494 resultados para Endoprothèse (stent)
Resumo:
Purpose: Best percutaneous treatment strategy for lesions in coronary bifurcations is an ongoing subject of debate. There is limited data that analyses the effect of the different bifurcation strategies on coronary flow. Our aim is to evaluate the influence of different bifurcation stenting strategies on hemodynamic parameters, both in the main vessel (MV) and side branch (SB).
Resumo:
A simple analytical expression has been derived to calculate the characteristics of a wave that reflects at a stent implanted in a uniform vessel. The stent is characterized by its length and the wave velocity in the stented region. The reflected wave is proportional to the time derivative of the incident wave. The reflection coefficient is a small quantity of the order of the length of the stent divided by the wavelength of the unstented vessel. The results obtained coincide with those obtained numerically by Charonko et al. The main simplifications used are small amplitude of the waves so that equations can be linearized and that the length of the stent is small enough so that the values of the wave functions are nearly uniform along the stent. Both assumptions hold in typical situations.
Resumo:
Los avances en la era endovascular han causado una revolución en el abordaje de la estenosis carotidea. La irrupción del abordaje transfemoral y transcervical ha hecho que la comunidad científica nos replanteemos las indicaciones terapeúticas en pacientes con estenosis carotidea sintomática o asintomática. Aunque los resultados del abordaje transfemoral mejoraron con la introducción de los sistemas de neuroprotección, un abundante número de estudios randomizados han sido dirigidos para comparar stent transfemoral frente a la endarterectomia. Endarterectomia frente a angioplastia en pacientes con estenosis severa sintomatica(EVA-3S), angioplastia con stent y neuroprotección frente a endarterectomia (SPACE), Angioplastia carotidea y vertebral (CAVATAS), revascularización carotidea mediante stent versus endarterectomia (CREST) estudio internacional carotideo (ICSS) todos fallaron en demostrar una ventaja global del stent transfemoral frente a la endarterectomia. El abordaje transcervical surge por tanto como opción segura de tratamiento, con buenos resultados clínicos iniciales, eliminando así algunas de las complicaciones del acceso transfemoral. Existe hasta la fecha una falta de estudios comparativos de morbimortalidad entre las tres opciones terapeúticas. Además, dado el elevado número de pacientes candidatos a ellos, es necesario una análisis de resultados y supervivencia de los mismos, asi como un análisis de costes relativos y coste-efectividad que podría tener importantes implicaciones en las políticas de salud y en las guias de tratamiento...
Resumo:
This dissertation presents dynamic flow experiments with fluorescently labeled platelets to allow for spatial observation of wall attachment in inter-strut spacings, to investigate their relationship to flow patterns. Human blood with fluorescently labeled platelets was circulated through an in vitro system that produced physiologic pulsatile flow in (1) a parallel plate blow chamber that contained two-dimensional (2D) stents that feature completely recirculating flow, partially recirculating flow, and completely reattached flow, and (2) a three-dimensional (3D) cylindrical tube that contained stents of various geometric designs. ^ Flow detachment and reattachment points exhibited very low platelet deposition. Platelet deposition was very low in the recirculation regions in the 3D stents unlike the 2D stents. Deposition distal to a strut was always high in 2D and 3D stents. Spirally recirculating regions were found in 3D unlike in 2D stents, where the deposition was higher than at well-separated regions of recirculation. ^
Resumo:
Mémoire numérisé par la Direction des bibliothèques de l'Université de Montréal.
Resumo:
We are interested in the emergence of new markets. While the literature contains various perspectives on how such new markets come to be, the dynamics of the marketization process are less clear. This paper focuses on the development of stent technology and examines the activities characteristic of its emerging market. We identify four market ‘moments’: a mutable marketing moment prior to the point of disruption; two parallel moments at the point of disruption – internecine marketing between emergent competitors, and subversive marketing between those competitors and established actors; and finally, a civilized marketing moment. We conclude that emergent competitors operate two distinct strategies at the point of disruption. Also, legal activities are central to marketization dynamics during this period. In terms of process, while creative destruction may broadly describe the move from disruption to acceptance, there is a period of creative construction prior to disruption, when the new market is coming into being.
Resumo:
Mémoire numérisé par la Direction des bibliothèques de l'Université de Montréal.
Resumo:
Les maladies cardiovasculaires sont la première cause de mortalité dans le monde et les anévrismes de l’aorte abdominale (AAAs) font partie de ce lot déplorable. Un anévrisme est la dilatation d’une artère pouvant conduire à la mort. Une rupture d’AAA s’avère fatale près de 80% du temps. Un moyen de traiter les AAAs est l’insertion d’une endoprothèse (SG) dans l’aorte, communément appelée la réparation endovasculaire (EVAR), afin de réduire la pression exercée par le flux sanguin sur la paroi. L’efficacité de ce traitement est compromise par la survenue d’endofuites (flux sanguins entre la prothèse et le sac anévrismal) pouvant conduire à la rupture de l’anévrisme. Ces flux sanguins peuvent survenir à n’importe quel moment après le traitement EVAR. Une surveillance par tomodensitométrie (CT-scan) annuelle est donc requise, augmentant ainsi le coût du suivi post-EVAR et exposant le patient à la radiation ionisante et aux complications des contrastes iodés. L’endotension est le concept de dilatation de l’anévrisme sans la présence d’une endofuite apparente au CT-scan. Après le traitement EVAR, le sang dans le sac anévrismal coagule pour former un thrombus frais, qui deviendra progressivement un thrombus plus fibreux et plus organisé, donnant lieu à un rétrécissement de l’anévrisme. Il y a très peu de données dans la littérature pour étudier ce processus temporel et la relation entre le thrombus frais et l’endotension. L’étalon d’or du suivi post-EVAR, le CT-scan, ne peut pas détecter la présence de thrombus frais. Il y a donc un besoin d’investir dans une technique sécuritaire et moins coûteuse pour le suivi d’AAAs après EVAR. Une méthode récente, l’élastographie dynamique, mesure l’élasticité des tissus en temps réel. Le principe de cette technique repose sur la génération d’ondes de cisaillement et l’étude de leur propagation afin de remonter aux propriétés mécaniques du milieu étudié. Cette thèse vise l’application de l’élastographie dynamique pour la détection des endofuites ainsi que de la caractérisation mécanique des tissus du sac anévrismal après le traitement EVAR. Ce projet dévoile le potentiel de l’élastographie afin de réduire les dangers de la radiation, de l’utilisation d’agent de contraste ainsi que des coûts du post-EVAR des AAAs. L’élastographie dynamique utilisant le « Shear Wave Imaging » (SWI) est prometteuse. Cette modalité pourrait complémenter l’échographie-Doppler (DUS) déjà utilisée pour le suivi d’examen post-EVAR. Le SWI a le potentiel de fournir des informations sur l’organisation fibreuse du thrombus ainsi que sur la détection d’endofuites. Tout d’abord, le premier objectif de cette thèse consistait à tester le SWI sur des AAAs dans des modèles canins pour la détection d’endofuites et la caractérisation du thrombus. Des SGs furent implantées dans un groupe de 18 chiens avec un anévrisme créé au moyen de la veine jugulaire. 4 anévrismes avaient une endofuite de type I, 13 avaient une endofuite de type II et un anévrisme n’avait pas d’endofuite. Des examens échographiques, DUS et SWI ont été réalisés à l’implantation, puis 1 semaine, 1 mois, 3 mois et 6 mois après le traitement EVAR. Une angiographie, un CT-scan et des coupes macroscopiques ont été produits au sacrifice. Les régions d’endofuites, de thrombus frais et de thrombus organisé furent identifiées et segmentées. Les valeurs de rigidité données par le SWI des différentes régions furent comparées. Celles-ci furent différentes de façon significative (P < 0.001). Également, le SWI a pu détecter la présence d’endofuites où le CT-scan (1) et le DUS (3) ont échoué. Dans la continuité de ces travaux, le deuxième objectif de ce projet fut de caractériser l’évolution du thrombus dans le temps, de même que l’évolution des endofuites après embolisation dans des modèles canins. Dix-huit anévrismes furent créés dans les artères iliaques de neuf modèles canins, suivis d’une endofuite de type I après EVAR. Deux gels embolisants (Chitosan (Chi) ou Chitosan-Sodium-Tetradecyl-Sulfate (Chi-STS)) furent injectés dans le sac anévrismal pour promouvoir la guérison. Des examens échographiques, DUS et SWI ont été effectués à l’implantation et après 1 semaine, 1 mois, 3 mois et 6 mois. Une angiographie, un CT-scan et un examen histologique ont été réalisés au sacrifice afin d’évaluer la présence, le type et la grosseur de l’endofuite. Les valeurs du module d’élasticité des régions d’intérêts ont été identifiées et segmentées sur les données pathologiques. Les régions d’endofuites et de thrombus frais furent différentes de façon significative comparativement aux autres régions (P < 0.001). Les valeurs d’élasticité du thrombus frais à 1 semaine et à 3 mois indiquent que le SWI peut évaluer la maturation du thrombus, de même que caractériser l’évolution et la dégradation des gels embolisants dans le temps. Le SWI a pu détecter des endofuites où le DUS a échoué (2) et, contrairement au CT-scan, détecter la présence de thrombus frais. Finalement, la dernière étape du projet doctoral consistait à appliquer le SWI dans une phase clinique, avec des patients humains ayant déjà un AAA, pour la détection d’endofuite et la caractérisation de l’élasticité des tissus. 25 patients furent sélectionnés pour participer à l’étude. Une comparaison d’imagerie a été produite entre le SWI, le CT-scan et le DUS. Les valeurs de rigidité données par le SWI des différentes régions (endofuite, thrombus) furent identifiées et segmentées. Celles-ci étaient distinctes de façon significative (P < 0.001). Le SWI a détecté 5 endofuites sur 6 (sensibilité de 83.3%) et a eu 6 faux positifs (spécificité de 76%). Le SWI a pu détecter la présence d’endofuites où le CT-scan (2) ainsi que le DUS (2) ont échoué. Il n’y avait pas de différence statistique notable entre la rigidité du thrombus pour un AAA avec endofuite et un AAA sans endofuite. Aucune corrélation n’a pu être établie de façon significative entre les diamètres des AAAs ainsi que leurs variations et l’élasticité du thrombus. Le SWI a le potentiel de détecter les endofuites et caractériser le thrombus selon leurs propriétés mécaniques. Cette technique pourrait être combinée au suivi des AAAs post-EVAR, complémentant ainsi l’imagerie DUS et réduisant le coût et l’exposition à la radiation ionisante et aux agents de contrastes néphrotoxiques.
Resumo:
Aim. Carotid artery stenting (CAS) is the treatment of choice for recurrent stenosis after carotid endarterectomy (CEA). However a significative incidence of in-stent restenosis could be occurred. Despite classical CEA leads to good results, in selective cases bypass graft may be the best treatment of in-stent restenosis. Case reports. We describe two cases of carotid bypass graft performed to treat a recurrent in-stent stenosis after CAS for post-CEA restenosis. No death and cardiac complication occurred and no cranial nerves impairment was detected. Conclusion. Prosthetic bypass graft is safe and effective in treatment of in-stent recurrent restenosis after CEA restenosis.
Resumo:
Coronary heart disease is a major cause of morbidity and mortality worldwide. Percutaneous coronary intervention (PCI) has become the most widely used method of coronary artery revascularisation. The use of stents to hold open atherosclerosis induced arterial narrowing has significantly reduced elastic recoil and acute vessel occlusion following balloon angioplasty. However, bare metal stents have been associated with in-stent restenosis attributed to vascular smooth muscle cell (VSMC) hyperplasia and excessive neointimal formation. The resultant luminal renarrowing may manifest clinically with the return of symptoms such as chest pain or shortness of breath. The development of drug eluting stents has significantly reduced the incidence of in-stent restenosis (ISR). Unfortunately the antiproliferative medications used not only inhibit VSMC proliferation but also re-endothelialisation of the stented vessel. In addition, the drug impregnated polymer coating has been associated with a chronic inflammatory response within the vessel wall predisposing patients to stent thrombosis. Thus the identification of novel therapies which promote vessel healing without excessive proliferative or inflammatory response may improve long term outcome and reduce the need for repeated revascularisation. MicroRNAs (miRs) are short (18-25 nucleotide) non-coding RNAs acting to regulate gene expression. By binding to the 3’untranslated region of mRNA they act to fine tune gene expression either by mRNA degradation or translational repression. Originally identified in coordinating tissue development microRNAs have also been shown to play important roles coordinating the inflammatory response and in numerous cardiovascular diseases. MiR-21 has been identified in human atherosclerotic plaques, arteriosclerosis obliterans and abdominal aortic aneurysms. In addition, its up regulation has been documented in preclinical models of vascular injury. This study sought to identify the role of miR-21 in the development of ISR. Utilising a small animal model of stenting and in vitro techniques, we sought to investigate its influence upon VSMC and immune cell response following stenting. 19 The refinement of a murine stenting model within the Baker laboratory and the electrochemical dissolution of the metal stent from within harvested vascular tissues significantly improved the ability to perform detailed histological analysis. In addition, identification of miRNAs using in situ hybridisation was achieved for the first time within stented tissue. Neointimal formation and ISR was significantly reduced in mice in which miR-21 had been genetically deleted. In addition, neointimal composition was found to be altered in miR-21 KO mice with reductions in VSMC and elastin content demonstrated. Importantly, no difference in re-endothelialisation was observed. In vitro analysis demonstrated that VSMCs from miR-21 KO mice had both reduced proliferative and migratory capacity following platelet derived growth factor stimulation. Molecular analysis revealed that these differences may, at least in part, be due to de-repression of programmed cell death 4 (PDCD4). PDCD4 is a known miR-21 target within VSMCs implicated in the suppression of proliferation and promotion of apoptosis. Unfortunately, initial attempts at antimiR mediated knockdown of miR-21 in vivo, failed to produce a similar change in the suppression of ISR. Furthermore, a significant alteration in macrophage polarisation state within the neointima of miR-21 WT and KO mice was noted. Immunohistochemical staining revealed a preponderance of anti-inflammatory M2 macrophages in KO mice. Analysis of bone marrow derived macrophages from miR-21 KO mice demonstrated an increased level of the peroxisome proliferation activating receptor-γ (PPARγ) which facilitates M2 polarisation. Importantly, significant alterations in numerous pro-inflammatory cytokines, which also have mitogenic effects, were also found following genetic deletion of miR-21. In Summary, this is the first study to look at miRs in the development of ISR. MiR-21 plays an important role in the development of ISR by influencing the proliferative response of VSMCs and modulating the immune response following stent deployment. Further attempts to modulate miR-21 expression following PCI may reduce ISR and the need for repeat revascularisation while also reducing the risk of stent thrombosis.
Resumo:
Les maladies cardiovasculaires sont la première cause de mortalité dans le monde et les anévrismes de l’aorte abdominale (AAAs) font partie de ce lot déplorable. Un anévrisme est la dilatation d’une artère pouvant conduire à la mort. Une rupture d’AAA s’avère fatale près de 80% du temps. Un moyen de traiter les AAAs est l’insertion d’une endoprothèse (SG) dans l’aorte, communément appelée la réparation endovasculaire (EVAR), afin de réduire la pression exercée par le flux sanguin sur la paroi. L’efficacité de ce traitement est compromise par la survenue d’endofuites (flux sanguins entre la prothèse et le sac anévrismal) pouvant conduire à la rupture de l’anévrisme. Ces flux sanguins peuvent survenir à n’importe quel moment après le traitement EVAR. Une surveillance par tomodensitométrie (CT-scan) annuelle est donc requise, augmentant ainsi le coût du suivi post-EVAR et exposant le patient à la radiation ionisante et aux complications des contrastes iodés. L’endotension est le concept de dilatation de l’anévrisme sans la présence d’une endofuite apparente au CT-scan. Après le traitement EVAR, le sang dans le sac anévrismal coagule pour former un thrombus frais, qui deviendra progressivement un thrombus plus fibreux et plus organisé, donnant lieu à un rétrécissement de l’anévrisme. Il y a très peu de données dans la littérature pour étudier ce processus temporel et la relation entre le thrombus frais et l’endotension. L’étalon d’or du suivi post-EVAR, le CT-scan, ne peut pas détecter la présence de thrombus frais. Il y a donc un besoin d’investir dans une technique sécuritaire et moins coûteuse pour le suivi d’AAAs après EVAR. Une méthode récente, l’élastographie dynamique, mesure l’élasticité des tissus en temps réel. Le principe de cette technique repose sur la génération d’ondes de cisaillement et l’étude de leur propagation afin de remonter aux propriétés mécaniques du milieu étudié. Cette thèse vise l’application de l’élastographie dynamique pour la détection des endofuites ainsi que de la caractérisation mécanique des tissus du sac anévrismal après le traitement EVAR. Ce projet dévoile le potentiel de l’élastographie afin de réduire les dangers de la radiation, de l’utilisation d’agent de contraste ainsi que des coûts du post-EVAR des AAAs. L’élastographie dynamique utilisant le « Shear Wave Imaging » (SWI) est prometteuse. Cette modalité pourrait complémenter l’échographie-Doppler (DUS) déjà utilisée pour le suivi d’examen post-EVAR. Le SWI a le potentiel de fournir des informations sur l’organisation fibreuse du thrombus ainsi que sur la détection d’endofuites. Tout d’abord, le premier objectif de cette thèse consistait à tester le SWI sur des AAAs dans des modèles canins pour la détection d’endofuites et la caractérisation du thrombus. Des SGs furent implantées dans un groupe de 18 chiens avec un anévrisme créé au moyen de la veine jugulaire. 4 anévrismes avaient une endofuite de type I, 13 avaient une endofuite de type II et un anévrisme n’avait pas d’endofuite. Des examens échographiques, DUS et SWI ont été réalisés à l’implantation, puis 1 semaine, 1 mois, 3 mois et 6 mois après le traitement EVAR. Une angiographie, un CT-scan et des coupes macroscopiques ont été produits au sacrifice. Les régions d’endofuites, de thrombus frais et de thrombus organisé furent identifiées et segmentées. Les valeurs de rigidité données par le SWI des différentes régions furent comparées. Celles-ci furent différentes de façon significative (P < 0.001). Également, le SWI a pu détecter la présence d’endofuites où le CT-scan (1) et le DUS (3) ont échoué. Dans la continuité de ces travaux, le deuxième objectif de ce projet fut de caractériser l’évolution du thrombus dans le temps, de même que l’évolution des endofuites après embolisation dans des modèles canins. Dix-huit anévrismes furent créés dans les artères iliaques de neuf modèles canins, suivis d’une endofuite de type I après EVAR. Deux gels embolisants (Chitosan (Chi) ou Chitosan-Sodium-Tetradecyl-Sulfate (Chi-STS)) furent injectés dans le sac anévrismal pour promouvoir la guérison. Des examens échographiques, DUS et SWI ont été effectués à l’implantation et après 1 semaine, 1 mois, 3 mois et 6 mois. Une angiographie, un CT-scan et un examen histologique ont été réalisés au sacrifice afin d’évaluer la présence, le type et la grosseur de l’endofuite. Les valeurs du module d’élasticité des régions d’intérêts ont été identifiées et segmentées sur les données pathologiques. Les régions d’endofuites et de thrombus frais furent différentes de façon significative comparativement aux autres régions (P < 0.001). Les valeurs d’élasticité du thrombus frais à 1 semaine et à 3 mois indiquent que le SWI peut évaluer la maturation du thrombus, de même que caractériser l’évolution et la dégradation des gels embolisants dans le temps. Le SWI a pu détecter des endofuites où le DUS a échoué (2) et, contrairement au CT-scan, détecter la présence de thrombus frais. Finalement, la dernière étape du projet doctoral consistait à appliquer le SWI dans une phase clinique, avec des patients humains ayant déjà un AAA, pour la détection d’endofuite et la caractérisation de l’élasticité des tissus. 25 patients furent sélectionnés pour participer à l’étude. Une comparaison d’imagerie a été produite entre le SWI, le CT-scan et le DUS. Les valeurs de rigidité données par le SWI des différentes régions (endofuite, thrombus) furent identifiées et segmentées. Celles-ci étaient distinctes de façon significative (P < 0.001). Le SWI a détecté 5 endofuites sur 6 (sensibilité de 83.3%) et a eu 6 faux positifs (spécificité de 76%). Le SWI a pu détecter la présence d’endofuites où le CT-scan (2) ainsi que le DUS (2) ont échoué. Il n’y avait pas de différence statistique notable entre la rigidité du thrombus pour un AAA avec endofuite et un AAA sans endofuite. Aucune corrélation n’a pu être établie de façon significative entre les diamètres des AAAs ainsi que leurs variations et l’élasticité du thrombus. Le SWI a le potentiel de détecter les endofuites et caractériser le thrombus selon leurs propriétés mécaniques. Cette technique pourrait être combinée au suivi des AAAs post-EVAR, complémentant ainsi l’imagerie DUS et réduisant le coût et l’exposition à la radiation ionisante et aux agents de contrastes néphrotoxiques.
Resumo:
Background: Autogenous vein grafting is widely used in regular bypassing procedures. Due to its mismatch with the host artery in both mechanical property and geometry, the graft often over expands under high arterial blood pressure and forms a step-depth where eddy flow develops, thus causing restenosis, fibrous graft wall, etc. External stents, such as sheaths being used to cuff the graft, have been introduced to eliminate these mismatches and increase the patency. Although histological and immunochemical studies have shown some positive effects of the external stent, the mechanical mismatch under the protection of an external stent remains poorly analyzed. Methods: In this study, the jugular veins taken from hypercholesterolemic rabbits were transplanted into the carotid arteries, and non-woven polyglycolic acid (PGA) fabric was used to fabricate the external stents to study the effect of the biodegradable external stent. Eight weeks after the operation, the grafts were harvested to perform mechanical tests and histological examinations. An arc tangent function was suggested to describe the relationship between pressure and cross-sectional area to analyse the compliance of the graft. Results: The results from the mechanical tests indicated that grafts either with or without external stents displayed large compliance in the low-pressure range and were almost inextensible in the high-pressure range. This was very different from the behavior of the arteries or veins in vivo. The data from histological tests showed that, with external stents, collagen fibers were more compact, whilst those in the graft without protection were looser and thicker. No elastic fiber was found in either kind of grafts. Furthermore, grafts without protection were over-expanded which resulted in much bigger cross-sectional areas. Conclusion: The PGA external extent contributes little to the reduction of the mechanical mismatch between the graft and its host artery while remodeling develops. For the geometric mismatch, it reduces the cross-section area, therefore matching with the host artery much better. Although there are some positive effects, conclusively the PGA is not an ideal material for external stent.
Resumo:
Arteries are heterogeneous, composite structures that undergo large cyclic deformations during blood transport. Presence, build-up and consequent rupture of blockages in blood vessels, called atherosclerotic plaques, lead to disruption in the blood flow that can eventually be fatal. Abnormal lipid profile and hypertension are the main risk factors for plaque progression. Treatments span from pharmacological methods, to minimally invasive balloon angioplasty and stent procedures, and finally to surgical alternatives. There is a need to understand arterial disease progression and devise methods to detect, control, treat and manage arterial disease through early intervention. Local delivery through drug eluting stents also provide an attractive option for maintaining vessel integrity and restoring blood flow while releasing controlled amount of drug to reduce and alleviate symptoms. Development of drug eluting stents is hence interesting albeit challenging because it requires an integration of knowledge of mechanical properties with material transport of drug through the arterial wall to produce a desired biochemical effect. Although experimental models are useful in studying such complex multivariate phenomena, numerical models of mass transport in the vessel have proved immensely useful to understand and delineate complex interactions between chemical species, physical parameters and biological variables. The goals of this review are to summarize literature based on studies of mass transport involving low density lipoproteins in the arterial wall. We also discuss numerical models of drug elution from stents in layered and porous arterial walls that provide a unique platform that can be exploited for the design of novel drug eluting stents.