947 resultados para In vivo methods
Resumo:
OBJECTIVE: The aim of the current study was to monitor the migration of superparamagnetic iron oxide nanoparticle (SPION)-labeled C6 cells, which were used to induce glioblastoma tumor growth in an animal model, over time using magnetic resonance imaging (MRI), with the goal of aiding in tumor prognosis and therapy. METHODS: Two groups of male Wistar rats were used for the tumor induction model. In the first group (n=3), the tumors were induced via the injection of SPION-labeled C6 cells. In the second group (n=3), the tumors were induced via the injection of unlabeled C6 cells. Prussian Blue staining was performed to analyze the SPION distribution within the C6 cells in vitro. Tumor-inducing C6 cells were injected into the right frontal cortex, and subsequent tumor monitoring and SPION detection were performed using T2- and T2*-weighted MRI at a 2T field strength. In addition, cancerous tissue was histologically analyzed after performing the MRI studies. RESULTS: The in vitro qualitative evaluation demonstrated adequate distribution and satisfactory cell labeling of the SPIONs. At 14 or 21 days after C6 injection, a SPION-induced T2- and T2*-weighted MRI signal reduction was observed within the lesion located in the left frontal lobe on parasagittal topography. Moreover, histological staining of the tumor tissue with Prussian Blue revealed a broad distribution of SPIONs within the C6 cells. CONCLUSION: MRI analyses exhibit potential for monitoring the tumor growth of C6 cells efficiently labeled with SPIONs.
Resumo:
Citokines are proteins produced by several cell types and secreted in response to various stimuli. These molecules are able to modify the behaviour of other cells inducing activities like growth, differentiation and apoptosis. In the last years, veterinary scientists have investigated the role played by these factors; in fact, cytokines can act as intercellular communicative signals in immune response, cell damage repair and hematopoiesis. Up to date, various cytokines have been identified and in depth comprehension of their effects in physiology, pathology and therapy is an interesting field of research. This thesis aims to understand the role played by these mediators during natural or experimentally induced pathologies. In particular, it has been evaluated the genic and protein expressions of a large number of cytokines during several diseases and starting from different matrix. Considering the heterogeneity of materials used in experimentations, multiple methods and protocols of nucleic acids and proteins extractions have been standardized. Results on cytokines expression obtained from various in vitro and in vivo experimental studies have shown how important these mediators are in regulation and modulation of the host immune response also in veterinary medicine. In particular, the analysis of inflammatory and septic markers, like cytokines, has allowed a better understanding in the pathogenesis during horse Recurrent Airway Obstruction, foal sepsis, Bovine Viral Diarrhea Virus infection and dog Parvovirus infection and the effects of these agents on the host immune system. As experimentations with mice have shown, some pathologies of the respiratory and nervous system can be reduced or even erased by blocking cytokines inflammatory production. The in vitro cytokines expression evaluation in cells which are in vivo involved in the response to exogenous (like pathogens) or endogenous (as it happens during autoimmune diseases) inflammatory stimuli could represent a model for studying citokines effects during the host immune response. This has been analyzed using lymphocytes cultured with several St. aureus strains isolated from bovine mastitic milk and different colostrum products. In the first experiment different cytokines were expressed depending on enterotoxins produced, justifying a different behaviour of the microrganism in the mammal gland. In the second one, bone marrow cells derived incubated with murine lymphocytes with colostrum products have shown various cluster of differentiation expression , different proliferation and a modified cytokines profile. A better understanding of cytokine expression mechanisms will increase the know-how on immune response activated by several pathogen agents. In particular, blocking the cytokine production, the inhibition or catalyzation of the receptor binding mechanism and the modulation of signal transduction mechanism will represent a novel therapeutic strategy in veterinary medicine.
Resumo:
Die Aufklärung von Biosynthesewegen erfolgt häufig mit Hilfe von Fütterungsexperimenten mit radioaktiven oder stabilen Isotopen markierten Präkusoren oder auf der Basis der Enzymreinigung mit anschließender molekularbiologischer Charakterisierung. Die erstgenannte Methode verlangt die Isolierung der Produkte. Jedoch besteht bei Aufarbeitung und Extraktion immer die Gefahr, daß sich der Metabolit teilweise oder vollständig chemisch verändert. Ein weiterer Nachteil der genannten Methoden ist, daß diese generell mühsam und zeitaufwendig sind. Mit Hilfe der in vivo NMR-Spektroskopie können diese Nachteile umgangen werden. In der vorliegenden Arbeit wurden Biotransformationen und Biosynthesesequenzen des Ajmalin-Biosyntheseweges mit Hilfe der in vivo NMR-Spektroskopie in Pflanzenzellkulturen von Rauvolfia serpentina und Rauvolfia serpentina x Rhazya stricta anhand der natürlichen 13C-Häufigkeit untersucht. Dafür wurden ein 700 MHz, 800 MHz und ein 500 MHz CryoProbe Spektrometer eingesetzt, um die Biotransformationen von Isatin-3-oxim und Isatin sowie die Metabolisierungen der Alkaloide Vellosimin, Vinorin, Vomilenin, Ajmalin, Nß-Methyl-dihydrochano-ajmalin und Perakin mit der 1H-13C invers korrelierten NMR-Spektroskopie zu verfolgen.
Effect of drug physicochemical properties on the release from liposomal systems in vitro and in vivo
Resumo:
Liposomes were discovered about 40 years ago by A. Bangham and since then they became very versatile tools in biology, biochemistry and medicine. Liposomes are the smallest artificial vesicles of spherical shape that can be produced from natural untoxic phospholipids and cholesterol. Liposome vesicles can be used as drug carriers and become loaded with a great variety of molecules, such as small drug molecules, proteins, nucleotides and even plasmids. Due to the variability of liposomal compositions they can be used for a large number of applications. In this thesis the β-adrenoceptor antagonists propranolol, metoprolol, atenolol and pindolol, glucose, 18F-Fluorodeoxyglucose (FDG) and Er-DTPA were used for encapsulation in liposomes, characterization and in vitro release studies. Multilamellar vesicles (MLV), large unilamellar vesicles (LUV) and smaller unilamellar vesicles (SUV) were prepared using one of the following lipids: 1,2-Dimyristoyl-sn-Glycero-3-Phosphocholine (DMPC), 1,2-Distearoyl-sn-Glycero-3-Phosphocholine (DSPC), Phospholipone 90H (Ph90H) or a mixture of DSPC and DMPC (1:1). The freeze thawing method was used for preparation of liposomes because it has three advantages (1) avoiding the use of chloroform, which is used in other methods and causes toxicity (2) it is a simple method and (3) it gives high entrapping efficiency. The percentage of entrapping efficiencies (EE) was different depending on the type and phase transition temperature (Tc) of the lipid used. The average particle size and particle size distribution of the prepared liposomes were determined using both dynamic light scattering (DLS) and laser diffraction analyzer (LDA). The average particle size of the prepared liposomes differs according to both liposomal type and lipid type. Dispersion and dialysis techniques were used for the study of the in vitro release of β-adrenoceptor antagonists. The in vitro release rate of β-adrenoceptor antagonists was increased from MLV to LUV to SUV. Regarding the lipid type, β-adrenoceptor antagonists exhibited different in vitro release pattern from one lipid to another. Two different concentrations (50 and 100mg/ml) of Ph90H were used for studying the effect of lipid concentration on the in vitro release of β-adrenoceptor antagonists. It was found that liposomes made from 50 mg/ml Ph90H exhibited higher release rates than liposomes made at 100 mg/ml Ph90H. Also glucose was encapsulated in MLV, LUV and SUV using 1,2-Dimyristoyl-sn-Glycero-3-Phosphocholine (DMPC), 1,2-Distearoyl-sn-Glycero-3-Phosphocholine (DSPC), Phospholipone 90H (Ph90H), soybean lipid (Syb) or a mixture of DSPC and DMPC (1:1). The average particle size and size distribution were determined using laser diffraction analysis. It was found that both EE and average particle size differ depending on both lipid and liposomal types. The in vitro release of glucose from different types of liposomes was performed using a dispersion method. It was found that the in vitro release of glucose from different liposomes is dependent on the lipid type. 18F-FDG was encapsulated in MLV 1,2-Dimyristoyl-sn-Glycero-3-Phosphocholine (DMPC), 1,2-Distearoyl-sn-Glycero-3-Phosphocholine (DSPC), Phospholipone 90H (Ph90H), soybean lipid (Syb) or a mixture of DSPC and DMPC (1:1). FDG-containing LUV and SUV were prepared using Ph90H lipid. The in vitro release of FDG from the different types of lipids was accomplished using a dispersion method. Results similar to that of glucose release were obtained. In vivo imaging of FDG in both uncapsulated FDG and FDG-containing MLV was performed in the brain and the whole body of rats using PET scanner. It was found that the release of FDG from FDG-containing MLV was sustained. In vitro-In vivo correlation was studied using the in vitro release data of FDG from liposomes and in vivo absorption data of FDG from injected liposomes using microPET. Erbium, which is a lanthanide metal, was used as a chelate with DTPA for encapsulation in SUV liposomes for the indirect radiation therapy of cancer. The liposomes were prepared using three different concentrations of soybean lipid (30, 50 and 70 mg/ml). The stability of Er-DTPA SUV liposomes was carried out by storage of the prepared liposomes at three different temperatures (4, 25 and 37 °C). It was found that the release of Er-DTPA complex is temperature dependent, the higher the temperature, the higher the release. There was an inverse relationship between the release of the Er-DTPA complex and the concentration of lipid.
Resumo:
This current work focused on the simulation of in vivo dissolution and permeation in order to be able to predict the in vivo performance of orally administered fenofibrate immediate release formulations. Therefore, the effects of the formulation surfactants on in vivo solubility and permeation of fenofibrate under physiologically relevant excipient concentrations were emphasized.rnIt was shown that the surfactant sodium dodecyl sulfate (SDS) may decrease rather than increase the solubility of fenofibrate in vivo. This was related to the interference of SDS with the vesicular system of the biorelevant medium, FaSSIFmod, and therefore its solubilization capacity. rnMoreover, in vitro permeation studies revealed that SDS concentrations inversely correlated with fenofibrate permeability. Through combination of the observed permeation and solubility data a good in vitro/in vivo correlation regarding Cmax values in humans could be established for five fenofibrate formulations which were based on the same manufacturing technique.rnBesides the experimental part, the major characteristics and their potential implementation in a dissolution/permeation device were discussed based on the promising realization of the in vitro solubility and permeation methods. rn
Resumo:
Dendritische Zellen der Haut, wie z.B. die Langerhanszellen (LC) der Epidermis, sind potente antigenpräsentierende Zellen (APC). Nach allogener Blutstammzelltransplantation (engl.: hematopoietic stemm cell transplantation, HSCT) persistieren Empfänger-APC und können Spender-T-Zellen aktivieren. Somit spielen dendritische Zellen eine kritische Rolle bei der Initiierung von akuter Transplantat-Gegen-Wirt-Reaktion (engl.: graft-versus-host-disease, GvHD).rnIn der vorliegenden Arbeit wurde ein Modellsystem entwickelt, welches humane Haut in einem Xenotransplantationsmodell nutzt, um die Wechselwirkung dieser gewebsständigen APC mit alloreaktiven T-Zellen zu untersuchen. Dafür wurden humane Resthautpräparate von subkutanem Gewebe befreit und intraskaptulär auf immunsupprimierte NOD/LtSz-scid IL2R#-null Mäuse (NSG) transplantiert. Diesen Tieren fehlen funktionale T-, B- und NK-Zellen, und sie tolerieren somit ein xenogenes Transplantat. Im Vergleich zu anderen immundefizienten Stämmen, haben sie eine erhöhte Lebenserwartung und es ist zudem möglich humane Hämatopoese durch Stammzellgabe zu etablieren.rnPublizierte Methoden der Hauttransplantation wurden für diese Arbeit optimiert und weiterentwickelt. So konnte die Erfolgsrate von 44% auf bis zu 95% gesteigert werden. Erste Untersuchungen fokussierten den Einfluss der Wundheilung auf die Verteilung dermaler Zellpopulationen, wie z.B. CD11c positive APC, und die Population der LC in der Epidermis. Während der ersten Wochen der Wundheilung war ein vorübergehendes Verschwinden der LC aus der Epidermis zu beobachten. Im Gegensatz dazu waren CD11c positive dermale Zellen permanent detektierbar. Die zu späteren Zeitpunkten festgestellte Repopulation der Epidermis mit LC unterstützt die Hypothese einer lokalen Vorläuferzelle. Die vorgelegten Daten und die lokale proliferative Aktivität dieser Zellen unterstreichen ihre Unabhängigkeit vom peripheren Blut. Versuche, eine Depletion der LC mittels UVC-Bestrahlung zu erreichen, gelangen nicht. Auch dies spricht für das Vorhandensein eines lokalen Vorläufers.rnZur Induktion von GvHD in der transplantierten Haut wurden in vitro DC des Hautspenders generiert und damit HLA-disparate T-Zellen stimuliert. Auf diese Weise sollte eine maximale Alloreaktivität gegen das Hauttransplantat generiert werden. In allen vorgestellten Systemen ließ sich nach Infusion der T-Lymphozyten in transplantierte Tiere, eine T-Zellinduzierte inflammatorische Reaktion auslösen. Optisch war eine deutliche Rötung des Transplantats feststellbar. Diese war jedoch nur in den Proben besonders deutlich, welche T-Zellen mit vorheriger in vitro Stimulation durch DC des Hautspenders erhalten hatten. Histologisch konnten Anzeichen einer Entzündung nachgewiesen werden. Neben Akanthose und Hyperparakeratose, waren deutliche T-Zellinfiltrate detektierbar. Auch Spaltbildung und Ablösung der Epidermis, sowie vereinzelte Apoptosen der epidermalen Zellen wiesen auf eine GvHD artige Entzündung hin.rnEine weitere Beobachtung nach T-Zellgabe, war die Depletion der LC aus der Epidermis. Auch konnte durch spätere T-Zellgaben keine weitere Hautrötung ausgelöst werden. Dies belegt die Funktion der LC als primäre Zielzelle der alloreaktiven T-Zellen. Unterstrichen wird dies durch Verwendung einer LC defizienten Haut, welche keine Hautrötung oder Anzeichen einer Entzündung entwickelte.rnZusammenfassend wurde für diese Arbeit ein Modellsystem entwickelt, welches es erlaubt Untersuchungen entzündlicher Hautkrankheiten unter Berücksichtigung hautständiger APC durchzuführen. Dabei kann dieses Modell in Zukunft für die Untersuchung von APC modulierenden Agenzien genutzt werden, da präklinische Modelle für spezies-spezifische Therapien bislang fehlten. Das Entstehen einer Entzündung könnte so verhindert oder eine Behandlung ermöglicht werden.
Resumo:
We investigated whether human articular chondrocytes can be labeled efficiently and for long-term with a green fluorescent protein (GFP) lentivirus and whether the viral transduction would influence cell proliferation and tissue-forming capacity. The method was then applied to track goat articular chondrocytes after autologous implantation in cartilage defects. Expression of GFP in transduced chondrocytes was detected cytofluorimetrically and immunohistochemically. Chondrogenic capacity of chondrocytes was assessed by Safranin-O staining, immunostaining for type II collagen, and glycosaminoglycan content. Human articular chondrocytes were efficiently transduced with GFP lentivirus (73.4 +/- 0.5% at passage 1) and maintained the expression of GFP up to 22 weeks of in vitro culture after transduction. Upon implantation in nude mice, 12 weeks after transduction, the percentage of labeled cells (73.6 +/- 3.3%) was similar to the initial one. Importantly, viral transduction of chondrocytes did not affect the cell proliferation rate, chondrogenic differentiation, or tissue-forming capacity, either in vitro or in vivo. Goat articular chondrocytes were also efficiently transduced with GFP lentivirus (78.3 +/- 3.2%) and maintained the expression of GFP in the reparative tissue after orthotopic implantation. This study demonstrates the feasibility of efficient and relatively long-term labeling of human chondrocytes for co-culture on integration studies, and indicates the potential of this stable labeling technique for tracking animal chondrocytes for in cartilage repair studies.
Resumo:
OBJECTIVES: The aim of this randomised clinical trial was to investigate if a laser fluorescence device is able to discriminate between sound and carious approximal sites and between enamel and dentinal lesions, as well as to find appropriate cut-off values. METHODS: One hundred and seventeen sound or uncavitated carious sites in permanent molars were visually and radiographically examined, then either opened or not, after which their laser fluorescence was measured. Forty-three lesions were opened, the caries removed and the clinically identified caries depths were registered in addition to the radiographical scoring. Seventy-four sites were radiographically deemed sound or had enamel caries and were not opened. Here, the radiographical scorings were registered. RESULTS: Taking the radiographic scoring as gold standard for all investigated approximal sites, sound sites (D(0), n=40) showed significantly lower laser fluorescence measurements than carious sites (D(1-4), n=77) (Mann-Whitney test, P<0.025) suggesting a cut-off at 7 (sensitivity=0.68, specificity=0.7). Comparing measurements of D(0-2) (n=74) and D(3,4) (n=43), the results were also different by a statistically significant amount (P<0.025) and the cut-off calculated to be 16 (sensitivity=0.6, specificity=0.84). A fair positive correlation between laser fluorescence values and radiographical scoring was found (rho=+0.47, P<0.01). Analysing the 43 opened lesions with their clinically found lesion depths as gold standard, there was a fair positive correlation to the laser fluorescence values (rho=+0.34, P=0.03) and a moderately strong correlation to the radiographic scoring (rho=+0.67, P<0.01). CONCLUSION: The device may be an adjunct tool in the approximal detection of caries along with established procedures.
Resumo:
Microneurography is a method suitable for recording intraneural single or multiunit action potentials in conscious subjects. Microneurography has rarely been applied to animal experiments, where more invasive methods, like the teased fiber recording technique, are widely used. We have tested the feasibility of microneurographic recordings from the peripheral nerves of rats. Tungsten microelectrodes were inserted into the sciatic nerve at mid-thigh level. Single or multiunit action potentials evoked by regular electrical stimulation were recorded, digitized and displayed as a raster plot of latencies. The method allows unambiguous recording and recognition of single C-fiber action potentials from an in vivo preparation, with minimal disruption of the nerve being recorded. Multiple C-fibers can be recorded simultaneously for several hours, and if the animal is allowed to recover, repeated recording sessions can be obtained from the same nerve at the same level over a period of weeks or months. Also, single C units can be functionally identified by their changes in latency to natural stimuli, and insensitive units can be recognized as 'silent' nociceptors or sympathetic efferents by their distinctive profiles of activity-dependent slowing during repetitive electrical stimulation, or by the effect on spontaneous efferent activity of a proximal anesthetic block. Moreover, information about the biophysical properties of C axons can be obtained from their latency recovery cycles. Finally, we show that this preparation is potentially suitable for the study of C-fiber behavior in models of neuropathies and nerve lesions, both under resting conditions and in response to drug administration.
Resumo:
Background—Pathology studies on fatal cases of very late stent thrombosis have described incomplete neointimal coverage as common substrate, in some cases appearing at side-branch struts. Intravascular ultrasound studies have described the association between incomplete stent apposition (ISA) and stent thrombosis, but the mechanism explaining this association remains unclear. Whether the neointimal coverage of nonapposed side-branch and ISA struts is delayed with respect to well-apposed struts is unknown. Methods and Results—Optical coherence tomography studies from 178 stents implanted in 99 patients from 2 randomized trials were analyzed at 9 to 13 months of follow-up. The sample included 38 sirolimus-eluting, 33 biolimus-eluting, 57 everolimus-eluting, and 50 zotarolimus-eluting stents. Optical coherence tomography coverage of nonapposed side-branch and ISA struts was compared with well-apposed struts of the same stent by statistical pooled analysis with a random-effects model. A total of 34 120 struts were analyzed. The risk ratio of delayed coverage was 9.00 (95% confidence interval, 6.58 to 12.32) for nonapposed side-branch versus well-apposed struts, 9.10 (95% confidence interval, 7.34 to 11.28) for ISA versus well-apposed struts, and 1.73 (95% confidence interval, 1.34 to 2.23) for ISA versus nonapposed side-branch struts. Heterogeneity of the effect was observed in the comparison of ISA versus well-apposed struts (H=1.27; I2=38.40) but not in the other comparisons. Conclusions—Coverage of ISA and nonapposed side-branch struts is delayed with respect to well-apposed struts in drug-eluting stents, as assessed by optical coherence tomography.
Resumo:
BACKGROUND AND PURPOSE: Currently, several new stent retriever devices for acute stroke treatment are under development and early clinical evaluation. Preclinical testing under standardized conditions is an important first step to evaluate the technical performance and potential of these devices. The aim of this study was to evaluate the immediate recanalization effect, recanalization efficacy, thrombus-device interaction, and safety of a new stent retriever intended for thrombectomy in patients with acute stroke. MATERIAL AND METHODS: The pREset thrombectomy device (4 × 20 mm) was evaluated in 16 vessel occlusions in an established swine model. Radiopaque thrombi (10-mm length) were used for visualization of thrombus-device interaction during application and retrieval. Flow-restoration effect immediately after deployment and after 5-minute embedding time before retrieval, recanalization rate after retrieval, thromboembolic events, and complications were assessed. High-resolution FPCT was performed to illustrate thrombus-device interaction during the embedding time. RESULTS: Immediate flow restoration was achieved in 75% of occlusions. An increase or stable percentage of recanalizations during embedding time before retrieval was seen in 56.3%; a decrease, in 12.5%; reocclusion of a previously recanalized vessel, in 18.8%; and no recanalization effect at all, in 12.5%. Complete recanalization (TICI 3) after retrieval was achieved in 93.8%; partial recanalization (TICI 2b), in 6.2%. No distal thromboembolic events were observed. High-resolution FPCT illustrated entrapment of the thrombus between the stent struts and compression against the contralateral vessel wall, leading to partial flow restoration. During retrieval, the thrombus was retained in a straight position within the stent struts. CONCLUSIONS: In this experimental study, the pREset thrombus retriever showed a high recanalization rate in vivo. High-resolution FPCT allows detailed illustration of the thrombus-device interaction during embedding time and is advocated as an add-on tool to the animal model used in this study.
Resumo:
Binding of hydrophobic chemicals to colloids such as proteins or lipids is difficult to measure using classical microdialysis methods due to low aqueous concentrations, adsorption to dialysis membranes and test vessels, and slow kinetics of equilibration. Here, we employed a three-phase partitioning system where silicone (polydimethylsiloxane, PDMS) serves as a third phase to determine partitioning between water and colloids and acts at the same time as a dosing device for hydrophobic chemicals. The applicability of this method was demonstrated with bovine serum albumin (BSA). Measured binding constants (K(BSAw)) for chlorpyrifos, methoxychlor, nonylphenol, and pyrene were in good agreement with an established quantitative structure-activity relationship (QSAR). A fifth compound, fluoxypyr-methyl-heptyl ester, was excluded from the analysis because of apparent abiotic degradation. The PDMS depletion method was then used to determine partition coefficients for test chemicals in rainbow trout (Oncorhynchus mykiss) liver S9 fractions (K(S9w)) and blood plasma (K(bloodw)). Measured K(S9w) and K(bloodw) values were consistent with predictions obtained using a mass-balance model that employs the octanol-water partition coefficient (K(ow)) as a surrogate for lipid partitioning and K(BSAw) to represent protein binding. For each compound, K(bloodw) was substantially greater than K(S9w), primarily because blood contains more lipid than liver S9 fractions (1.84% of wet weight vs 0.051%). Measured liver S9 and blood plasma binding parameters were subsequently implemented in an in vitro to in vivo extrapolation model to link the in vitro liver S9 metabolic degradation assay to in vivo metabolism in fish. Apparent volumes of distribution (V(d)) calculated from the experimental data were similar to literature estimates. However, the calculated binding ratios (f(u)) used to relate in vitro metabolic clearance to clearance by the intact liver were 10 to 100 times lower than values used in previous modeling efforts. Bioconcentration factors (BCF) predicted using the experimental binding data were substantially higher than the predicted values obtained in earlier studies and correlated poorly with measured BCF values in fish. One possible explanation for this finding is that chemicals bound to proteins can desorb rapidly and thus contribute to metabolic turnover of the chemicals. This hypothesis remains to be investigated in future studies, ideally with chemicals of higher hydrophobicity.
Resumo:
REASONS FOR PERFORMING STUDY: Evidence-based information is limited on distribution of local anaesthetic solution following perineural analgesia of the palmar (Pa) and palmar metacarpal (PaM) nerves in the distal aspect of the metacarpal (Mc) region ('low 4-point nerve block'). OBJECTIVES: To demonstrate the potential distribution of local anaesthetic solution after a low 4-point nerve block using a radiographic contrast model. METHODS: A radiodense contrast medium was injected subcutaneously over the medial or the lateral Pa nerve at the junction of the proximal three-quarters and distal quarter of the Mc region (Pa injection) and over the ipsilateral PaM nerve immediately distal to the distal aspect of the second or fourth Mc bones (PaM injection) in both forelimbs of 10 mature horses free from lameness. Radiographs were obtained 0, 10 and 20 min after injection and analysed subjectively and objectively. Methylene blue and a radiodense contrast medium were injected in 20 cadaver limbs using the same techniques. Radiographs were obtained and the limbs dissected. RESULTS: After 31/40 (77.5%) Pa injections, the pattern of the contrast medium suggested distribution in the neurovascular bundle. There was significant proximal diffusion with time, but the main contrast medium patch never progressed proximal to the mid-Mc region. The radiological appearance of 2 limbs suggested that contrast medium was present in the digital flexor tendon sheath (DFTS). After PaM injections, the contrast medium was distributed diffusely around the injection site in the majority of the limbs. In cadaver limbs, after Pa injections, the contrast medium and the dye were distributed in the neurovascular bundle in 8/20 (40%) limbs and in the DFTS in 6/20 (30%) of limbs. After PaM injections, the contrast and dye were distributed diffusely around the injection site in 9/20 (45%) limbs and showed diffuse and tubular distribution in 11/20 (55%) limbs. CONCLUSIONS AND POTENTIAL RELEVANCE: Proximal diffusion of local anaesthetic solution after a low 4-point nerve block is unlikely to be responsible for decreasing lameness caused by pain in the proximal Mc region. The DFTS may be penetrated inadvertently when performing a low 4-point nerve block.
Resumo:
BACKGROUND AND PURPOSE:Conventional platinum coils cause imaging artifacts that reduce imaging quality and therefore impair imaging interpretation on intraprocedural or noninvasive follow-up imaging. The purpose of this study was to evaluate imaging characteristics and artifact production of polymeric coils compared with standard platinum coils in vitro and in vivo.MATERIALS AND METHODS:Polymeric coils and standard platinum coils were evaluated in vitro with the use of 2 identical silicon aneurysm models coiled with a packing attenuation of 20% each. DSA, flat panel CT, CT, and MR imaging were performed. In vivo evaluation of imaging characteristics of polymeric coils was performed in experimentally created rabbit carotid bifurcation aneurysms. DSA, CT/CTA, and MR imaging were performed after endovascular treatment of the aneurysms. Images were evaluated regarding visibility of individual coils, coil mass, artifact production, and visibility of residual flow within the aneurysm.RESULTS:Overall, in vitro and in vivo imaging showed relevantly reduced artifact production of polymeric coils in all imaging modalities compared with standard platinum coils. Image quality of CT and MR imaging was improved with the use of polymeric coils, which permitted enhanced depiction of individual coil loops and residual aneurysm lumen as well as the peri-aneurysmal area. Remarkably, CT images demonstrated considerably improved image quality with only minor artifacts compared with standard coils. On DSA, polymeric coils showed transparency and allowed visualization of superimposed vessel structures.CONCLUSIONS:This initial experimental study showed improved imaging quality with the use of polymeric coils compared with standard platinum coils in all imaging modalities. This might be advantageous for improved intraprocedural imaging for the detection of complications and posttreatment noninvasive follow-up imaging.
Resumo:
BACKGROUND AND PURPOSE: Mechanical thrombectomy is a promising new modality of interventional stroke treatment. The various devices differ with regard to where they apply force on the thrombus, taking a proximal approach such as aspiration devices or a distal approach such as basket-like devices. The study compares the in vivo effectiveness and thrombus-device interaction of these 2 approaches. METHODS: Angiography and embolization with a radioopaque whole blood thrombus was performed in 10 swine. Mechanical thrombectomy was performed in 20 cranial vessels using a proximal aspiration device (Vasco35) and a distal basket-like device (Catch) with and without proximal balloon occlusion. Fifty-six retrieval attempts were made. RESULTS: The proximal device allowed fast repeated application with a low risk of thromboembolic events (3%) and vasospasm, but it had a significantly lower success rate (39.4%) in retrieving thrombotic material than the distal device (DD) (82.6%; odds ratio, 7.3; 95% CI, 2.0 to 26.4). The compaction of the thrombus during retrieval with DD increased the risk of vessel wall irritation significantly (P<0.01) and complicated retrieval into the guiding catheter. The number of embolic events was significantly higher with DD (26%; odds ratio, 11.3; 95% CI, 1.35 to 101.6) unless proximal balloon occlusion was used. CONCLUSIONS: The proximal and the distal approaches to mechanical thrombectomy proved to be effective at achieving recanalization of cranial vessels. The proximal device is faster in application and allowed repeated attempts with a low complication rate. The DD is more successful at removing thrombotic material, but its method of application and attendant thrombus compaction increase the risk of thromboembolic events and vasospasms.