1000 resultados para contaminação ambiental


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Leaking of hydrocarbon in fuel underground storage tanks constitute object of concern for urban environmental management, because therefore they provoke damages to the physical, biological and socioeconomic environment. Though laws that regulate this essential activity exist, aiming at to prevent contamination with hydrocarbon, we observe that this still happens. This fact evidences that the selection of places for installation of gas stations has not considered the characteristics of the natural environment, implying in more critical consequences associated to the leaking. The objective of this work is to elaborate a chart applied to the gas stations in Rio Claro/SP. The determination of the Index of Environmental Sensitivity for elaboration of such chart was carried through breaking the selection of factors of Environmental Sensitivity of physical, biological and socioeconomic environment. The balance of these factors was given by means of Ad hoc consultation. The crossing of the information was carried through using the method of overlapping of overlays. The result is a chart that shows us areas with classes of high, middle and low Environmental Sensitivity. One gives credit that this type of material can be used as criterion in the selection of adjusted areas for installations of new gas stations and management of the already installed gas stations. The diagnosis of the current situation of the gas stations in the area and recommendations had also been elaborated.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Economic activities, whether large or small, can cause a range of environmental changes, not always reversible, harming society and its quality of life. Many potentially polluting activities have already been installed in various Brazilian cities, just as at the industrial district of Rio Claro / SP, which allow the synthesis of the many environmental impacts. In this sense, this report aims to make an environmental assessment in the influence area of the industrial district of Rio Claro / SP, located in the urban area of the city. As a result, the existence of prior related studies was observed, especially the diagnosis and study of the many implications that arises from activities impacting, and further, there was a demarcation of the influence area of the district and its derivatives impacts in the influence area, the steps of prediction and mitigation measures and if these activities meet the minimum technical requirements in planning and environmental applicable legislation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Geophysics studies in areas impacted by petroleum derivatives describe abnormalities of both low and high electrical resistivity (the opposite of electrical conductivity), confirmed as contaminant phase by chemical analysis: this contradiction can be explained by degrading processes that naturally occur and create sub products that can change the environment conductivity. Monitoring the variation of the parameters mentioned serves as a comparative basis to the variation in geoelectrical parameters, which identified the correlation between the same contaminant parameters and the difference between their behavior studied apart, as well as its relations with the biodegradation process. The results are applied to the fuel distribution and storage sectors, leading to the diagnosis and monitoring of possible groundwater contamination scenarios, and the knowledge of the area exposure time to the contaminant, besides the better remediation alternative and impacts control. Among some conclusions, the most significant are the decrease in conductivity over time, so as the increase in Eh value in the gasoline contaminated tank, as well as the decrease in the pH value in the second tank with ethanol, which can be attributed to its degradation. Comparing the variations in both tanks, it is evident that Eh, pH and electrical conductivity do not behave temporally in a similar way, although some correlations between Eh and pH can be related.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Civil e Ambiental - FEB

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Civil e Ambiental - FEB

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The contamination of the physical environment occurs as a result of the lack of planning and inadequate management of hazardous products. Due to the difficulty of the characterization and study of soil and groundwater, the contamination has been long neglected. The characterization of these areas by research techniques through direct methods such as physical and chemical analysis, are widely used in the diagnosis and monitoring. However, despite presenting quantitative results, this method is not representative in spatial terms. The purpose of this work is to bring geophysical complementation with the diagnosis, bringing the spatial element for the detection of the contamination plume. In the study area, there was a railway accident in 1999 in which three wagons fell and spilled 240,000 L of diesel onto the soil. The main objective is to assess the presence of contaminants in the residual phase and dissolved in the subsurface, using the technique of Electrical Tomography (ETR), understand the effects of natural attenuation process in the degradation of hydrocarbons and changes in electrical properties in soil and groundwater. The results allowed the definition of three distinct patterns of resistivity region with presence of dissolved phase, set in a historical chemical analyzes: low values (> 60Ω.m) associated with the presence of hydrocarbons in an advanced stage of degradation, intermediate values (260Ω.me 511Ω .m) indicative of coexistence of residual hydrocarbons and dissolved phase, and high values (> 1000Ω.m), which reveal the prevalence of residual phase with incipient degradation, possibly in high toxicity concentrations for effective action of biodegradation processes. The diagnostic of areas with potential accumulation of residual phase can subsidize the planning of remediation techniques and promote the complete decontamination of the area

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Cryptococcosis is an opportunistic fungal infection caused by Cryptococcus yeasts, especially C. neoformans and Cryptococcus gattii. The fungus is found in substrates of animal and vegetable origin, and infection occurs through inhalation and seedlings present in the environment. The present study aimed to investigate the existence of microfocus Cryptococcus sp. from the environmental samples of Araçatuba city, São Paulo, featuring new niches, by decoupling the direct relationship between fungus and host in order to minimize the risk of contamination of man and animals, understanding the ecoepidemiology of Cryptococcus. Fifty samples from hollows and tree trunks were harvested (Cassia sp., Ficus sp., Caesalpinea peltophorides) from ten representatives in the urban perimeter. The samples were immediately sent to the Laboratory of Bacteriology and Mycology, Faculty of Veterinary Medicine Araçatuba - Unesp where they were processed and plated on Petri dishes containing agar seed Niger and Sabouraud dextrose agar with chloramphenicol, incubated at 30ºC for a period of no less than 5 days. Afterwards they were subimitted to biochemical tests: urease production, thermotolerance at 37°C and quimiotipagem in CGB agar (L- Canavanine-Glycine-Bromothymol blue). The results showed that 17 (34%) cultures were positive for Cryptococcus, 9 (18%) for Cryptococcus gattii and 8 (16%) for Cryptococcus neoformans. Other yeast correlated as Rhodotorula sp. and Candida sp. were isolated. We conclude that the infectious propagules of Cryptococcus are dispersed in nature and constitute an environmental microfocus, not necessarily being bound to a single host.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Civil e Ambiental - FEB

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Devido à constante preocupação do meio ambiente, o uso de fluidos de corte tem se tornado um problema para a indústria mecânica atual por se tratar de substâncias tóxicas. Seu uso e sua dificuldade de descarte devido rígida Legislação Ambiental, faz com que o fluido de corte seja responsável por uma grande parte do custo final do processo, provocando, desse modo, um grande interesse em pesquisas referentes a métodos alternativos de forma e quantidade de fluido de corte utilizado. Ao lado das vantagens tecnológicas associadas com o uso dos fluidos de corte estão os enormes perigos atrelados a estes, e que são nocivos ao meio ambiente e à saúde das pessoas. A contaminação do solo, água e ar podem decorrer de vazamentos e perdas, emissões, água de lavagem e da própria disposição dos fluidos de corte.Os componentes dos fluidos de corte como bactericidas e fungicidas reagem com outros produtos inseridos no processo de corte, tornando os fluidos, materiais que podem vir a causar doenças. Assim, este trabalho tem como objetivo apresentar a utilização do fluido de corte por mínima quantidade de lubrificação como alternativa para se minimizar o impacto ambiental das indústrias mecânicas.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A expansão urbana acarreta a necessidade de mitigações ambientais, em que um planejamento do uso do solo, bem como seu processo de ocupação traz a necessidade também de estudos para viabilizar tais ações. Nesse processo de expansão, os cemitérios necessitam de maiores atenções, já que evidenciaram indícios de contaminações no solo e fontes de água próximas. Atualmente, o CONAMA (Conselho Nacional de Meio Ambiente) possui duas resoluções que discorrem sobre os aspectos construtivos, visando controlar os resíduos existentes, tais como o Liquame da Coliquação (também conhecido por Necrochorume), um dos responsáveis pela contaminação do solo e aquíferos subterrâneos. Tendo esse escopo em pauta, este trabalho exibe um levantamento da legislação que incide sobre a implantação e regularização de cemitérios no estado de São Paulo.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Civil e Ambiental - FEB

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)