980 resultados para Estimulantes da Saliva
Resumo:
This study evaluated the influence of a cola-type soft drink and a soy-based orange juice on the surface and subsurface erosion of primary enamel, as a function of the exposure time. Seventy-five primary incisors were divided for microhardness test (n=45) or scanning electron microscopy (SEM) analysis (n=30). The specimens were randomly assigned to 3 groups: 1 - artificial saliva (control); 2 - cola-type soft drink; and 3 - soy-based orange juice. Immersion cycles in the beverages were undertaken under agitation for 5 min, 3 times a day, during 60 days. Surface microhardness was measured at 7, 15, 30, 45 and 60 days. After 60 days, specimens were bisected and subsurface microhardness was measured at 30, 60, 90, 120, 150 and 200 µm from the surface exposed. Data were analyzed by ANOVA and Tukey’s test (a=0.05). Groups 2 and 3 presented similar decrease of surface microhardness. Regarding subsurface microhardness, group 2 presented the lowest values. SEM images revealed that after 60 days the surfaces clearly exhibited structural loss, unlike those immersed in artificial saliva. It may be concluded that erosion of the surfaces exposed to the cola-type soft drink was more accentuated and directly proportional to the exposure time.
Resumo:
This study evaluated the effect of surface sealant on the translucency of composite resin immersed in different solutions. The study involved the following materials: Charisma, Fortify and coffee, Coca-Cola®, tea and artificial saliva as solutions. Sixty-four specimens (n = 8) were manufactured and immersed in artificial saliva at 37 ± 1 °C. Samples were immersed in the solutions for three times a day and re-immersed in artificial saliva until the translucency readings. The measurements were carried out at nine times: T1 - 24 hours after specimen preparation, T2 - 24 hours after immersion in the solutions, T3 - 48 hours and T4 to T9 - 7, 14, 21, 30, 60 and 90 days, respectively, after immersion. The translucency values were measured using a JOUAN device. The results were subjected to ANOVA and Tukey's test at 5%. The surface sealant was not able to protect the composite resin against staining, the coffee showed the strongest staining action, followed by tea and regarding immersion time, a significant alteration was noted in the translucency of composite resin after 21 days.
Resumo:
OBJECTIVE: This study evaluated the influence of light sources and immersion media on the color stability of a nanofilled composite resin. MATERIAL AND METHODS: Conventional halogen, high-power-density halogen and high-power-density light-emitting diode (LED) units were used. There were 4 immersion media: coffee, tea, Coke® and artificial saliva. A total of 180 specimens (10 mm x 2 mm) were prepared, immersed in artificial saliva for 24 h at 37±1ºC, and had their initial color measured with a spectrophotometer according to the CIELab system. Then, the specimens were immersed in the 4 media during 60 days. Data from the color change and luminosity were collected and subjected to statistical analysis by the Kruskall-Wallis test (p<0.05). For immersion time, the data were subjected to two-way ANOVA test and Fisher's test (p<0.05). RESULTS: High-power-density LED (ΔE=1.91) promoted similar color stability of the composite resin to that of the tested halogen curing units (Jet Lite 4000 plus - ΔE=2.05; XL 3000 - ΔE=2.28). Coffee (ΔE=8.40; ΔL=-5.21) showed the highest influence on color stability of the studied composite resin. CONCLUSION: There was no significant difference in color stability regardless of the light sources, and coffee was the immersion medium that promoted the highest color changes on the tested composite resin.
Resumo:
FUNDAMENTO: A doença periodontal representa risco à gestante portadora de valvopatia reumática, seja para contrair endocardite infecciosa, seja por propiciar complicações obstétricas. OBJETIVO: Estudar a frequência da doença periodontal em portadoras de valvopatia reumática durante a gravidez. MÉTODOS: Foram estudadas 140 gestantes, comparáveis quanto a idade e o nível socioeconômico, divididas em: 70 portadoras de doença valvar reumática e 70 mulheres saudáveis. Todas se submeteram a: 1) avaliação clínica odontológica que incluiu a análise dos seguintes parâmetros: 1.1) profundidade à sondagem, 1.2) distância da linha esmalte-cemento à margem gengival, 1.3) nível clínico de inserção, 1.4) índice de sangramento, 1.5) índice de placa bacteriana, e, 1.6) comprometimento de furca; e, 2) exame microbiológico nas amostras de saliva e do cone que considerou o controle positivo para as cepas das bactérias Porphyromonas gingivalis, Tannerella forsithia e Aggregobacter actinomycetemcomitans. RESULTADOS: A lesão valvar mitral foi prevalente (65 casos = 92,8%) dentre as gestantes cardiopatas. A comparação entre os grupos mostrou não haver diferenças entre idade e a paridade, e embora tenham sido verificadas diferenças entre as medidas da distância da linha esmalte-cemento à margem gengival (p = 0,01) e o índice de placa (p=0,04), a frequência da doença periodontal identificada em 20 (14,3%) gestantes, não foi diferente entre os grupos (p = 0,147). O exame microbiológico mostrou uma proporção maior da bactéria P. gingivalis na saliva de gestantes saudáveis (p = 0,004). CONCLUSÃO: O estudo clínico e microbiológico periodontal durante a gravidez demonstrou igual frequência da doença periodontal em portadoras de valvopatia reumática quando comparada às mulheres saudáveis.
Resumo:
Frequent use of Xylitol may decrease the S. mutans levels. However, very little is known about whether this effect on the levels of cariogenic bacteria is maintained after the interruption of short-term usage of xylitol. This study aimed at evaluating changes in mutans streptococci (MS) salivary levels after using a chewing gum containing xylitol. Twelve volunteers harboring > 10(5) CFU MS/ml saliva levels were asked to chew Happydent-xylit® for 5 minutes, 5 X/day, for 30 days. Saliva samples were collected at baseline, at 30 days after xylitol usage began, and at 30 days beyond its interruption. MS salivary levels were estimated. The average salivary levels of MS in the ten subjects who completed the study were 13.17 (NL-CFU) at baseline (A). After the 30 days experimental period (B), this average decreased to 9.45 (NL-CFU). Nine of ten subjects studied showed a reduction in MS salivary levels in relation to baseline, whereas salivary levels were maintained in the remaining subject. At thirty days beyond the interruption of xylitol usage (C), the average levels of MS were still reduced to 10.31 (NL-CFU). Multiple sample comparison using the Bonferroni test revealed that the decrease in MS levels observed from baseline (A) to the time immediately after 30 days of xylitol usage (B) was statistically significant (p < 0.05), and those levels were still decreased between baseline and 30 days beyond the interruption of xylitol usage (C). So, the use of xylitol induced a reduction in MS salivary levels after a short period of usage which persisted beyond its interruption.
Resumo:
This study aimed at comparing amounts of nickel (Ni) and chromium (Cr) released from brackets from different manufacturers in simulated oral environments. 280 brackets were equally divided into 7 groups according to manufacturer. 6 groups of brackets were stainless steel, and 1 group of brackets was made of a cobalt-chromium alloy with low Ni content (0.5%). International standard ISO 10271/2001 was applied to provide test methods. Each bracket was immersed in 0.5 ml of synthetic saliva (SS) or artificial plaque fluid (PF) over a period of 28 days at 37ºC. Solutions were replaced every 7 days, and were analyzed by spectrometry. The Kruskal-Wallis test was applied. Amounts of Ni release in SS (µg L-1 per week) varied between groups from "bellow detection limits" to 694, and from 49 to 5,948.5 in PF. The group of brackets made of cobalt-chromium alloy, with the least nickel content, did not release the least amounts of Ni. Amounts of Cr detected in SS and in PF (µg L-1 per week) were from 1 to 10.4 and from 50.5 to 8,225, respectively. It was therefore concluded that brackets from different manufacturers present different corrosion behavior. Further studies are necessary to determine clinical implications of the findings.
Resumo:
The aim of this study was to verify whether screw abutment lubrication can generate higher preload values compared to non-lubricated screws, a titanium abutment was screwed onto an implant analog and scanned with the Procera System to generate 20 zirconia abutments. MKIII Brånemark implants were clamped to a precision torque device, and the abutments were distributed in dry and wet groups with 10 specimens each. In the wet groups, the inner threads of the implants were filled with artificial saliva. All abutments were fastened with a Torqtite screw under 32 Ncm. Ten detorque measurements were performed per group pushing the reverse button of the Torque controller soon after screw tightening with values registered. The mean detorque values were calculated and compared by a Student's t test (?=0.05). The wet condition presented significantly higher mean detorque than the dry condition (31.5 ± 1.2 versus 27.5 ± 1.5 Ncm, respectively; p=0.0000024). In conclusion, there was always a loss in the initial torque values when the removal torque was measured under both conditions. The wet condition presented higher mean torque than the dry condition. Better preload values were established in the wet group, suggesting that the abutment screw must be lubricated in saliva to avoid further loosening.
Resumo:
Objetivou-se avaliar os efeitos da ingestão diária de quatro níveis de fósforo (8, 12, 15 e 18 g) sobre o metabolismo de macrominerais (P, Ca, Mg, Na, K e S), incluindo a ingestão, a concentração no rúmen, a taxa de passagem do líquido ruminal, a excreção nas fezes e a disponibilidade aparente. Utilizaram-se quatro bubalinos adultos com fístulas ruminais em delineamento quadrado latino (4 × 4) com dieta total constituída de cana-de-açúcar como volumoso (85%) e concentrado formulado com um dos níveis de fósforo. Os níveis de fósforo não ocasionaram diferença significativa na concentração mineral no rúmen de nenhum mineral estudado. A concentração média de fósforo no conteúdo ruminal foi de 0,98% na matéria seca, enquanto o teor de fósforo nas rações variou de 0,12 a 0,34%, comprovando alta reciclagem de fósforo pela saliva. Níveis crescentes de fósforo na dieta, variando de 8 a 18 g/animal/dia, não influenciam as disponibilidades de cálcio e magnésio. Com o nível de fósforo de 15 g/dia, houve melhor utilização do fósforo da dieta. A ingestão de níveis crescentes de fósforo em g/kg0,75 (X) promoveu aumento linear na excreção fecal desse mineral em g/kg0,75 (Y) e baixos valores de disponibilidade do fósforo, que pode ser estimado pela equação Y = 0,03 + 0,610X, o que indica deficiência desse elemento mineral na dieta para o metabolismo animal.
Resumo:
Objective. To assess the relationship between cortisol concentrations in the last trimester of pregnancy and systemic vascular resistance — SVR in childhood. Materials and methods. This study is part of a cohort involving 130 Brazilian pregnant women and their children, ages 5 to 7 years. Maternal cortisol was determined in saliva by an enzyme immunoassay utilizing the mean concentration of 9 samples of saliva (3 in each different day), collected at the same time, early in the morning. SVR was assessed by the HDI/PulseWave CR-2000 Cardiovascular Profiling System®. Socioeconomic and demographic characteristics and life style factors were determined by a questionnaire. The nutritional status of the women and children was assessed by the body mass index — BMI. The association between maternal cortisol and SVR in childhood was calculated by multivariate linear regression analysis. Results.There were statistically significant associations between maternal cortisol and SVR (p = 0.043) and BMI-z score of the children (p = 0.027), controlling for maternal BMI, birth weight, age, and gender of the children. Conclusion. As far as we know this is the first study in the literature assessing the association between cortisol concentrations in pregnancy and SVR in childhood. Overall, the data suggest that exposure to excess glucocorticoid in the prenatal period is associated to vascular complications in childhood, predisposing to cardiovascular diseases in later life
Resumo:
Bloodsucking parasites such as ticks have evolved a wide variety of immunomodulatory proteins that are secreted in their saliva, allowing them to feed for long periods of time without being detected by the host immune system. One possible strategy used by ticks to evade the host immune response is to produce proteins that selectively bind and neutralize the chemokines that normally recruit cells of the innate immune system that protect the host from parasites. We have identified distinct cDNAs encoding novel chemokine binding proteins (CHPBs), which we have termed Evasins, using an expression cloning approach. These CHBPs have unusually stringent chemokine selectivity, differentiating them from broader spectrum viral CHBPs. Evasin-1 binds to CCL3, CCL4, and CCL18; Evasin-3 binds to CXCL8 and CXCL1; and Evasin-4 binds to CCL5 and CCL11. We report the characterization of Evasin-1 and -3, which are unrelated in primary sequence and tertiary structure, and reveal novel folds. Administration of recombinant Evasin-1 and - 3 in animal models of disease demonstrates that they have potent antiinflammatory properties. These novel CHBPs designed by nature are even smaller than the recently described single-domain antibodies (Hollinger, P., and P. J. Hudson. 2005. Nat. Biotechnol. 23: 1126-1136), and may be therapeutically useful as novel antiinflammatory agents in the future.
Resumo:
Background: The use of laser irradiation for dental surface treatment may increase tooth-composite bond strength. Its use on bleached teeth may decrease the waiting time between bleaching and restorative procedures. Objective: This study aimed to evaluate the bond strength between a composite resin and bovine enamel bleached with 35% hydrogen peroxide and etched with Er:YAG laser. Materials and Methods: Thirty bovine teeth were randomly divided into six groups (n = 5): G1, unbleached and restored 24 h after storage in artificial saliva, etching with 35% phosphoric acid (PA) (control); G2, unbleached and restored 24 h after storage in artificial saliva, etching with Er:YAG laser and 35% PA; G3, bleached and restored immediately afterward, etching with 35% PA; G4, bleached and restored 24 h after bleaching, etching with 35% PA; G5, bleached and restored immediately afterward, etching with Er:YAG and 35% PA laser; G6, bleached and restored 24 h after bleaching, etching with Er:YAG laser and 35% PA. Bond strength was quantitatively evaluated by microtensile test (1.0 mm/min). Data were submitted to statistical analysis using ANOVA and Tukey tests (alpha - 0.05). Results: Bond strength values (MPa) were G1, 26.17 +/- 4.44; G2, 28.87 +/- 3.94; G3, 17.25 +/- 4.58; G4, 21.93 +/- 5.02; G5, 16.69 +/- 2.31; and G6, 29.06 +/- 8.31. There was no statistically significant difference among groups G1, G2, and G6 (p - 0.119), which presented higher bond strength than group G4, followed by groups G3 and G5. Conclusion: Er:YAG irradiation of bleached surfaces may favor bonding procedures when performed 24 h after bleaching.
Resumo:
The common consequences of radiotherapy (RT) to the head and neck are oral mucositis, xerostomia, and severe pain. The aim of this study was to verify how laser phototherapy (LPT) used for oral mucositis could influence xerostomia symptoms and hyposalivation of patients undergiong RT. Patients were divided into two groups: 12 individuals receiving three laser irradiations per week (G1) and 10 patients receiving one laser irradiation per week (G2). A diode laser (660 nm, 6 J/cm(2), 0.24 J, 40mW) was used until completely healing of the lesions or the end of the RT. At the first and last laser sessions, whole resting and stimulated saliva were collected, and questionnaires were administered. According to Wilcoxon and Student statistical test, xerostomia for G1 was lower than for G2 (p<0.05), and salivary flow rate was no different before and after RT, except for stimulated collection of G2, which was lower (p<0.05). Our results suggest that LPT can be beneficial as an auxiliary therapy for hypofunction of salivary glands.
Resumo:
Objective: This in vitro study aimed to analyze the influence of neodymium-doped yttrium aluminum garnet (Nd:YAG) laser irradiation on the efficacy of titanium tetrafluoride (TiF(4)) and sodium fluoride (NaF) varnishes and solutions to protect enamel against erosion. Background data: The effect of Nd:YAG laser irradiation on NaF and AmF was analyzed; however, there is no available data on the interaction between Nd:YAG laser irradiation and TiF(4). Methods: Bovine enamel specimens were pre-treated with NaF varnish, TiF(4) varnish, NaF solution, TiF(4) solution, placebo varnish, Nd:YAG (84.9 J/cm(2)), Nd:YAG prior to or through NaF varnish, Nd:YAG prior to or through TiF(4) varnish, Nd:YAG prior to or through NaF solution, Nd:YAG prior to or through TiF(4) solution, and Nd:YAG prior to or through placebo varnish. Controls remained untreated. Ten specimens in each group were then subjected to an erosive demineralization (Sprite Zero, 4x90 s/day) and remineralization (artificial saliva, between the erosive cycles) cycling for 5 days. Enamel loss was measured profilometrically (mu m). Additionally, treated but non-eroded specimens were additionally analyzed by scanning electron microscope (SEM) (each group n-2). The data were statistically analyzed by ANOVA and Tukey's post-hoc test (p < 0.05). Results: Only TiF(4) varnish (1.8 +/- 0.6 mu m), laser prior to TiF(4) varnish (1.7 +/- 0.3 mu m) and laser prior to TiF(4) solution (1.4 +/- 0.3 mu m) significantly reduced enamel erosion compared to the control (4.1 +/- 0.6 mu m). SEM pictures showed that specimens treated with TiF(4) varnish presented a surface coating. Conclusions: Nd:YAG laser irradiation was not effective against enamel erosion and it did not have any influence on the efficacy of F, except for TiF(4) solution. On the other hand, TiF(4) varnish protected against enamel erosion, without the influence of laser irradiation.
Resumo:
Aggressive periodontitis is characterized by a rapid and severe periodontal destruction in young systemically healthy subjects. A greater prevalence is reported in Africans and African descendent groups than in Caucasians and Hispanics. We first fine mapped the interval 1q24.2 to 1q31.3 suggested as containing an aggressive periodontitis locus. Three hundred and eighty-nine subjects from 55 pedigrees were studied. Saliva samples were collected from all subjects, and DNA was extracted. Twenty-one single nucleotide polymorphisms were selected and analyzed by standard polymerase chain reaction using TaqMan chemistry. Non-parametric linkage and transmission distortion analyses were performed. Although linkage results were negative, statistically significant association between two markers, rs1935881 and rs1342913, in the FAM5C gene and aggressive periodontitis (p = 0.03) was found. Haplotype analysis showed an association between aggressive periodontitis and the haplotype A-G (rs1935881-rs1342913; p = 0.009). Sequence analysis of FAM5C coding regions did not disclose any mutations, but two variants in conserved intronic regions of FAM5C, rs57694932 and rs10494634, were found. However, these two variants are not associated with aggressive periodontitis. Secondly, we investigated the pattern of FAM5C expression in aggressive periodontitis lesions and its possible correlations with inflammatory/immunological factors and pathogens commonly associated with periodontal diseases. FAM5C mRNA expression was significantly higher in diseased versus healthy sites, and was found to be correlated to the IL-1 beta, IL-17A, IL-4 and RANKL mRNA levels. No correlations were found between FAM5C levels and the presence and load of red complex periodontopathogens or Aggregatibacter actinomycetemcomitans. This study provides evidence that FAM5C contributes to aggressive periodontitis.
Resumo:
Objective: Previous investigations have demonstrated improved enamel demineralization resistance after laser irradiation. Due to the possibility of a synergistic effect between laser and fluoride, this study investigated the effect of fluoridated agents and Nd:YAG irradiation separately and in combination on enamel resistance to erosion. Methods: One hundred bovine enamel blocks were randomly divided into 10 groups: G1, untreated (control); G2, acidic phosphate fluoride (APF) (1.23% F) for 4 min; G3, fluoride varnish for 6 h (NaF, 2.26%); G4, 0.5 W Nd: YAG laser (250 mm pulse width, 10 Hz, 35 J/cm(2), with uniform velocity for 30 sec in each application); G5, 0.75 W Nd:YAG laser (52.5 J/cm(2)); G6, 1.0 W Nd:YAG laser (70 J/cm(2)); G7, APF + 0.75 W Nd:YAG laser; G8, 0.75 W Nd:YAG laser + APF; G9, fluoride varnish + 0.75 W Nd:YAG laser; and G10, 0.75 W Nd:YAG laser + fluoride varnish. During 10 d the erosive cycle was conducted by immersion of the blocks in Sprite light for 1 min, followed by immersion in artificial saliva for 59 min. This procedure was consecutively repeated four times per day. In each day, during the remaining 20 h, the blocks were maintained in artificial saliva. The wear was evaluated by profilometry (days 5 and 10). Data were tested by two-way ANOVA and Bonferroni's tests (p < 0.05). Results: The mean wear at days 5 and 10 was, respectively: G1, 1.83 and 2.67 mu m; G2, 1.04 and 2.60 mu m; G3, 1.03 and 2.48 mu m; G4, 1.13 and 2.47 mu m; G5, 1.07 and 2.44 mu m; G6, 1.0 and 2.35 mu m; G7, 0.75 and 2.27 mu m; G8, 0.80 and 2.12 mu m; G9, 0.76 and 2.47 mu m; and G10, 1.09 and 2.46 mu m. At day 5, all the experimental groups presented significant lesser wear when compared to control group. However, at 10 d, only G7 and G8 were still different from control. Conclusions: The association between APF application and laser irradiation seems to be an alternative preventive measure against dental erosion.