993 resultados para Fibrin Fibrinogen Degradation Products


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Biomaterials have been used for more than a century in the human body to improve body functions and replace damaged tissues. Currently approved and commonly used metallic biomaterials such as, stainless steel, titanium, cobalt chromium and other alloys have been found to have adverse effects leading in some cases, to mechanical failure and rejection of the implant. The physical or chemical nature of the degradation products of some implants initiates an adverse foreign body reaction in the tissue. Some metallic implants remain as permanent fixtures, whereas others such as plates, screws and pins used to secure serious fractures are removed by a second surgical procedure after the tissue has healed sufficiently. However, repeat surgical procedures increase the cost of health care and the possibility of patient morbidity. This study focuses on the development of magnesium based biodegradable alloys/metal matrix composites (MMCs) for orthopedic and cardiovascular applications. The Mg alloys/MMCs possessed good mechanical properties and biocompatible properties. Nine different compositions of Mg alloys/MMCs were manufactured and surface treated. Their degradation behavior, ion leaching, wettability, morphology, cytotoxicity and mechanical properties were determined. Alloying with Zn, Ca, HA and Gd and surface treatment resulted in improved mechanical properties, corrosion resistance, reduced cytotoxicity, lower pH and hydrogen evolution. Anodization resulted in the formation of a distinct oxide layer (thickness 5-10 μm) as compared with that produced on mechanically polished samples (~20-50 nm) under ambient conditions. It is envisaged that the findings of this research will introduce a new class of Mg based biodegradable alloys/MMCs and the emergence of innovative cardiovascular and orthopedic implant devices.^

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Existing instrumental techniques must be adaptable to the analysis of novel explosives if science is to keep up with the practices of terrorists and criminals. The focus of this work has been the development of analytical techniques for the analysis of two types of novel explosives: ascorbic acid-based propellants, and improvised mixtures of concentrated hydrogen peroxide/fuel. In recent years, the use of these explosives in improvised explosive devices (IEDs) has increased. It is therefore important to develop methods which permit the identification of the nature of the original explosive from post-blast residues. Ascorbic acid-based propellants are low explosives which employ an ascorbic acid fuel source with a nitrate/perchlorate oxidizer. A method which utilized ion chromatography with indirect photometric detection was optimized for the analysis of intact propellants. Post-burn and post-blast residues if these propellants were analyzed. It was determined that the ascorbic acid fuel and nitrate oxidizer could be detected in intact propellants, as well as in the post-burn and post-blast residues. Degradation products of the nitrate and perchlorate oxidizers were also detected. With a quadrupole time-of-flight mass spectrometer (QToFMS), exact mass measurements are possible. When an HPLC instrument is coupled to a QToFMS, the combination of retention time with accurate mass measurements, mass spectral fragmentation information, and isotopic abundance patterns allows for the unequivocal identification of a target analyte. An optimized HPLC-ESI-QToFMS method was applied to the analysis of ascorbic acid-based propellants. Exact mass measurements were collected for the fuel and oxidizer anions, and their degradation products. Ascorbic acid was detected in the intact samples and half of the propellants subjected to open burning; the intact fuel molecule was not detected in any of the post-blast residue. Two methods were optimized for the analysis of trace levels of hydrogen peroxide: HPLC with fluorescence detection (HPLC-FD), and HPLC with electrochemical detection (HPLC-ED). Both techniques were extremely selective for hydrogen peroxide. Both methods were applied to the analysis of post-blast debris from improvised mixtures of concentrated hydrogen peroxide/fuel; hydrogen peroxide was detected on variety of substrates. Hydrogen peroxide was detected in the post-blast residues of the improvised explosives TATP and HMTD.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In order to provide a better understanding of the fate of sedimentary chlorophyll and chlorophyll degradation products in all kinds of environments, we have recently expanded our studies to include examination of sediments returned from Legs which are not rich in organic matter, nor are even primarily biogenic. Eight core samples from the Mariana Basin and Trench, obtained from DSDP Leg 60, were analyzed for products of chlorophyll diagenesis. To date, the sediment samples from the South Philippine Sea have been the most organically barren examined. Through elimination of the bias of examining only sediments rich in organic matter, we hope that the fate of chlorophyllous material on a more global scale will eventually be elucidated.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Chloropigments and their derivative pheopigments preserved in sediments can directly be linked to photosynthesis. Their carbon and nitrogen stable isotopic compositions have been shown to be a good recorder of recent and past surface ocean environmental conditions tracing the carbon and nitrogen sources and dominant assimilation processes of the phytoplanktonic community. In this study we report results from combined compound-specific radiocarbon and stable carbon and nitrogen isotope analysis to examine the time-scales of synthesis and fate of chlorophyll-a and its degradation products pheophytin-a, pyropheophytin-a, and 132,173-cyclopheophorbide-a-enol until burial in Black Sea core-top sediments. The pigments are mainly of marine phytoplanktonic origin as implied by their stable isotopic compositions. Pigment ?15N values indicate nitrate as the major uptake substrate but 15N-depletion towards the open marine setting indicates either contribution from N2-fixation or direct uptake of ammonium from deeper waters. Radiocarbon concentrations translate into minimum and maximum pigment ages of approximately 40 to 1200 years. This implies that protective mechanisms against decomposition such as association with minerals, storage in deltaic anoxic environments, or eutrophication-induced hypoxia and light limitation are much more efficient than previously thought. Moreover, seasonal variations of nutrient source, growth period, and habitat and their associated isotopic variability are likely at least as strong as long-term trends. Combined triple isotope analysis of sedimentary chlorophyll and its primary derivatives is a powerful tool to delineate biogeochemical and diagenetic processes in the surface water and sediments, and to assess their precise time-scales.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Nitrogen isotopes of chlorins, degradation products of chlorophyll, reflect the isotopic composition of nutrient N utilized by marine phytoplankton communities. Here we show that in sediments of the eastern Mediterranean Pleistocene and Holocene, values of d15N for chlorins and total nitrogen vary in concert, with a consistent offset of ~5 per mil reflecting the fractionation imparted during chlorophyll biosynthesis. Samples from the Integrated Ocean Drilling Program Sites 964 and 969 were analyzed at a sampling resolution of ~4-10 cm, clustered around sapropel events 2, 3, 4 and 5 (~100-170 ka). In low organic content sediments, chlorin values of ~0 per mil coincident with total nitrogen values of ~+ 5 per mil indicate that the latter reflects the original biomass and is not a consequence of diagenetic isotope enrichment. In sapropel horizons, the chlorin and total nitrogen values are 5 per mil more negative (~-5 per mil and ~ 0 per mil, respectively), resembling previously-reported, modern-day water-column particulates (~0 per mil). We suggest that nutrient conditions in the Eastern Mediterranean correspond to three scenarios and that the similarity between sapropel and modern-day bulk d15N is coincidental. Organic-poor marl sediments formed under oligotrophic conditions where surface productivity resulted from upwelling of Atlantic-sourced nitrate. Sapropels were characterized by enhanced diazotrophy that was likely fueled by increased riverine P fluxes to surface waters. Present-day conditions are dominated by anthropogenic N sources. These scenarios agree with a model of sapropel formation in which stratification caused by increased fresh-water inputs led to N fixation due to P:N nutrient imbalance. Enhanced production combined with stratification promoted and maintained anoxic deep waters, consequently increasing organic matter preservation. Such a model may be relevant to interpreting other episodes of intense organic matter deposition in past oceans.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

La spectrométrie de masse mesure la masse des ions selon leur rapport masse sur charge. Cette technique est employée dans plusieurs domaines et peut analyser des mélanges complexes. L’imagerie par spectrométrie de masse (Imaging Mass Spectrometry en anglais, IMS), une branche de la spectrométrie de masse, permet l’analyse des ions sur une surface, tout en conservant l’organisation spatiale des ions détectés. Jusqu’à présent, les échantillons les plus étudiés en IMS sont des sections tissulaires végétales ou animales. Parmi les molécules couramment analysées par l’IMS, les lipides ont suscité beaucoup d'intérêt. Les lipides sont impliqués dans les maladies et le fonctionnement normal des cellules; ils forment la membrane cellulaire et ont plusieurs rôles, comme celui de réguler des événements cellulaires. Considérant l’implication des lipides dans la biologie et la capacité du MALDI IMS à les analyser, nous avons développé des stratégies analytiques pour la manipulation des échantillons et l’analyse de larges ensembles de données lipidiques. La dégradation des lipides est très importante dans l’industrie alimentaire. De la même façon, les lipides des sections tissulaires risquent de se dégrader. Leurs produits de dégradation peuvent donc introduire des artefacts dans l’analyse IMS ainsi que la perte d’espèces lipidiques pouvant nuire à la précision des mesures d’abondance. Puisque les lipides oxydés sont aussi des médiateurs importants dans le développement de plusieurs maladies, leur réelle préservation devient donc critique. Dans les études multi-institutionnelles où les échantillons sont souvent transportés d’un emplacement à l’autre, des protocoles adaptés et validés, et des mesures de dégradation sont nécessaires. Nos principaux résultats sont les suivants : un accroissement en fonction du temps des phospholipides oxydés et des lysophospholipides dans des conditions ambiantes, une diminution de la présence des lipides ayant des acides gras insaturés et un effet inhibitoire sur ses phénomènes de la conservation des sections au froid sous N2. A température et atmosphère ambiantes, les phospholipides sont oxydés sur une échelle de temps typique d’une préparation IMS normale (~30 minutes). Les phospholipides sont aussi décomposés en lysophospholipides sur une échelle de temps de plusieurs jours. La validation d’une méthode de manipulation d’échantillon est d’autant plus importante lorsqu’il s’agit d’analyser un plus grand nombre d’échantillons. L’athérosclérose est une maladie cardiovasculaire induite par l’accumulation de matériel cellulaire sur la paroi artérielle. Puisque l’athérosclérose est un phénomène en trois dimension (3D), l'IMS 3D en série devient donc utile, d'une part, car elle a la capacité à localiser les molécules sur la longueur totale d’une plaque athéromateuse et, d'autre part, car elle peut identifier des mécanismes moléculaires du développement ou de la rupture des plaques. l'IMS 3D en série fait face à certains défis spécifiques, dont beaucoup se rapportent simplement à la reconstruction en 3D et à l’interprétation de la reconstruction moléculaire en temps réel. En tenant compte de ces objectifs et en utilisant l’IMS des lipides pour l’étude des plaques d’athérosclérose d’une carotide humaine et d’un modèle murin d’athérosclérose, nous avons élaboré des méthodes «open-source» pour la reconstruction des données de l’IMS en 3D. Notre méthodologie fournit un moyen d’obtenir des visualisations de haute qualité et démontre une stratégie pour l’interprétation rapide des données de l’IMS 3D par la segmentation multivariée. L’analyse d’aortes d’un modèle murin a été le point de départ pour le développement des méthodes car ce sont des échantillons mieux contrôlés. En corrélant les données acquises en mode d’ionisation positive et négative, l’IMS en 3D a permis de démontrer une accumulation des phospholipides dans les sinus aortiques. De plus, l’IMS par AgLDI a mis en évidence une localisation différentielle des acides gras libres, du cholestérol, des esters du cholestérol et des triglycérides. La segmentation multivariée des signaux lipidiques suite à l’analyse par IMS d’une carotide humaine démontre une histologie moléculaire corrélée avec le degré de sténose de l’artère. Ces recherches aident à mieux comprendre la complexité biologique de l’athérosclérose et peuvent possiblement prédire le développement de certains cas cliniques. La métastase au foie du cancer colorectal (Colorectal cancer liver metastasis en anglais, CRCLM) est la maladie métastatique du cancer colorectal primaire, un des cancers le plus fréquent au monde. L’évaluation et le pronostic des tumeurs CRCLM sont effectués avec l’histopathologie avec une marge d’erreur. Nous avons utilisé l’IMS des lipides pour identifier les compartiments histologiques du CRCLM et extraire leurs signatures lipidiques. En exploitant ces signatures moléculaires, nous avons pu déterminer un score histopathologique quantitatif et objectif et qui corrèle avec le pronostic. De plus, par la dissection des signatures lipidiques, nous avons identifié des espèces lipidiques individuelles qui sont discriminants des différentes histologies du CRCLM et qui peuvent potentiellement être utilisées comme des biomarqueurs pour la détermination de la réponse à la thérapie. Plus spécifiquement, nous avons trouvé une série de plasmalogènes et sphingolipides qui permettent de distinguer deux différents types de nécrose (infarct-like necrosis et usual necrosis en anglais, ILN et UN, respectivement). L’ILN est associé avec la réponse aux traitements chimiothérapiques, alors que l’UN est associé au fonctionnement normal de la tumeur.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose To compare and examine the storage stability of compounded bevacizumab in polycarbonate (PC) and polypropylene (PP) syringes over a 6-month period. PC syringes have been used in a recent clinical study and bevacizumab stability has not been reported for this type of syringe. Methods Repackaged bevacizumab was obtained from Moorfields Pharmaceuticals in polycarbonate (PC) and polypropylene (PP) syringes. Bevacizumab from the stored syringes was analysed at monthly time points for a 6-month period and compared with bevacizumab from a freshly opened vial at each time point. SDS-PAGE electrophoresis and size-exclusion chromatography (SEC) was used to observe aggregation and degradation. Dynamic light scattering (DLS) provided information about the hydrodynamic size and particle size distribution of bevacizumab in solution. VEGF binding and the active concentration of bevacizumab was determined by surface plasmon resonance (SPR) using Biacore. Results SDS-PAGE and SEC analysis did not show any changes in the presence of higher molecular species (HMWS) or degradation products in PC and PP syringes from T0 to T6 compared to bevacizumab sampled from a freshly opened vial. The hydrodynamic diameter of bevacizumab in the PC syringe after six months of storage was not significantly different to bevacizumab taken from a freshly opened vial. Using SPR, the VEGF binding activity of bevacizumab in the PC syringe was comparable with bevacizumab taken from a freshly opened vial. Conclusion No significant difference over a 6-month period was observed in the quality of bevacizumab repackaged into prefilled PC polycarbonate and PP polypropylene syringes when compared to bevacizumab that is supplied from the vial.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Lignocellulosicwaste from the pineapple production is a raw material useful for the xylose production by hydrolysis and it can be converted to xylitol. The objective of this work was to study the hydrolysis of pineapple peel with sulfuric acid at variable concentration (2-6%), reaction time (0-350 min) and temperature at 98 ˚C. The concentration of xylose, glucose and degradation products as acetic acid and furfural was determined. Optimal conditions found for hydrolysis were 6% H2SO4 at 98 ˚C for 83 min which yield was 26,9 g xylose/L, 2,61 g glucose/L, 7,71 g acetic acid/L and 0,29 g furfural/L.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A micro gas sensor has been developed by our group for the detection of organo-phosphate vapors using an aqueous oxime solution. The analyte diffuses from the high flow rate gas stream through a porous membrane to the low flow rate aqueous phase. It reacts with the oxime PBO (1-Phenyl-1,2,3,-butanetrione 2-oxime) to produce cyanide ions, which are then detected electrochemically from the change in solution potential. Previous work on this oxime based electrochemistry indicated that the optimal buffer pH for the aqueous solution was approximately 10. A basic environment is needed for the oxime anion to form and the detection reaction to take place. At this specific pH, the potential response of the sensor to an analyte (such as acetic anhydride) is maximized. However, sensor response slowly decreases as the aqueous oxime solution ages, by as much as 80% in first 24 hours. The decrease in sensor response is due to cyanide which is produced during the oxime degradation process, as evidenced by the cyanide selective electrode. Solid phase micro-extraction carried out on the oxime solution found several other possible degradation products, including acetic acid, N-hydroxy benzamide, benzoic acid, benzoyl cyanide, 1-Phenyl 1,3-butadione, 2-isonitrosoacetophenone and an imine derived from the oxime. It was concluded that degradation occurred through nucleophilic attack by a hydroxide or oxime anion to produce cyanide, as well as a nitrogen atom rearrangement similar to Beckmann rearrangement. The stability of the oxime in organic solvents is most likely due to the lack of water, and specifically hydroxide ions. The reaction between oxime and organo-phosphate to produce cyanide ions requires hydroxide ions, and therefore pure organic solvents are not compatible with the current micro-sensor electrochemistry. By combining a concentrated organic oxime solution with the basic aqueous buffer just prior to being used in the detection process, oxime degradation can be avoided while preserving the original electrochemical detection scheme. Based on beaker cell experiments with selective cyanide sensitive electrodes, ethanol was chosen as the best organic solvent due to its stabilizing effect on the oxime, minimal interference with the aqueous electrochemistry, and compatibility with the current microsensor material (PMMA). Further studies showed that ethanol had a small effect on micro-sensor performance by reducing the rate of cyanide production and decreasing the overall response time. To avoid incomplete mixing of the aqueous and organic solutions, they were pre-mixed externally at a 10:1 ratio, respectively. To adapt the microsensor design to allow for mixing to take place within the device, a small serpentine channel component was fabricated with the same dimensions and material as the original sensor. This allowed for seamless integration of the microsensor with the serpentine mixing channel. Mixing in the serpentine microchannel takes place via diffusion. Both detector potential response and diffusional mixing improve with increased liquid residence time, and thus decreased liquid flowrate. Micromixer performance was studies at a 10:1 aqueous buffer to organic solution flow rate ratio, for a total rate of 5.5 μL/min. It was found that the sensor response utilizing the integrated micromixer was nearly identical to the response when the solutions were premixed and fed at the same rate.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Este trabalho teve como objectivo inicial o estudo de processos oxidativos avançados de forma a remediar e tratar águas contaminadas por pesticidas. No entanto, ao longo do trabalho experimental, constatou-se que os produtos resultantes da degradação de pesticidas são muitas vezes mais tóxicos do que os compostos que lhes deram origem e que, por isso, degradar um composto nem sempre é o melhor para o ambiente. Assim, neste trabalho, procurou-se estudar o processo de degradação com o objectivo de minimizar o impacto ambiental dos pesticidas na água e no ambiente em geral. A parte experimental deste trabalho foi dividida em duas etapas, sendo que, em ambas, a voltametria de onda quadrada e a espectrofotometria de UV/Vis foram os métodos de análise utilizados, para acompanhar o processo de fotodegradação. Na primeira etapa estudou-se a relação entre a estrutura química dos pesticidas MCPA, MCPP, 2.4-D e Dicloroprop e a sua fotodegradação. Soluções aquosas dos pesticidas enunciados foram submetidas a irradiação UV/vis, com incrementos variáveis de tempo de irradiação. Os resultados obtidos, nesta etapa, permitiram constatar diferenças na percentagem de degradação dos diferentes pesticidas. Dos pesticidas estudados verificou-se uma maior fotodegradação para o MCPA e MCPP seguido do Dicloroprop e finalmente o 2.4-D que se degradou menos. Os dados obtidos sugerem que a fotodegradação destes pesticidas está intimamente ligada com a estrutura das moléculas. A presença de um maior número de grupos cloro ligados ao anel aromático nos pesticidas 2,4-D e Dicloroprop faz com que estes sejam mais estáveis e por isso se degradam menos que o MCPA e o MCPP. Por outro lado, o facto de o 2,4-D apresentar um potencial de oxidação mais elevado do que o Dicloroprop, faz com que este seja mais difícil de degradar, o que justifica a diferença entre os dois. Desta forma, foi possível concluir que a estrutura dos pesticidas condiciona o processo de degradação, como esperado. Na segunda etapa, estudou-se a estabilização dos pesticidas MCPA e MCPP após encapsulação, com 2-hidroxipropil-β-ciclodextrina (HP-β-CD), em água desionizada e em água do rio. Para tal, submeteram-se as soluções aquosas dos pesticidas com e sem ciclodextrina, a irradiação UV/vis, também com incrementos variáveis de tempo. No caso do MCPA verificou-se que, tanto para água desionizada como para água do rio, que este herbicida encapsulado se degrada bastante menos do que o MCPA livre. O encapsulamento permitiu reduzir quase para metade a taxa de fotodegradação. Assim, confirmou-se que a HP-β-CD permite estabilizar este pesticida, tornando-o mais resistente à fotodegradação. Desta forma, originam-se menos produtos de degradação, os quais podem ser mais tóxicos, e reduz-se de o impacto ambiental deste herbicida. Verificou-se também que o MCPA livre se degrada mais em água do rio do que em água desionizada, provavelmente devido à matéria orgânica presente nesta água, que promove o processo de degradação. No que respeita ao MCPP também se constatou que este herbicida se degrada menos encapsulado do que livre, em água desionizada e em água do rio. Neste caso, conseguiu-se reduzir pouco a taxa de fotodegradação, mas, ainda assim se verifica uma estabilização deste pesticida através do encapsulamento. No entanto, tornou-se mais evidente a estabilização do MCPP após encapsulação em água do rio, já que apresenta uma taxa de fotodegradação menor. Este facto demonstra que a HP-β-CD permite estabilizar também este pesticida, tornando-o mais resistente à fotodegradação, e reduzindo seu impacto ambiental.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The forensic toxicologist faces challenges in the detection of drugs and poisons in biological samples due to transformations which occur both during life and after death. For example, changes can result from drug metabolism during life or from the use of formalin solution for post mortem embalming purposes. The former requires the identification of drug metabolites and the latter the identification of chemical reaction products in order to know which substances had been administered. The work described in this thesis was aimed at providing ways of tackling these challenges and was divided into two parts. Part 1 investigated the use of in vitro drug metabolism by human liver microsomes (HLM) to obtain information on drug metabolites and Part 2 investigated the chemical reactions of drugs and a carbamate pesticide with formalin solution and formalin-blood. The initial aim of part I was to develop an in vitro metabolism method using HLM, based on a literature review of previous studies of this type. MDMA was chosen as a model compound to develop the HLM method because its metabolism was known and standards of its metabolites were commercially available. In addition, a sensitive and selective method was developed for the identification and quantitation of hydrophilic phase I drug metabolites using LC/MS/MS with a conventional reverse-phase (C18) column. In order to obtain suitable retention factors for polar drug metabolites on this column, acetyl derivatives were evaluated for converting the metabolites to more lipophilic compounds and an optimal separation system was developed. Acetate derivatives were found to be stable in the HPLC mobile phase and to provide good chromatographic separation of the target analytes. In vitro metabolism of MDMA and, subsequently, of other drugs involved incubation of 4 µg drug substance in pH 7.4 buffer with an NADPH generating system (NGS) at 37oC for 90 min with addition of more NGS after 30 min. The reaction was stopped at 90 min by the addition of acetonitrile before extraction of the metabolites. Acetate derivatives of MDMA metabolites were identified by LC/MS/MS using multiple reaction monitoring (MRM). Three phase I metabolites (both major and minor metabolites) of MDMA were detected in HLM samples. 3,4-dihydroxy-methamphetamine and 4-hydroxy-3-methoxymethamphetamine were found to be major metabolites of MDMA whereas 3,4-methylenedioxyamphetamine was found to be a minor metabolite. Subsequently, ten MDMA positive urines were analysed to compare the metabolite patterns with those produced by HLM. An LC/MS method for MDMA and its metabolites in urine samples was developed and validated. The method demonstrated good linearity, accuracy and precision and insignificant matrix effects, with limits of quantitation of 0.025 µg/ml. Moreover, derivatives of MDMA and its metabolites were quantified in all 10 positive human urine samples. The urine metabolite pattern was found to be similar to that from HLM. The second aim of Part 1 was to use the HLM system to study the metabolism of some new psychoactive substances, whose misuse worldwide has necessitated the development of analytical methods for these drugs in biological specimens. Methylone and butylone were selected as representative cathinones and para-methoxyamphetamine (PMA) was chosen as a representative ring-substituted amphetamine, because of the involvement of these drugs in recent drug-related deaths, because of a relative lack of information on their metabolism, and because reference standards of their metabolites were not commercially available. An LC/MS/MS method for the analysis of methylone, butylone, PMA and their metabolites was developed. Three phase I metabolites of methylone and butylone were detected in HLM samples. Ketone reduction to β-OH metabolites and demethylenation to dihydroxy-metabolites were found to be major phase I metabolic pathways of butylone and methylone whereas N-demethylation to nor-methylone and nor-butylone were found to be minor pathways. Also, demethylation to para-hydroxyamphetamine was found to be a major phase I metabolic pathway of PMA whereas β-hydroxylation to β-OH-PMA was found to be a minor pathway. Formaldehyde is used for embalming, to reduce decomposition and preserve cadavers, especially in tropical countries such as Thailand. Drugs present in the body can be exposed to formaldehyde resulting in decreasing concentrations of the original compounds and production of new substances. The aim of part II of the study was to evaluate the in vitro reactions of formaldehyde with selected drug groups including amphetamines (amphetamine, methamphetamine and MDMA), benzodiazepines (alprazolam and diazepam), opiates (morphine, hydromorphone, codeine and hydrocodone) and with a carbamate insecticide (carbosulfan). The study would identify degradation products to serve as markers for the parent compounds when these were no longer detectable. Drugs standards were spiked in 10% formalin solution and 10% formalin blood. Water and whole blood without formalin were used for controls. Samples were analysed by LC/MS/MS at different times from the start, over periods of up to 30 days. Amphetamine, methamphetamine and MDMA were found to rapidly convert to methamphetamine, DMA and MDDMA respectively, in both formalin solution and formalin blood, confirming the Eschweiler-Clarke reaction between amine-containing compounds and formaldehyde. Alprazolam was found to be unstable whereas diazepam was found to be stable in both formalin solution and water. Both were found to hydrolyse in formalin solution and to give open-ring alprazolam and open-ring diazepam. Other alprazolam conversion products attached to paraformaldehyde were detected in both formalin solution and formalin blood. Morphine and codeine were found to be more stable than hydromorphone and hydrocodone in formalin solution. Conversion products of hydromorphone and hydrocodone attached to paraformaldehyde were tentatively identified in formalin solution. Moreover, hydrocodone and hydromorphone rapidly decreased within 24 h in formalin blood and could not be detected after 7 days. Carbosulfan was found to be unstable in formalin solution and was rapidly hydrolysed within 24 h, whereas in water it was stable up to 48 h. Carbofuran was the major degradation product, plus smaller amounts of other products, 3-ketocarbofuran and 3-hydrocarbofuran. By contrast, carbosulfan slowly hydrolysed in formalin-blood and was still detected after 15 days. It was concluded that HLM provide a useful tool for human drug metabolism studies when ethical considerations preclude their controlled administration to humans. The use of chemical derivatisation for hydrophilic compounds such as polar drug metabolites for analysis by LC/MS/MS with a conventional C18 column is effective and inexpensive, and suitable for routine use in the identification and quantitation of drugs and their metabolites. The detection of parent drugs and their metabolites or conversion and decomposition products is potentially very useful for the interpretation of cases in forensic toxicology, especially when the original compounds cannot be observed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

International audience

Relevância:

100.00% 100.00%

Publicador:

Resumo:

La spectrométrie de masse mesure la masse des ions selon leur rapport masse sur charge. Cette technique est employée dans plusieurs domaines et peut analyser des mélanges complexes. L’imagerie par spectrométrie de masse (Imaging Mass Spectrometry en anglais, IMS), une branche de la spectrométrie de masse, permet l’analyse des ions sur une surface, tout en conservant l’organisation spatiale des ions détectés. Jusqu’à présent, les échantillons les plus étudiés en IMS sont des sections tissulaires végétales ou animales. Parmi les molécules couramment analysées par l’IMS, les lipides ont suscité beaucoup d'intérêt. Les lipides sont impliqués dans les maladies et le fonctionnement normal des cellules; ils forment la membrane cellulaire et ont plusieurs rôles, comme celui de réguler des événements cellulaires. Considérant l’implication des lipides dans la biologie et la capacité du MALDI IMS à les analyser, nous avons développé des stratégies analytiques pour la manipulation des échantillons et l’analyse de larges ensembles de données lipidiques. La dégradation des lipides est très importante dans l’industrie alimentaire. De la même façon, les lipides des sections tissulaires risquent de se dégrader. Leurs produits de dégradation peuvent donc introduire des artefacts dans l’analyse IMS ainsi que la perte d’espèces lipidiques pouvant nuire à la précision des mesures d’abondance. Puisque les lipides oxydés sont aussi des médiateurs importants dans le développement de plusieurs maladies, leur réelle préservation devient donc critique. Dans les études multi-institutionnelles où les échantillons sont souvent transportés d’un emplacement à l’autre, des protocoles adaptés et validés, et des mesures de dégradation sont nécessaires. Nos principaux résultats sont les suivants : un accroissement en fonction du temps des phospholipides oxydés et des lysophospholipides dans des conditions ambiantes, une diminution de la présence des lipides ayant des acides gras insaturés et un effet inhibitoire sur ses phénomènes de la conservation des sections au froid sous N2. A température et atmosphère ambiantes, les phospholipides sont oxydés sur une échelle de temps typique d’une préparation IMS normale (~30 minutes). Les phospholipides sont aussi décomposés en lysophospholipides sur une échelle de temps de plusieurs jours. La validation d’une méthode de manipulation d’échantillon est d’autant plus importante lorsqu’il s’agit d’analyser un plus grand nombre d’échantillons. L’athérosclérose est une maladie cardiovasculaire induite par l’accumulation de matériel cellulaire sur la paroi artérielle. Puisque l’athérosclérose est un phénomène en trois dimension (3D), l'IMS 3D en série devient donc utile, d'une part, car elle a la capacité à localiser les molécules sur la longueur totale d’une plaque athéromateuse et, d'autre part, car elle peut identifier des mécanismes moléculaires du développement ou de la rupture des plaques. l'IMS 3D en série fait face à certains défis spécifiques, dont beaucoup se rapportent simplement à la reconstruction en 3D et à l’interprétation de la reconstruction moléculaire en temps réel. En tenant compte de ces objectifs et en utilisant l’IMS des lipides pour l’étude des plaques d’athérosclérose d’une carotide humaine et d’un modèle murin d’athérosclérose, nous avons élaboré des méthodes «open-source» pour la reconstruction des données de l’IMS en 3D. Notre méthodologie fournit un moyen d’obtenir des visualisations de haute qualité et démontre une stratégie pour l’interprétation rapide des données de l’IMS 3D par la segmentation multivariée. L’analyse d’aortes d’un modèle murin a été le point de départ pour le développement des méthodes car ce sont des échantillons mieux contrôlés. En corrélant les données acquises en mode d’ionisation positive et négative, l’IMS en 3D a permis de démontrer une accumulation des phospholipides dans les sinus aortiques. De plus, l’IMS par AgLDI a mis en évidence une localisation différentielle des acides gras libres, du cholestérol, des esters du cholestérol et des triglycérides. La segmentation multivariée des signaux lipidiques suite à l’analyse par IMS d’une carotide humaine démontre une histologie moléculaire corrélée avec le degré de sténose de l’artère. Ces recherches aident à mieux comprendre la complexité biologique de l’athérosclérose et peuvent possiblement prédire le développement de certains cas cliniques. La métastase au foie du cancer colorectal (Colorectal cancer liver metastasis en anglais, CRCLM) est la maladie métastatique du cancer colorectal primaire, un des cancers le plus fréquent au monde. L’évaluation et le pronostic des tumeurs CRCLM sont effectués avec l’histopathologie avec une marge d’erreur. Nous avons utilisé l’IMS des lipides pour identifier les compartiments histologiques du CRCLM et extraire leurs signatures lipidiques. En exploitant ces signatures moléculaires, nous avons pu déterminer un score histopathologique quantitatif et objectif et qui corrèle avec le pronostic. De plus, par la dissection des signatures lipidiques, nous avons identifié des espèces lipidiques individuelles qui sont discriminants des différentes histologies du CRCLM et qui peuvent potentiellement être utilisées comme des biomarqueurs pour la détermination de la réponse à la thérapie. Plus spécifiquement, nous avons trouvé une série de plasmalogènes et sphingolipides qui permettent de distinguer deux différents types de nécrose (infarct-like necrosis et usual necrosis en anglais, ILN et UN, respectivement). L’ILN est associé avec la réponse aux traitements chimiothérapiques, alors que l’UN est associé au fonctionnement normal de la tumeur.