495 resultados para Neovascular glaucoma


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To compare the central corneal thickness (CCT) of patients with systemic sclerosis (SSc) and control subjects. Methods: The study group comprised 37 consecutive patients with SSc, and the control group comprised 23 healthy individuals similar in age and sex. CCT value was measured by ultrasound pachymetry. Results: In the SSc group, the mean CCT in the right eye was 534.9 +/- 33.5 mu m and 536.9 +/- 32.4 mu m in the left eye. In the control group, the mean CCT was 533.0 +/- 32.9 mu m in the right eye and 533.1 +/- 33.6 mu m in the left eye. The mean CCT was not significantly different in the SSc group compared with the control group for both the right (P = 0.83) and left (P = 0.67) eyes. Conclusions: CCT measurements do not significantly differ in patients with SSc compared with healthy control subjects.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To evaluate the additive effect of dorzolamide/timolol fixed combination in patients under monotherapy with latanoprost. Patients and Methods: In this prospective, 4-week, randomized, open-label controlled clinical trial, patients with open-angle glaucoma or ocular hypertension, which presented at least 15% intraocular pressure (IOP) reduction after a minimum period of 15 days of monotherapy with latanoprost and whose IOP level was considered above the established target-IOP level were randomized to receive fixed combination of timolol/dorzolamide twice daily in one of eyes. The fellow eye was kept under monotherapy and was included in the control group. A modified diurnal tension curve (mDTC) followed by the water drinking test were performed in the baseline and week 4 visits to evaluate IOP profile between groups. Results: Forty-nine per-protocol patients were analyzed. After latanoprost monotherapy run-in period, IOP levels were significantly reduced (P<0.001) in both control and study groups to 15.34 +/- 2.96 mm Hg and 15.24 +/- 2.84 mm Hg (30.8% and 32.2% IOP reduction, respectively; P=0.552). At week 4, mean baseline diurnal IOP levels were 15.60 +/- 3.09 and 14.44 +/- 3.03 (7.4% difference; P=0.01). Mean baseline IOP modified diurnal tension curve peak after latanoprost run-in period were 17.47 +/- 3.68 mm Hg and 17.02 +/- 3.35 mm Hg (control and study eyes, respectively; P=0.530). At week 4 visit, mean water-drinking test peaks were significantly reduced in the study eye group in comparison with the control group: 19.02 +/- 3.81 mm Hg and 20.39 +/- 4.19 mm Hg, respectively (6.7% reduction; P=0.039). Conclusions: In our sample, dorzolamide 2%/timolol 0.5% fixed combination as add-on therapy in patients with open-angle glaucoma or ocular hypertension under monotherapy with latanoprost with IOP already in mid-teens levels may further enhance pressure reduction.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

To evaluate the correlation between intraocular pressure (IOP) rise, ocular pulse amplitude (OPA), and choroidal thickness (ChT) during the water drinking test (WDT). Primary open-angle glaucoma (POAG) patients were submitted to the WDT followed by serial IOP measurements using dynamic contour tonometry (DCT), Goldman tonometry (GAT), and ChT measurements using ultrasonographic A and B-scan (USG). A control group not submitted to the test was also evaluated using DCT, GAT, and USG. Intraclass correlation coefficient (ICC) was calculated in the control group in order to assess the reproducibility of measurements. Spearman`s coefficient (rho) was used to assess the correlation between the variables. Thirty eyes were included in the study. There was a significant IOP rise during the WDT using both GAT and DCT (p < 0.001). The OPA and ChT measurements also increased significantly (p < 0.001). Spearman`s correlation between the OPA values and ChT measurements was significant and moderate (rho = 0.40, p = 0.005). The average increase of OPA and ChT measurements occurred 15 min before the IOP rise. There was a significant increase of OPA and ChT measurements followed by an IOP rise during the WDT. Increased choroidal volume due to hemodynamic forces may be enrolled in the mechanism of IOP elevation during this stress test.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To compare the ability of Subjective assessment of optic nerve head (ONH) and retinal nerve fiber layer (RNFL) by general ophthalmologists and by a glaucoma expert with objective measurements by optical coherence tomography (Stratus OCT, Carl Zeiss Meditec Inc), confocal scanning laser ophthalmoscope (HRT III; Heidelberg Engineering, Heidelberg. Germany), and scanning laser polarimetry (GDx enhanced corneal compensation; Carl Zeiss Meditec Inc, Dublin, CA) in discriminating glaucomatous and normal eyes. Methods: Sixty-one glaucomatous and 57 normal eyes or 118 subjects Were included in the study. Three independent general ophthalmologists and I glaucoma expert evaluated ONH stereo-photographs. Receiver operating characteristic curves were constructed for each imaging technique and sensitivity at fixed specificity was estimated. Comparisons or areas under these curves (aROCs) and agreement (k) were determined between stereophoto grading and best parameter from each technique. Results: Best parameter from each technique showed larger aROC (Stratus OCT RNFL 0.92; Stratus OCT ONH vertical integrated area = 0.86; Stratus OCT macular thickness = 0.82; GDx enhanced corneal compensation = 0.91, HRT3 global cup-to-disc ratio = 0.83; HRT3 glaucoma probability score numeric area score 0.83) compared with stereophotograph grading by general ophthalmologists (0.80) in separating glaucomatous and normal eyes. Glaucoma expert stereophoto grading provided equal or larger aROC (0.92) than best parameter of each computerized imaging device. Stereophoto evaluated by a glaucoma expert showed better agreement with best parameter of each quantitative imaging technique in classifying eyes either as glaucomatous or normal compared with stereophoto grading by general ophthalmologists, The combination Of Subjective assessment of the optic disc by general ophthalmologists with RNFL objective parameters improved identification of glaucoma patients in a larger proportion than the combination of these objective parameters with Subjective assessment of the optic disc by a glaucoma expert (29.5% vs. 19.7%, respectively). Conclusions: Diagnostic ability of all imaging techniques showed better performance than subjective assessment of the ONH by general ophthalmologists, but not by It glaucoma expert, Objective RNFL measurements may provide improvement in glaucoma detection when combined with subjective assessment of the optic disc by general ophthalmologists or by a glaucoma expert.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: To estimate the prevalence of blindness in the elderly population of Campinas, Brazil, and to describe the coverage and quality of cataract surgery services in the area. Methods: A brief assessment of cataract surgery services (using the RACSS (Rapid Assessment of Cataract Surgical Services Method) was conducted using random cluster sampling, with a sample composed of 60 clusters of 40 people aged 50 years or older. Visual acuity (VA) was measured and the lens status observed by direct visual ophthalmoscopy. From the selected sample of 2,400 subjects, 92.67% were examined. Results: Blindness (VA 3/60 with available correction) was found in 1.98 % (2.03 % among male subjects, and 1.94 % among female subjects). The prevalence of blindness varied with age, from 0.2%, in the group from 50 to 54 years, to 7.2% in those above 80. Cataract was the main cause of blindness (40.2%) followed by suspected posterior segment disorders (18.2%), diabetic retinopathy (15.9%), and glaucoma (11.4%). The cataract surgical coverage was of 93% (VA 3/60) and 82.18% when the criterion was VA 6/60 in the best eye. The main reasons the subjects did not receive surgical treatment were: fear of undergoing surgery, 11.1%; lack of awareness about the condition, 16.7%; waiting for maturity, 16.7%; and contraindication to surgery, 44.4%. Conclusion: Cataract is the major cause of blindness in Campinas. Education on eye diseases, their prevention and treatment must become part of the city`s public healthcare policies.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To compare the ability of Fourier-domain (FD) optical coherence tomography (3D OCT-1000; Top, con, Tokyo, Japan) and time domain (TD) OCT (Stratus; Carl Zeiss Meditec Inc, Dublin, California, USA) to detect axonal loss in eyes with band atrophy (BA) of the optic nerve. DESIGN: Cross-sectional study. METHODS: Thirty-six eyes from 36 patients with BA and temporal visual field (VF) defect from chiasmal compression and 36 normal eyes were studied. Subjects were submitted to standard automated perimetry and macular and retinal nerve fiber layer (RNFL) measurements were taken using 3D OCT-1000 and Stratus OCT. Receiver operating characteristic (ROC) curves were calculated for each parameter. Spearman correlation coefficients were obtained to evaluate the relationship between RNFL and macular thickness parameters and severity of VF loss. Measurements from the two devices were compared. RESULTS: Regardless of OCT device, all RNFL and macular thickness parameters were significantly lower in eyes with BA compared with normal eyes, but no statistically significant difference was found with regard to the area under the ROC curve. Structure-function relationships were also similar for the two devices. In both groups, RNFL and macular thickness measurements were generally and in some cases significantly smaller with 3D OCT-1000 than with Stratus OCT. CONCLUSIONS: The introduction of FD technology did not lead to better discrimination ability for detecting BA of the optic nerve compared with TD technology when using the software currently provided by the manufacturer. 3D OCT-1000 FD OCT RNFL and macular measurements were generally smaller than TD Stratus OCT measurements. Investigators should be aware of this fact when comparing measurements obtained with these two devices. (Am J Oplathalmol 2009;147: 56-63. (c) 2009 by Elsevier Inc. All rights reserved.)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To compare the efficacy and tolerability of the fixed combination of timolol maleate 0.5%/brimonidine tartrate 0.2% versus fixed combination of timolol maleate 0.5%/dorzolamide 2% in patients with elevated intraocular pressure (IOP) over 8 weeks. Patients and Methods: This 8-week, multicentric. interventional, randomized, open-label, parallel group study was conducted Lit 4 centers in Brazil and 1 center in Argentina. Patients with open-angle glaucoma or ocular hypertension were randomized to receive bilaterally fixed combination of brimonidine/timolol maleate 0.5% or fixed combination of dorzolamide 2%/timolol 0.5% twice daily at 8:00 AM and 8:00 PM. A modified diurnal tension curve (8:00 AM 10:30 AM, 02:00 PM, and 4:00 PM) followed by the water drinking test (WDT), which estimates IOP peak of diurnal tension curve, were performed in the baseline and week-8 visits. Adverse events data were recorded at each visit. Results: A total of 210 patients were randomized (brimonidine/timolol, n = 111; dorzolamide/timolol, n = 99). Mean baseline IOP was 23.43 +/- 3.22 mm Hg and 23.43 +/- 4.06 mm Hg in the patients treated with brimonidine/timolol and dorzolamide/timolol, respectively (P = 0.993). Mean diurnal IOP reduction after 8 weeks were 7.02 +/- 3.06 mm Hg and 6.91 +/- 3.67 mm Hg. respectively (P = 0.811). The adjusted difference between groups (analysis of covariance) Lit week 8 was not statistically significant (P = 0.847). Mean baseline WDT peak was 27.79 +/- 4.29 mm Hg in the brimonidine/timolol group and 27.68 +/- 5.46 mm Hg in the dorzolamide/timolol group. After 8 weeks of treatment, mean WDT peaks were 20.94 +/- 3.76 mm Hg (P < 0.001) and 20.98 +/- 4.19 (P < 0.001), respectively. The adjusted difference between groups (analysis of covariance) was not statistically significant (P = 0.469). No statistical difference in terms of adverse events was Found between groups. Conclusions: Both fixed combinations were capable of significantly reducing the mean diurnal IOP, mean diurnal peak, and mean WDT peak after 8 weeks of treatment. Also, both fixed combinations are well tolerated with few side effects.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

to test the ability of frequency-doubling technology (FDT) perimetry to detect dysthyroid optic neuropathy (DON). Fifteen eyes of 15 patients with DON and 15 healthy control eyes were studied. Eligible eyes had a diagnosis of DON based on visual field abnormalities on standard automated perimetry and had visual acuity better than 20/30. FDT testing was performed using both the C-20-5 screening test and the C-20 full-threshold test. Normal and DON eyes were compared with regard to FDT mean sensitivity. Sensitivity ranges were 40.0%-86.7% for the screening test, and 53.3%-100.0% (total deviation) and 20.0-93.3 (pattern deviation) for the C-20 threshold test. The corresponding specificity ranges were 86.7-100.0, 33.3-93.3, and 26.7-100.0, respectively. The best sensitivity/specificity ratios were for one abnormal point depressed < 5% in the screening test (86.7%/86.7%), one point depressed < 1% in the total deviation analysis (80.0%/86.7%), and one point depressed < 2% in the pattern deviation analysis (80.0%/86.7%). DON eyes presented significantly lower than normal average sensitivity in the central, pericentral, and peripheral areas. FDT perimetry is a useful screening tool for DON in eyes with normal or only slightly reduced visual acuity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aim To compare the ability of scanning laser polarimeter (SLP) with variable corneal compensation (GDx VCC) and optical coherence tomograph (Stratus OCT) to discriminate between eyes with band atrophy (BA) of the optic nerve and healthy eyes. Methods The study included 37 eyes with BA and temporal visual field (VF) defects from chiasmal compression, and 29 normal eyes. Subjects underwent standard automated perimetry (SAP) and retinal nerve fibre layer (RNFL) scans using GDx VCC and Stratus OCT. The severity of the VF defects was evaluated by the temporal mean defect (TMD), calculated as the average of 22 values of the temporal total deviation plot on SAP. Receiver operating characteristic (ROC) curves were calculated. Pearson`s correlation coefficients were used to evaluate the relationship between RNFL thickness parameters and the TMD. Results No significant difference was found between the ROC curves areas (AUCs) for the GDx VCC and Stratus OCT with regard to average RNFL thickness (0.98 and 0.99, respectively) and the superior (0.94; 0.95), inferior (0.96; 0.97), and nasal (0.92; 0.96) quadrants. However, the AUC in the temporal quadrant (0.77) was significantly smaller (P < 0.001) with GDx VCC than with Stratus OCT (0.98). Lower TMD values were associated with smaller RNFL thickness in most parameters from both equipments. Conclusion Adding VCC resulted in improved performance in SLP when evaluating eyes with BA, and both technologies are sensitive in detecting average, superior, inferior, and nasal quadrant RNFL loss. However, GDx VCC still poorly discriminates RNFL loss in the temporal quadrant when compared with Stratus OCT.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To evaluate rates of visual field progression in eyes with optic disc hemorrhages and the effect of intraocular pressure (IOP) reduction on these rates. Design: Observational cohort study. Participants: The study included 510 eyes of 348 patients with glaucoma who were recruited from the Diagnostic Innovations in Glaucoma Study (DIGS) and followed for an average of 8.2 years. Methods: Eyes were followed annually with clinical examination, standard automated perimetry visual fields, and optic disc stereophotographs. The presence of optic disc hemorrhages was determined on the basis of masked evaluation of optic disc stereophotographs. Evaluation of rates of visual field change during follow-up was performed using the visual field index (VFI). Main Outcome Measures: The evaluation of the effect of optic disc hemorrhages on rates of visual field progression was performed using random coefficient models. Estimates of rates of change for individual eyes were obtained by best linear unbiased prediction (BLUP). Results: During follow-up, 97 (19%) of the eyes had at least 1 episode of disc hemorrhage. The overall rate of VFI change in eyes with hemorrhages was significantly faster than in eyes without hemorrhages (-0.88%/year vs. -0.38%/year, respectively, P < 0.001). The difference in rates of visual field loss pre- and post-hemorrhage was significantly related to the reduction of IOP in the post-hemorrhage period compared with the pre-hemorrhage period (r = -0.61; P < 0.001). Each 1 mmHg of IOP reduction was associated with a difference of 0.31%/year in the rate of VFI change. Conclusions: There was a beneficial effect of treatment in slowing rates of progressive visual field loss in eyes with optic disc hemorrhage. Further research should elucidate the reasons why some patients with hemorrhages respond well to IOP reduction and others seem to continue to progress despite a significant reduction in IOP levels. Financial Disclosure(s): Proprietary or commercial disclosure may be found after the references. Ophthalmology 2010; 117: 2061-2066 (C) 2010 by the American Academy of Ophthalmology.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE. To evaluate the relationship between pattern electroretinogram (PERG) amplitude, macular and retinal nerve fiber layer (RNFL) thickness by optical coherence tomography (OCT), and visual field (VF) loss on standard automated perimetry (SAP) in eyes with temporal hemianopia from chiasmal compression. METHODS. Forty-one eyes from 41 patients with permanent temporal VF defects from chiasmal compression and 41 healthy subjects underwent transient full-field and hemifield (temporal or nasal) stimulation PERG, SAP and time domain-OCT macular and RNFL thickness measurements. Comparisons were made using Student`s t-test. Deviation from normal VF sensitivity for the central 18 of VF was expressed in 1/Lambert units. Correlations between measurements were verified by linear regression analysis. RESULTS. PERG and OCT measurements were significantly lower in eyes with temporal hemianopia than in normal eyes. A significant correlation was found between VF sensitivity loss and fullfield or nasal, but not temporal, hemifield PERG amplitude. Likewise a significant correlation was found between VF sensitivity loss and most OCT parameters. No significant correlation was observed between OCT and PERG parameters, except for nasal hemifield amplitude. A significant correlation was observed between several macular and RNFL thickness parameters. CONCLUSIONS. In patients with chiasmal compression, PERG amplitude and OCT thickness measurements were significant related to VF loss, but not to each other. OCT and PERG quantify neuronal loss differently, but both technologies are useful in understanding structure-function relationship in patients with chiasmal compression. (ClinicalTrials.gov number, NCT00553761.) (Invest Ophthalmol Vis Sci. 2009; 50: 3535-3541) DOI:10.1167/iovs.08-3093

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: Subclinical inflammation may be observed in patients, using topical antiglaucomatous drugs. The objective,e of this study was to investigate inflammation in conjunctiva of glaucoma patients using prostaglandin analogs, by the detection of a immunogenetic marker (HLA-DR) and compare the effect of 3 different drugs: latanoprost, bimatoprost, and travoprost in the induction of this inflammation. Subjects and Methods: Thirty-three patients with primary open-angle glaucoma were evaluated without and with prostaglandin analogs topical therapy. Imprints of conjunctival cells were obtained, fixed on glass slides. and Prepared for immunohistochemical analysis. Results: Before the use of prostaglandin analogs, 4 of the 33 patients evaluated presented expression (of HLA-DR in the conjunctiva (mild). After 1 month oil prostaglandin analog treatment, all but 1 patient presented HLA-DR staining. HLA-DR expression of these 32 patients was scored as mild (19 patients), medium (11 patients), or intense (2 patients). The differences were statistically significant both when the presence and the increased expression of HLA-DR were considered (P<0.001). When the 3 different groups were analyzed (latanoprost, bimatoprost, and travoprost) no statistically significant difference was round (P 0.27). Conclusions: The use of prostaglandin analogs eye drops provokes, a reaction, observed by HLA-DR subclinical inflammatory expression, even after a short period of treatment, independently of the class of the prostaglandin analogs used.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To describe periorbital changes induced by chronic topical therapy with daily bimatoprost 0.03% (Lumigan, Allergan Inc., Irvine, CA, U.S.A.). Methods: A clinical investigation of 5 nonconsecutive patients with unilateral glaucoma treated daily with topical bimatoprost 0.03% for up to 4 years prior to presentation. Results: In eyes treated with bimatoprost 0.03% the authors noted periorbital fat atrophy, deepening of the upper eyelid sulcus, relative enophthalmos, loss of the lower eyelid fullness, and involution of dermatochalasis compared with the fellow untreated eye. By inspecting old photographs the authors confirmed that these unilateral changes were not present prior to starting bimatoprost. In addition, these changes were partially reversible after discontinuation of the medication, whenever that was possible. In 2 cases imaging studies confirmed the clinical impression that these findings were not related to primary orbital pathology. Conclusions: Physicians and patients should be aware of the potential of bimatoprost 0.03% to produce periorbital changes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Glutamate is the major excitatory neurotransmitter in the retina and is removed from the extracellular space by an energy-dependent process involving neuronal and glial cell transporters. The radial glial Muller cells express the glutamate transporter, GLAST, and preferentially accumulate glutamate. However, during an ischaemic episode, extracellular glutamate concentrations may rise to excitotoxic levels. Is this catastrophic rise in extracellular glutamate due to a failure of GLAST? Using immunocytochemistry, we monitored the transport of the glutamate transporter substrate, D-aspartate, in the retina under normal and ischaemic conditions. Two models of compromised retinal perfusion were compared: (1) Anaesthetised rats had their carotid arteries occluded for 7 days to produce a chronic reduction in retinal blood flow. Retinal function was assessed by electroretinography. D-aspartate was injected into the eye for 45 min, Following euthanasia, the retina was processed for D-aspartate. GLAST and glutamate immunocytochemistry. Although reduced retinal perfusion suppresses the electroretinogram b-wave, neither retinal histology, GLAST expression, nor the ability of Muller cells to uptake D-aspartate is affected. As this insult does not appear to cause excitotoxic neuronal damage, these data suggest that GLAST function and glutamate clearance are maintained during periods of reduced retinal perfusion. (2) Occlusion of the central retinal artery for 60 min abolishes retinal perfusion, inducing histological damage and electroretinogram suppression. Although GLAST expression appears to be normal. its ability to transport D-aspartate into Muller cells is greatly reduced. Interestingly, D-aspartate is transported into neuronal cells, i.e. photoreceptors, bipolar and ganglion cells. This suggests that while GLAST is vitally important for the clearance of excess extracellular glutamate, its capability to sustain inward transport is particularly susceptible to an acute ischaemic attack. Manipulation of GLAST function could alleviate the degeneration and blindness that result from ischaemic retinal disease. (C) 2001 Elsevier Science Ltd, All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

1. Eight human cytochrome P4501B1 (CYP1B1) allelic variants, namely Arg(48)Ala(119)Leu(432), Arg(48)Ala(119)Val(432), Gly(48)Ala(119)Leu(432), Gly(48)Ala(119)Val(432), Arg(48)Ser(119)Leu(432), Arg(48)Ser(119)Val(432), Gly(48)Ser(119)Leu(432) and Gly(48)Ser(119)Val(432) (all with Asn(453)), were expressed in Escherichia coli together with human NADPH-P450 reductase and their catalytic specificities towards oxidation of 17 beta -oestradiol and benzo[a]pyrene were determined. 2. All of the CYP1B1 variants expressed in bacterial membranes showed Fe2+. CO versus Fe2+ difference spectra with wavelength maxima at 446 nm and they reacted with antibodies raised against recombinant human CYP1B1 in immunoblots. The ratio of expression of the reductase to CYP1B1 in these eight preparations ranged from 0.2 to 0.5. 3. CYP1B1 Arg(48) variants tended to have higher activities for 17 beta -oestradiol 4-hydroxylation than Gly(48) variants, although there were no significant variations in 17 beta -oestradiol 2-hydroxylation activity in these eight CYP1B1 variants. Interestingly, ratios of formation of 17 beta -oestradiol 4-hydroxylation to 2-hydroxylation by these CYP1B1 variants were higher in all of the Val(432) forms than the corresponding Leu(432) forms. 4. In contrast, Leu(432) forms of CYP1B1 showed higher rates of oxidation of benzo[a]pyrene (to the 7, 8-dihydoxy-7,8-dihydrodiol in the presence of epoxide hydrolase) than did the Val(432) forms. 5. These results suggest that polymorphic human CYP1B1 variants may cause some altered catalytic specificity with 17 beta -oestradiol and benzo[a]pyrene and may influence susceptibilities of individuals towards endogenous and exogenous carcinogens.