OPF), centered on detection and elimination of outliers in the training set. Identification of outliers is based on a penalty computed for each sample in the training set from the corresponding number of imputable false positive and false negative classification of samples. This approach enhances the accuracy of OPF while still gaining in classification time, at the expense of a slight increase in training time. © 2010 Springer-Verlag.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Background: We evaluated the presence of ductal carcinoma in situ (DCIS) in core needle biopsies (CNB) from invasive ductal lesions. Methods: Retrospective study, which analyzed 90 cases of invasive ductal carcinoma lesions. The percentage of DCIS was quantified in each specimens obtained from CNB, which were compared to the surgical specimens. CNB and surgical specimens were evaluated by the same pathologist, and the percentage of DCIS in CNB was evaluated (percentage) and divided into categories. We considered the following parameters regarding the amount of DCIS: 1 = 0; 2 = 1 for 5%; 3 = 6 for 24%; 4 = 25 for 50%; 5 = 51 for 75% and 6 = 76 for 99%. The number of fragments and the histological pattern of DCIS was found. Results: We found the following results regarding the distribution of the percentage of DCIS in the CNB: 1 = 63.3%; 2 = 12.2%; 3 = 12.2%; 4 = 5.6%; 5 = 1.1% and 6 = 5.6%. The logistic regression analysis showed that CNB percentages above 45% reflected the presence of DCIS in the surgical specimen in 100% of the cases (p<0.001), with a specificity of 100%, accuracy of 83.3% and false positive rate of 0% (p <0.001). Conclusion: There is direct relationship between extensive intraductal component in the surgical specimen when the core biopsy shows 45% or more of the DCI or microinvasive in the material examined. © 2012 Barbalaco Neto et al.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The most important pathogens in the bovine livestock nowadays in the virus of the viral diarrhea mainly for triggered clinical manifestations related to the reproductive sphere. The infection in pregnant females, may result in abortions, embryonic resorptions, fetal mummification, birth of weak and malformation of the cattle. Moreover, their birth with persistently infected and immunotolerant virus, which the source of infection and dissemination of their disease. Nowadays, the complexity of the diagnosis and consequently its pathogenesis are tilted in the genotypic differences agent. So, this study aimed to verify the occurrence of the BVDV-1 (SINGER) and BVDV-2 (VS-253) genotypes in cows and their respective fetuses, slaughtered in an abattoir in the State of Sao Paulo. Through blood serum, using virus neutralization technique. All in all, 52,51% (115/219) of the cows which were tested reacted, but no fetus (0/219) reacted, to its virus neutralization. Through this cross-examination we observed that 42% (92/219) of cows reacted for both BVDV-1 and BVDV-2. Furthermore 4,10% (9/219) of them reacted only to the genotype BVDV-1 and 6,39% (14/219) responded only to the genotype 2 of BVDV. Therefore it was noticed that both strains are widespread in the regions studied, which justifies the use of different antigens to avoid false-negative diagnosis. Finally antibodies showed no fetus or fetal abnormalities, it is already developed and can be considered immunocompetent, independent child born to a reagent.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Plasmatic concentrations of von Willebrand Factor (vWF) increase during pregnancy in humans and dogs; however the mechanism of such increase is still not well defined. The aims of this study were: (i) to evaluate changes in vWF concentration during pregnancy and during the subsequent oestrous cycle in bitches affected and unaffected by von Willebrand Disease (vWD); (ii) to correlate the vWF levels and cortisol levels in both groups. Seven vWD affected (GI) and nine unaffected (GII) bitches were used. The animals were assessed during pregnancy, parturition, lactation and non-gestational oestrous cycle in 11 moments (Pregnancy 1, Pregnancy 2, Parturition, Lactation 1, Lactation 2, Lactation 3, Anestrus, Proestrus, Oestrus, Diestrus 1, and Diestrus 2). The following tests were performed; measurement of von Willebrand factor antigen (vWF:Ag), albumin and cortisol. In both groups, vWF concentration remained stable during the non-gestational oestrous cycle, but increased during pregnancy, with the highest value observed at parturition. Increases of 70% and 124% in vWF were seen in GI and GII, respectively, compared to anestrus. No correlation was found between vWF and cortisol. Values of vWF:Ag changed during pregnancy, with a peak at parturition, both in vWD affected and unaffected animals. Values of vWF were not altered in the different phases of the oestrous cycle following pregnancy in both groups. Evaluation of vWF during pregnancy can cause false negative results for vWD, but assessment can be performed at any point in the oestrous cycle of non-pregnant bitches. © 2012 Blackwell Verlag GmbH.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Williams-Beuren syndrome (WBS) is a genetic disorder characterized by physical and intellectual developmental delay, associated with congenital heart disease and facial dysmorphism. WBS is caused by a microdeletion on chromosome 7 (7q11.23), which encompasses the elastin (ELN) gene and about 27 other genes. The gold standard for WBS laboratory diagnosis is FISH (fluorescence in situ hybridization), which is very costly. As a possible alternative, we investigated the accuracy of three clinical diagnostic scoring systems in 250 patients with WBS diagnosed by FISH. We concluded that all three systems could be used for the clinical diagnosis of WBS, but they all gave a low percentage of false-positive (6.0-9.2%) and false-negative (0.8-4.0%) results. Therefore, their use should be associated with FISH testing. © FUNPEC-RP.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Pós-graduação em Medicina Veterinária - FMVZ

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Pós-graduação em Medicina Veterinária - FMVZ

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A baciloscopia de escarro é o exame mais difundido para o diagnóstico e controle da Tuberculose (TB), por ser um método de simples execução e de baixo custo, porém possui baixa sensibilidade e especificidade. Para que a eficácia e eficiência deste método sejam atingidas, é necessário o estabelecimento e aplicações de normas padrão de execução e leitura de lâminas. Nesse sentido, é fundamental conhecer a qualidade do exame baciloscópico disponível em uma rede de laboratórios. O objetivo deste estudo foi avaliar a qualidade das baciloscopias para diagnóstico e controle da TB realizadas nas Unidades Laboratoriais (UL) pertencentes à rede pública de laboratórios do município de Belém, Pará, no ano 2007, 2008 e 2009. A avaliação foi dividida em três etapas, correspondentes ao ano de confecção das lâminas. Participaram 18 UL que enviaram, regularmente, ao Laboratório Central do Pará, todas as lâminas de baciloscopia confeccionadas por elas para a Avaliação Externa da Qualidade da Baciloscopia (AEQB), que utiliza o método de releitura cega dos esfregaços. Este método compreende uma avaliação técnica dos esfregaços, classificando-os como “Adequados” e “Inadequados”, além da análise de discordância de resultados Falso positivo (FP) e Falso negativo (FN). No período do estudo, 4.117 lâminas foram processadas pelas UL. Na 1ª etapa de avaliação, todas as 18 UL apresentaram lâminas que foram classificadas como inadequadas, sendo que este número diminuiu para 12 UL na 2ª etapa de avaliação e para seis UL na 3ª etapa. Em relação às discordâncias, 03 UL apresentaram discordâncias de FP e 03 UL de FN. Os resultados obtidos no estudo reforçam a necessidade de manter e expandir a AEQB para todas as UL que realizam baciloscopia na rede de laboratórios.