921 resultados para bioluminescence imaging


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Anterior cruciate ligament (ACL) tear is a common sports injury of the knee. Arthroscopic reconstruction using autogenous graft material is widely used for patients with ACL instability. The grafts most commonly used are the patellar and the hamstring tendons, by various fixation techniques. Although clinical evaluation and conventional radiography are routinely used in follow-up after ACL surgery, magnetic resonance imaging (MRI) plays an important role in the diagnosis of complications after ACL surgery. The aim of this thesis was to study the clinical outcome of patellar and hamstring tendon ACL reconstruction techniques. In addition, the postoperative appearance of the ACL graft was evaluated using several MRI sequences. Of the 175 patients who underwent an arthroscopically assisted ACL reconstruction, 99 patients were randomized into patellar tendon (n=51) or hamstring tendon (n=48) groups. In addition, 62 patients with hamstring graft ACL reconstruction were randomized into either cross-pin (n=31) or interference screw (n=31) fixation groups. Follow-up evaluation determined knee laxity, isokinetic muscle performance and several knee scores. Lateral and anteroposterior view radiographs were obtained. Several MRI sequences were obtained with a 1.5-T imager. The appearance and enhancement pattern of the graft and periligamentous tissue, and the location of bone tunnels were evaluated. After MRI, arthroscopy was performed on 14 symptomatic knees. The results revealed no significant differences in the 2-year outcome between the groups. In the hamstring tendon group, the average femoral and tibial bone tunnel diameter increased during 2 years follow-up by 33% and 23%, respectively. In the asymptomatic knees, the graft showed homogeneous and low signal intensity with periligamentous streaks of intermediate signal intensity on T2-weighted MR images. In the symptomatic knees, arthroscopy revealed 12 abnormal grafts and two meniscal tears, each with an intact graft. Among 3 lax grafts visible on arthroscopy, MRI showed an intact graft and improper bone tunnel placement. For diagnosing graft failure, all MRI findings combined gave a specificity of 90% and a sensitivity of 81%. In conclusion, all techniques appeared to improve patients' performance, and were therefore considered as good choices for ACL reconstruction. In follow-up, MRI permits direct evaluation of the ACL graft, the bone tunnels, and additional disorders of the knee. Bone tunnel enlargement and periligamentous tissue showing contrast enhancement were non-specific MRI findings that did not signify ACL deficiency. With an intact graft and optimal femoral bone tunnel placement, graft deficiency is unlikely, and the MRI examination should be carefully scrutinized for possible other causes for the patients symptoms.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Wildlife conservation involves an understanding of a specific animal, its environment and the interaction within a local ecosystem. Unmanned Aerial Vehicles (UAVs) present cost effective, non-intrusive solution for detecting animals over large areas and the use thermal imaging cameras offer the ability detect animals that would otherwise be concealed to visible light cameras. This report examines some of limitations on using SURF for the development of large maps using multiple stills images extracted from the thermal imaging video camera which contain wildlife (eg. Koala in them).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

[1] We have compared the spectral aerosol optical depth (AOD, tau lambda) and aerosol fine mode fraction (AFMF) of Collection 004 (C004) derived from Moderate-Resolution Imaging Spectroradiometer (MODIS) on board National Aeronautics and Space Administration's (NASA) Terra and Aqua platforms with that obtained from Aerosol Robotic Network (AERONET) at Kanpur (26.45 degrees N, 80.35 degrees E), India for the period 2001-2005. The spatially-averaged (0.5 degrees x 0.5 degrees centered at AERONET sunphotometer) MODIS Level-2 aerosol parameters (10 km at nadir) were compared with the temporally averaged AERONET-measured AOD (within +/- 30 minutes of MODIS overpass). We found that MODIS systematically overestimated AOD during the pre-monsoon season (March to June, known to be influenced by dust aerosols). The errors in AOD at 0.66 mu m were correlated with the apparent reflectance at 2.1 mu m (rho*(2.1)) which MODIS C004 uses to estimate the surface reflectance in the visible channels (rho(0.47) = rho*(2.1)/ 4, rho(0.66) = rho*(2.1)/ 2). The large errors in AOD (Delta tau(0.66) > 0.3) are found to be associated with the higher values of rho*(2.1) (0.18 to 0.25), where the uncertainty in the ratios of reflectance is large (Delta rho(0.66) +/- 0.04, Delta rho(0.47) +/- 0.02). This could have resulted in lower surface reflectance, higher aerosol path radiance and thus lead to overestimation in AOD. While MODIS-derived AFMF has binary distribution (1 or 0) with too low (AFMF < 0.2) during dust-loading period, and similar to 1 for the rest of the retrievals, AERONET showed range of values (0.4 to 0.9). The errors in tau(0.66) were also high in the scattering angle range 110 degrees - 140 degrees, where the optical effects of nonspherical dust particles are different from that of spherical particles.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Acute pain has substantial survival value because of its protective function in the everyday environment. Instead, chronic pain lacks survival and adaptive function, causes great amount of individual suffering, and consumes the resources of the society due to the treatment costs and loss of production. The treatment of chronic pain has remained challenging because of inadequate understanding of mechanisms working at different levels of the nervous system in the development, modulation, and maintenance of chronic pain. Especially in unclear chronic pain conditions the treatment may be suboptimal because it can not be targeted to the underlying mechanisms. Noninvasive neuroimaging techniques have greatly contributed to our understanding of brain activity associated with pain in healthy individuals. Many previous studies, focusing on brain activations to acute experimental pain in healthy individuals, have consistently demonstrated a widely-distributed network of brain regions that participate in the processing of acute pain. The aim of the present thesis was to employ non-invasive brain imaging to better understand the brain mechanisms in patients suffering from chronic pain. In Study I, we used magnetoencephalography (MEG) to measure cortical responses to painful laser stimulation in healthy individuals for optimization of the stimulus parameters for patient studies. In Studies II and III, we monitored with MEG the cortical processing of touch and acute pain in patients with complex regional pain syndrome (CRPS). We found persisting plastic changes in the hand representation area of the primary somatosensory (SI) cortex, suggesting that chronic pain causes cortical reorganization. Responses in the posterior parietal cortex to both tactile and painful laser stimulation were attenuated, which could be associated with neglect-like symptoms of the patients. The primary motor cortex reactivity to acute pain was reduced in patients who had stronger spontaneous pain and weaker grip strength in the painful hand. The tight coupling between spontaneous pain and motor dysfunction supports the idea that motor rehabilitation is important in CRPS. In Studies IV and V we used MEG and functional magnetic resonance imaging (fMRI) to investigate the central processing of touch and acute pain in patients who suffered from recurrent herpes simplex virus infections and from chronic widespread pain in one side of the body. With MEG, we found plastic changes in the SI cortex, suggesting that many different types of chronic pain may be associated with similar cortical reorganization. With fMRI, we found functional and morphological changes in the central pain circuitry, as an indication of central contribution for the pain. These results show that chronic pain is associated with morphological and functional changes in the brain, and that such changes can be measured with functional imaging.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cardiovascular diseases (CVD) are, in developed countries, the leading cause of mortality. The majority of premature deaths and disability caused by CVD are due to atherosclerosis, a degenerating inflammatory disease affecting arterial walls. Early identification of lesions and initiation of treatment is crucial because the first manifestations quite often are major disabling cardiovascular events. Methods of finding individuals at high risk for these events are under development. Because magnetic resonance imaging (MRI) is an excellent non-invasive tool to study the structure and function of vascular system, we sought to discover whether existing MRI methods are able to show any difference in aortic and intracranial atherosclerotic lesions between patients at high risk for atherosclerosis and healthy controls. Our younger group (age 6-48) comprised 39 symptomless familial hypercholesterolemia (FH) patients and 25 healthy controls. Our older group (age 48-64) comprised 19 FH patients and 18 type 2 diabetes mellitus (DM) patients with coronary heart disease (CHD) and 29 healthy controls. Intracranial and aortic MRI was compared with carotid and femoral ultrasound (US). In neither age-group did MRI reveal any difference in the number of ischemic brain lesions or white matter hyperintensities (WMHIs) - possible signs of intracranial atherosclerosis - between patients and controls. Furthermore, MRI showed no difference in the structure or function of the aorta between FH patients and controls in either group. DM patients had lower compliance of the aorta than did controls, while no difference appeared between DM and FH patients. However, ultrasound showed greater plaque burden and increased thickness of carotid arterial walls in FH and DM patients in both age-groups, suggesting a more advanced atherosclerosis. The mortality of FH patients has decreased substantially after the late 1980´s when statin treatment became available. With statins, the progression of atherosclerotic lesions slows. We think that this, in concert with improvements in treatment of other risk factors, is one reason for the lack of differences between FH patients and controls in MRI measurements of the aorta and brain despite the more advanced disease of the carotid arteries assessed with US. Furthermore, whereas atherosclerotic lesions between different vascular territories correlate, differences might still exist in the extent and location of these lesions among different diseases. Small (<5 mm in diameter) WMHIs are more likely a phenomenon related to aging, but the larger ones may be the ones related to CVD and may be intermediate surrogates of stroke. The image quality in aortic imaging, although constantly improving, is not yet optimal and thus is a source of bias.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Acute knee injury is a common event throughout life, and it is usually the result of a traffic accident, simple fall, or twisting injury. Over 90% of patients with acute knee injury undergo radiography. An overlooked fracture or delayed diagnosis can lead to poor patient outcome. The major aim of this thesis was retrospectively to study imaging of knee injury with a special focus on tibial plateau fractures in patients referred to a level-one trauma center. Multi-detector computed tomography (MDCT) findings of acute knee trauma were studied and compared to radiography, as well as whether non-contrast MDCT can detect cruciate ligaments with reasonable accuracy. The prevalence, type, and location of meniscal injuries in magnetic resonance imaging (MRI) were evaluated, particularly in order to assess the prevalence of unstable meniscal tears in acute knee trauma with tibial plateau fractures. The possibility to analyze with conventional MRI the signal appearance of menisci repaired with bioabsorbable arrows was also studied. The postoperative use of MDCT was studied in surgically treated tibial plateau fractures: to establish the frequency and indications of MDCT and to assess the common findings and their clinical impact in a level-one trauma hospital. This thesis focused on MDCT and MRI of knee injuries, and radiographs were analyzed when applica-ble. Radiography constitutes the basis for imaging acute knee injury, but MDCT can yield information beyond the capabilities of radiography. Especially in severely injured patients , sufficient radiographs are often difficult to obtain, and in those patients, radiography is unreliable to rule out fractures. MDCT detected intact cruciate ligaments with good specificity, accuracy, and negative predictive value, but the assessment of torn ligaments was unreliable. A total of 36% (14/39) patients with tibial plateau fracture had an unstable meniscal tear in MRI. When a meniscal tear is properly detected preoperatively, treatment can be combined with primary fracture fixation, thus avoiding another operation. The number of meniscal contusions was high. Awareness of the imaging features of this meniscal abnormality can help radiologists increase specificity by avoiding false-positive findings in meniscal tears. Postoperative menisci treated with bioabsorbable arrows showed no difference, among different signal intensities in MRI, among menisci between patients with operated or intact ACL. The highest incidence of menisci with an increased signal intensity extending to the meniscal surface was in patients whose surgery was within the previous 18 months. The results may indicate that a rather long time is necessary for menisci to heal completely after arrow repair. Whether the menisci with an increased signal intensity extending to the meniscal surface represent improper healing or re-tear, or whether this is just the earlier healing feature in the natural process remains unclear, and further prospective studies are needed to clarify this. Postoperative use of MDCT in tibial plateau fractures was rather infrequent even in this large trauma center, but when performed, it revealed clinically significant information, thus benefitting patients in regard to treatment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The structure and operation of CdTe, CdZnTe and Si pixel detectors based on crystalline semiconductors, bump bonding and CMOS technology and developed mainly at Oy Simage Ltd. And Oy Ajat Ltd., Finland for X- and gamma ray imaging are presented. This detector technology evolved from the development of Si strip detectors at the Finnish Research Institute for High Energy Physics (SEFT) which later merged with other physics research units to form the Helsinki Institute of Physics (HIP). General issues of X-ray imaging such as the benefits of the method of direct conversion of X-rays to signal charge in comparison to the indirect method and the pros and cons of photon counting vs. charge integration are discussed. A novel design of Si and CdTe pixel detectors and the analysis of their imaging performance in terms of SNR, MTF, DQE and dynamic range are presented in detail. The analysis shows that directly converting crystalline semiconductor pixel detectors operated in the charge integration mode can be used in X-ray imaging very close to the theoretical performance limits in terms of efficiency and resolution. Examples of the application of the developed imaging technology to dental intra oral and panoramic and to real time X-ray imaging are given. A CdTe photon counting gamma imager is introduced. A physical model to calculate the photo peak efficiency of photon counting CdTe pixel detectors is developed and described in detail. Simulation results indicates that the charge sharing phenomenon due to diffusion of signal charge carriers limits the pixel size of photon counting detectors to about 250 μm. Radiation hardness issues related to gamma and X-ray imaging detectors are discussed.