1000 resultados para RESONANCE INTEGRAL
Resumo:
Magdeburg, Univ., Fak. für Elektrotechnik und Informationstechnik, Diss., 2015
Resumo:
Os AA. apresentam dois casos de Osteomilite crônica submetidos durante anos a diversos tratamentos, sem resultado. Pela associação da assepsia integral com a Penicilina intra-arterial (via ainda não usada), conseguiram a cura após sutura primitiva num caso e secundária no outro. Por serem fátos excepcionais acham que devem ficar registrado.
Resumo:
El recurs als professionals sanitaris es sols una part de totes aquelles iniciatives, actuacions o creences que els nostres avantpassats van desenvolupar per conservar o millorar la salut, prevenir la malaltia o recuperar la salut. El recurs a altres tipus d'instàncies assistencials o terapèutiques, que es coneix com "pluralisme assistencial", sol ser la norma més que l'excepció. Per a enfocar adequadament aquest problema, cal centrar la indagació històrica sobre aquells -les persones malaltes o sanes- que volien i buscaven la salut. Aquests tipus d'acostaments pretenen tenir en compte totes les possibilitats a les quals es va recórrer en el passat per tal d'afrontar els problemes de salut.
Resumo:
"Vegeu el resum a l'inici del fitxer adjunt."
La Accesibilidad universal en los municipios: guía para una política integral de promoción y gestión
Resumo:
Conscientes de las complejidades que presenta la organización administrativa local y la diversidad que caracteriza a los Ayuntamientos de España, y lejos de querer establecer fórmulas mágicas o generalizar soluciones, con esta Guía se pretende aportar ideas útiles mediante propuestas y algunos ejemplos; con ella se quiere ayudar a promover distintas intervenciones a favor de la accesibilidad en los municipios. En este sentido, esta Guía pretende ser soporte para desarrollar una nueva etapa de intervención municipal en accesibilidad, que vaya más allá de la mera supresión de barreras y se prevenga su creación. Las medidas que se desarrollan son posibles vías para que los gobiernos locales puedan gestionar y promocionar de forma eficaz la accesibilidad en el municipio y así establecer una base sobre la cual todos los ciudadanos puedan desarrollar sus libertades individuales plenamente.
Resumo:
Este Libro Verde pretende difundir, compartir y discutir públicamente la situación de la accesibilidad en España, así como los instrumentos y políticas puestos en marcha en los últimos años para su promoción y las necesarias reformas o iniciativas para avanzar en el proceso de supresión de todo tipo de barreras –arquitectónicas, urbanísticas, en el transporte, la comunicación e información, etc.– en nuestro país.
Resumo:
Des de la ciència geogràfica combinada amb el coneixement biològic i comercial, aquest projecte pretén crear una eina basada en la biogeografia i les últimes tecnologies de la Informació Geogràfica, que permetrà a l’usuari disposar de informació actualitzada per cada espècie amb interès comercial. El projecte es basa en el desenvolupament d’una aplicació web de consulta, entrada i actualització de dades referents a la producció pesquera internacional. Les eines utilitzades són les bases de dades MySQL i PostgreSQL i programació web amb html, php i javacript. Aquesta aplicació està pensada per ser accessible des de qualsevol ordinador amb connexió a internet i es subdivideix en tres sub-aplicacions. La primera sub-aplicació es basa en l’entrada d’espècies a partir de l’estructura taxonòmica. Partint de l’arbre taxonòmic, l’usuari té la possibilitat d’entrar, eliminar o modificar qualsevol tàxon o espècie. La segona subaplicació és una eina de digitalització cartogràfica on-line on l’usuari podrà marcar, eliminar o modificar sobre un mapa les localitzacions de les espècies que estiguin entrades en la sub-aplicació anterior. Finalment, la tercera sub-aplicació és una eina d’entrada de dades quinzenals referent als comportaments pel que fa tan a les dimensions com a les disponibilitats de pesca per cada espècie i localització.
Resumo:
OBJECTIVE-We studied whether manganese-enhanced high-field magnetic resonance (MR) imaging (MEHFMRI) could quantitatively detect individual islets in situ and in vivo and evaluate changes in a model of experimental diabetes.RESEARCH DESIGN AND METHODS-Whole pancreata from untreated (n = 3), MnCl(2) and glucose-injected mice (n = 6), and mice injected with either streptozotocin (STZ; n = 4) or citrate buffer (n = 4) were imaged ex vivo for unambiguous evaluation of islets. Exteriorized pancreata of MnCl(2) and glucose-injected mice (n = 6) were imaged in vivo to directly visualize the gland and minimize movements. In all cases, MR images were acquired in a 14.1 Testa scanner and correlated with the corresponding (immuno)histological sections.RESULTS-In ex vivo experiments, MEHFMRI distinguished different pancreatic tissues and evaluated the relative abundance of islets in the pancreata of normoglycemic mice. MEHFMRI also detected a significant decrease in the numerical and volume density of islets in STZ-injected mice. However, in the latter measurements the loss of beta-cells was undervalued under the conditions tested. The experiments on the externalized pancreata confirmed that MEHFMRI could visualize native individual islets in living, anesthetized mice.CONCLUSIONS-Data show that MEHFMRI quantitatively visualizes individual islets in the intact mouse pancreas, both ex vivo and in vivo. Diabetes 60:2853-2860, 2011
Resumo:
In this paper we introduce new functional spaces which we call the net spaces. Using their properties, the necessary and sufficient conditions for the integral operators to be of strong or weak-type are obtained. The estimates of the norm of the convolution operator in weighted Lebesgue spaces are presented.
Resumo:
OBJECTIVE: Contemporary free-breathing non contrast enhanced cardiovascular magnetic resonance angiography (CMRA) was qualitatively and quantitatively evaluated to ascertain the reproducibility of the method for coronary artery luminal dimension measurements. SUBJECTS AND METHODS: Twenty-two healthy volunteers (mean age 32 +/- 7 years, 12 males) without coronary artery disease were imaged at 2 centers (1 each in Europe and North America) using navigator-gated and corrected SSFP CMRA on a commercial whole body 1.5T System. Repeat images of right (RCA, n = 21), left anterior descending (LAD, n = 14) and left circumflex (LCX, n = 14) coronary arteries were obtained in separate sessions using identical scan protocol and imaging parameters. True visible vessel length, signal-to-noise (SNR), contrast-to-noise ratios (CNR) and the average luminal diameter over the first 4 cm of the vessel were measured. Intra-observer, inter-observer and inter-scan reproducibility of coronary artery luminal diameter were determined using Pearson's correlation, Bland-Altman analysis and intraclass correlation coefficients (ICC). RESULTS: CNR, SNR and the mean length of the RCA, LAD and LCX imaged for original and repeat scans were not significantly different (all p > 0.30). There was a high degree of intra-observer, inter-observer and inter-scan agreements for RCA, LAD and LCX luminal diameter respectively on Bland-Altman and ICC analysis (ICC's for RCA: 0.98. 0.98 and 0.86; LAD: 0.89, 0.89 and 0.63; LCX: 0.95, 0.94 and 0.79). CONCLUSION: In a 2-center study, we demonstrate that free-breathing 3D SSFP CMRA can visualize long continuous segments of coronary vessels with highly reproducible measurements of luminal diameter.
Resumo:
AIMS: Bicuspid aortic valve (BAV) causes complex flow patterns in the ascending aorta (AAo), which may compromise the accuracy of flow measurement by phase-contrast magnetic resonance (PC-MR). Therefore, we aimed to assess and compare the accuracy of forward flow measurement in the AAo, where complex flow is more dominant in BAV patients, with flow quantification in the left ventricular outflow tract (LVOT) and the aortic valve orifice (AV), where complex flow is less important, in BAV patients and controls. METHODS AND RESULTS: Flow was measured by PC-MR in 22 BAV patients and 20 controls at the following positions: (i) LVOT, (ii) AV, and (iii) AAo, and compared with the left ventricular stroke volume (LVSV). The correlation between the LVSV and the forward flow in the LVOT, the AV, and the AAo was good in BAV patients (r = 0.97/0.96/0.93; P < 0.01) and controls (r = 0.96/0.93/0.93; P < 0.01). However, in relation with the LVSV, the forward flow in the AAo was mildly underestimated in controls and much more in BAV patients [median (inter-quartile range): 9% (4%/15%) vs. 22% (8%/30%); P < 0.01]. This was not the case in the LVOT and the AV. The severity of flow underestimation in the AAo was associated with flow eccentricity. CONCLUSION: Flow measurement in the AAo leads to an underestimation of the forward flow in BAV patients. Measurement in the LVOT or the AV, where complex flow is less prominent, is an alternative means for quantifying the systolic forward flow in BAV patients.
Resumo:
Nonstructural protein 4B (NS4B) plays an essential role in the formation of the hepatitis C virus (HCV) replication complex. It is a relatively poorly characterized integral membrane protein predicted to comprise four transmembrane segments in its central portion. Here, we describe a novel determinant for membrane association represented by amino acids (aa) 40 to 69 in the N-terminal portion of NS4B. This segment was sufficient to target and tightly anchor the green fluorescent protein to cellular membranes, as assessed by fluorescence microscopy as well as membrane extraction and flotation analyses. Circular dichroism and nuclear magnetic resonance structural analyses showed that this segment comprises an amphipathic alpha-helix extending from aa 42 to 66. Attenuated total reflection infrared spectroscopy and glycosylation acceptor site tagging revealed that this amphipathic alpha-helix has the potential to traverse the phospholipid bilayer as a transmembrane segment, likely upon oligomerization. Alanine substitution of the fully conserved aromatic residues on the hydrophobic helix side abrogated membrane association of the segment comprising aa 40 to 69 and disrupted the formation of a functional replication complex. These results provide the first atomic resolution structure of an essential membrane-associated determinant of HCV NS4B.
Resumo:
"Vegeu el resum a l'inici del document del fitxer adjunt."
Resumo:
PURPOSE: To evaluate the feasibility of visualizing the stent lumen using coronary magnetic resonance angiography in vitro. MATERIAL AND METHODS: Nineteen different coronary stents were implanted in plastic tubes with an inner diameter of 3 mm. The tubes were positioned in a plastic container filled with gel and included in a closed flow circuit (constant flow 18 cm/sec). The magnetic resonance images were obtained with a dual inversion fast spin-echo sequence. For intraluminal stent imaging, subtraction images were calculated from scans with and without flow. Subsequently, intraluminal signal properties were objectively assessed and compared. RESULTS: As a function of the stent type, various degrees of in-stent signal attenuation were observed. Tantalum stents demonstrated minimal intraluminal signal attenuation. For nitinol stents, the stent lumen could be identified, but the intraluminal signal was markedly reduced. Steel stents resulted in the most pronounced intraluminal signal voids. CONCLUSIONS: With the present technique, radiofrequency penetration into the stents is strongly influenced by the stent material. Thesefindings may have important implicationsforfuture stent design and stent imaging strategies.