987 resultados para MEDICAL IMAGING
Resumo:
Purpose We quantified variations of the lingual artery origin, measured the lingual artery origin distance from clinical relevant landmarks and compared the lingual artery diameters with normal and variable origin. Methods Forty-two formalin fixed male cadavers were bilaterally evaluated. Measurements were performed with the aid of an electronic digital caliper. Results The origin distances from the common carotid artery bifurcation was 1.05 +/- 0.11 and 1.02 +/- 0.11 cm for the right and left lingual arteries respectively with no differences compared to the lingual-facial trunks. The diameters of the lingual arteries were 0.25 +/- 0.01 and 0.26 +/- 0.01 cm for the right and left sides, respectively, while the lingual facial trunks showed diameters of 0.21 +/- 0.02 and 0.24 +/- 0.02 cm for the right and left sides, respectively. Conclusions The present study adds information on the lingual artery diameter and its anatomical relation to clinically useful landmarks.
Resumo:
Objective Intrasubstance meniscal signal changes not reaching the articular surface on fast spin echo (FSE) sequences are considered to represent mucoid degeneration on MRI. The aim of this study was to evaluate the association of prevalent intrasubstance signal changes with incident tears of the medial meniscus detected on 3.0 T MRI over a 1-year period. Materials and methods A total of 161 women aged a parts per thousand yen40 years participated in a longitudinal 1-year observational study of knee osteoarthritis. MRI (3.0 T) was performed at baseline and 12-month follow-up. The anterior horn, body, and posterior horn of the medial meniscus were scored by two experienced musculoskeletal radiologists using the Boston-Leeds Osteoarthritis Knee Score (BLOKS) system. Four grades were used to describe the meniscal morphology: grade 0 (normal), grade 1 (intrasubstance signal changes not reaching the articular surface), grade 2 (single tears), and grade 3 (complex tears and maceration). Fisher`s exact test and the Cochran-Armitage trend test were performed to evaluate whether baseline intrasubstance signal changes (grade 1) predict incident meniscal tears/maceration (grades 2 and/or 3) in the same subregion of the medial meniscus, when compared to subregions without pathology as the reference group (grade 0). Results Medial meniscal intrasubstance signal changes at baseline did not predict tears at follow-up when evaluating the anterior and posterior horns (left-sided p-values 0.06 and 0.59, respectively). No incident tears were detected in the body. Conclusion We could not demonstrate an association between prevalent medial meniscal intrasubstance signal changes with incident tears over a 1-year period.
Resumo:
Objective. The purpose of this study was to evaluate the diagnostic usefulness of ulnar nerve sonography in leprosy neuropathy with electrophysiologic correlation. Methods. Twenty-one consecutive patients with leprosy (12 men and 9 women; mean age +/- SD, 47.7 +/- 17.2 years) and 20 control participants (14 men and 6 women; mean age, 46.5 +/- 16.2 years) were evaluated with sonography. Leprosy diagnosis was established on the basis of clinical, bacteriologic, and histopathologic criteria. The reference standard for ulnar neuropathy in this study was clinical symptoms in patients with proven leprosy The sonographic cross-sectional areas (CSAs) of the ulnar nerve in 3 different regions were obtained. Statistical analyses included Student t tests and receiver operating characteristic curve analysis. Results. The CSAs of the ulnar nerve were significantly larger in the leprosy group than the control group for all regions (P < .01). Sonographic abnormalities in leprosy nerves included focal thickening (90.5%), hypoechoic areas (81%), loss of the fascicular pattern (33.3%), and focal hyperechoic areas (4.7%). Receiver operating characteristic curve analysis showed that a maximum CSA cutoff value of 9.8 mm(2) was the best discriminator (sensitivity, 0.91; specificity, 0.90). Three patients with normal electrophysiologic findings had abnormal sonographic findings. Two patients had normal sonographic findings, of which 1 had abnormal electrophysiologic findings, and the other refused electrophysiologic testing. Conclusions. Sonography and electrophysiology were complementary for identifying ulnar nerve neuropathy in patients with leprosy, with clinical symptoms as the reference standard. This reinforces the role of sonography in the investigation of leprosy ulnar neuropathy.
Resumo:
BACKGROUND AND PURPOSE: There are 2 main hypotheses concerning the cause of mirror movements (MM) in Kallmann syndrome (KS): abnormal development of the primary motor system, involving the ipsilateral corticospinal tract, and lack of contralateral motor cortex inhibitory mechanisms, mainly through the corpus callosum. The purpose of our study was to determine white and gray matter volume changes in a KS population by using optimized voxel-based morphometry (VBM) and to investigate the relationship between the abnormalities and the presence of MM, addressing the 2 mentioned hypotheses. MATERIALS AND METHODS: T1-weighted volumetric images from 21 patients with KS and 16 matched control subjects were analyzed with optimized VBM. Images were segmented and spatially normalized, and these deformation parameters were then applied to the original images before the second segmentation. Patients were divided into groups with and without MM, and a t test statistic was then applied on a voxel-by-voxel basis between the groups and controls to evaluate significant differences. RESULTS: When considering our hypothesis a priori, we found that 2 areas of increased gray matter volume, in the left primary motor and sensorimotor cortex, were demonstrated only in patients with MM, when compared with healthy controls. Regarding white matter alterations, no areas of altered volume involving the corpus callosum or the projection of the corticospinal tract were demonstrated. CONCLUSION: The VBM study did not show significant white matter changes in patients with KS but showed gray matter alterations in keeping with a hypertrophic response to a deficient pyramidal decussation in patients with MM. In addition, gray matter alterations were observed in patients without MM, which can represent more complex mechanisms determining the presence or absence of this symptom.
Resumo:
Purpose To describe the ictal technetium-99 m-ECD SPECT findings in polymicrogyria syndromes (PMG) during epileptic seizures. Methods We investigated 17 patients with PMG syndromes during presurgical workup, which included long-term video-electroencephalographic (EEG) monitoring, neurological and psychiatry assessments, invasive EEG, and the subtraction of ictal-interictal SPECT coregistered to magnetic resonance imaging (MRI) (SISCOM). Results The analysis of the PMG cortex, using SISCOM, revealed intense hyperperfusion in the polymicrogyric lesion during epileptic seizures in all patients. Interestingly, other localizing investigations showed heterogeneous findings. Twelve patients underwent epilepsy surgery, three achieved seizure-freedom, five have worthwhile improvement, and four patients remained unchanged. Conclusions Our study strongly suggests the involvement of PMG in seizure generation or early propagation. Both conventional ictal single-photon emission computed tomography (SPECT) and SISCOM appeared as the single contributive exam to suggest the localization of the epileptogenic zone. Despite the limited number of resective epilepsy surgery in our study (n=9), we found a strong prognostic role of SISCOM in predicting surgical outcome. This result may be of great value on surgical decision-making of whether or not the whole or part of the PMG lesion should be surgically resected.
Resumo:
Purpose: To describe the use of 3.0-T magnetic resonance imaging (MRI) for the evaluation of chronic liver diseases. Materials and Methods: Two groups of patients who had chronic liver diseases and underwent 3.0-T MRI for evaluation of the liver were included in the study. The first group of patients included 66 consecutive patients (33 male, 33 female; mean age +/- standard deviation, 56 +/- 11). The second group of patients included 30 consecutive patients (18 males, 12 females; mean age +/- standard deviation, 53 +/- 10) in whom Variable-Rate Selective Excitation (VERSE) pulses and improved adjustments procedure were used during the acquisitions. Imaging findings of chronic liver diseases, predetermined artifacts and image quality of all individual sequences in the first group and predetermined artifacts and image quality of T2-weighted sequences in the second group were reviewed retrospectively and independently by two reviewers. chi-Square tests were used to compare the findings between two groups of patients and individual sequences. Kappa statistics were used to determine the extent of agreement between the reviewers. Results: Fifteen dysplastic nodules in 6 of 66 (9%) patients and 12 hepatocellular carcinomas in 11 of 66 (17%) patients were detected. Excluding motion artifacts, three-dimensional (313) T1-weighted gradient-echo (GE) sequence was the least affected sequence by the artifacts. Image quality of T1-weighted 3D-GE sequences was excellent in 43 of 66 (65%) patients. In-phase and out-of-phase T1-weighted spoiled GE (SGE) images were fair in 62 of 66 (94%) and 61 of 66 (92%) patients, respectively. The image quality of short tau inversion recovery (STIR) and half-Fourier rapid acquisition with relaxation enhancement (RARE) sequences were fair in 31 of 66 (47%) and 53 of 66 (80%) patients. STIR and half-Fourier RARE sequences in the second group demonstrated significantly better image quality (P=.03 and P<.0001). Conclusion: 3.0-T MRI allows the acquisition of very high quality postgadolinium 3D-GE sequence, which permitted the detection and characterization of lesions in the setting of chronic liver diseases. The use of VERSE pulses and improved adjustments procedure improved the image quality of T2-weighted sequences. In-phase/out-of-phase SGE sequences are at present of fair quality. (C) 2008 Elsevier Inc. All rights reserved.
Resumo:
In this paper, methods are presented for automatic detection of the nipple and the pectoral muscle edge in mammograms via image processing in the Radon domain. Radon-domain information was used for the detection of straight-line candidates with high gradient. The longest straight-line candidate was used to identify the pectoral muscle edge. The nipple was detected as the convergence point of breast tissue components, indicated by the largest response in the Radon domain. Percentages of false-positive (FP) and false-negative (FN) areas were determined by comparing the areas of the pectoral muscle regions delimited manually by a radiologist and by the proposed method applied to 540 mediolateral-oblique (MLO) mammographic images. The average FP and FN were 8.99% and 9.13%, respectively. In the detection of the nipple, an average error of 7.4 mm was obtained with reference to the nipple as identified by a radiologist on 1,080 mammographic images (540 MLO and 540 craniocaudal views).
Resumo:
Cardiac sympathetic denervation and ventricular arrhythmia are frequently observed in chronic Chagas cardiomyopathy (CCC). This study quantitatively evaluated the association between cardiac sympathetic denervation and sustained ventricular tachycardia (SVT) in patients with CCC. Methods: We prospectively investigated patients with CCC and left ventricular ejection fraction (LVEF) greater than 35% with SVT (SVT group: n = 5 15; mean age +/- SD, 61 +/- 8 y; LVEF, 51% +/- 8%) and patients without SVT (non-SVT group: n = 11; mean age +/- SD, 55 +/- 10 y; LVEF, 57% +/- 10%). Patients underwent myocardial scintigraphy with (123)I-metaiodobenzylguanidine ((123)I-MIBG) for the evaluation of sympathetic innervation and resting perfusion with (99m)Tc-methoxyisobutylisonitrile ((99m)Tc-MIBI) for the evaluation of myocardial viability. A visual semiquantitative score was attributed for regional uptake of each radiotracer using a 17-segment left ventricular segmentation model (0, normal; 4, absence of uptake). A mismatch defect was defined as occurring in segments with a 99mTc-MIBI uptake score of 0 or 1 and a (123)I-MIBG score of 2 or more. Results: Compared with the non-SVT group, the SVT group had a similar (99m)Tc-MIBI summed score (6.9 +/- 7.5 vs. 4.4 +/- 5.2, respectively, P = 0.69) but a higher (123)I-MIBG summed score (10.9 +/- 7.8 vs. 22.4 +/- 9.5, respectively, P = 0.007) and a higher number of mismatch defects per patient (2.0 +/- 2.2 vs. 7.1 +/- 2.0, respectively, P < 0.0001). The presence of more than 3 mismatch defects was strongly associated with the presence of SVT (93% sensitivity, 82% specificity; P = 0.0002). Conclusion: In CCC, the amount of sympathetically denervated viable myocardium is associated with the occurrence of SVT. Myocardial sympathetic denervation may participate in triggering malignant ventricular arrhythmia in CCC patients with relatively well-preserved ventricular function.
Resumo:
Prostatic stromal tumours are rare neoplasias that include benign, malignant and borderline lesions. Stromal tumour of uncertain malignant potential (STUMP) has been recently described and only a few reports exist in the literature. As a rare and distinct neoplasia, to date, there is no description of MRI findings of prostate STUMP. In this article, we describe the clinical and MRI features with histopathological correlation of a patient with prostate STUMP.
Resumo:
We evaluated 16 pregnant women with gestational age between 20 and 32 weeks in acute severe hypertension which were randomly allocated to receive either hydralazine or labetalol. Blood pressure and Doppler ultrasound parameters from maternal uterine and fetal middle cerebral and umbilical arteries were assessed during acute severe hypertension and after treatment. A significant reduction in systolic and diastolic blood pressure was observed in both groups. A significant change in Doppler parameters was observed only in pregnant women who received hydralazine: an increase in uterine arteries resistance index. We concluded that both drugs were highly effective in reducing blood pressure in these women. Despite the observed increase in resistance index of uterine arteries associated with hydralazine, the use of hydralazine and labetalol were not related to any significant changes in fetal Doppler, which is reassuring about the safety of these drugs when treating acute severe hypertension in pregnancy. (E-mail: wpmartins@gmail.com) (C) 2011 World Federation for Ultrasound in Medicine & Biology.
Resumo:
We aim to evaluate intra- and interobserver reproducibility of brachial artery flow-mediated dilation (FMD) and of pulsatility index change (PI-C) 1 min after a 5-min forearm compression in pregnant women. Flow-mediated dilation and PI-C were assessed in 31 healthy pregnant women in 3 consecutive days, by two observers. A broader range of response to the stimulus was observed for PI-C (-58.99%-86.71%) than FMD (2.38%-27.01%). The intraclass correlation coefficients were higher for PI-C than for FMD (intra = 0.90 vs. 0.69, p = 0.047; inter = 0.94 vs. 0.61, p = 0.007). Therefore, PI-C measurements were more reliable than FMD. However, studies comprising of subjects with cardiovascular risk factors relating FMD and PI-C become necessary to validate this method for the study of endothelial dysfunction. (E-mail: wpmartins@gmail.com) (C) 2010 World Federation for Ultrasound in Medicine & Biology.
Resumo:
The aim of this study was to establish normal ranges of blood flow velocities and indices in the fetal ductus venosus (DV) during the second half of normal pregnancy. A Doppler study of 60 healthy pregnant women without fetal pathologies was performed during the second half of pregnancy. The peak systolic velocity (PSV), peak diastolic velocity (PDV), maximum velocity during atrial contraction (VAC), peak systolic velocity/maximum velocity during atrial contraction (S/A ratio), pulsatility index for the vein (PIV), preload index (PLI) and velocity index for the vein (VIV) were calculated from the DV at 4-week intervals. A significant increase in PSV, PDV and VAC was observed from the 20-23(6/7) to the 28-31(6/7) weeks, with stabilization of values until the end of the pregnancy. On the other hand, the study showed a significant decrease for the S/A ratio, PIV, PLI and VIV from the 20-23(6/7) to the 28-31(6/7) weeks and remaining stable from then until term. (E-mail:dralemar@uol.com.br) (C) 2010 World Federation for Ultrasound in Medicine & Biology.
Resumo:
Objectives To evaluate the presence of false flow three-dimensional (3D) power Doppler signals in `flow-free` models. Methods 3D power Doppler datasets were acquired from three different flow-free phantoms (muscle, air and water) with two different transducers and Virtual Organ Computer-aided AnaLysis was used to generate a sphere that was serially applied through the 3D dataset. The vascularization flow index was used to compare artifactual signals at different depths (from 0 to 6 cm) within the different phantoms and at different gain and pulse repetition frequency (PR F) settings. Results Artifactual Doppler signals were seen in all phantoms despite these being flow-free. The pattern was very similar and the degree of artifact appeared to be dependent on the gain and distance from the transducer. False signals were more evident in the far field and increased as the gain was increased, with false signals first appearing with a gain of 1 dB in the air and muscle phantoms. False signals were seen at a lower gain with the water phantom (-15 dB) and these were associated with vertical lines of Doppler artifact that were related to PRF, and disappeared when reflections were attenuated. Conclusions Artifactual Doppler signals are seen in flow-free phantoms and are related to the gain settings and the distance from the transducer. In the in-vivo situation, the lowest gain settings that allow the detection of blood flow and adequate definition of vessel architecture should be used, which invariably means using a setting near or below the middle of the range available. Additionally, observers should be aware of vertical lines when evaluating cystic or liquid-containing structures. Copyright (C) 2010 ISUOC. Published by John Wiley & Sons, Ltd.
Resumo:
Objective To investigate whether standardization of the multiplanar view (SMV) when evaluating the uterus using three-dimensional ultrasonography (3D-US) improves intra-and interobserver reliability and agreement with regard to endometrial measurement. Methods Two-dimensional (2D) and 3D-US was used to measure endometrial thickness by two observers in 30 women undergoing assisted reproduction treatment. Endometrial volume was measured with Virtual Organ Computer-aided AnaLysis (VOCAL (TM)) in the longitudinal (A) and coronal (C) planes using an unmodified multiplanar view (UMV) and a standardized multiplanar view (SMV). Measurement reliability was evaluated by intraclass correlation coefficient (ICC) and agreement was examined using Bland-Altman plots with limits of agreement (LoA). The ease of outlining the endometrial-myometrial interface was compared between the A-and C-planes using subjective assessment. Results Endometrial volume measurements using the SMV and A-plane were more reliable (intra-and interobserver ICCs, 0.979 and 0.975, respectively) than were measurements of endometrial thickness using 2D-US (intra-and interobserver ICCs, 0.742 and 0.702, respectively) or 3D-US (intra-and interobserver ICCs, 0.890 and 0.784, respectively). The LoAs were narrower for SMV than for UMV. Reliability and agreement were not much different between the A- and C-planes. However the observers agreed that delineating the endometrial-myometrial interface using the A-plane was easier (first and second observer, 50.0 and 46.7%, respectively) or `comparable` (50 and 53.3%, respectively), but never more difficult than using the C-plane. Conclusions Endometrial volume measurements are more reliable than endometrial thickness measurements and are best performed using SMV and the A-plane. Copyright (C) 2011 ISUOG. Published by John Wiley & Sons, Ltd.
Resumo:
We compared the effects of levonorgestrel-releasing intrauterine devices (LNG-IUD) and a gonadotropin-releasing hormone agonist (GnRHa) on uterine volume, uterine arteries pulsatility index (PI) and endometrial thickness before and after six months of endometriosis treatment. Sixty women aged 18-40 y were allocated randomly to one of two groups: LNG-IUDs were inserted in 30 women, and GnRHa monthly injections were performed on the other 30. All 60 women were submitted to transvaginal 2-D ultrasound scans on the day that the treatment started and then six months later. Measurements of uterine arteries PI, uterine volume and endometrial thickness were performed at both evaluations. The use of LNG-IUDs significantly decreased endometrial thickness (pre = 6.08 +/- 3.00 mm, post = 2.7 +/- 0.98 mm; mean +/- SD), as did the use of GnRHa (pre = 6.96 +/- 3.82 mm, post = 3.23 +/- 2.32 mm). The uterine volume decreased in the GnRHa group (pre = 86.67 +/- 28.38 cm(3), Post = 55.27 +/- 25.52 cm(3)), but not in the LNG-IUD group (pre = 75.77 +/- 20.88 cm(3), post = 75.97 +/- 26.62 cm(3)). Uterine arteries PI increased for both groups; however, the increase was higher in the GnRHa group (0.99 +/- 0.84 vs. 0.38 +/- 0.84, p = 0.007; PI increase in GnRHa and in LNG-IUD groups, respectively). In conclusion, levonorgestrel released directly onto the endometrium by the LNG-IUD induced smaller uterine changes than did the hypoestrogenism induced by GnRHa. Nevertheless, both promoted similar effects on endometrial thickness. (E-mail: wpmartins@gmail.com) (C) 2008 World Federation for Ultrasound in Medicine & Biology.