694 resultados para Percutaneous


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND REG1 is a novel anticoagulation system consisting of pegnivacogin, an RNA aptamer inhibitor of coagulation factor IXa, and anivamersen, a complementary sequence reversal oligonucleotide. We tested the hypothesis that near complete inhibition of factor IXa with pegnivacogin during percutaneous coronary intervention, followed by partial reversal with anivamersen, would reduce ischaemic events compared with bivalirudin, without increasing bleeding. METHODS We did a randomised, open-label, active-controlled, multicentre, superiority trial to compare REG1 with bivalirudin at 225 hospitals in North America and Europe. We planned to randomly allocate 13,200 patients undergoing percutaneous coronary intervention in a 1:1 ratio to either REG1 (pegnivacogin 1 mg/kg bolus [>99% factor IXa inhibition] followed by 80% reversal with anivamersen after percutaneous coronary intervention) or bivalirudin. Exclusion criteria included ST segment elevation myocardial infarction within 48 h. The primary efficacy endpoint was the composite of all-cause death, myocardial infarction, stroke, and unplanned target lesion revascularisation by day 3 after randomisation. The principal safety endpoint was major bleeding. Analysis was by intention to treat. This trial is registered at ClinicalTrials.gov, identifier NCT01848106. The trial was terminated early after enrolment of 3232 patients due to severe allergic reactions. FINDINGS 1616 patients were allocated REG1 and 1616 were assigned bivalirudin, of whom 1605 and 1601 patients, respectively, received the assigned treatment. Severe allergic reactions were reported in ten (1%) of 1605 patients receiving REG1 versus one (<1%) of 1601 patients treated with bivalirudin. The composite primary endpoint did not differ between groups, with 108 (7%) of 1616 patients assigned REG1 and 103 (6%) of 1616 allocated bivalirudin reporting a primary endpoint event (odds ratio [OR] 1·05, 95% CI 0·80-1·39; p=0·72). Major bleeding was similar between treatment groups (seven [<1%] of 1605 receiving REG1 vs two [<1%] of 1601 treated with bivalirudin; OR 3·49, 95% CI 0·73-16·82; p=0·10), but major or minor bleeding was increased with REG1 (104 [6%] vs 65 [4%]; 1·64, 1·19-2·25; p=0·002). INTERPRETATION The reversible factor IXa inhibitor REG1, as currently formulated, is associated with severe allergic reactions. Although statistical power was limited because of early termination, there was no evidence that REG1 reduced ischaemic events or bleeding compared with bivalirudin. FUNDING Regado Biosciences Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND No data are available on the long-term performance of ultrathin strut biodegradable polymer sirolimus-eluting stents (BP-SES). We reported 2-year clinical outcomes of the BIOSCIENCE (Ultrathin Strut Biodegradable Polymer Sirolimus-Eluting Stent Versus Durable Polymer Everolimus-Eluting Stent for Percutaneous Coronary Revascularisation) trial, which compared BP-SES with durable-polymer everolimus-eluting stents (DP-EES) in patients undergoing percutaneous coronary intervention. METHODS AND RESULTS A total of 2119 patients with minimal exclusion criteria were assigned to treatment with BP-SES (n=1063) or DP-EES (n=1056). Follow-up at 2 years was available for 2048 patients (97%). The primary end point was target-lesion failure, a composite of cardiac death, target-vessel myocardial infarction, or clinically indicated target-lesion revascularization. At 2 years, target-lesion failure occurred in 107 patients (10.5%) in the BP-SES arm and 107 patients (10.4%) in the DP-EES arm (risk ratio [RR] 1.00, 95% CI 0.77-1.31, P=0.979). There were no significant differences between BP-SES and DP-EES with respect to cardiac death (RR 1.01, 95% CI 0.62-1.63, P=0.984), target-vessel myocardial infarction (RR 0.91, 95% CI 0.60-1.39, P=0.669), target-lesion revascularization (RR 1.17, 95% CI 0.81-1.71, P=0.403), and definite stent thrombosis (RR 1.38, 95% CI 0.56-3.44, P=0.485). There were 2 cases (0.2%) of definite very late stent thrombosis in the BP-SES arm and 4 cases (0.4%) in the DP-EES arm (P=0.423). In the prespecified subgroup of patients with ST-segment elevation myocardial infarction, BP-SES was associated with a lower risk of target-lesion failure compared with DP-EES (RR 0.48, 95% CI 0.23-0.99, P=0.043, Pinteraction=0.026). CONCLUSIONS Comparable safety and efficacy profiles of BP-SES and DP-EES were maintained throughout 2 years of follow-up. CLINICAL TRIAL REGISTRATION URL: https://www.clinicaltrials.gov. Unique identifier: NCT01443104.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Peripheral arteriovenous malformations (AVM) remain most challenging among various congenital vascular malformations to be treated. Here we present three illustrative patients with Yakes type IIIb and type IV AVM at the plantar aspect of the foot who were successfully treated by minimally invasive embolization. The value of the Yakes AVM classification system to guide the therapeutic decision making by directing specific therapeutic procedures to specific AVM types defined by their angioarchitecture is demonstrated. Direct percutaneous AVM puncture with coiling of aneurysmal outflow vein and subsequent ethanol embolization is shown. Finally, the report illustrates that several AVM types can coexist.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Cardiac troponin detected by new-generation, highly sensitive assays predicts clinical outcomes among patients with stable coronary artery disease (SCAD) treated medically. The prognostic value of baseline high-sensitivity cardiac troponin T (hs-cTnT) elevation in SCAD patients undergoing elective percutaneous coronary interventions is not well established. This study assessed the association of preprocedural levels of hs-cTnT with 1-year clinical outcomes among SCAD patients undergoing percutaneous coronary intervention. METHODS AND RESULTS Between 2010 and 2014, 6974 consecutive patients were prospectively enrolled in the Bern Percutaneous Coronary Interventions Registry. Among patients with SCAD (n=2029), 527 (26%) had elevated preprocedural hs-cTnT above the upper reference limit of 14 ng/L. The primary end point, mortality within 1 year, occurred in 20 patients (1.4%) with normal hs-cTnT versus 39 patients (7.7%) with elevated baseline hs-cTnT (P<0.001). Patients with elevated hs-cTnT had increased risks of all-cause (hazard ratio 5.73; 95% confidence intervals 3.34-9.83; P<0.001) and cardiac mortality (hazard ratio 4.68; 95% confidence interval 2.12-10.31; P<0.001). Preprocedural hs-TnT elevation remained an independent predictor of 1-year mortality after adjustment for relevant risk factors, including age, sex, and renal failure (adjusted hazard ratio 2.08; 95% confidence interval 1.10-3.92; P=0.024). A graded mortality risk was observed across higher tertiles of elevated preprocedural hs-cTnT, but not among patients with hs-cTnT below the upper reference limit. CONCLUSIONS Preprocedural elevation of hs-cTnT is observed in one fourth of SCAD patients undergoing elective percutaneous coronary intervention. Increased levels of preprocedural hs-cTnT are proportionally related to the risk of death and emerged as independent predictors of all-cause mortality within 1 year. CLINICAL TRIAL REGISTRATION URL: http://www.clinicaltrials.gov. Unique identifier: NCT02241291.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The relationship between change in myocardial infarction (MI) mortality rate (ICD codes 410, 411) and change in use of percutaneous transluminal coronary angioplasty (PTCA), adjusted for change in hospitalization rates for MI, and for change in use of aortocoronary bypass surgery (ACBS) from 1985 through 1990 at private hospitals was examined in the biethnic community of Nueces County, Texas, site of the Corpus Christi Heart Project, a major coronary heart disease (CHD) surveillance program. Age-adjusted rates (per 100,000 persons) were calculated for each of these CHD events for the population aged 25 through 74 years and for each of the four major sex-ethnic groups: Mexican-American and Non-Hispanic White women and men. Over this six year period, there were 541 MI deaths, 2358 MI hospitalizations, 816 PTCA hospitalizations, and 920 ACBS hospitalizations among Mexican-American and Non-Hispanic White Nueces County residents. Acute MI mortality decreased from 24.7 in the first quarter of 1985 to 12.1 in the fourth quarter of 1990, a 51.2% decrease. All three hospitalization rates increased: The MI hospitalization rates increased from 44.1 to 61.3, a 38.9% increase, PTCA use increased from 7.1 to 23.2, a 228.0% increase, and ACBS use increased from 18.8 to 29.5, a 56.6% increase. In linear regression analyses, the change in MI mortality rate was negatively associated with the change in PTCA use (beta = $-$.266 $\pm$.103, p = 0.017) but was not associated with the changes in MI hospitalization rate and in ACBS use. The results of this ecologic research support the idea that the increasing use of PTCA, but not ACBS, has been associated with decreases in MI mortality. The contrast in associations between these two revascularization procedures and MI mortality highlights the need for research aimed at clarifying the proper roles of these procedures in the treatment of patients with CHD. The association between change in PTCA use and change in MI mortality supports the idea that some changes in medical treatment may be partially responsible for trends in CHD mortality. Differences in the use of therapies such as PTCA may be related to differences between geographical sites in CHD rates and trends. ^

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES We sought to assess the safety and efficacy of percutaneous closure of atrial septal defects (ASDs) under fluoroscopic guidance only, without periprocedural echocardiographic guidance. BACKGROUND Percutaneous closure of ASDs is usually performed using simultaneous fluoroscopic and transthoracic, transesophageal (TEE), or intracardiac echocardiographic (ICE) guidance. However, TEE requires deep sedation or general anesthesia, which considerably lengthens the procedure. TEE and ICE increase costs. METHODS Between 1997 and 2008, a total of 217 consecutive patients (age, 38 ± 22 years; 155 females and 62 males), of whom 44 were children ≤16 years, underwent percutaneous ASD closure with an Amplatzer ASD occluder (AASDO). TEE guidance and general anesthesia were restricted to the children, while devices were implanted under fluoroscopic guidance only in the adults. For comparison of technical safety and feasibility of the procedure without echocardiographic guidance, the children served as a control group. RESULTS The implantation procedure was successful in all but 3 patients (1 child and 2 adults; 1.4%). Mean device size was 23 ± 8 mm (range, 4-40 mm). There was 1 postprocedural complication (0.5%; transient perimyocarditis in an adult patient). At last echocardiographic follow-up, 13 ± 23 months after the procedure, 90% of patients had no residual shunt, whereas a minimal, moderate, or large shunt persisted in 7%, 1%, and 2%, respectively. Four adult patients (2%) underwent implantation of a second device for a residual shunt. During a mean follow-up period of 3 ± 2 years, 2 deaths and 1 ischemic stroke occurred. CONCLUSION According to these results, percutaneous ASD closure using the AASDO without periprocedural echocardiographic guidance seems safe and feasible.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

H-2Kb-restricted tumor epitope peptides, including tyrosinase-related protein 2 residues 181–188 (TRP-2) and connexin 37 residues 52–59 (MUT1), were applied to permeability barrier-disrupted C57BL/6 (B6) mouse skin from which the stratum corneum of the epidermis had been removed by tape-stripping. This procedure primed tumor-specific cytotoxic T lymphocytes (CTLs) in the lymph nodes and spleen, protected mice against subsequent challenge with corresponding tumor cells, and suppressed the growth of established tumors. Preventive and therapeutic effectiveness was correlated with the frequency of tumor-specific CTL precursors. MHC class II Iab+ cells separated from tape-stripped skin, compared with those from intact skin, exhibited a strong antigen-presenting capacity for CTL, suggesting that CTL expansion after peptide application is primarily mediated by epidermal Langerhans cells. Thus, percutaneous peptide immunization via barrier-disrupted skin provides a simple and noninvasive means of inducing potent anti-tumor immunity which may be exploited for cancer immunotherapy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This case report describes removal of a knotted, subclavian, pulmonary artery catheter using a tracheostomy dilator. With this simple method an invasive procedure might be averted.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

At head of title: Treasury department. Public health and marine-hospital service of the United States.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Stratum corneum (SC) desorption experiments have yielded higher calculated steady-state fluxes than those obtained by epidermal penetration studies. A possible explanation of this result is a variable diffusion or partition coefficient across the SC. We therefore developed the diffusion model for percutaneous penetration and desorption to study the effects of either a variable diffusion coefficient or variable partition coefficient in the SC over the diffusion path length. Steady-state flux, lag time, and mean desorption time were obtained from Laplace domain solutions. Numerical inversion of the Laplace domain solutions was used for simulations of solute concentration-distance and amount penetrated (desorbed)-time profiles. Diffusion and partition coefficients heterogeneity were examined using six different models. The effect of heterogeneity on predicted flux from desorption studies was compared with that obtained in permeation studies. Partition coefficient heterogeneity had a more profound effect on predicted fluxes than diffusion coefficient heterogeneity. Concentration-distance profiles show even larger dependence on heterogeneity, which is consistent with experimental tape-stripping data reported for clobetasol propionate and other solutes. The clobetasol propionate tape-stripping data were most consistent with the partition coefficient decreasing exponentially for half the SC and then becoming a constant for the remaining SC. (C) 2004 Wiley-Liss, Inc.