984 resultados para PERSONNEL DOSIMETRY
Resumo:
Elevated rates of methicillin-resistant Staphylococcus aureus (MRSA) carriage have been reported in veterinary personnel, suggesting an occupational colonization risk. Hong Kong veterinary personnel (n = 150) were sampled for coagulase-positive staphylococci (CPS) nasal colonization. Risk factors for colonization were assessed by questionnaire. Isolates were identified and antibiotic susceptibility determined. All CPS isolates were investigated for mecA carriage, SCCmec type and PVL genes. Two subjects were colonized with methicillin-resistant CPS: one with MRSA (spa type t002 (CC5), SCCmec type II) and one with methicillin-resistant Staphylococcus pseudintermedius (MRSP) (MLST type ST71, SCCmec type II-III). MLST type ST71 S. pseudintermedius strain is the predominant MRSP clone circulating in dogs in Europe and in Hong Kong. The low MR-CPS colonization rate may be associated with low levels of large animal exposure or low rates of MRSA colonization of companion animals in Hong Kong. Colonization with non-aureus CPS, which may cause human infection, must also be considered in veterinary personnel.
Resumo:
A total of 70 Staphylococcus aureus isolates from postoperative infections in hospitalized horses were isolated between January 2005 and January 2011. Among them, 12 isolates were methicillin-susceptible S. aureus (MSSA), 18 were borderline-oxacillin-resistant S. aureus (BORSA), and 40 were methicillin-resistant S. aureus (MRSA). During the same period, the equine clinic personnel were screened for nasal carriage of BORSA and MRSA. Genotyping revealed that BORSA ST1(MLST)-t2863(spa) isolates were responsible for most equine infections and were the main isolates found in colonized members of the personnel between 2005 and 2007, and that in 2007, MRSA ST398-t011-IVa(SCCmec) emerged in infection sites and personnel, replacing BORSA. Besides decreased susceptibility to oxacillin, all MRSA and BORSA of these two major clonal lineages displayed resistance to gentamicin and kanamycin conferred by the aac(6')-Ie-aph(2')-Ia gene and to trimethoprim conferred by dfr(K) in MRSA and dfr(A) in BORSA. All MRSA had additional resistance to tetracycline conferred by tet(M), whereas BORSA generally also display resistance to streptomycin conferred by str. The number of hospital-acquired MRSA infections in horses could be limited after the introduction of basic hygiene measures and personnel decolonization. Two MRSA carriers could not be decolonized using mupirocin, and a year after decolonization, additional members were recolonized with MRSA. Hygiene measures should, therefore, be maintained to limit the transmission of S. aureus between personnel and horses.
Resumo:
Today electronic portal imaging devices (EPID's) are used primarily to verify patient positioning. They have, however, also the potential as 2D-dosimeters and could be used as such for transit dosimetry or dose reconstruction. It has been proven that such devices, especially liquid filled ionization chambers, have a stable dose response relationship which can be described in terms of the physical properties of the EPID and the pulsed linac radiation. For absolute dosimetry however, an accurate method of calibration to an absolute dose is needed. In this work, we concentrate on calibration against dose in a homogeneous water phantom. Using a Monte Carlo model of the detector we calculated dose spread kernels in units of absolute dose per incident energy fluence and compared them to calculated dose spread kernels in water at different depths. The energy of the incident pencil beams varied between 0.5 and 18 MeV. At the depth of dose maximum in water for a 6 MV beam (1.5 cm) and for a 18 MV beam (3.0 cm) we observed large absolute differences between water and detector dose above an incident energy of 4 MeV but only small relative differences in the most frequent energy range of the beam energy spectra. It is shown that for a 6 MV beam the absolute reference dose measured at 1.5 cm water depth differs from the absolute detector dose by 3.8%. At depth 1.2 cm in water, however, the relative dose differences are almost constant between 2 and 6 MeV. The effects of changes in the energy spectrum of the beam on the dose responses in water and in the detector are also investigated. We show that differences larger than 2% can occur for different beam qualities of the incident photon beam behind water slabs of different thicknesses. It is therefore concluded that for high-precision dosimetry such effects have to be taken into account. Nevertheless, the precise information about the dose response of the detector provided in this Monte Carlo study forms the basis of extracting directly the basic radiometric quantities photon fluence and photon energy fluence from the detector's signal using a deconvolution algorithm. The results are therefore promising for future application in absolute transit dosimetry and absolute dose reconstruction.
Resumo:
Individual monitoring regulations in Switzerland are based on the ICRP60 recommendations. The annual limit of 20 mSv for the effective dose applies to the sum of external and internal radiation. External radiation is monitored monthly or quarterly with TLD, DIS or CR-39 dosemeters by 10 approved external dosimetry services and reported as H(p)(10) and H(p)(0.07). Internal monitoring is done in two steps. At the workplace, simple screening measurements are done frequently in order to recognise a possible incorporation. If a nuclide dependent activity threshold is exceeded then one of the seven approved dosimetry services for internal radiation does an incorporation measurement to assess the committed effective dose E(50). The dosimetry services report all the measured or assessed dose values to the employer and to the National Dose Registry. The employer records the annually accumulated dose values into the individual dose certificate of the occupationally exposed person, both the external dose H(p)(10) and the internal dose E(50) as well as the total effective dose E = H(p)(10)+E(50). Based on the national dose registry an annual report on the dosimetry in Switzerland is published which contains the statistics for the total effective dose, as well as separate statistics for external and internal exposure.
Resumo:
Tungsten isotope compositions of magmatic iron meteorites yield ages of differentiation that are within ±2 Ma of the formation of CAIs, with the exception of IVB irons that plot to systematically less radiogenic compositions yielding erroneously old ages. Secondary neutron capture due to galactic cosmic ray (GCR) irradiation is known to lower the ε182W of iron meteorites, adequate correction of which requires a measure of neutron dosage which has not been available, thus far. The W, Os and Pt isotope systematics of 12 of the 13 known IVB iron meteorites were determined by MC-ICP-MS (W, Os, Pt) and TIMS (Os). On the same dissolutions that yield precise ε182W, stable Os and Pt isotopes were determined as in situ neutron dosimeters for empirical correction of the ubiquitous cosmic-ray induced burn-out of 182W in iron meteorites. The W isotope data reveal a main cluster with ε182W of ∼−3.6, but a much larger range than observed in previous studies including irons (Weaver Mountains and Warburton Range) that show essentially no cosmogenic effect on their ε182W. The IVB data exhibits resolvable negative anomalies in ε189Os (−0.6ε) and complementary ε190Os anomalies (+0.4ε) in Tlacotepec due to neutron capture on 189Os which has approximately the same neutron capture cross section as 182W, and captures neutrons to produce 190Os. The least irradiated IVB iron, Warburton Range, has ε189Os and ε190Os identical to terrestrial values. Similarly, Pt isotopes, which are presented as ε192Pt, ε194Pt and ε196Pt range from +4.4ε to +53ε, +1.54ε to −0.32ε and +0.73ε to −0.20ε, respectively, also identify Tlacotepec and Dumont as the most GCR-damaged samples. In W–Os and W–Pt isotope space, the correlated isotope data back-project toward a 0-epsilon value of ε192Pt, ε189Os and ε190Os from which a pre-GCR irradiation ε182W of −3.42±0.09 (2σ) is derived. This pre-GCR irradiation ε182W is within uncertainty of the currently accepted CAI initial ε182W. The Pt and Os isotope correlations in the IVB irons are in good agreement with a nuclear model for spherical irons undergoing GCR spallation, although this model over-predicts the change of ε182W by ∼2×, indicating a need for better W neutron capture cross section determinations. A nucleosynthetic effect in ε184W in these irons of −0.14±0.08 is confirmed, consistent with the presence of Mo and Ru isotope anomalies in IVB irons. The lack of a non-GCR Os isotope anomaly in these irons requires more complex explanations for the production of W, Ru and Mo anomalies than nebular heterogeneity in the distribution of s-process to r-process nuclides.
Resumo:
Virtual colonoscopy (VC) is a minimally invasive means for identifying colorectal polyps and colorectal lesions by insufflating a patient’s bowel, applying contrast agent via rectal catheter, and performing multi-detector computed tomography (MDCT) scans. The technique is recommended for colonic health screening by the American Cancer Society but not funded by the Centers for Medicare and Medicaid Services (CMS) partially because of potential risks from radiation exposure. To date, no in‐vivo organ dose measurements have been performed for MDCT scans; thus, the accuracy of any current dose estimates is currently unknown. In this study, two TLDs were affixed to the inner lumen of standard rectal catheters used in VC, and in-vivo rectal dose measurements were obtained within 6 VC patients. In order to calculate rectal dose, TLD-100 powder response was characterized at diagnostic doses such that appropriate correction factors could be determined for VC. A third-order polynomial regression with a goodness of fit factor of R2=0.992 was constructed from this data. Rectal dose measurements were acquired with TLDs during simulated VC within a modified anthropomorphic phantom configured to represent three sizes of patients undergoing VC. The measured rectal doses decreased in an exponential manner with increasing phantom effective diameter, with R2=0.993 for the exponential regression model and a maximum percent coefficient of variation (%CoV) of 4.33%. In-vivo measurements yielded rectal doses ranged from that decreased exponentially with increasing patient effective diameter, in a manner that was also favorably predicted by the size specific dose estimate (SSDE) model for all VC patients that were of similar age, body composition, and TLD placement. The measured rectal dose within a younger patient was favorably predicted by the anthropomorphic phantom dose regression model due to similarities in the percentages of highly attenuating material at the respective measurement locations and in the placement of the TLDs. The in-vivo TLD response did not increase in %CoV with decreasing dose, and the largest %CoV was 10.0%.
Resumo:
Intensity modulated radiation therapy (IMRT) is a technique that delivers a highly conformal dose distribution to a target volume while attempting to maximally spare the surrounding normal tissues. IMRT is a common treatment modality used for treating head and neck (H&N) cancers, and the presence of many critical structures in this region requires accurate treatment delivery. The Radiological Physics Center (RPC) acts as both a remote and on-site quality assurance agency that credentials institutions participating in clinical trials. To date, about 30% of all IMRT participants have failed the RPC’s remote audit using the IMRT H&N phantom. The purpose of this project is to evaluate possible causes of H&N IMRT delivery errors observed by the RPC, specifically IMRT treatment plan complexity and the use of improper dosimetry data from machines that were thought to be matched but in reality were not. Eight H&N IMRT plans with a range of complexity defined by total MU (1460-3466), number of segments (54-225), and modulation complexity scores (MCS) (0.181-0.609) were created in Pinnacle v.8m. These plans were delivered to the RPC’s H&N phantom on a single Varian Clinac. One of the IMRT plans (1851 MU, 88 segments, and MCS=0.469) was equivalent to the median H&N plan from 130 previous RPC H&N phantom irradiations. This average IMRT plan was also delivered on four matched Varian Clinac machines and the dose distribution calculated using a different 6MV beam model. Radiochromic film and TLD within the phantom were used to analyze the dose profiles and absolute doses, respectively. The measured and calculated were compared to evaluate the dosimetric accuracy. All deliveries met the RPC acceptance criteria of ±7% absolute dose difference and 4 mm distance-to-agreement (DTA). Additionally, gamma index analysis was performed for all deliveries using a ±7%/4mm and ±5%/3mm criteria. Increasing the treatment plan complexity by varying the MU, number of segments, or varying the MCS resulted in no clear trend toward an increase in dosimetric error determined by the absolute dose difference, DTA, or gamma index. Varying the delivery machines as well as the beam model (use of a Clinac 6EX 6MV beam model vs. Clinac 21EX 6MV model), also did not show any clear trend towards an increased dosimetric error using the same criteria indicated above.
Resumo:
This study of ambulance workers for the emergency medical services of the City of Houston studied the factors related to shiftwork tolerance and intolerance. The EMS personnel work a 24-hour shift with rotating days of the week. Workers are assigned to A, B, C, D shift, each of which rotate 24-hours on, 24-hours off, 24-hours on and 4 days off. One-hundred and seventy-six male EMTs, paramedics and chauffeurs from stations of varying levels of activity were surveyed. The sample group ranged in age from 20 to 45. The average tenure on the job was 8.2 years. Over 68% of the workers held a second job, the majority of which worked over 20 hours a week at the second position.^ The survey instrument was a 20-page questionnaire modeled after the Folkard Standardized Shiftwork Index. In addition to demographic data, the survey tool provided measurements of general job satisfaction, sleep quality, general health complaints, morningness/eveningness, cognitive and somatic anxiety, depression, and circadian types. The survey questionnaire included an EMS-specific scaler of stress.^ A conceptual model of Shiftwork Tolerance was presented to identify the key factors examined in the study. An extensive list of 265 variables was reduced to 36 key variables that related to: (1) shift schedule and demographic/lifestyle factors, (2) individual differences related to traits and characteristics, and (3) tolerance/intolerance effects. Using the general job satisfaction scaler as the key measurement of shift tolerance/intolerance, it was shown that a significant relationship existed between this dependent variable and stress, number of years working a 24-hour shift, sleep quality, languidness/vigorousness. The usual amount of sleep received during the shift, general health complaints and flexibility/rigidity (R$\sp2$ =.5073).^ The sample consisted of a majority of morningness-types or extreme-morningness types, few evening-types and no extreme-evening types, duplicating the findings of Motohashi's previous study of ambulance workers. The level of activity by station was not significant on any of the dependent variables examined. However, the shift worked had a relationship with sleep quality, despite the fact that all shifts work the same hours and participate in the same rotation schedule. ^
Resumo:
Background Workflow interruptions during surgery may cause a threat to patient's safety. Workflow interruptions were tested to predict failure in action regulation that in turn predicts near-accidents in surgery and related health care. Methods One-hundred-and-thirty-three theater nurses and physicians from eight Swiss hospitals participated in a cross-sectional questionnaire survey. The study participation rate was 43%. Results Structural equation modeling confirmed an indirect path from workflow interruptions through cognitive failure in action regulation on near-accidents (p < 0.05). The indirect path was stronger for workflow interruptions by malfunctions and task organizational blockages compared with workflow interruptions that were caused by persons. The indirect path remained meaningful when individual differences in conscientiousness and compliance with safety regulations were controlled. Conclusion Task interruptions caused by malfunction and organizational constraints are likely to trigger errors in surgery. Work redesign is recommended to reduce workflow interruptions by malfunction and regulatory constraints.