814 resultados para Optical detection systems
Resumo:
Ecological studies that examine species-environment relationships are often limited to several meteorological parameters, i.e. mean air temperature, relative humidity, precipitation, vapour pressure deficit and solar radiation. The impact of local wind, its speed and direction are less commonly investigated in aerobiological surveys mainly due to difficulties related to the employment of specific analytical tools and interpretation of their outputs. Identification of inoculum sources of economically important plant pathogens, as well as highly allergenic bioaerosols like Cladosporium species, has not been yet explored with remote sensing data and atmospheric models such as Hybrid Single Particle Lagrangian Integrated Trajectory (HYSPLIT). We, therefore, performed an analysis of 24 h intra-diurnal cycle of Cladosporium spp. spores from an urban site in connection with both the local wind direction and overall air mass direction computed by HYSPLIT. The observational method was a volumetric air sampler of the Hirst design with 1 h time resolution and corresponding optical detection of fungal spores with light microscopy. The atmospheric modelling was done using the on-line data set from GDAS with 1° resolution and circular statistical methods. Our results showed stronger, statistically significant correlation (p ≤ 0.05) between high Cladosporium spp. spore concentration and air mass direction compared to the local wind direction. This suggested that a large fraction of the investigated fungal spores had a regional origin and must be located more than a few kilometers away from the sampling point.
Resumo:
A norfloxacina e o trimetoprim são dois antibióticos antibacterianos usados para o tratamento de infeções urinárias, intestinais e respiratórias. A maioria dos fármacos exige uma dosagem que garanta os níveis de segurança e eficácia de atuação. A necessidade de dosear os medicamentos e os seus metabolitos é assim um controlo imperioso e em muitos casos regular no tratamento de um paciente. Neste trabalho desenvolveram-se dois sensores eletroquímicos para a deteção da norfloxacina (NFX) e do trimetoprim (TMP), usando como superfície de suporte o carbono vítreo. A busca de novos materiais que conferiram maior seletividade e sensibilidade aos sistemas de deteção e por outro lado apresentem menores riscos para o paciente quando usados em dispositivos que permitam uma análise point-of-care, é especialmente importante e pode ser uma parte crucial do processo de decisão clínica. Assim, os polímeros molecularmente impresos enquadram-se nesse perfil e o seu uso tem vindo a ser cada vez mais avaliado. A impressão molecular é uma tecnologia capaz de produzir polímeros que incorporam as moléculas do analito e que após remoção por solventes específicos, permitem dotá-los de locais específicos de reconhecimento estereoquímico. A seleção do pirrol como polímero molecularmente impresso (MIP) permitiu construir com sucesso os sensores para doseamento dos antibióticos. A fim de aumentar a sensibilidade do método incorporou-se grafeno na superfície do elétrodo. Este material tem vindo a ser largamente utilizado devido às suas propriedades: estrutura molecular, condutividade elétrica e aumento da superfície são algumas das características que mais despertam o interesse para a sua aplicação neste projeto. Os sensores desenvolvidos foram incorporados em sistemas eletroquímicos. Os métodos voltamétricos aplicados foram a voltametria cíclica, a voltametria de onda quadrada e ainda a impedância. As condições de análise foram otimizadas no que respeita à polimerização do pirrol (concentração do polímero, número de ciclos de eletropolimerização e respetivos potenciais aplicados, tempo de incubação, solvente de remoção do analito), ao pH da solução do fármaco, à gama de concentrações dos antibióticos e aos parâmetros voltamétricos dos métodos de análise. Para cada um dos antibióticos um elétrodo não-impresso foi também preparado, usando o procedimento de polimerização mas sem a presença da molécula do analito, e foi usado como controlo. O sensor desenvolvido para o trimetoprim foi usado no doseamento do fármaco em amostras de urina. As amostras foram analisadas sem qualquer diluição, apenas foram centrifugadas para remoção de proteínas e algum interferente. Os sensores construídos apresentaram comportamento linear na gama de concentrações entre 102 e 107 mol/L. Os resultados mostram boa precisão (desvios padrão inferiores a 11%) e os limites de deteção foram de 8,317 e 1,307 mol/L para a norfloxacina e o trimetoprim, respetivamente. Para validação do método foram ainda efetuados ensaios de recuperação tendo obtido valores superiores a 94%.
Resumo:
Com um mercado automóvel cada vez mais competitivo e com os construtores automóveis à procura de atingir os zero defeitos nos seus produtos, a Bosch Car Multimédia Portugal S.A, fabricante de sistemas multimédia para o mercado automóvel, tem como objetivo a qualidade perfeita dos seus produtos. Tal perfeição exige processos de fabrico cada vez mais evoluídos e com melhores sistemas de auxílio à montagem. Nesse sentido, a incorporação de sistemas de visão artificial para verificação da montagem correta dos componentes em sistemas multimédia tem vindo a crescer largamente. Os sistemas de inspeção visual da Cognex tornaram-se o standard da Bosch para a verifi-cação da montagem de componentes por serem sistemas bastante completos, fáceis de con-figurar e com um suporte técnico bastante completo. Estes sistemas têm vindo a ser inte-grados em diversas máquinas (postos) de montagem e nunca foi desenvolvida uma ferra-menta normalizada para integração destes sistemas com as máquinas. A ideia principal deste projeto passou por desenvolver um sistema (uma aplicação informá-tica) que permita controlar os indicadores de qualidade destes sistemas de visão, garantir o seguimento dos produtos montados e, ao mesmo tempo, efetuar cópias de segurança de todo o sistema para utilização em caso de avaria ou de troca de equipamento. Tal sistema foi desenvolvido recorrendo à programação de uma Dynamic Link Library (DLL), através da linguagem VisualBasic.NET, que permite às aplicações dos equipamen-tos (máquinas) da Bosch Car Multimédia comunicarem de uma forma universal e transpa-rente com os sistemas de inspeção visual da marca Cognex. Os objetivos a que o autor se propôs no desenvolvimento deste sistema foram na sua maioria alcançados e o projeto encontra-se atualmente implementado e em execução nas linhas de produção da Bosch Car Multimédia.
Resumo:
A Segurança Contra Incêndios em Edifícios representa uma parte importante nos projetos de engenharia, uma vez que tem de ser analisada e implementada desde o início da construção. O principal objetivo é oferecer confiança aos utilizadores dos edifícios, aos seus bens e sistemas, sempre de acordo com a lei. Em qualquer tipo de edifício é iminente a capacidade de, por diversos motivos e circunstâncias, se iniciar um incêndio. O que se pretende com toda a regulamentação e matéria sobre a Segurança Contra Incêndios em Edifícios é a aplicação de sistemas de deteção, prevenção e extinção de incêndios, conseguindo, deste modo, reduzir os seus efeitos negativos. Este relatório de estágio apresenta, de um modo geral, a importância da Segurança Contra Incêndios em Edifícios atualmente nas construções, quais as principais regras neste âmbito, bem como a apresentação de todos os equipamentos e sistemas que fazem parte dos sistemas de SCIE. O presente relatório culmina com a vertente prática que consiste na descrição de casos acompanhados durante os meses de estágio, vistorias efetuadas e ensaios de incêndio. Os fenómenos inerentes a um alarme de incêndio serão descritos e comprovados em situações reais de simulação.
Resumo:
RESUMO - A Segurança do Doente tem assumido uma relevância crescente nas organizações de saúde, resultado da divulgação de diversos estudos que revelaram a magnitude deste problema e simultaneamente, de uma maior pressão por parte da opinião pública e da comunicação social. Este estudo pretende desenvolver e avaliar a performance de um sistema eletrónico de deteção de eventos adversos, baseado num Data Warehouse, por comparação com os resultados obtidos pela metodologia tradicional de revisão dos registos clínicos. O objetivo principal do trabalho consistiu em identificar um conjunto de triggers / indicadores de alerta que permitam detetar potenciais eventos adversos mais comuns. O sistema desenvolvido apresentou um Valor Preditivo Positivo de 18.2%, uma sensibilidade de 65.1% e uma especificidade de 68.6%, sendo constituído por nove indicadores baseados em informação clínica e 445 códigos do ICD-9-CM, relativos a diagnósticos e procedimentos. Apesar de terem algumas limitações, os sistemas eletrónicos de deteção de eventos adversos apresentam inúmeras potencialidades, nomeadamente a utilização em tempo real e em complemento a metodologias já existentes. Considerando a importância da problemática em análise e a necessidade de aprofundar os resultados obtidos neste trabalho de projeto, seria relevante a sua extensão a um universo mais alargado de instituições hospitalares, estando a sua replicabilidade facilitada, uma vez que o Data Warehouse tem por base um conjunto de aplicações disseminadas a nível nacional. O desenvolvimento e a consolidação dos sistemas eletrónicos de deteção de eventos adversos constitui inegavelmente uma área de futuro, com reflexos ao nível da melhoria da informação existente nas organizações e que contribuirá decisivamente para a melhoria dos cuidados de saúde prestados aos doentes.
Resumo:
Confocal and two-photon microcopy have become essential tools in biological research and today many investigations are not possible without their help. The valuable advantage that these two techniques offer is the ability of optical sectioning. Optical sectioning makes it possible to obtain 3D visuahzation of the structiu-es, and hence, valuable information of the structural relationships, the geometrical, and the morphological aspects of the specimen. The achievable lateral and axial resolutions by confocal and two-photon microscopy, similar to other optical imaging systems, are both defined by the diffraction theorem. Any aberration and imperfection present during the imaging results in broadening of the calculated theoretical resolution, blurring, geometrical distortions in the acquired images that interfere with the analysis of the structures, and lower the collected fluorescence from the specimen. The aberrations may have different causes and they can be classified by their sources such as specimen-induced aberrations, optics-induced aberrations, illumination aberrations, and misalignment aberrations. This thesis presents an investigation and study of image enhancement. The goal of this thesis was approached in two different directions. Initially, we investigated the sources of the imperfections. We propose methods to eliminate or minimize aberrations introduced during the image acquisition by optimizing the acquisition conditions. The impact on the resolution as a result of using a coverslip the thickness of which is mismatched with the one that the objective lens is designed for was shown and a novel technique was introduced in order to define the proper value on the correction collar of the lens. The amoimt of spherical aberration with regard to t he numerical aperture of the objective lens was investigated and it was shown that, based on the purpose of our imaging tasks, different numerical apertures must be used. The deformed beam cross section of the single-photon excitation source was corrected and the enhancement of the resolution and image quaUty was shown. Furthermore, the dependency of the scattered light on the excitation wavelength was shown empirically. In the second part, we continued the study of the image enhancement process by deconvolution techniques. Although deconvolution algorithms are used widely to improve the quality of the images, how well a deconvolution algorithm responds highly depends on the point spread function (PSF) of the imaging system applied to the algorithm and the level of its accuracy. We investigated approaches that can be done in order to obtain more precise PSF. Novel methods to improve the pattern of the PSF and reduce the noise are proposed. Furthermore, multiple soiu'ces to extract the PSFs of the imaging system are introduced and the empirical deconvolution results by using each of these PSFs are compared together. The results confirm that a greater improvement attained by applying the in situ PSF during the deconvolution process.
Resumo:
Flow injection analysis (FIA) was applied to the determination of both chloride ion and mercury in water. Conventional FIA was employed for the chloride study. Investigations of the Fe3 +/Hg(SCN)2/CI-,450 nm spectrophotometric system for chloride determination led to the discovery of an absorbance in the 250-260 nm region when Hg(SCN)2 and CI- are combined in solution, in the absence of iron(III). Employing an in-house FIA system, absorbance observed at 254 nm exhibited a linear relation from essentially 0 - 2000 Jlg ml- 1 injected chloride. This linear range spanning three orders of magnitude is superior to the Fe3+/Hg(SCN)2/CI- system currently employed by laboratories worldwide. The detection limit obtainable with the proposed method was determin~d to be 0.16 Jlg ml- 1 and the relative standard deviation was determined to be 3.5 % over the concentration range of 0-200 Jig ml- 1. Other halogen ions were found to interfere with chloride determination at 254 nm whereas cations did not interfere. This system was successfully applied to the determination of chloride ion in laboratory water. Sequential injection (SI)-FIA was employed for mercury determination in water with the PSA Galahad mercury amalgamation, and Merlin mercury fluorescence detection systems. Initial mercury in air determinations involved injections of mercury saturated air directly into the Galahad whereas mercury in water determinations involved solution delivery via peristaltic pump to a gas/liquid separator, after reduction by stannous chloride. A series of changes were made to the internal hardware and valving systems of the Galahad mercury preconcentrator. Sequential injection solution delivery replaced the continuous peristaltic pump system and computer control was implemented to control and integrate all aspects of solution delivery, sample preconcentration and signal processing. Detection limits currently obtainable with this system are 0.1 ng ml-1 HgO.
Resumo:
Modern computer systems are plagued with stability and security problems: applications lose data, web servers are hacked, and systems crash under heavy load. Many of these problems or anomalies arise from rare program behavior caused by attacks or errors. A substantial percentage of the web-based attacks are due to buffer overflows. Many methods have been devised to detect and prevent anomalous situations that arise from buffer overflows. The current state-of-art of anomaly detection systems is relatively primitive and mainly depend on static code checking to take care of buffer overflow attacks. For protection, Stack Guards and I-leap Guards are also used in wide varieties.This dissertation proposes an anomaly detection system, based on frequencies of system calls in the system call trace. System call traces represented as frequency sequences are profiled using sequence sets. A sequence set is identified by the starting sequence and frequencies of specific system calls. The deviations of the current input sequence from the corresponding normal profile in the frequency pattern of system calls is computed and expressed as an anomaly score. A simple Bayesian model is used for an accurate detection.Experimental results are reported which show that frequency of system calls represented using sequence sets, captures the normal behavior of programs under normal conditions of usage. This captured behavior allows the system to detect anomalies with a low rate of false positives. Data are presented which show that Bayesian Network on frequency variations responds effectively to induced buffer overflows. It can also help administrators to detect deviations in program flow introduced due to errors.
Resumo:
After skin cancer, breast cancer accounts for the second greatest number of cancer diagnoses in women. Currently the etiologies of breast cancer are unknown, and there is no generally accepted therapy for preventing it. Therefore, the best way to improve the prognosis for breast cancer is early detection and treatment. Computer aided detection systems (CAD) for detecting masses or micro-calcifications in mammograms have already been used and proven to be a potentially powerful tool , so the radiologists are attracted by the effectiveness of clinical application of CAD systems. Fractal geometry is well suited for describing the complex physiological structures that defy the traditional Euclidean geometry, which is based on smooth shapes. The major contribution of this research include the development of • A new fractal feature to accurately classify mammograms into normal and normal (i)With masses (benign or malignant) (ii) with microcalcifications (benign or malignant) • A novel fast fractal modeling method to identify the presence of microcalcifications by fractal modeling of mammograms and then subtracting the modeled image from the original mammogram. The performances of these methods were evaluated using different standard statistical analysis methods. The results obtained indicate that the developed methods are highly beneficial for assisting radiologists in making diagnostic decisions. The mammograms for the study were obtained from the two online databases namely, MIAS (Mammographic Image Analysis Society) and DDSM (Digital Database for Screening Mammography.
Resumo:
Mikrooptische Filter sind heutzutage in vielen Bereichen in der Telekommunikation unersetzlich. Wichtige Einsatzgebiete sind aber auch spektroskopische Systeme in der Medizin-, Prozess- und Umwelttechnik. Diese Arbeit befasst sich mit der Technologieentwicklung und Herstellung von luftspaltbasierenden, vertikal auf einem Substrat angeordneten, oberflächenmikromechanisch hergestellten Fabry-Perot-Filtern. Es werden zwei verschiedene Filtervarianten, basierend auf zwei verschiedenen Materialsystemen, ausführlich untersucht. Zum einen handelt es sich dabei um die Weiterentwicklung von kontinuierlich mikromechanisch durchstimmbaren InP / Luftspaltfiltern; zum anderen werden neuartige, kostengünstige Siliziumnitrid / Luftspaltfilter wissenschaftlich behandelt. Der Inhalt der Arbeit ist so gegliedert, dass nach einer Einleitung mit Vergleichen zu Arbeiten und Ergebnissen anderer Forschergruppen weltweit, zunächst einige theoretische Grundlagen zur Berechnung der spektralen Reflektivität und Transmission von beliebigen optischen Schichtanordnungen aufgezeigt werden. Auß erdem wird ein kurzer theoretischer Ü berblick zu wichtigen Eigenschaften von Fabry-Perot-Filtern sowie der Möglichkeit einer mikromechanischen Durchstimmbarkeit gegeben. Daran anschließ end folgt ein Kapitel, welches sich den grundlegenden technologischen Aspekten der Herstellung von luftspaltbasierenden Filtern widmet. Es wird ein Zusammenhang zu wichtigen Referenzarbeiten hergestellt, auf denen diverse Weiterentwicklungen dieser Arbeit basieren. Die beiden folgenden Kapitel erläutern dann ausführlich das Design, die Herstellung und die Charakterisierung der beiden oben erwähnten Filtervarianten. Abgesehen von der vorangehenden Epitaxie von InP / GaInAs Schichten, ist die Herstellung der InP / Luftspaltfilter komplett im Institut durchgeführt worden. Die Herstellungsschritte sind ausführlich in der Arbeit erläutert, wobei ein Schwerpunktthema das trockenchemische Ä tzen von InP sowie GaInAs, welches als Opferschichtmaterial für die Herstellung der Luftspalte genutzt wurde, behandelt. Im Verlauf der wissenschaftlichen Arbeit konnten sehr wichtige technische Verbesserungen entwickelt und eingesetzt werden, welche zu einer effizienteren technologischen Herstellung der Filter führten und in der vorliegenden Niederschrift ausführlich dokumentiert sind. Die hergestellten, für einen Einsatz in der optischen Telekommunikation entworfenen, elektrostatisch aktuierbaren Filter sind aus zwei luftspaltbasierenden Braggspiegeln aufgebaut, welche wiederum jeweils 3 InP-Schichten von (je nach Design) 357nm bzw. 367nm Dicke aufweisen. Die Filter bestehen aus im definierten Abstand parallel übereinander angeordneten Membranen, die über Verbindungsbrücken unterschiedlicher Anzahl und Länge an Haltepfosten befestigt sind. Da die mit 357nm bzw. 367nm vergleichsweise sehr dünnen Schichten freitragende Konstrukte mit bis zu 140 nm Länge bilden, aber trotzdem Positionsgenauigkeiten im nm-Bereich einhalten müssen, handelt es sich hierbei um sehr anspruchsvolle mikromechanische Bauelemente. Um den Einfluss der zahlreichen geometrischen Strukturparameter studieren zu können, wurden verschiedene laterale Filterdesigns implementiert. Mit den realisierten Filter konnte ein enorm weiter spektraler Abstimmbereich erzielt werden. Je nach lateralem Design wurden internationale Bestwerte für durchstimmbare Fabry-Perot-Filter von mehr als 140nm erreicht. Die Abstimmung konnte dabei kontinuierlich mit einer angelegten Spannung von nur wenigen Volt durchgeführt werden. Im Vergleich zu früher berichteten Ergebnissen konnten damit sowohl die Wellenlängenabstimmung als auch die dafür benötigte Abstimmungsspannung signifikant verbessert werden. Durch den hohen Brechungsindexkontrast und die geringe Schichtdicke zeigen die Filter ein vorteilhaftes, extrem weites Stopband in der Größ enordnung um 550nm. Die gewählten, sehr kurzen Kavitätslängen ermöglichen einen freien Spektralbereich des Filters welcher ebenfalls in diesen Größ enordnungen liegt, so dass ein weiter spektraler Einsatzbereich ermöglicht wird. Während der Arbeit zeigte sich, dass Verspannungen in den freitragenden InPSchichten die Funktionsweise der mikrooptischen Filter stark beeinflussen bzw. behindern. Insbesondere eine Unterätzung der Haltepfosten und die daraus resultierende Verbiegung der Ecken an denen sich die Verbindungsbrücken befinden, führte zu enormen vertikalen Membranverschiebungen, welche die Filtereigenschaften verändern. Um optimale Ergebnisse zu erreichen, muss eine weitere Verbesserung der Epitaxie erfolgen. Jedoch konnten durch den zusätzlichen Einsatz einer speziellen Schutzmaske die Unterätzung der Haltepfosten und damit starke vertikale Verformungen reduziert werden. Die aus der Verspannung resultierenden Verformungen und die Reaktion einzelner freistehender InP Schichten auf eine angelegte Gleich- oder Wechselspannung wurde detailliert untersucht. Mittels Weisslichtinterferometrie wurden lateral identische Strukturen verglichen, die aus unterschiedlich dicken InP-Schichten (357nm bzw. 1065nm) bestehen. Einen weiteren Hauptteil der Arbeit stellen Siliziumnitrid / Luftspaltfilter dar, welche auf einem neuen, im Rahmen dieser Dissertation entwickelten, technologischen Ansatz basieren. Die Filter bestehen aus zwei Braggspiegeln, die jeweils aus fünf 590nm dicken, freistehenden Siliziumnitridschichten aufgebaut sind und einem Abstand von 390nm untereinander aufweisen. Die Filter wurden auf Glassubstraten hergestellt. Der Herstellungsprozess ist jedoch auch mit vielen anderen Materialien oder Prozessen kompatibel, so dass z.B. eine Integration mit anderen Bauelemente relativ leicht möglich ist. Die Prozesse dieser ebenfalls oberflächenmikromechanisch hergestellten Filter wurden konsequent auf niedrige Herstellungskosten optimiert. Als Opferschichtmaterial wurde hier amorph abgeschiedenes Silizium verwendet. Der Herstellungsprozess beinhaltet die Abscheidung verspannungsoptimierter Schichten (Silizium und Siliziumnitrid) mittels PECVD, die laterale Strukturierung per reaktiven Ionenätzen mit den Gasen SF6 / CHF3 / Ar sowie Fotolack als Maske, die nasschemische Unterätzung der Opferschichten mittels KOH und das Kritisch-Punkt-Trocken der Proben. Die Ergebnisse der optischen Charakterisierung der Filter zeigen eine hohe Ü bereinstimmung zwischen den experimentell ermittelten Daten und den korrespondierenden theoretischen Modellrechnungen. Weisslichtinterferometermessungen der freigeätzten Strukturen zeigen ebene Filterschichten und bestätigen die hohe vertikale Positioniergenauigkeit, die mit diesem technologischen Ansatz erreicht werden kann.
Resumo:
Physikalische Grundlagenforschung und anwendungsorientierte physikalische Forschung auf den Gebieten nanoskaliger kristalliner und amorpher fester Körper haben in vielfacher Weise eine große Bedeutung. Neben dem Verständnis für die Struktur der Materie und die Wechselwirkung von Objekten von der Größe einiger Atome ist die Erkenntnis über die physikalischen Eigenschaften nanostrukturierter Systeme von hohem Interesse. Diese Forschung eröffnet die Möglichkeit, die mit der Mikroelektronik begonnene Miniaturisierung fortzusetzen und wird darüber hinaus neue Anwendungsfelder eröffnen. Das Erarbeiten der physikalischen Grundlagen der Methoden zur Herstellung und Strukturierung ist dabei zwingend notwendig, da hier Wirkungsprinzipien dominieren, die erst bei Strukturgrößen im Nanometerbereich auftreten oder hinreichend stark ausgeprägt sind. Insbesondere Halbleitermaterialien sind hier von großem Interesse. Die in dieser Arbeit untersuchten Resonatorstrukturen, die auf dem kristallinen Verbindungshalbleitermaterial GaInAsP/InP basieren, erschließen wichtige Anwendungsfelder im Bereich der optischen Datenübertragung sowie der optischen Sensorik. Hergestellt wird das Halbleitermaterial mit der Metallorganischen Gasphasenepitaxie. Die experimentell besimmten Kenngrößen lassen Rückschlüsse auf die Güte der Materialien, die quantenmechanischen Wirkungsprinzipien und die Bauelementcharakteristik zu und führen zu optimal angepassten Kristallstrukturen. Auf Basis dieser optimierten Materialien wurde ein durchstimmbarer Fabry-Perot-Filter hergestellt, der aus einer Kombination aus InP-Membranen und Luftspalten besteht und elektromechanisch aktuiert werden kann. Das GaInAsP dient hierbei als wenige hundert nm dicke Opferschicht, die ätztechnisch hochselektiv beseitigt wird. Die Qualität der Grenzflächen zum InP ist entscheidend für die Qualität der freigeätzten Kavitäten und damit für die mechanische Gesamtstabilität der Struktur. Der in dieser Arbeit beschriebene Filter hat eine Zentralwellenlänge im Bereich von 1550 nm und weist einen Durchstimmbereich von 221 nm auf. Erzielt wurde dieser Wert durch ein konsistentes Modell der wirkenden Verspannungskomponenten und einer optimierten epitaktischen Kontrolle der Verspannungsparameter. Das realisierte Filterbauelement ist vielversprechend für den Einsatz in der optischen Kommunikation im Bereich von WDM (wavelength division multiplexing) Anwendungen. Als weitere Resonatorstrukur wurde ein Asymmetrisch gekoppelter Quantenfilm als optisch aktives Medium, bestehend aus GaInAsP mit variierender Materialkomposition und Verspannung, untersucht, um sein Potential für eine breitbandige Emission zu untersuchen und mit bekannten Modellen zu vergleichen. Als Bauelementdesign wurde eine kantenemittierende Superlumineszenzleuchtdiode gewählt. Das Ergebnis ist eine Emissionskurve von 100 nm, die eine höhere Unabhängigkeit vom Injektionsstrom aufweist als andere bekannte Konzepte. Die quantenmechanischen Wirkungsprinzipien - im wesentlichen die Kopplung der beiden asymmetrischen Potentialtöpfe und die damit verbundene Kopplung der Wellenfunktionen - werden qualitativ diskutiert. Insgesamt bestätigt sich die Eignung des Materials GaInAsP auch für neuartige, qualitativ höchst anspruchsvolle Resonatorstrukturen und die Bedeutung der vorgestellten und untersuchten Resonatorkonzepte. Die vorgestellten Methoden, Materialien und Bauelemente liefern aufgrund ihrer Konzeption und der eingehenden experimentellen Untersuchungen einen Beitrag sowohl zu den zugrunde liegenden mechanischen, optoelektronischen und quantenmechanischen Wirkungsprinzipien der Strukturen, als auch zur Realisierung neuer optoelektronischer Bauelemente.
Resumo:
High-speed semiconductor lasers are an integral part in the implemen- tation of high-bit-rate optical communications systems. They are com- pact, rugged, reliable, long-lived, and relatively inexpensive sources of coherent light. Due to the very low attenuation window that exists in the silica based optical fiber at 1.55 μm and the zero dispersion point at 1.3 μm, they have become the mainstay of optical fiber com- munication systems. For the fabrication of lasers with gratings such as, distributed bragg reflector or distributed feedback lasers, etching is the most critical step. Etching defines the lateral dimmensions of the structure which determines the performance of optoelectronic devices. In this thesis studies and experiments were carried out about the exist- ing etching processes for InP and a novel dry etching process was de- veloped. The newly developed process was based on Cl2/CH4/H2/Ar chemistry and resulted in very smooth surfaces and vertical side walls. With this process the grating definition was significantly improved as compared to other technological developments in the respective field. A surface defined grating definition approach is used in this thesis work which does not require any re-growth steps and makes the whole fabrication process simpler and cost effective. Moreover, this grating fabrication process is fully compatible with nano-imprint lithography and can be used for high throughput low-cost manufacturing. With usual etching techniques reported before it is not possible to etch very deep because of aspect ratio dependent etching phenomenon where with increasing etch depth the etch rate slows down resulting in non-vertical side walls and footing effects. Although with our de- veloped process quite vertical side walls were achieved but footing was still a problem. To overcome the challenges related to grating defini- tion and deep etching, a completely new three step gas chopping dry etching process was developed. This was the very first time that a time multiplexed etching process for an InP based material system was demonstrated. The developed gas chopping process showed extra ordinary results including high mask selectivity of 15, moderate etch- ing rate, very vertical side walls and a record high aspect ratio of 41. Both the developed etching processes are completely compatible with nano imprint lithography and can be used for low-cost high-throughput fabrication. A large number of broad area laser, ridge waveguide laser, distributed feedback laser, distributed bragg reflector laser and coupled cavity in- jection grating lasers were fabricated using the developed one step etch- ing process. Very extensive characterization was done to optimize all the important design and fabrication parameters. The devices devel- oped have shown excellent performance with a very high side mode suppression ratio of more than 52 dB, an output power of 17 mW per facet, high efficiency of 0.15 W/A, stable operation over temperature and injected currents and a threshold current as low as 30 mA for almost 1 mm long device. A record high modulation bandwidth of 15 GHz with electron-photon resonance and open eye diagrams for 10 Gbps data transmission were also shown.
Resumo:
This paper describes a proposed new approach to the Computer Network Security Intrusion Detection Systems (NIDS) application domain knowledge processing focused on a topic map technology-enabled representation of features of the threat pattern space as well as the knowledge of situated efficacy of alternative candidate algorithms for pattern recognition within the NIDS domain. Thus an integrative knowledge representation framework for virtualisation, data intelligence and learning loop architecting in the NIDS domain is described together with specific aspects of its deployment.
Resumo:
A discharge-flow system, coupled to cavity-enhanced absorption spectroscopy (CEAS) detection systems for NO3 at lambda = 662 nm and NO2 at lambda = 404 nm, was used to investigate the kinetics of the reactions of NO3 with eight peroxy radicals at P similar to 5 Torr and T similar to 295 K. Values of the rate constants obtained were (k/10(-12) cm(3) molecule(-1) s(-1)): CH3O2 (1.1 +/- 0.5), C2H5O2 (2.3 +/- 0.7), CH2FO2 (1.4 +/- 0.9), CH2ClO2 (3.8(-2.6)(+1.4)), c-C5H9O2 (1.2(-0.5)(+1.1)), c-C6H11O2 (1.9 +/- 0.7), CF3O2 (0.62 +/- 0.17) and CF3CFO2CF3 (0.24 +/- 0.13). We explore possible relationships between k and the orbital energies of the reactants. We also provide a brief discussion of the potential impact of the reactions of NO3 with RO2 on the chemistry of the night-time atmosphere.