981 resultados para correlation methods


Relevância:

30.00% 30.00%

Publicador:

Resumo:

In studies on the evaluation of methodologies for the analysis of soil, phosphorus (P) has been the single most studied aspect, due to the complexity of this dynamic element in soil. However, these studies have been limited regarding soil conditions in Paranaa. The present study aimed to evaluate the efficiency of the Mehlich-1, Mehlich-3 and ion exchange resin methods in the evaluation of available P for soybean (Glycine max) in the soils of Paranaa State. Twelve soil samples collected from the upper 0-20 cm were planted with soybean for a period of 42 days in the greenhouse. The ability to extract soil P followed the order of decreasing average amount of extracted P: Mehlich-3 > resin > Mehlich-1. The correlation coefficients between the content of P extracted by Mehlich-1, Mehlich-3 and resin and the amount of P accumulated in the plants were 0.86, 0.90 and 0.93, respectively. Mehlich-1, Mehlich-3 and resin showed similar efficiency in the evaluation of P availability to plants and, under conditions of natural fertility and in soils that had received no application of poorly natural reactive phosphates, can be used to quantify the concentrations of P in the soils of Parana State.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: It was reported that autonomic nervous system function is altered in subjects with chronic obstructive pulmonary disease (COPD). We evaluated short-and long-term fractal exponents of heart rate variability (HRV) in COPD subjects.Patients and methods: We analyzed data from 30 volunteers, who were divided into two groups according to spirometric values: COPD (n = 15) and control (n = 15). For analysis of HRV indices, HRV was recorded beat by beat with the volunteers in the supine position for 30 minutes. We analyzed the linear indices in the time (SDNN [standard deviation of normal to normal] and RMSSD [root-mean square of differences]) and frequency domains (low frequency [LF], high frequency [HF], and LF/HF), and the short-and long-term fractal exponents were obtained by detrended fluctuation analysis. We considered P < 0.05 to be a significant difference.Results: COPD patients presented reduced levels of all linear exponents and decreased short-term fractal exponent (alpha-1: 0.899 +/- 0.18 versus 1.025 +/- 0.09, P = 0.026). There was no significant difference between COPD and control groups in alpha-2 and alpha-1/alpha-2 ratio.Conclusion: COPD subjects present reduced short-term fractal correlation properties of HRV, which indicates that this index can be used for risk stratification, assessment of systemic disease manifestations, and therapeutic procedures to monitor those patients.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

O losartano potássico é um agente anti-hipertensivo não peptídico, que exerce sua ação por bloqueio específico dos receptores da angiotensina II. Este trabalho propôs a validação e aplicação de métodos analíticos orientados ao controle de qualidade de losartano potássico 50 mg na forma farmacêutica cápsula, utilizando a espectrofotometria direta e derivada de primeira ordem na região do UV. Baseado nas características espectrofotométricas de losartano potássico, um sinal a 205 nm do espectro de ordem zero e um sinal a 234 nm do espectro de primeira derivada foram adequados para a quantificação. Os resultados foram usados para comparar essas duas técnicas instrumentais. O coeficiente de correlação entre as respostas e as concentrações de losartano potássico na faixa de 3,0-7,0 mg L-1 e 6,0-14,0 mg L-1 para espectrofotometria direta e derivada de primeira ordem em solução aquosa, respectivamente, foi de (r) of 0,9999 para ambos os casos. Os métodos foram aplicados para quantificação de losartano potássico em cápsulas obtidas de farmácias de manipulação locais e demonstraram ser eficientes, fáceis de aplicar e de baixo custo. Além disso, não necessitam de reagentes poluentes e requerem equipamentos economicamente viáveis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The general assumption under which the (X) over bar chart is designed is that the process mean has a constant in-control value. However, there are situations in which the process mean wanders. When it wanders according to a first-order autoregressive (AR (1)) model, a complex approach involving Markov chains and integral equation methods is used to evaluate the properties of the (X) over bar chart. In this paper, we propose the use of a pure Markov chain approach to study the performance of the (X) over bar chart. The performance of the chat (X) over bar with variable parameters and the (X) over bar with double sampling are compared. (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aim. One of the major causes of chronic venous disease is venous reflux, the identification and quantification of which are important for diagnosis. Duplex scanning allows for the detection and quantification of reflux in individual veins. Evaluation of the great saphenous vein in primary varicosis is necessary for its preservation. Objective of the study is to evaluate a possible correlation between the intensity of reflux at the saphenofemoral junction, diameter alterations of the incompetent great saphenous vein and the practical effect of such correlation. Also to compare the clinical severity of the CEAP classification with such parameters.Methods. Three hundred limbs were submitted to duplex evaluation of their insufficient saphenous veins. Vein diameter was measured on five different points. Velocity and flow at reflux peak and reflux time were determined. The saphenous vein's diameters were correlated with velocity, flow and time. The three latter parameters and diameters were compared with clinical severity according to CEAP.Results. Correlation was found between the saphenous vein's diameters, velocity and flow. No correlation was observed between time and diameter in the thigh's upper and middle thirds. When comparing diameter, velocity and flow with CEAP clinical severity classification, an association was observed. The correlation between reflux time with clinical severity was weak.Conclusion. Reflux time is a good parameter for identifying the presence of reflux, but not for quantifying it. Velocity and peak flow were better parameters for evaluating reflux intensity as they were correlated with great saphenous vein alterations, and were associated with the disease's clinical severity. [Int Angiol 2010;29:323-30]

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective. The purpose of this study was to test the correlation of the amount of Atopobium vaginae with the most commonly used markers for bacterial vaginosis (BV).Materials and Methods. We enrolled 103 nonpregnant and premenopausal women that were positive for BV by Amsel criteria and with a Nugent score higher than 3. All women were negative for yeast, Chlamydia trachomatis, Trichomonas vaginalis, and Neisseria gonorrhoeae. A. vaginae concentration was determined by quantitative polymerase chain reaction from samples of vaginal rinsings with 2 mL of sterile saline.Results. There was no difference in the median values of A. vaginae concentration when comparing samples with presence or absence of each individual Amsel criterion. In the case of a higher pH cutoff value of 4.9, greater amounts of this microorganism (p = .02) were found. In addition, correlation tests showed that A. vaginae concentration is positively correlated with pH (p < .001) and with Nugent scores (p = .003).Conclusions. The quantification of A. vaginae is useful for identification of the most severe cases of BV.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study compared the performance of fluorescence-based methods, radiographic examination, and International Caries Detection and Assessment System (ICDAS) II on occlusal surfaces. One hundred and nineteen permanent human molars were assessed twice by 2 experienced dentists using the laser fluorescence (LF and LFpen) and fluorescence camera (FC) devices, ICDAS II and bitewing radiographs (BW). After measuring, the teeth were histologically prepared and assessed for caries extension. The sensitivities for dentine caries detection were 0.86 (FC), 0.78 (LFpen), 0.73 (ICDAS II), 0.51 (LF) and 0.34 (BW). The specificities were 0.97 (BW), 0.89 (LF), 0.65 (ICDAS II), 0.63 (FC) and 0.56 (LFpen). BW presented the highest values of likelihood ratio (LR)+ (12.47) and LR- (0.68). Rank correlations with histology were 0.53 (LF), 0.52 (LFpen), 0.41 (FC), 0.59 (ICDAS II) and 0.57 (BW). The area under the ROC curve varied from 0.72 to 0.83. Inter- and intraexaminer intraclass correlation values were respectively 0.90 and 0.85 (LF), 0.93 and 0.87 (LFpen) and 0.85 and 0.76 (FC). The ICDAS II kappa values were 0.51 (interexaminer) and 0.61 (intraexaminer). The BW kappa values were 0.50 (interexaminer) and 0.62 (intraexaminer). The Bland and Altman limits of agreement were 46.0 and 38.2 (LF), 55.6 and 40.0 (LFpen) and 1.12 and 0.80 (FC), for intra- and interexaminer reproducibilities. The posttest probability for dentine caries detection was high for BW and LF. In conclusion, LFpen, FC and ICDAS II presented better sensitivity and LF and BW better specificity. ICDAS II combined with BW showed the best performance and is the best combination for detecting caries on occlusal surfaces. Copyright (C) 2008 S. Karger AG, Basel.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJETIVO: Investigar as alterações laríngeas e vocais em pacientes com sintomas de refluxo gastroesofágico e correlacioná-las com o exame de phmetria. MÉTODOS: Estudo prospectivo que incluiu os pacientes atendidos nos ambulatórios de Distúrbios da Voz da Faculdade de Medicina de Botucatu no período de cinco anos com sintomas vocais e gastroesofágicos. Os pacientes foram submetidos à videolaringoscopia, às análises vocais perceptivo-auditivas, a analise vocal acústica computadorizada e ao exame de pHmetria de dois canais com monitorização durante 24 horas. RESULTADOS: Foram incluídos 57 pacientes (entre 21 a 65 anos; 45 mulheres e 12 homens). Desses, 18 apresentavam pHmetria normal (31,6%) e 39 alterada (68,4%). As videolaringoscopias registraram diversas lesões laríngeas tanto nos pacientes com pHmetria normal como alterada, sendo mais relevantes neste último grupo, destacando-se a paquidermia posterior. As avaliações vocais perceptivo-auditivas identificaram alterações vocais de diversas intensidades em ambos os grupos, mais importantes nos pacientes com pHmetria alterada. Todos os parâmetros acústicos, exceto Fo, mostraram-se alterados em ambos os grupos, quando comparados aos controles. CONCLUSÕES: Alterações vocais perceptivas e acústicas, e lesões laríngeas foram registradas tanto nos pacientes com phmetria normal como alterada, sinalizando para a importância da historia clínica e dos achados videolaringoscópicos no diagnóstico das laringites ácidas.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)