488 resultados para ERGONOMICS


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aim:To examine how much final-year undergraduate dental students know about postural dental ergonomic requirements, and how well they apply these requirements clinically.Background:Dentists are vulnerable to diverse mechanical (e.g. postural) and non-mechanical occupational risks.Materials and Methods:Eight postural requirements found in normalising documents were identified, reproduced, photographed, and analysed to develop a test of visual perception (TVP). Photographs of the 69 participating students were taken during their clinical care to ascertain ergonomics compliance, after which the students were administered the TVP. Pearson's test was used to correlate the level of knowledge (TVP) and its clinical application (photographic analysis) among the 552 observations made for each test (total of 1104 observations).Results:65.7% of the TVP questions were answered correctly and 35% of the photographic cases were in compliance with ergonomic requirements (+ 0.67, P < 0.0001).Conclusion:The knowledge of ergonomics postural requirements and their clinical application among the dental students surveyed were not satisfactory. The reasons for the learning difficulties encountered by the students should be identified to improve the learning process. The didactic use of digital images in this study may help in this endeavour.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study evaluated anteroposterior trunk movements and the time spent on activities of load-carrying to surfaces at different heights, among experienced and inexperienced individuals. Thirty-six healthy males (16 experienced and 20 inexperienced in load-carrying) had their trunk movements recorded by an electrogoniometer while transporting boxes (7 and 15 kg) to surfaces of variable heights (low, low intermediate, high intermediate and high). Longer time was spent on trunk flexion when carrying loads to low surfaces and on trunk extension when carrying to high surfaces (p<0.05). Differences in time spent on trunk flexion/extension were identified between loads, and between groups for the heavier load. There were no differences in flexion/extension amplitudes between groups or loads. Although unnecessary flexion/extension occurring prior to a task may increase the exposure of the trunk to risky movements, the amplitudes reported here were relatively small and seemed to have occurred to facilitate the final tasks.Relevance to industryLifting devices and technological assistance are increasingly available in industrial settings. However, distribution centers and delivery services represent new demands on workers and involve an expressive amount of manual handling and carrying activities. Thus, studies on carrying strategies are necessary as they can provide guidelines for safer activities. (C) 2007 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study aimed to describe how to evaluate and quantify the ergonomic satisfaction level of dental clinics rooms. Requirements for design, production and selection of dental equipment as described in ISO/TC-106/SC-6-N-411, support more comprehensive studies for an ergonomic evaluation and ergo design of the dental workstations. It was created a checklist of ergonomics requirements which is supported by Standards ISO/FDI and acquired by mean of a literature review. According to information exposed at the document of the Ergonomics Society of Dental Ergonomics - ESDE we can consider that the elaboration of an ergonomic evaluation protocol regard to the dental workstation is an important demand for the ergonomics, particularly in relation to the performance of the ergonomic design which presents qualified to assist to dental equipment manufactures. By this means, the identification of the evaluation factors pointed in ISO/TC 106/SC 6 N 411 offers the basic information to the process of elaboration of this protocol addressed by the described general guidelines.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper describes a technique for extending the force range of thin conductive polymer force sensors used for measuring contact force. These sensors are conventionally used for measuring force by changing electrical resistance when they are compressed. The new method involves measuring change in electrical resistance when the flexible sensor, which is sensitive to both compression and bending, is sandwiched between two layers of spring steel, and the structure is supported on a thin metal ring. When external force is applied, the stiffened sensor inside the spring steel is deformed within the annular center of the ring, causing the sensor to bend in proportion to the applied force. This method effectively increases the usable force range, while adding little in the way of thickness and weight. Average error for loads between 10 N and 100 N was 2.2 N (SD = 1.7) for a conventional conductive polymer sensor, and 0.9 N (SD = 0.4) using the new approach. Although this method permits measurement of greater loads with an error less than 1 N, it is limited since the modified sensor is insensitive to loads less than 5 N. These modified sensors are nevertheless useful for directly measuring normal force applied against handles and tools and other situations involving forceful manual work activities, such as grasp, push, pull, or press that could not otherwise be measured in actual work situations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Packaging and labeling play a crucial role awhile protecting medicaments and transmitting a range of crucial information to the users. Taking into account the scarcity of specific studies in this area, it was considered great the need for a comprehensive survey about customers' satisfaction when handling these containers.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This article is about thermal comfort in the wearable product. The research correlates fashion and architecture, in so far as it elects the brise soleil - an architectural element capable of regulating temperature and ventilation inside buildings - as a study referential, in trying to transpose and adapt its mechanisms to the wearable apparel.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This research describes the application of a scientific and technological model of Ergonomics in the design of pre-school furniture. The constant presence of the desk in early education and its influence in the relationship between the user and his educational environment determined the necessity of this project. The pre-school desk was considered as a work station, where the joint aspects of education and child anthropometry substantiate the problem. The review of the Historical application of Ergonomics in the Design of children's products consolidated the importance of this report. The development of ergonomic research, characterised by investigations of the Brazilian child's Anthropometry Data and Biomechanical Features, resulted in dimensional parameters of the user and physical characteristics of the present furniture. These elements, together with a comprehension of activities and needs in the pre-school, were connected with aspects of bibliographical revision to result in a series of recomendations for design. Through the methods of Ergonomic Design, a new proposal for the pre-school desk was developed, denominated Mobipresc 3.6.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work presents the development and integration of an user interface (UI) framework based on various current input devices that take advantage of our ergonomics. The purpose is to teleoperate a holonomic robot using upper member gestures and postures for studying the suitable of such interfaces when programming and interacting with a mobile robot. As performance vary from UI to UI the framework is focused to be used as a complementary industrial or didactic tool thus, changing how inexperience users tackle their first impressions when working with mobile robots while performing simple gesture-based teleoperation tasks. © 2012 ICROS.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Brazilian and foreign companies operating in Brazil in the last 30 years have been using automated productive resources, especially robots. These 3 decades doesńt seem to have been enough to develop in the actors involved with robots an adequate professional awareness. If we consider the predictive security and ergonomic aspects involved, we notice that there are critical failures on handling these situations. So in this study we tried to observe the presence of the human being in some workstations that operate with robots in the Brazilian Southeastern region. © (2013) Trans Tech Publications, Switzerland.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Reusable cardboard boxes can be ergonomically designed for internal transportation of dry products in industrial settings. In this study we compared the effects of handling a regular commercial box and two cardboard prototypes on upper limb postures through the evaluation of movements, myoelectrical activity, perceived grip acceptability and capacity for reuse. The ergonomic designs provided a more acceptable grip, safer wrist and elbow movements and lower wrist extensors and biceps activity. Biomechanical disadvantages were observed only for one of the prototypes when handling to high surface. The prototypes were durable and suitable for extensive reuse (more than 2000 handlings) in internal industrial transportation. Despite being slightly more expensive than regular cardboard, the prototypes showed good cost-benefit considering their high durability. Relevance to industry: Cardboard boxes can be efficiently redesigned for allowing safer upper limb movements and lower muscle workload in manual materials handling. New designs can also be extensively reused for internal industrial transportation with good cost-benefit. © 2012 Elsevier B.V.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This research aims to investigate a topic sometimes overlooked among the research of ergonomics. Particularly, we treat the garments as personal protective equipment. In this study we abode on clothing produced and used in Brazil, making notes about the management of occupational safety for the use of such equipment. In turn, identify Relevant requirements for the design of personal protective equipment used in Brazil, in line with what is being studied in global forums on the subject. © 2013 Taylor & Francis Group.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Pesquisa e Desenvolvimento (Biotecnologia Médica) - FMB

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)