988 resultados para Osseointegrated dental implants


Relevância:

90.00% 90.00%

Publicador:

Resumo:

ObjectiveTo study bone healing at implants installed with different insertion torques.Material and methodsIn six Labrador dogs, all mandibular premolars and first molars were extracted. After 4months of healing, flaps were elevated, and two implant sites were prepared at each side of the mandible. In the right side of the mandible, the distal sites were prepared conventionally, while the mesial sites were over-prepared by 0.2mm. As a consequence, a final insertion torque of similar to 30Ncm at the distal and a minimal insertion torque close to 0Ncm at the mesial sites were obtained. In the left sides of the mandible, however, the recipient sites were underprepared by 0.3mm resulting in an insertion torque of 70Ncm at both implants. Cover screws were applied, and flaps sutured to fully submerge the experimental sites. After 4months, the animals were sacrificed and ground sections obtained for histological evaluation.ResultsThe mineralized bone-to-implant contact was in the range of 55.2-62.1%, displaying the highest value at implants with similar to 30Ncm insertion torque and the lowest value at the implant sites with close to 0Ncm insertion torque. No statistically significant differences were revealed. Bone density was in the range of 43.4-54.9%, yielding the highest value at implants with 70Ncm insertion torque and the lowest at the implant sites with close to 0Ncm insertion torque. The difference between the sites of similar to 30Ncm and the corresponding 70Ncm insertion torque reached statistical significance.ConclusionsSimilar amounts of osseointegration were obtained irrespective of the insertion torque applied. Moreover, implants installed in sites with close to 0Ncm insertion torque may properly osseointegrate as well.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

AimTo evaluate prospectively the clinical and radiographic outcomes after 5years of early loading of 6-mm implants with a moderately rough (SLActive((R))) surface supporting single crowns in the posterior regions.Material and methodsThirty-five consecutive patients received 40 SLActive((R)) (Straumann) 6-mm implants with a diameter of 4.1mm (n=19) or 4.8mm (n=21). Insertion torque and resonance frequency analysis (RFA) were measured at implant installation. RFA was also measured at abutment connection. SynOcta abutments were tightened with 35Ncm after 6weeks of healing, and single porcelain fuse to metal crowns was cemented within 1week. Implant survival rate and marginal bone loss were evaluated at various time intervals until 5years after loading. The clinical crown/implant ratio was calculated as well.ResultsTwo of 40 implants were lost before loading (incorporation rate 95%), and no further implant loss or technical complications were encountered during the 5-year follow-up period. A mean marginal bone loss of 0.70.6mm was found after 5years of function. The clinical crown/implant ratio increased with time from 1.6 at the delivery of the prosthesis to 2 after 5years of loading.ConclusionSix millimeter implants with a SLActive((R)) moderately rough surface supporting single crowns in the posterior region and loaded after 6-7weeks maintained full function for at least 5year with low marginal bone resorption.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Short implants are increasingly used, but there is doubt about their performance being similar to that of regular implants. The aim of this study was to compare the mechanical stability of short implants vs. regular implants placed in the edentulous posterior mandible. Twenty-three patients received a total of 48 short implants (5 × 5.5 mm and 5 × 7 mm) and 42 regular implants (4 × 10 mm and 4 × 11.5 mm) in the posterior mandible. Patients who received short implants had <10 mm of bone height measured from the bone crest to the outer wall of the mandibular canal. Resonance frequency analysis (RFA) was performed at time intervals T0 (immediately after implant placement), T1 (after 15 days), T2 (after 30 days), T3 (after 60 days), and T4 (after 90 days). The survival rate after 90 days was 87.5% for the short implants and 100% for regular implants (P < 0.05). There was no significant difference between the implants in time intervals T1, T2, T3, and T4. In T0, the RFA values of 5 × 5.5 implants were higher than values of 5 × 7 and 4 × 11.5 implants (P < 0.05). A total of six short implants that were placed in four patients were lost (three of 5 × 5.5 mm and three of 5 × 7 mm). Three lost implants started with high ISQ values, which progressively decreased. The other three lost implants started with a slightly lower ISQ value, which rose and then began to fall. Survival rate of short implants after 90 days was lower than that of regular implants. However, short implants may be considered a reasonable alternative for rehabilitation of severely resorbed mandibles with reduced height, to avoid performing bone reconstruction before implant placement. Patients need to be aware of the reduced survival rate compared with regular implants before implant placement to avoid disappointments.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The aim of this study was to evaluate the survival of single dental implants subjected to immediate function. Twelve patients with edentulous areas in the posterior mandible were included in the study. All received at least one regular platform dental implant (3.75mm×11mm or 3.75mm×13mm). Clinical and radiographic parameters were evaluated. The survival rate after 12 months was 83.3%. The implants showed no clinical mobility, had implant stability quotient values (ISQ; Osstell) around 70, bone loss of up to 2mm, and a probing depth of ≤3mm. Although the posterior mandible is an area in which the immediate loading of dental implants should be performed with caution, this treatment presented a good success rate in the present study sample.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

To compare peri-implant soft- and hard-tissue integration at implants installed juxta- or sub-crestally. Furthermore, differences in the hard and soft peri-implant tissue dimensions at sites prepared with drills or sonic instruments were to be evaluated. Three months after tooth extraction in six dogs, recipient sites were prepared in both sides of the mandible using conventional drills or a sonic device (Sonosurgery(®) ). Two implants with a 1.7-mm high-polished neck were installed, one with the rough/smooth surface interface placed at the level of the buccal bony crest (control) and the second placed 1.3 mm deeper (test). After 8 weeks of non-submerged healing, biopsies were harvested and ground sections prepared for histological evaluation. The buccal distances between the abutment/fixture junction (AF) and the most coronal level of osseointegration (B) were 1.6 ± 0.6 and 2.4 ± 0.4 mm; between AF and the top of the bony crest (C), they were 1.4 ± 0.4 and 2.2 ± 0.2 mm at the test and control sites, respectively. The top of the peri-implant mucosa (PM) was located more coronally at the test (1.2 ± 0.6 mm) compared to the control sites (0.6 ± 0.5 mm). However, when the original position of the bony crest was taken into account, a higher bone loss and a more apical position of the peri-implant mucosa resulted at the test sites. The placement of implants into a sub-crestal location resulted in a higher vertical buccal bone resorption and a more apical position of the peri-implant mucosa in relation to the level of the bony crest at implant installation. Moreover, peri-implant hard-tissue dimensions were similar at sites prepared with either drills or Sonosurgery(®) .

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The aim of this study was to analyze the stress distribution of short implants supporting single unit or splinted crowns by the photo-elasticity method. Four photo-elastic models were produced: A (3.75×7mm); B (3.75×7mm, 3.75×7mm and 3.75×7mm); C (3.75×10mm, 3.75×7mm and 3.75×7mm); D (3.75×13mm, 3.75×7mm and 3.75×7mm). The prostheses were made with Ni-Cr alloy. A load of 100N in the axial and oblique directions was applied, totaling 380 applications, individually capturing their images in each model. The data were randomized and analyzed qualitatively and quantitatively by 2 examiners. The oblique loading was significantly more damaging. The increase in length was favorable for stress distribution (p<0.05). The splinting was beneficial for the transmission of stresses mainly (p<0.05). The splinting of the crowns, as well as increasing the length of the first implant and axial loading was most beneficial in the stress distribution. Short splinted implants behaved better than single unit implants. Increasing of the length of the first implant significantly improved the stress distribution in all analyzed situations.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This case report is an 8-year follow-up of a malpositioned single implant, which was treated with segmental osteotomy, to confirm the treatment's characteristics, indications, and advantages. Deep buccal positioning of an endosseous implant placed in the maxillary left central incisor area did not permit acceptable prosthetic rehabilitation, despite its favorable bone insertion with no significant marginal bone loss. The surgical procedure included osteotomy and block movement performed toward the lingual and cervical position, fixed with a provisional prosthesis and miniplates and mini-implants. A connective tissue graft was necessary for esthetics optimization and was performed in a second stage. Advantages including the prevention of alveolar ridge damage, the improvement of gingival contour, and the use of an already integrated implant are presented. Clinically satisfactory hard and soft tissue stability permitted us to consider segmental surgery as a reliable alternative for malpositioned osseointegrated implants.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The design of implant structure is still a questioning to the professionals, while their variations can to influence of stress distribution favorably to bone. Therefore, the aim of study was to review addressing the topic of osseointegrated implants design establishing answers for the patient oral rehabilitation, according variations existing on the market. It was conducted a detailed search strategy by the PubMed/ Medline and Bireme, it was used as descriptors: “dental implants cylinder”; “dental implants thread”; “dental implants geometry”, until May 2014. From 798 articles, after review were selected 18 articles and 1 specific area book. The results were divided to compare design of implant and threads for further discussion and conclusions. Thus, conclude that the threads implants are best used because of its advantages with respect to the stress distribution and stability primary. The variations of the differents types of threads, have influence for stress distribution.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The oral rehabilitation has achieved great prominence in the dental implant, especially in the cases of reposition of units dental elements, so it is possible to replace each missing element to implant into your space where the tooth was loss. The reverse planning is fundamental to an appropriate rehabilitation, because promote the elimination of problems that might compromise the aesthetics and function of future dental implants. The objective of this study was to report the treatment plan for a patient in need of oral rehabilitation with implant dental prosthesis, using indications and techniques based on the literature, emphasizing the importance of reverse planning. We conducted an osseointegrated implant surgery using the principles of a connect procedure, thus allowing their successfully installing increasing the predictability of treatment. It is concluded that the success of rehabilitation treatment is directly related to the initial planning, a correct clinical approach and an integrated multidisciplinary team.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The dissatisfaction of the treatment with mandibular complete dentures in edentulous patients has been a constant problem in Dentistry. Often, the absence of stability and retention, resultants of a physiologic condition and alveolar ridge resorption, bring reduction of chewing force, speech problems and social life interference. In these cases, the rehabilitation over osseointegrated implants can be an effective and safe alternative of treatment. When it is not possible to put implants in appropriate number and disposition, it is necessary to make a simple and low costing prosthetic planning, which makes resurge the overdentures. Various implant supported attachment systems for overdentures have been developed in the dental market. Thus, intending to facilitate the professional choice, this study review the literature about attachment systems O’ring and bar- clip in its following aspect: retention level, stress distribution, hygiene complications and patient satisfaction.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The obstructive sleep apnea syndrome affects millions of people around the world. The mandibular repositioning devices have been indicated in cases of mild/moderate syndrome; however in edentulous patients its use is deficient since there is no retention. Therefore the objective of this study was to conduct a review on the use of this treatment method combined to osseointegrated implants. A search on the theme: Dental implant and sleep apnea syndromewas performed in the Medline/PubMed, ISI, Cochrane, Dentistry Oral Science, Clinical Trials, Controlled Trials, and Bireme-BvS, databases, and 22 articles were found. After anevaluation 2 studies were selected and the review was complemented with an analysis of randomized controlled trials in the previous seven bases using the key-words: Sleep apnea syndrome, Oral appliance and Randomized controlled trial. The search returned 37 articles, and after they were submitted to inclusion criteria 17 studies were selected. There are a small number of studies presenting the use of dental implants as a mean to assist the stabilization of the mandibular repositioning appliances; those that are available are case reports that focusing on the effectiveness of the technique. Studies examining the effect these appliances in dentate patients indicate improvement in the levels of apnea and snoring. The use of mandibular repositioning appliances in dentate patients is an effective technique in treatment of patients with obstructive sleep apnea syndrome mild/moderate. Randomized controlled trialsare required in order to enable an analysis of the use of mandibular repositioning devices with the aid of dental implants .

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Purpose: This study aimed to investigate the etiology, clinical manifestations, and treatment options of dental implants fractures through a literature review and to relate a clinical report. Methods: A literature review was performed using the Medline database and this paper describes a case demonstrating the management of implant fracture. Twenty two articles were selected in the present literature review. Results: Nowadays the use of dental implants to rehabilitate completely and partially edentulous patients became the best treatment option; however, this treatment is suitable to failure. The fracture of implant body is a possible complication. The fracture of implant body is a late complication and is related to the failure in implant design or material, non-passive fitting of the prosthetic crown and overloading. Clinically, prosthesis instability and spontaneous bleeding are observed. Three options of treatment have been indicated: complete removal of implant fragment, maintenance of implant fragment, and surface preparation of the fragment with insertion of a new abutment. Conclusion: The literature indicates the complete removal of the fragment as the best treatment option.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Placement of implants in fresh sockets is an alternative to try to reduce physiological resorption of alveolar ridge after tooth extraction. This surgery can be used to preserve the bone architecture and also accelerate the restorative procedure. However, the diastasis observed between bone and implant may influence osseointegration. So, autogenous bone graft and/or biomaterials have been used to fill this gap. Considering the importance of bone repair for treatment with implants placed immediately after tooth extraction, this study aimed to present a literature review about biomaterials surrounding immediate dental implants. The search included 56 articles published from 1969 to 2012. The results were based on data analysis and discussion. It was observed that implant fixation immediately after extraction is a reliable alternative to reduce the treatment length of prosthetic restoration. In general, the biomaterial should be used to increase bone/implant contact and enhance osseointegration.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Dentoalveolar traumatisms, particularly those that affect the anterior teeth, interfere adversely in the patient s life.Among them, tooth avulsion is pointed out because it is characterized as a complex injury that affects multiple tissues, andbecause there is no effective treatment available for its resolution with a stable long-term outcome.Aim/Hypothesis: The aim of the present study was to relate a clinical case of complete reconstruction of atrophy of the alveolarbone corresponding to tooth 11, lost by tooth resorption 10 years after the tooth reimplantation procedure.Material and methods: Reconstruction was performed with autogenous bone harvested from the mentum donor site. Surgicalaccess began in the receptor area with a Newman mucoperiosteal incision using a scalpel blade 15 mounted in a scalpel handlefor detachment and exposure of the receptor site. Extensive bone resorption was observed in the vestibular-palatine direction,proved by the thinness of the receptor bed. Decorticalization of the vestibular bone plate was performed. After preparing thereceptor bed, and incision was made in the mucosa in the depth of the anterior vestibular fornix, then a perpendicular muscleperiostealincision to detach and exposure the donor area. The bone graft necessary for reconstruction of the donor area wasdelimited, followed by monocortical osteotomy and the monocortical graft was removed. The next stage was to perform shapingfor passive graft accommodation and fixation by means of two bicortical screws. After fixation of the graft the sharp angles wererounded off in order to avoid possible exposure and/or fenestrations of the reconstructed area, then the receptor and donor areawere sutured. After the 6-month period to allow incorporation of the autogenous graft, an osseointegrated dental implant wasinserted. At the end of the 6-month period of waiting for osseointegration to occur, the process of fabricating the screw-retainedmetal ceramic