270 resultados para Pannelli solari fotovoltaici facciate ventilate
Resumo:
Samples for total organic carbon (TOC) analysis were collected on WOCE Line P15S (0° to 67°S along 170°W) and from 53° to 67°S along 170°E in the western South Pacific, and on Line I8 (5°N to 43°S along 80°/90°E) in the central Indian Ocean. TOC concentrations in the upper ocean varied greatly between the regions studied. Highest surface TOC concentrations (81-85 µM C and 68-73 µM C) were observed in the warmest waters (>27°C) of the western South Pacific and central Indian Oceans, respectively. Lowest surface TOC concentrations (45-65 µM C) were recorded in the southernmost waters occupied (>50°S along 170°W and 170°E). Deep water (>1000 m) TOC concentrations were uniform across all regions analyzed, averaging between 42.3 and 43 µM C (SD: ±0.9 µM C). Mixing between TOC-rich surface waters and TOC-poor deep waters was indicated by the strong correlations between TOC and temperature (r2>0.80, north of 45°S) and TOC and density (r2>0.50, southernmost regions). TOC was inversely correlated with apparent oxygen utilization (AOU) along isopycnal surfaces north of the Polar Frontal Zone (PFZ) and at depths <500 m. The TOC:AOU molar ratios at densities of sigmaT 23-27 ranged from -0.15 to -0.34 in the South Pacific and from -0.13 to -0.31 in the Indian Ocean. These ratios indicate that TOC oxidation was responsible for 21%-47% and 18%-43% of oxygen consumption in the upper South Pacific and Indian Oceans, respectively. At greater depths, TOC did not contribute to the development of AOU. There was no evidence for significant export of dissolved and suspended organic carbon along isopycnal surfaces that ventilate near the PFZ.
Resumo:
Hasta la fecha se han evaluado distintas técnicas de verificación y validación teórica y empíricamente. La mayoría de las evaluaciones empíricas se han llevado a cabo sin sujetos, abstrayendo el efecto del sujeto sobre la técnica a la hora de aplicarla. Hemos evaluado mediante un experimento con sujetos la efectividad de tres técnicas de verificación y validación de código: partición en clases de equivalencia, cobertura de decisión y lectura de código mediante abstracciones sucesivas, estudiando la capacidad de las técnicas para la detección de fallos en tres programas distintos. Hemos replicado el experimento ocho veces en cuatro entornos distintos. Los resultados arrojan diferencias entre las técnicas y señalan variables contextuales del proyecto software que deberían considerarse cuando se quiera elegir o aplicar una técnica de verificación y validación.
Resumo:
Se ha realizado un estudio sobre la microbiota fúngica asociada a la fumagina del madroño, determinándose las especies de pulgones recogidas sobre madroños muestreados en la Comunidad de Madrid (España). Las especies de pulgones del madroño encontradas en los muestreos han sido dos: Aphis arbuti Ferrari y Wahlgreniella nervata (Gillette). La especie más frecuente ha sido W. nervata cuya presencia se observó en el 80% de las muestras, mientras que A. arbuti estuvo presente en el 35% de ellas. Parecen ser especies bastante específicas del madroño, de las que no se habían recogido citas en la Comunidad de Madrid. Los análisis microbiológicos realizados sobre las hojas de madroño muestran que no existen diferencias apreciables entre las que visualmente tienen negrilla y pulgones de aquellas que están aparentemente normales. La microbiota fúngica total de las ramillas es muy semejante a la de las hojas. Sobresalen entre los géneros y/o especies Alternaria, Aspergillus, Niger, Aureobasidium, Cladosporium y Fusarium. Este último género representado por dos especies (F. dinerum y F. solari) no ha incrementado considerablemente su presencia cuando se ha utilizado un medio específico para el análisis.
Resumo:
Some verification and validation techniques have been evaluated both theoretically and empirically. Most empirical studies have been conducted without subjects, passing over any effect testers have when they apply the techniques. We have run an experiment with students to evaluate the effectiveness of three verification and validation techniques (equivalence partitioning, branch testing and code reading by stepwise abstraction). We have studied how well able the techniques are to reveal defects in three programs. We have replicated the experiment eight times at different sites. Our results show that equivalence partitioning and branch testing are equally effective and better than code reading by stepwise abstraction. The effectiveness of code reading by stepwise abstraction varies significantly from program to program. Finally, we have identified project contextual variables that should be considered when applying any verification and validation technique or to choose one particular technique.
Resumo:
Context: A replication is the repetition of an experiment. Several efforts have been made to adopt replication as a common practice in software engineering. There are different types of replications, depending on their purpose. Similar replications keep the experimental conditions as alike as possible to the original ones. External similar replications, where the replicating experimenters are not the same people as the original experimenters, have been a stumbling block. Several attempts at combining the results of replications have resulted in failure. Software engineering does not appear to be well suited to such replications, because it works with complex experimentally immature contexts. Software engineering settings have a large number of variables, and the role that many of them play is unknown. A successful (or useful) similar replication helps to better understand the phenomenon under study by verifying results and/or identifying contextual variables that could influence (or not) the results, through the combination of experimental results. Objective: To be able to get successful similar replications, there needs to be interaction between original and replicating experimenters. In this paper, we propose an interaction process for achieving successful similar replications. Method: This process consists of: an adaptation meeting, where experimenters tailor the experiment to the new setting; querying, to settle occasional inquiries while the experiment is being run; and a combination meeting, where experimenters meet to discuss the combination of replication outcomes with previous results. To check its effectiveness, the process has been tested on three different replications of the same experiment. Results: The proposed interaction process has helped to identify new contextual variables that could potentially influence (or not) the experimental results in the three replications run. Additionally, the interaction process has helped to uncover certain problems and deviations that occurred during some of the replications that we would have not been aware of otherwise. Conclusions: There are signs that suggest that it is possible to get successful similar replications in soft- ware engineering experimentation, when there is appropriate interaction among experimenters.
Resumo:
A finales del siglo XIX y principios del XX, la aparición de nuevos materiales, como el acero y el hormigón armado, y la experimentación en procedimientos industriales provocan un cambio en el concepto de cerramiento y en la forma de construir. La fachada se libera y se independiza de la estructura principal, y el nuevo cerramiento debe responder a los principios arquitectónicos y constructivos de este momento. Se busca, por tanto, un cerramiento nuevo. Un cerramiento ligero, de poco peso, de poco espesor, autoportante, multicapa, montado en seco, de grandes dimensiones y que cumpla las exigencias de todo cerramiento. Se puede afirmar que, hasta que Jean Prouvé experimenta con distintos materiales y sistemas de fabricación, la técnica de los cerramientos ligeros no se desarrolla por completo. En sus trabajos se pueden encontrar aplicaciones de los nuevos materiales y nuevas técnicas, e investigaciones sobre prefabricación ligera en acero y aluminio, en un intento de aplicar la producción industrial y en serie a la construcción. Esta Tesis realiza un análisis en profundidad, tanto gráfico como escrito, de los cerramientos verticales desarrollados por Jean Prouvé, sin tratarlos como objetos aislados, entendiendo que forman parte de una obra arquitectónica concreta y completa. Dicho análisis sirve para clasificarlos según las funciones esenciales que debe garantizar un cerramiento: aislar, iluminar, ventilar y proteger, y para comprender cuáles son las claves, los recursos e intenciones, utilizadas por el autor para conseguir este propósito. El resultado de la investigación se plasma de dos formas diferentes. En la primera, se realizan reflexiones críticas para extraer los temas importantes de los elementos analizados, lo que posibilita el acercamiento a otros arquitectos y ampliar el campo de visión. En la segunda, de tipo gráfico, se elabora un atlas de los distintos tipos de cerramientos verticales desarrollados por Jean Prouvé. ABSTRACT In the late nineteenth and the early twentieth century, the appearance of new materials, like steel or reinforced concrete, and the experimentation in industrial procedures cause a change in the concept of façade and in the way of build. The façade is released and become independent of the main structural frame, and the new building enclosure must answer the architectural and construction principles of that moment. A new façade is therefore looked for. A light, thin, self supported, multi layer, dry mounted and big dimensions façade that meet the exigencies of all building enclosure. You can ensure that until Jean Prouvé experiment with several materials and fabrication systems, the light façade technic does not develop completely. In his work we can find new materials applications and new technics and studies about light prefabrication with steel and aluminium, in an attempt of apply the mass production to construction. This Thesis carries out a deep analysis, graphic and written, of the vertical enclosure panels of Jean Prouvé’s work. This is made without studying them like isolated objects, but understanding that they are part of a particular architectural work, as a whole. The analysis is used for classify the panels according to main functions that a façade must satisfy: isolate, light up, ventilate and protect. And also to understand which are the keys, the resources and intentions used by Prouvé to achieve this goal. The result of the research is presented in two different ways. In the first one, a critical reflection is made in order to extract the important issues of the analyzed elements. That makes possible the approach to other architects and gives us a bigger range of vision. In the second, graphic, an atlas of the different types of vertical façade panels of Jean Prouvé is made.
Resumo:
Six new members of the yeast p24 family have been identified and characterized. These six genes, named ERP1–ERP6 (for Emp24p- and Erv25p-related proteins) are not essential, but deletion of ERP1 or ERP2 causes defects in the transport of Gas1p, in the retention of BiP, and deletion of ERP1 results in the suppression of a temperature-sensitive mutation in SEC13 encoding a COPII vesicle coat protein. These phenotypes are similar to those caused by deletion of EMP24 or ERV25, two previously identified genes that encode related p24 proteins. Genetic and biochemical studies demonstrate that Erp1p and Erp2p function in a heteromeric complex with Emp24p and Erv25p.
Resumo:
Excitatory amino acid toxicity, resulting from overactivation of N-methyl-D-aspartate (NMDA) glutamate receptors, is a major mechanism of neuronal cell death in acute and chronic neurological diseases. We have investigated whether excitotoxicity may occur in peripheral organs, causing tissue injury, and report that NMDA receptor activation in perfused, ventilated rat lungs triggered acute injury, marked by increased pressures needed to ventilate and perfuse the lung, and by high-permeability edema. The injury was prevented by competitive NMDA receptor antagonists or by channel-blocker MK-801, and was reduced in the presence of Mg2+. As with NMDA toxicity to central neurons, the lung injury was nitric oxide (NO) dependent: it required L-arginine, was associated with increased production of NO, and was attenuated by either of two NO synthase inhibitors. The neuropeptide vasoactive intestinal peptide and inhibitors of poly(ADP-ribose) polymerase also prevented this injury, but without inhibiting NO synthesis, both acting by inhibiting a toxic action of NO that is critical to tissue injury. The findings indicate that: (i) NMDA receptors exist in the lung (and probably elsewhere outside the central nervous system), (ii) excessive activation of these receptors may provoke acute edematous lung injury as seen in the "adult respiratory distress syndrome," and (iii) this injury can be modulated by blockade of one of three critical steps: NMDA receptor binding, inhibition of NO synthesis, or activation of poly(ADP-ribose) polymerase.
Resumo:
En esta comunicación se presentan los estudios previos y las intervenciones realizadas en la iglesia de San Sebastián de Orihuela, Alicante (España) con el fin de subsanar los problemas estructurales que presentaba, con múltiples grietas en arcos y bóvedas y eliminar la humedad presente en sus fábricas, además de las sales aportadas por el agua. En el estudio histórico y arquitectónico se ha comprobado que la iglesia se construyó sobre una ermita gótica y se finalizó en 1743 pero ha sufrido numerosas intervenciones. Es una iglesia de nave única con capillas laterales cubierta mediante bóvedas. Su fachada y las pilastras interiores son de piedra vista. Para el diagnóstico se han empleado diversas técnicas (ultrasonidos, higrómetro…) que han permitido deducir las causas de las lesiones. Las intervenciones se han dirigido a reforzar la estructura mediante cosidos e inyecciones, así como a ventilar la base mediante un forjado sanitario. También se ha saneado la piedra vista, tanto en interior como en fachada y se han sacado a la luz los arcos de piedra ocultos bajo un estucado. También se han restaurado los restos arqueológicos de época gótica.
Resumo:
L'evoluzione della tecnologia allo stato solido e il fiorire di nuove applicazioni determinano una forte spinta verso la miniaturizzazione dei convertitori elettronici di potenza. Questa riduzione di pesi ed ingombri è particolarmente sentita anche in quei convertitori di media potenza che necessitano di un trasformatore d'isolamento. In quest'ambito assume importante rilievo l'utilizzo di una architettura circuitale a ponte intero e di tecniche in grado di spingere la frequenza di commutazione il più in alto possibile. Questa tesi si propone quindi di studiare a fondo il funzionamento dei convertitori DC/DC isolati di tipo Full-Bridge e pilotati con la tecnica di modulazione Phase-Shifted che ben si presta all'impiego di commutazioni risonanti del tipo Zero-Voltage-Switching. L'analisi teorica sarà corroborata da simulazioni condotte su LTspice e sarà orientata all'individuazione di una metodologia di progetto generale per questo tipo di convertitori. Al fine di formalizzare meglio il progetto si è individuata una possibile applicazione nell'alimentazione di un DC-bus per telecomunicazioni (48 Volt DC sostenuti da batterie) a partire da una fonte di energia fotovoltaica quale una stringa di pannelli operanti con tensioni variabili da 120 a 180 Volt DC. Per questo particolare tipo di applicazione in discesa può avere senso l'impiego di un rettificatore del tipo a duplicazione di corrente, che quindi si provvederà a studiare e ad implementare a secondario del trasformatore d'isolamento. Infine particolare cura sarà dedicata alla parte di controllo che si ha intenzione di integrare all'interno di LTspice così da riuscire a simulare il comportamento dinamico del convertitore e verificare quanto predetto in via teorica mediante l'impiego della procedura che utilizza il K-Factor per la realizzazione della rete compensatrice.
Resumo:
In questa attività di tesi si indaga l’applicazione del biossido di titanio e delle sue proprietà fotocatalitiche su intonaci nell’architettura storica. Per questo motivo sono state studiate tre diverse tipologie di intonaci, a base di calce idraulica naturale, frequentemente usati per le facciate dell’architettura storica: intonaco di cocciopesto, intonaco di finitura e intonaco di finitura colorato. Inoltre per ogni tipologia di supporto sono stati indagati quattro diversi trattamenti: il solo biossido di titanio, la tinta, la tinta con biossido di titanio e il silicato di etile con TiO2.Nello specifico, l’attività di tesi si è concentrata sullo studio del trattamento a base di biossido di titanio in termini di prestazioni e durabilità. Per fare questo sono state condotte delle prove diagnostiche, quali l’assorbimento capillare, la permeabilità, la valutazione dell’angolo di contatto, la decolorazione con il blu di metilene. Viene condotta, inoltre, un’analisi qualitativa della variazione cromatica generata, sul substrato, dal trattamento. Il trattamento di TiO2, applicato a spray, risulta essere compatibile con tutti i supporti indagati, sia per la variazione cromatica, sia per la permeabilità al vapore che per l’assorbimento capillare. Per quel che concerne l’efficacia, è stato dimostrato come essa risulti particolarmente influenzata dalle proprietà del substrato.
Resumo:
L’attività di studio affrontata in questa tesi di laurea nasce da una collaborazione di 11 mesi con l’ufficio tecnico della Aghito Zambonini S.p.A. di Fiorenzuola d’Arda, azienda specializzata nella progettazione e produzione delle facciate continue in vetro. Il primo capitolo analizza lo scenario energetico globale, in termini di consumi e fabbisogni mondiali, confrontandoli con quelli dell’UE e dello stato italiano. Nel capitolo seguente viene analizzato il sistema costruttivo delle facciate continue in vetro, dal punto di vista architettonico (classificazione, requisiti e prestazioni, materiali) e dal punto di vista fisico. Una sezione è stata dedicata all’approfondimento delle facciate a doppia pelle. Dopo una descrizione dei software di simulazione energetica, il caso studio viene analizzato attraverso una simulazione di tipo stazionario con il software WIS 3.0 e con una simulazione di tipo dinamico, tramite il software sperimentale ESP-r. Oltre al caso effettivamente realizzato (CASO A), sono state simulate in ESP-r altre quattro alternative, di cui una considerante una maggior superficie di ventilazione (CASO B), una con intercapedine completamente chiusa (CASO C), una con doppio vetro in facciata al posto del triplo (CASO D) e un’ultima alternativa considera un vetro maggiormente performante nella pelle esterna (CASO E). I risultati ottenuti, in termini di temperatura, velocità dell’aria nell’intercapedine, consumi e parametri soggettivi di comfort, possono essere assunti generalmente validi per un qualsiasi sistema a doppia pelle e mostrano che due casi tra quelli simulati sono peggiorativi (CASO C, CASO D) e due migliorativi (CASO B e CASO E) rispetto a quello effettivamente realizzato. Da questo studio si deduce l’importanza di parametri quali geometria, orientazione, ventilazione e proprietà dei materiali già nel corso della fase di progettazione di un involucro edilizio.
Resumo:
Il presente elaborato propone un’analisi in regime dinamico mediante il software di simulazione TRNSYS di un impianto solare termico per la produzione di acqua calda sanitaria istallato in un condominio a Bologna. Le simulazioni rappresentano una particolare tipologia di esperimento numerico e possono fornire lo stesso tipo di informazioni sulle performance termiche dei comuni esperimenti fisici. Esse possono valutare gli effetti delle variabili di progetto sulle performance del sistema attraverso una serie di esperimenti, eseguiti tutti in identiche condizioni metereologiche e di carico. Le variabili di progetto esaminate in questo documento mediante simulazione sono l’inclinazione e orientamento del collettore, la superficie captante totale istallata, il volume di accumulo e la portata massima del circuito solare. Le analisi esposte sono un esempio dei risultati che un approccio simulativo può garantire; nel nostro caso, in particolare, le simulazioni hanno confermato la bontà dei criteri di dimensionamento degli impianti solari termici che è possibile incontrare in letteratura. Il presente elaborato si propone inoltre di discutere i benefici, ambientali ed economici, legati all’investimento proposto. L’analisi economica, in particolare, è stata eseguita a seconda dell’impianto tradizionale da affiancare, del diverso costo dell’impianto, di differenti valori di superficie captante e considerando o meno gli incentivi fiscali offerti: per questa valutazione è stato nuovamente necessario l’ausilio del software di simulazione.
Resumo:
Bio-logging studies suffer from the lack of real controls. However, it is still possible to compare indirect parameters between control and equipped animals to assess the level of global disturbance due to instrumentation. In addition, it is also possible to compare the behaviour of free-ranging animals between individuals equipped with different techniques or instruments to determine the less deleterious approach. We instrumented Adelie Penguins (Pygoscelis adeliae) with internal or external time-depth recorders and monitored them in parallel with a control group during the first foraging trip following instrumentation. Foraging trip duration was significantly longer in the internally-equipped group. This difference was due to a larger number of dives, reflecting a lower foraging ability or a higher food demand, and longer periods of recovery at the surface. These longer recovery periods were likely to be due to a reduced efficiency to ventilate at the surface, probably because the implanted devices pressurised adjacent organs such as air sacs. Moreover, descent and ascent rates were slightly lower in externally-equipped penguins, presumably because external instrumentation increased the bird drag. Looking at our results, implantation appears more disadvantageous - at least for short-term deployment - than external equipment in Adelie Penguins, while this method has been described to induce no negative effects in long-term studies. This underlines the need to control for potential effects due to methodological aspects in any study using data loggers in free-ranging animals, to minimise disturbance and collect reliable data.