924 resultados para Storage reservoir
Resumo:
Audit report on the Iowa Petroleum Underground Storage Tank Board (UST Board) for the year ended June 30, 2009
Resumo:
Erythrocyte concentrates (ECs) are the major labile blood product being transfused worldwide, aiming at curing anemia of diverse origins. In Switzerland, ECs are stored at 4 °C up to 42 days in saline-adenine-glucose-mannitol (SAGM). Such storage induces cellular lesions, altering red blood cells (RBCs) metabolism, protein content and rheological properties. A hot debate exists regarding the impact of the storage lesions, thus the age of ECs on transfusion-related clinical adverse outcomes. Several studies tend to show that poorer outcomes occur in patients receiving older blood products. However, no clear association was demonstrated up to date. While metabolism and early rheological changes are reversible through transfusion of the blood units, oxidized proteins cannot be repaired, and it is likely such irreversible damages would affect the quality of the blood product and the efficiency of the transfusion. In vivo, RBCs are constantly exposed to oxygen fluxes, and are thus well equipped to deal with oxidative challenges. Moreover, functional 20S proteasome complexes allow for recognition and proteolysis of fairly oxidized protein, and some proteins can be eliminated from RBCs by the release of microvesicles. The present PhD thesis is involved in a global research project which goal is to characterize the effect of processing and storage on the quality of ECs. Assessing protein oxidative damages during RBC storage is of major importance to understand the mechanisms of aging of stored RBCs. To this purpose, redox proteomic-based investigations were conducted here. In a first part, cysteine oxidation and protein carbonylation were addressed via 2D-DIGE and derivatization-driven immunodetection approaches, respectively. Then, the oxidized sub- proteomes were characterized through LC-MS/MS identification of proteins in spots of interest (cysteine oxidation) or affinity-purified carbonylated proteins. Gene ontology annotation allowed classifying targets of oxidation according to their molecular functions. In a third part, the P20S activity was evaluated throughout the storage period of ECs, and its susceptibility to highly oxidized environment was investigated. The potential defensive role of microvesiculation was also addressed through the quantification of eliminated carbonylated proteins. We highlighted distinct protein groups differentially affected by cysteine oxidation, either reversibly or irreversibly. In addition, soluble extracts showed a decrease in carbonylation at the beginning of the storage and membrane extracts revealed increasing carbonylation after 4 weeks of storage. Engaged molecular functions revealed that antioxidant (AO) are rather reversibly oxidized at their cysteine residue(s), but are irreversibly oxidized through carbonylation. In the meantime, the 20S proteasome activity is decreased by around 40 % at the end of the storage period. Incubation of fresh RBCs extracts with exogenous oxidized proteins showed a dose-dependent and protein-dependent inhibitory effect. Finally, we proved that the release of microvesicles allows the elimination of increasing quantities of carbonylated proteins. Taken together, these results revealed an oxidative pathway model of RBCs storage, on which further investigation towards improved storage conditions will be based. -- Les concentrés érythrocytaires (CE) sont le produit sanguin le plus délivré au monde, permettant de traiter différentes formes d'anémies. En Suisse, les CE sont stocké à 4 °C pendant 42 jours dans une solution saline d'adénine, glucose et mannitol (SAGM). Une telle conservation induit des lésions de stockage qui altèrent le métabolisme, les protéines et les propriétés rhéologique du globule rouge (GR). Un débat important concerne l'impact du temps de stockage des CE sur les risques de réaction transfusionnelles, certaines études tentant de démontrer que des transfusions de sang vieux réduiraient l'espérance de vie des patients. Cependant, aucune association concrète n'a été prouvée à ce jour. Alors que les modifications du métabolisme et changement précoces des propriétés rhéologiques sont réversibles suite à la transfusion du CE, les protéines oxydées ne peuvent être réparées, et il est probable que de telles lésions affectent la qualité et l'efficacité des produits sanguins. In vivo, les GR sont constamment exposés à l'oxygène, et sont donc bien équipés pour résister aux lésions oxydatives. De plus, les complexes fonctionnels de proteasome 20S reconnaissent et dégradent les protéines modérément oxydées, et certaines protéines peuvent être éliminées par les microparticules. Cette thèse de doctorat est imbriquée dans un projet de recherche global ayant pour objectif la caractérisation des effets de la préparation et du stockage sur la qualité des GR. Evaluer les dommages oxydatifs du GR pendant le stockage est primordial pour comprendre les mécanismes de vieillissement des produits sanguin. Dans ce but, des recherches orientées redoxomique ont été conduites. Dans une première partie, l'oxydation des cystéines et la carbonylation des protéines sont évaluées par électrophorèse bidimensionnelle différentielle et par immunodétection de protéines dérivatisées. Ensuite, les protéines d'intérêt ainsi que les protéines carbonylées, purifiées par affinité, sont identifiées par spectrométrie de masse en tandem. Les protéines cibles de l'oxydation sont classées selon leur fonction moléculaire. Dans une troisième partie, l'activité protéolytique du protéasome 20S est suivie durant la période de stockage. L'impact du stress oxydant sur cette activité a été évalué en utilisant des protéines exogènes oxydées in vitro. Le potentiel rôle défensif de la microvesiculation a également été étudié par la quantification des protéines carbonylées éliminées. Dans ce travail, nous avons observé que différents groupes de protéines sont affectés par l'oxydation réversible ou irréversible de leurs cystéines. De plus, une diminution de la carbonylation en début de stockage dans les extraits solubles et une augmentation de la carbonylation après 4 semaines dans les extraits membranaires ont été montrées. Les fonctions moléculaires engagées par les protéines altérées montrent que les défenses antioxydantes sont oxydées de façon réversible sur leurs résidus cystéines, mais sont également irréversiblement carbonylées. Pendant ce temps, l'activité protéolytique du protéasome 20S décroit de 40 % en fin de stockage. L'incubation d'extraits de GR en début de stockage avec des protéines oxydées exogènes montre un effet inhibiteur « dose-dépendant » et « protéine-dépendant ». Enfin, les microvésicules s'avèrent éliminer des quantités croissantes de protéines carbonylées. La synthèse de ces résultats permet de modéliser une voie oxydative du stockage des GRs, à partir de laquelle de futures recherches seront menées avec pour but l'amélioration des conditions de stockage.
Resumo:
In this work, we demonstrate that conductive atomic force microscopy (C-AFM) is a very powerful tool to investigate, at the nanoscale, metal-oxide-semiconductor structures with silicon nanocrystals (Si-nc) embedded in the gate oxide as memory devices. The high lateral resolution of this technique allows us to study extremely small areas ( ~ 300nm2) and, therefore, the electrical properties of a reduced number of Si-nc. C-AFM experiments have demonstrated that Si-nc enhance the gate oxide electrical conduction due to trap-assisted tunneling. On the other hand, Si-nc can act as trapping centers. The amount of charge stored in Si-nc has been estimated through the change induced in the barrier height measured from the I-V characteristics. The results show that only ~ 20% of the Si-nc are charged, demonstrating that the electrical behavior at the nanoscale is consistent with the macroscopic characterization.
Resumo:
Audit report on the Iowa Petroleum Underground Storage Tank Board (UST Board) for the year ended June 30, 2010
Resumo:
Lihasikojen E-vitamiinin tarve ruokittaessa vastapuidulla ohralla ja rehuun lisätyn E-vitamiinin vaikutus lihan pakastussäilyvyyteen ja syöntilaatuun
Resumo:
In the subtropical regions of southern Brazil, rainfall distribution is uneven, which results in temporal variability of soil water storage. For grapes, water is generally available in excess and water deficiency occurs only occasionally. Furthermore, on the Southern Plateau of Santa Catarina, there are differences in soil properties, which results in high spatial variability. These two factors affect the composition of wine grapes. Spatio-temporal analyses are therefore useful in the selection of cultural practices as well as of adequate soils for vineyards. In this way, well-suited areas can produce grapes with a more appropriate composition for the production of quality wines. The aim of this study was to evaluate the spatio-temporal variability of water storage in a Cambisol during the growth cycle of a Cabernet Sauvignon vineyard and its relation to selected soil properties. The experimental area consisted of a commercial 8-year-old vineyard in São Joaquim, Santa Catarina, Brazil. A sampling grid with five rows and seven points per row, spaced 12 m apart, was outlined on an area of 3,456 m². Soil samples were collected with an auger at these points, 0.30 m away from the grapevines, in the 0.00-0.30 m layer, to determine gravimetric soil moisture. Measurements were taken once a week from December 2008 to April 2009, and every two weeks from December 2009 to March 2010. In December 2008, undisturbed soil samples were collected to determine bulk density, macro- and microporosity, and disturbed samples were used to quantify particle size distribution and organic carbon content. Results were subjected to descriptive analysis and semivariogram analysis, calculating the mean relative difference and the Pearson correlation. The average water storage in a Cambisol under grapevine on ridges had variable spatial dependence, i.e., the lower the average water storage, the higher the range of spatial dependence. Water storage had a stable spatial pattern during the trial period, indicating that the points with lower water storage or points with higher water storage during a certain period maintain these conditions throughout the experimental period. The relative difference is a simple method to identify positions that represent the average soil water storage more adequately at any time for a given area.
Resumo:
The multiscale finite-volume (MSFV) method is designed to reduce the computational cost of elliptic and parabolic problems with highly heterogeneous anisotropic coefficients. The reduction is achieved by splitting the original global problem into a set of local problems (with approximate local boundary conditions) coupled by a coarse global problem. It has been shown recently that the numerical errors in MSFV results can be reduced systematically with an iterative procedure that provides a conservative velocity field after any iteration step. The iterative MSFV (i-MSFV) method can be obtained with an improved (smoothed) multiscale solution to enhance the localization conditions, with a Krylov subspace method [e.g., the generalized-minimal-residual (GMRES) algorithm] preconditioned by the MSFV system, or with a combination of both. In a multiphase-flow system, a balance between accuracy and computational efficiency should be achieved by finding a minimum number of i-MSFV iterations (on pressure), which is necessary to achieve the desired accuracy in the saturation solution. In this work, we extend the i-MSFV method to sequential implicit simulation of time-dependent problems. To control the error of the coupled saturation/pressure system, we analyze the transport error caused by an approximate velocity field. We then propose an error-control strategy on the basis of the residual of the pressure equation. At the beginning of simulation, the pressure solution is iterated until a specified accuracy is achieved. To minimize the number of iterations in a multiphase-flow problem, the solution at the previous timestep is used to improve the localization assumption at the current timestep. Additional iterations are used only when the residual becomes larger than a specified threshold value. Numerical results show that only a few iterations on average are necessary to improve the MSFV results significantly, even for very challenging problems. Therefore, the proposed adaptive strategy yields efficient and accurate simulation of multiphase flow in heterogeneous porous media.
Resumo:
A recent method used to optimize biased neural networks with low levels of activity is applied to a hierarchical model. As a consequence, the performance of the system is strongly enhanced. The steps to achieve optimization are analyzed in detail.
Resumo:
Following a high wind event on January 24, 2006, at least five people claimed to have seen or felt the superstructure of the Saylorville Reservoir Bridge in central Iowa moving both vertically and laterally. Since that time, the Iowa Department of Transportation (DOT) contracted with the Bridge Engineering Center at Iowa State University to design and install a monitoring system capable of providing notification of the occurrence of subsequent high wind events. In subsequent years, a similar system was installed on the Red Rock Reservoir Bridge to provide the same wind monitoring capabilities and notifications to the Iowa DOT. The objectives of the system development and implementation are to notify personnel when the wind speed reaches a predetermined threshold such that the bridge can be closed for the safety of the public, correlate structural response with wind-induced response, and gather historical wind data at these structures for future assessments. This report describes the two monitoring systems, their components, upgrades, functionality, and limitations, and results from one year of wind data collection at both bridges.
Resumo:
Following high winds on January 24, 2006, at least five people claimed to have seen or felt the superstructure of the Saylorville Reservoir Bridge in central Iowa moving both vertically and laterally. Since that time, the Iowa Department of Transportation (DOT) contracted with the Bridge Engineering Center at Iowa State University to design and install a monitoring system capable of providing notification of the occurrence of subsequent high winds. Although measures were put into place following the 2006 event at the Saylorville Reservoir Bridge, knowledge of the performance of this bridge during high wind events was incomplete. Therefore, the Saylorville Reservoir Bridge was outfitted with an information management system to investigate the structural performance of the structure and the potential for safety risks. In subsequent years, given the similarities between the Saylorville and Red Rock Reservoir bridges, a similar system was added to the Red Rock Reservoir Bridge southeast of Des Moines. The monitoring system developed and installed on these two bridges was designed to monitor the wind speed and direction at the bridge and, via a cellular modem, send a text message to Iowa DOT staff when wind speeds meet a predetermined threshold. The original intent was that, once the text message is received, the bridge entrances would be closed until wind speeds diminish to safe levels.
Resumo:
Profiles of carbon isotopes were studied in marine limestones of Late Permian and Early Triassic age of the Tethyan region from 20 sections in Yugoslavia, Greece, Turkey, Armenian SSR, Iran, Pakistan, India, Nepal, and China. The Upper Permian sections continue the high positive values of 13C previously found in Upper Permian basins in NW Europe and western USA. In the more complete sections of Tethys it can now be demonstrated that the values of 13C drop from the Murgabian to the Dzhulfian Stages of the Upper Permian, then sharply to values near zero during the last two biozones of the Dorashamian. These levels of 13C sample the Tethys Sea and the world ocean, and equal values from deep-water sediments at Salamis Greece indicate that they apply to the whole water column. We hypothesize that the high values of 13C are a consequence of Late Paleozoic storage of organic carbon, and that the declines represent an episodic cessation of this organic deposition, and partial oxidation of the organic reservoir, extending over a period of several million years. The carbon isotope profile may reflect parallel complexity in the pattern of mass extinction in Late Permian time. Des profils isotopiques du carbone ont été établis dans des calcaires marins d'âge tardi-permien à éo-triasique répartis dans 20 endroits du domaine téthysien: Yougoslavie, Grèce, Turquie, République d'Arménie, Iran, Pakistan, Inde, Népal et Chine. Les profils établis dans le Permien supérieur montrent les mêmes valeurs positives de 13C observées antérieurement dans des bassins de même âge en Europe occidentale et dans l'ouest des USA. Dans les profils les plus complets de la Téthys, il est maintenant établi que les valeurs de 13C décroissent depuis le Murgabien jusqu'au Dzhulfien (Permien supérieur) pour devenir proches de zéro dans les deux dernières biozones du Dorasharmen. Ces valeurs de 13C sont caractéristiques de la Téthys et de l'Océan mondial; elles s'appliquent à toutes les profondeurs d'eau, comme en témoignent les valeurs fournies par des sédiments de mer profonde à Salamis (Grèce). Nous formulons l'hypothèse que les hautes valeurs de 13C sont la conséquence du stockage du carbone organique au Paléozoïque supérieur et que leur décroissance traduit un arrêt épisodique de cette sédimentation organique, accompagné d'une oxydation partielle de la matière organique s'étendant sur une période de plusieurs Ma. L'influence parallèle des phénomènes d'extinction massive à le fin du Permien se refléterait également dans les profils isotopiques du carbone.
Resumo:
River regulation for the purposes of public water supply causes the flow regime downstream of a dam to change. Traditionally, in the UK, such regulation was accompanied by requirements for reservoir releases to compensate downstream water users (e.g. industry) for the loss of natural flow (compensation flows). In this article, we compare a unique pre-impoundment macroinvertebrate data set for a regulated upland river with survey data post-impoundment. This allows a longitudinal assessment of the response of the system to regulation. The Derwent River, Northumberland, was impounded in 1966. Impacts on the hydrological regime were quantified by comparing long-term hydrographs, flow duration curves, flow ranges and flashiness indices for the pre-impoundment and post-impoundment periods. The comparison of changes in macroinvertebrate richness and diversity post-impoundment showed that the change in flow regime has had limited effect on the ecological community structure. The flow regime of the Derwent River has become less flashy with fewer extreme events, and the richness and the diversity of macroinvertebrates have, in some cases, increased and at worst have not deteriorated. We suggest that this reflects the strict compensation regime, which has guaranteed minimum flows at all times. Copyright (c) 2012 John Wiley & Sons, Ltd.
Resumo:
Audit report on the Iowa Petroleum Underground Storage Tank Board for the year ended June 30, 2011
Resumo:
Audit report on the Iowa Petroleum Underground Storage Tank Board for the year ended June 30, 2012