988 resultados para Design studies


Relevância:

40.00% 40.00%

Publicador:

Resumo:

DUE TO COPYRIGHT RESTRICTIONS ONLY AVAILABLE FOR CONSULTATION AT ASTON UNIVERSITY LIBRARY AND INFORMATION SERVICES WITH PRIOR ARRANGEMENT

Relevância:

40.00% 40.00%

Publicador:

Resumo:

DUE TO COPYRIGHT RESTRICTIONS ONLY AVAILABLE FOR CONSULTATION AT ASTON UNIVERSITY LIBRARY AND INFORMATION SERVICES WITH PRIOR ARRANGEMENT

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The poor retention and efficacy of instilled drops as a means of delivering drugs to the ophthalmic environment is well-recognised. The potential value of contact lenses as a means of ophthalmic drug delivery, and consequent improvement of pre-corneal retention is one obvious route to the development of a more effective ocular delivery system. Furthermore, the increasing availability and clinical use of daily disposable contact lenses provides the platform for the development of viable single-day use drug delivery devices based on existing materials and lenses. In order to provide a basis for the effective design of such devices, a systematic understanding of the factors affecting the interaction of individual drugs with the lens matrix is required. Because a large number of potential structural variables are involved, it is necessary to achieve some rationalisation of the parameters and physicochemical properties (such as molecular weight, charge, partition coefficients) that influence drug interactions. Ophthalmic dyes and structurally related compounds based on the same core structure were used to investigate these various factors and the way in which they can be used in concert to design effective release systems for structurally different drugs. Initial studies of passive diffusional release form a necessary precursor to the investigation of the features of the ocular environment that over-ride this simple behaviour. Commercially available contact lenses of differing structural classifications were used to study factors affecting the uptake of the surrogate actives and their release under 'passive' conditions. The interaction between active and lens material shows considerable and complex structure dependence, which is not simply related to equilibrium water content. The structure of the polymer matrix itself was found to have the dominant controlling influence on active uptake; hydrophobic interaction with the ophthalmic dye playing a major role. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This study identifies and investigates the potential use of in-eye trigger mechanisms to supplement the widely available information on release of ophthalmic drugs from contact lenses under passive release conditions. Ophthalmic dyes and surrogates have been successfully employed to investigate how these factors can be drawn together to make a successful system. The storage of a drug-containing lens in a pH lower than that of the ocular environment can be used to establish an equilibrium that favours retention of the drug in the lens prior to ocular insertion. Although release under passive conditions does not result in complete dye elution, the use of mechanical agitation techniques which mimic the eyelid blink action in conjunction with ocular tear chemistry promotes further release. In this way differentiation between passive and triggered in vitro release characteristics can be established. Investigation of the role of individual tear proteins revealed significant differences in their ability to alter the equilibrium between matrix-held and eluate-held dye or drug. These individual experiments were then investigated in vivo using ophthalmic dyes. Complete elution was found to be achievable in-eye; this demonstrated the importance of that fraction of the drug retained under passive conditions and the triggering effect of in-eye conditions on the release process. Understanding both the structure-property relationship between drug and material and in-eye trigger mechanisms, using ophthalmic dyes as a surrogate, provides the basis of knowledge necessary to design ocular drug delivery vehicles for in-eye release in a controllable manner.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

FIU's campus master plan should portray an overall concept of the University's vision. Its design should represent a distinctive sense of institutional purpose. Its architecture should support the campus design in the realization of an ideal academic environment. The present master plan of Florida International University (FIU) offers neither a clear typology of architectural elements nor adequate relationships and connections between buildings. FIU needs to enhance its master plan with an architectural and urban vocabulary that creates a better environment. This thesis will examine FIU's present master plan, explaining the history of its development. Further, it will critically examine the quality of the campus, highlighting the success and failure of its various parts. The unrealized potential of the campus' original vision will be juxtaposed to the built reality. In addition, FlU's planning strategies will be parallel with the planning of several master plans of American universities. Finally, this thesis will propose a set of criteria for the inclusion of a new building in the campus master plan. The Center of International Study will be the catalyst that would bring into focus the university's vision. As a means to prove the validity of these criteria, a new location for the center of international studies will be selected, and a schematic architectural proposal will be made.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This thesis presents details of the design and development of novel tools and instruments for scanning tunneling microscopy (STM), and may be considered as a repository for several years' worth of development work. The author presents design goals and implementations for two microscopes. First, a novel Pan-type STM was built that could be operated in an ambient environment as a liquid-phase STM. Unique features of this microscope include a unibody frame, for increased microscope rigidity, a novel slider component with large Z-range, a unique wiring scheme and damping mechanism, and a removable liquid cell. The microscope exhibits a high level of mechanical isolation at the tunnel junction, and operates excellently as an ambient tool. Experiments in liquid are on-going. Simultaneously, the author worked on designs for a novel low temperature, ultra-high vacuum (LT-UHV) instrument, and these are presented as well. A novel stick-slip vertical coarse approach motor was designed and built. To gauge the performance of the motor, an in situ motion sensing apparatus was implemented, which could measure the step size of the motor to high precision. A new driving circuit for stick-slip inertial motors is also presented, that o ffers improved performance over our previous driving circuit, at a fraction of the cost. The circuit was shown to increase step size performance by 25%. Finally, a horizontal sample stage was implemented in this microscope. The build of this UHV instrument is currently being fi nalized. In conjunction with the above design projects, the author was involved in a collaborative project characterizing N-heterocyclic carbene (NHC) self-assembled monolayers (SAMs) on Au(111) films. STM was used to characterize Au substrate quality, for both commercial substrates and those manufactured via a unique atomic layer deposition (ALD) process by collaborators. Ambient and UHV STM was then also used to characterize the NHC/Au(111) films themselves, and several key properties of these films are discussed. During this study, the author discovered an unexpected surface contaminant, and details of this are also presented. Finally, two models are presented for the nature of the NHC-Au(111) surface interaction based on the observed film properties, and some preliminary theoretical work by collaborators is presented.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This paper aims to crystallize recent research performed at the University of Worcester to investigate the feasibility of using the commercial game engine ‘Unreal Tournament 2004’ (UT2004) to produce ‘Educational Immersive Environments’ (EIEs) suitable for education and training. Our research has been supported by the UK Higher Education Academy. We discuss both practical and theoretical aspects of EIEs. The practical aspects include the production of EIEs to support high school physics education, the education of architects, and the learning of literacy by primary school children. This research is based on the development of our novel instructional medium, ‘UnrealPowerPoint’. Our fundamental guiding principles are that, first, pedagogy must inform technology, and second, that both teachers and pupils should be empowered to produce educational materials. Our work is informed by current educational theories such as constructivism, experiential learning and socio-cultural approaches as well as elements of instructional design and game principles.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Background and Purpose: At least part of the failure in the transition from experimental to clinical studies in stroke has been attributed to the imprecision introduced by problems in the design of experimental stroke studies. Using a metaepidemiologic approach, we addressed the effect of randomization, blinding, and use of comorbid animals on the estimate of how effectively therapeutic interventions reduce infarct size. Methods: Electronic and manual searches were performed to identify meta-analyses that described interventions in experimental stroke. For each meta-analysis thus identified, a reanalysis was conducted to estimate the impact of various quality items on the estimate of efficacy, and these estimates were combined in a meta meta-analysis to obtain a summary measure of the impact of the various design characteristics. Results: Thirteen meta-analyses that described outcomes in 15 635 animals were included. Studies that included unblinded induction of ischemia reported effect sizes 13.1% (95% CI, 26.4% to 0.2%) greater than studies that included blinding, and studies that included healthy animals instead of animals with comorbidities overstated the effect size by 11.5% (95% CI, 21.2% to 1.8%). No significant effect was found for randomization, blinded outcome assessment, or high aggregate CAMARADES quality score. Conclusions: We provide empirical evidence of bias in the design of studies, with studies that included unblinded induction of ischemia or healthy animals overestimating the effectiveness of the intervention. This bias could account for the failure in the transition from bench to bedside of stroke therapies.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Local anesthetic agents cause temporary blockade of nerve impulses productiong insensitivity to painful stimuli in the area supplied by that nerve. Bupivacaine (BVC) is an amide-type local anesthetic widely used in surgery and obstetrics for sustained peripheral and central nerve blockade. in this study, we prepared and characterized nanosphere formulations containing BVC. To achieve these goals, BVC loaded poly(DL-lactide-co-glycolide) (PLGA) nanospheres (NS) were prepared by nanopreciptation and characterized with regard to size distribution, drug loading and cytotoxicity assays. The 2(3-1) factorial experimental design was used to study the influence of three different independent variables on nanoparticle drug loading. BVC was assayed by HPLC, the particle size and zeta potential were determined by dynamic light scattering. BVC was determined using a combined ultrafiltration-centrifugation technique. The results of optimized formulations showed a narrow size distribution with a polydispersivity of 0.05%, an average diameter of 236.7 +/- 2.6 nm and the zeta potential -2.93 +/- 1,10 mV. In toxicity studies with fibroblast 3T3 cells, BVC loaded-PLGA-NS increased cell viability, in comparison with the effect produced by free BVC. In this way, BVC-loaded PLGA-NS decreased BVC toxicity. The development of BVC formulations in carriers such as nanospheres could offer the possibility of controlling drug delivery in biological systems, prolonging the anesthetic effect and reducing toxicity.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Objectifs: Examiner les tendances temporelles, les déterminants en lien avec le design des études et la qualité des taux de réponse rapportés dans des études cas-témoins sur le cancer publiées lors des 30 dernières années. Méthodes: Une revue des études cas-témoins sur le cancer a été menée. Les critères d'inclusion étaient la publication (i) dans l’un de 15 grands périodiques ciblés et (ii) lors de quatre périodes de publication (1984-1986, 1995, 2005 et 2013) couvrant trois décennies. 370 études ont été sélectionnées et examinées. La méthodologie en lien avec le recrutement des sujets et la collecte de données, les caractéristiques de la population, les taux de participation et les raisons de la non-participation ont été extraites de ces études. Des statistiques descriptives ont été utilisées pour résumer la qualité des taux de réponse rapportés (en fonction de la quantité d’information disponible), les tendances temporelles et les déterminants des taux de réponse; des modèles de régression linéaire ont été utilisés pour analyser les tendances temporelles et les déterminants des taux de participation. Résultats: Dans l'ensemble, les qualités des taux de réponse rapportés et des raisons de non-participation étaient très faible, particulièrement chez les témoins. La participation a diminué au cours des 30 dernières années, et cette baisse est plus marquée dans les études menées après 2000. Lorsque l'on compare les taux de réponse dans les études récentes a ceux des études menées au cours de 1971 à 1980, il y a une plus grande baisse chez les témoins sélectionnés en population générale ( -17,04%, IC 95%: -23,17%, -10,91%) que chez les cas (-5,99%, IC 95%: -11,50%, -0,48%). Les déterminants statistiquement significatifs du taux de réponse chez les cas étaient: le type de cancer examiné, la localisation géographique de la population de l'étude, et le mode de collecte des données. Le seul déterminant statistiquement significatif du taux de réponse chez les témoins hospitaliers était leur localisation géographique. Le seul déterminant statistiquement significatif du taux de participation chez les témoins sélectionnés en population générale était le type de répondant (sujet uniquement ou accompagné d’une tierce personne). Conclusion: Le taux de participation dans les études cas-témoins sur le cancer semble avoir diminué au cours des 30 dernières années et cette baisse serait plus marquée dans les études récentes. Afin d'évaluer le niveau réel de non-participation et ses déterminants, ainsi que l'impact de la non-participation sur la validité des études, il est nécessaire que les études publiées utilisent une approche normalisée pour calculer leurs taux de participation et qu’elles rapportent ceux-ci de façon transparente.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Objectifs: Examiner les tendances temporelles, les déterminants en lien avec le design des études et la qualité des taux de réponse rapportés dans des études cas-témoins sur le cancer publiées lors des 30 dernières années. Méthodes: Une revue des études cas-témoins sur le cancer a été menée. Les critères d'inclusion étaient la publication (i) dans l’un de 15 grands périodiques ciblés et (ii) lors de quatre périodes de publication (1984-1986, 1995, 2005 et 2013) couvrant trois décennies. 370 études ont été sélectionnées et examinées. La méthodologie en lien avec le recrutement des sujets et la collecte de données, les caractéristiques de la population, les taux de participation et les raisons de la non-participation ont été extraites de ces études. Des statistiques descriptives ont été utilisées pour résumer la qualité des taux de réponse rapportés (en fonction de la quantité d’information disponible), les tendances temporelles et les déterminants des taux de réponse; des modèles de régression linéaire ont été utilisés pour analyser les tendances temporelles et les déterminants des taux de participation. Résultats: Dans l'ensemble, les qualités des taux de réponse rapportés et des raisons de non-participation étaient très faible, particulièrement chez les témoins. La participation a diminué au cours des 30 dernières années, et cette baisse est plus marquée dans les études menées après 2000. Lorsque l'on compare les taux de réponse dans les études récentes a ceux des études menées au cours de 1971 à 1980, il y a une plus grande baisse chez les témoins sélectionnés en population générale ( -17,04%, IC 95%: -23,17%, -10,91%) que chez les cas (-5,99%, IC 95%: -11,50%, -0,48%). Les déterminants statistiquement significatifs du taux de réponse chez les cas étaient: le type de cancer examiné, la localisation géographique de la population de l'étude, et le mode de collecte des données. Le seul déterminant statistiquement significatif du taux de réponse chez les témoins hospitaliers était leur localisation géographique. Le seul déterminant statistiquement significatif du taux de participation chez les témoins sélectionnés en population générale était le type de répondant (sujet uniquement ou accompagné d’une tierce personne). Conclusion: Le taux de participation dans les études cas-témoins sur le cancer semble avoir diminué au cours des 30 dernières années et cette baisse serait plus marquée dans les études récentes. Afin d'évaluer le niveau réel de non-participation et ses déterminants, ainsi que l'impact de la non-participation sur la validité des études, il est nécessaire que les études publiées utilisent une approche normalisée pour calculer leurs taux de participation et qu’elles rapportent ceux-ci de façon transparente.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Networked control over data networks has received increasing attention in recent years. Among many problems in networked control systems (NCSs) is the need to reduce control latency and jitter and to deal with packet dropouts. This paper introduces our recent progress on a queuing communication architecture for real-time NCS applications, and simple strategies for dealing with packet dropouts. Case studies for a middle-scale process or multiple small-scale processes are presented for TCP/IP based real-time NCSs. Variations of network architecture design are modelled, simulated, and analysed for evaluation of control latency and jitter performance. It is shown that a simple bandwidth upgrade or adding hierarchy does not necessarily bring benefits for performance improvement of control latency and jitter. A co-design of network and control is necessary to maximise the real-time control performance of NCSs

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Lead is present everywhere in the environment and has been defined as one of the greatest threats to the human health. In this paper, attempts have been made to study a way of recycling the lead produced from waste usage and disposed of in such a way as to avoid degrading the surrounding environment. In order to contain the waste, recycled asphalt material is mixed with the lead and then heated with microwave energy. This is an attempt to solidify and reduce the lead contaminants and use the final product as sub-base material in road pavement construction. The microwave heating of the specimens is carried out with 30%, 50%, 80% and 100% of power at 800W. The optimum power mode is used to compare with the conventional heating of asphalt with sulfur additive. The results are characterized by compact density, permeability, and subjected to toxicity test with regards to lead concentration. A mechanical test to evaluate the stability is also performed on the three methods of solidification and to prove that microwave zapping method allow to convert into an environmentally stable material for recycling without having to be deposited in a landfill site.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Research on the impact of Information Systems (IS) reported in both academic literature and popular press has reported confounding results. Some studies have reported encouraging results of IS, while others have reported nil or detrimental results. The contradictory results of these research studies can be partially attributed to the weaknesses in survey instruments. In an attempt to increase the validity of conclusions of IS assessment studies, survey instrument design should follow a rigorous and scientific procedure. This paper illustrates key validity and reliability issues in measuring Information Systems performance, using examples from a study designed to assess Enterprise Resource Planning systems success. The article emphasizes on the importance of the survey method and the theoretical considerations of item derivation, scale development and item evaluation. Examples are provided from the ERP assessment study to supplement the readers understanding of the theoretical concepts of survey design.