694 resultados para Craniocervical Flexion
Resumo:
We evaluated midterm patient-reported outcomes and satisfaction with total hip arthroplasty in patients who had severe juvenile idiopathic arthritis. Thirty-one patients (49 hips), with a mean age of 29 years (range, 16-43 years), reported low hip pain and stiffness at follow-up (mean, 7 years; range, 3-17 years). Up to 92% were satisfied with their ability to perform various activities; 96% were satisfied with pain relief. A mean postoperative flexion arc of 96° was observed. Final 36-Item Short Form Health Survey, EuroQol in 5 dimensions, Western Ontario and McMaster Universities Arthritis Index, and Harris Hip scores were lower than reference populations, particularly for mobility, physical functioning, and social functioning subscores. Young adults with end-stage hip involvement and severe longstanding juvenile idiopathic arthritis expressed high satisfaction with total hip arthroplasty, which improved range of motion, pain, and stiffness, despite poor performance on widely used outcome measures.
Resumo:
INTRODUCTION: The importance of the micromovements in the mechanism of aseptic loosening is clinically difficult to evaluate. To complete the analysis of a series of total knee arthroplasties (TKA), we used a tridimensional numerical model to study the micromovements of the tibial implant. MATERIAL AND METHODS: Fifty one patients (with 57 cemented Porous Coated Anatomic TKAs) were reviewed (mean follow-up 4.5 year). Radiolucency at the tibial bone-cement interface was sought on the AP radiographs and divided in 7 areas. The distribution of the radiolucency was then correlated with the axis of the lower limb as measured on the orthoradiograms. The tridimensional numerical model is based on the finite element method. It allowed the measurement of the cemented prosthetic tibial implant's displacements and the micromovements generated at bone-ciment interface. A total load (2000 Newton) was applied at first vertically and asymetrically on the tibial plateau, thereby simulating an axial deviation of the lower limbs. The vector's posterior inclination then permitted the addition of a tangential component to the axial load. This type of effort is generated by complex biomechanical phenomena such as knee flexion. RESULTS: 81 per cent of the 57 knees had a radiolucent line of at least 1 mm, at one or more of the tibial cement-epiphysis jonctional areas. The distribution of these lucent lines showed that they came out more frequently at the periphery of the implant. The lucent lines appeared most often under the unloaded margin of the tibial plateau, when axial deviation of lower limbs was present. Numerical simulations showed that asymetrical loading on the tibial plateau induced a subsidence of the loaded margin (0-100 microns) and lifting off at the opposite border (0-70 microns). The postero-anterior tangential component induced an anterior displacement of the tibial implant (160-220 microns), and horizontal micromovements with non homogenous distribution at the bone-ciment interface (28-54 microns). DISCUSSION: Comparison of clinical and numerical results showed a relation between the development of radiolucent lines and the unloading of the tibial implant's margin. The deleterious effect of lower limbs' axial deviation is thereby proven. The irregular distribution of lucent lines under the tibial plateau was similar of the micromovements' repartition at the bone-cement interface when tangential forces were present. A causative relation between the two phenomenaes could not however be established. Numerical simulation is a truly useful method of study; it permits to calculate micromovements which are relative, non homogenous and of very low amplitude. However, comparative clinical studies remain as essential to ensure the credibility of results.
Resumo:
Children with unresolved brachial plexus palsy frequently develop a disabling internal rotation contracture of the shoulder. Several surgical options, including soft tissue procedures such as muscle releases and/or transfers, and bone operations such as humeral osteotomy are available to correct this deformity. This study describes the effect of subscapularis muscle release performed in isolation. Thirteen patients (5 boys, 8 girls) were reviewed at an average of 3.5 years after their surgery (range, 2-7 years). Their mean age at operation was 4.7 years (range, 1-8 years). Three children had C5-C6 palsies, 8 had C5-C7 palsies, and 2 had C5-C8 palsies. Postoperatively, patients presented significant gains in shoulder active lateral rotation (+49 degrees, from 5 to 54 degrees), active abduction (+30 degrees, from 63 to 93 degrees), active flexion (+46 degrees, from 98 to 144 degrees), and active extension (+23 degrees, from 7 to 30 degrees). Gains were also observed in passive range of motion, but of a lesser degree. Subscapularis muscle release is a procedure we found to have few significant complications and was highly effective in increasing active range of motion and restoring shoulder function.
Resumo:
Objectif Évaluer les sollicitations cardiorespiratoires d'une évaluation isocinétique des muscles extenseurs/fléchisseurs du tronc. Méthode Huit sujets masculins (24,9±1,4ans) ont réalisé des exercices d'extension-flexion du rachis en mode isocinétique. Ce test comportait trois répétitions à 30°/s, trois répétitions à 60°/s et 15 répétitions à 120°/s en mode concentrique. Deux minutes de récupération étaient respectées entre chaque série. Des mesures de fréquence cardiaque, pression artérielle, consommation d'oxygène, et lactates sanguins étaient réalisées au repos et en fin d'exercice. Résultats Une augmentation significative de 84 % de la FC max, correspondant à 80 % de la FC maximale théorique a été mesurée. L'élévation de la TA systolique à l'effort correspondait à une augmentation de 20 % par rapport au repos. Une augmentation de 47 % de la VO2max a été mesurée. Le pic de lactates observé lors de la série de 15 répétitions montrait une augmentation significative de 230 % par rapport à la valeur de repos. La recherche de facteurs de risque cardiovasculaires doit être faite avant tout test isocinétique. Une épreuve d'effort conventionnelle peut être proposée aux patients à risque si une série correspondant à un test de résistance à la fatigue est envisagée.
Resumo:
To study the effects of muscle paralysis on joint mobility, we compared eight premature infants treated with pancuronium bromide with a control group. A significant reduction was observed in hip and knee flexion, and in ankle dorsal extension, which tended to resolve in time. We conclude that muscle paralysis reduces the mobility of selected joints; spontaneous activity appears to prevent long-term contractures.
Resumo:
Background/Purpose: Since the end of 2009, an ultrasound scoring call SONAR has been implemented for RA patients as a routine tool in the SCQM registry (Swiss Clinical Quality Management registry for rheumatic diseases). A cross-sectional evaluation of patients with active disease and clinical remission according to the DAS28ESR and the novel ACR/EULAR remission criteria from 2010 clearly indicated a good correlational external validity of synovial pathologies with clinical disease activity in RA (2012 EULAR meeting. Objective: of this study was to evaluate the sensitivity to change of B-mode and Power-Doppler scores in a longitudinal perspective along with the changes in DAS28ESR in two consecutive visits among the patients included in the SCQM registry Methods: All patients who had at least two SONAR scores and simultaneous DAS28ESR evaluations between December 2009 and June 2012 were included in this study. The data came from 20 different operators working mostly in hospitals but also in private practices, who had received a previous teaching over 3 days in a reference center. The SONAR score includes a semi-quantitative B mode and Power-Doppler evaluation of 22 joints from 0 to 3, maximum 66 points for each score. The selection of these 22 joints was done in analogy to a 28 joint count and further restricted to joint regions with published standard ultrasound images. Both elbows and wrist joints were dynamically scanned from the dorsal and the knee joints from a longitudinal suprapatellar view in flexion and in joint extension. The bilateral evaluation of the second to fifth metacarpophalangeal and proximal interphalangeal joints was done from a palmar view in full extension, and the Power-Doppler scoring from a dorsal view with hand and finger position in best relaxation. Results: From the 657 RA patients with at least one score performed, 128 RA patients with 2 or more consultations of DAS28ESR, and a complete SONAR data set could be included. The mean (SD) time between the two evaluations was 9.6 months (54). The mean (SD) DAS28ESR was: 3.5 (1.3) at the first visit and was significantly lower (mean 3.0, SD.2.0, p:_0.0001) at the second visit. The mean (SD) of the total B mode was 12 (9.5) at baseline and 9.6 (7.6) at follow-up (p_0.0004). The Power-Doppler score at entry was 2.9 (5.7) and 1.9 (3.6), at the second visit, p _0.0001. The Pearson r correlation between change in DAS28ESR and the B mode was 0.44 (95% CI: 0.29, 0.57, p_ 0.0001),and 0.35 (95% CI: 0.16, 0.50, p _ 0.0002) for the Power-Doppler score,. Clinical relevant change in DAS (_1.1) was associated with a change of total B mode score _3 in 23/32 patients and a change a Doppler score _0.5 in 19/26. Conclusion: This study confirms that the SONAR score is sensitive to change and provides a complementary method of assessing RA disease activity to the DAS that could be very useful in daily practice.
Resumo:
Background: The first AO comprehensive pediatric long bone fracture classification system has been established following a structured path of development and validation with experienced pediatric surgeons. Methods: A follow-up series of agreement studies was applied to specify and evaluate a grading system for displacement of pediatric supracondylar fractures. An iterative process comprising an international group of 5 experienced pediatric surgeons (Phase 1) followed by a pragmatic multicenter agreement study involving 26 raters (Phase 2) was used. The last evaluations were conducted on a consecutive collection of 154 supracondylar fractures documented by standard anteroposterior and lateral radiographs. Results: Fractures were classified according to 1 of 4 grades: I = incomplete fracture with no or minimal displacement; II = Incomplete fracture with continuity of the posterior (extension fracture) or anterior cortex (flexion fracture); III = lack of bone continuity (broken cortex), but still some contact between the fracture planes; IV = complete fracture with no bone continuity (broken cortex), and no contact between the fracture planes. A diagnostic algorithm to support the practical application of the grading system in a clinical setting, as well as an aid using a circle placed over the capitellum was proposed. The overall kappa coefficients were 0.68 and 0.61 in the Phase 1 and Phase 2 studies, respectively. In the Phase 1 study, fracture grades I, II, III, and IV were classified with median accuracies of 91%, 82%, 83%, and 99.5%, respectively. Similar median accuracies of 86% (Grade I), 73% (Grade II), 83%(Grade III), and 92% were reported for the Phase 2 study. Reliability was high in distinguishing complete, unstable fractures from stable injuries [ie, kappa coefficients of 0.84 (Phase 1) and 0.83 (Phase 2) were calculated]; in Phase 2, surgeons' accuracies in classifying complete fractures were all above 85%. Conclusions: With clear and unambiguous definition, this new grading system for supracondylar fracture displacement has proved to be sufficiently reliable and accurate when applied by pediatric surgeons in the framework of clinical routine as well as research.
Resumo:
The purpose of this paper is to discuss the post-traumatic overload syndrome of the os trigonum as a possible cause of posterior ankle impingement and hindfoot pain. We have reviewed 19 athletes who were referred to our foot unit between 1995 and 2001 because of posterior ankle pain, and in whom a post-traumatic overload syndrome of os trigonum was diagnosed. All these patients were followed up over a period of 2 years. In 11 cases a chronic repetitive movements in forced plantar flexion was found. In the other eight cases the pain appeared to persist after a standard treatment of an ankle sprain in inversion plantar flexion. The diagnosis was based on clinical history, physical examination and X-rays that revealed a non-fused os trigonum. The confirmation of diagnosis was carried-out injecting local anaesthetic under fluoroscopic control. In all cases a corticosteroid injection as first line treatment was performed. In 6 cases a second injection was necessary to alleviate pain because incomplete recovery with the first injection. Three cases (16%) were recalcitrant to this treatment and in these three cases a surgical excision of the os trigonum was carried out. Our conclusion is that after some chronic athletic activity or an acute ankle sprain the os trigonum, if present, may undergo mechanical overload, remain undisrupted and become painful. Treatment by corticosteroid injection often resolves the problem.
Resumo:
The aim of this study was to develop an ambulatory system for the three-dimensional (3D) knee kinematics evaluation, which can be used outside a laboratory during long-term monitoring. In order to show the efficacy of this ambulatory system, knee function was analysed using this system, after an anterior cruciate ligament (ACL) lesion, and after reconstructive surgery. The proposed system was composed of two 3D gyroscopes, fixed on the shank and on the thigh, and a portable data logger for signal recording. The measured parameters were the 3D mean range of motion (ROM) and the healthy knee was used as control. The precision of this system was first assessed using an ultrasound reference system. The repeatability was also estimated. A clinical study was then performed on five unilateral ACL-deficient men (range: 19-36 years) prior to, and a year after the surgery. The patients were evaluated with the IKDC score and the kinematics measurements were carried out on a 30 m walking trial. The precision in comparison with the reference system was 4.4 degrees , 2.7 degrees and 4.2 degrees for flexion-extension, internal-external rotation, and abduction-adduction, respectively. The repeatability of the results for the three directions was 0.8 degrees , 0.7 degrees and 1.8 degrees . The averaged ROM of the five patients' healthy knee were 70.1 degrees (standard deviation (SD) 5.8 degrees), 24.0 degrees (SD 3.0 degrees) and 12.0 degrees (SD 6.3 degrees for flexion-extension, internal-external rotation and abduction-adduction before surgery, and 76.5 degrees (SD 4.1 degrees), 21.7 degrees (SD 4.9 degrees) and 10.2 degrees (SD 4.6 degrees) 1 year following the reconstruction. The results for the pathologic knee were 64.5 degrees (SD 6.9 degrees), 20.6 degrees (SD 4.0 degrees) and 19.7 degrees (8.2 degrees) during the first evaluation, and 72.3 degrees (SD 2.4 degrees), 25.8 degrees (SD 6.4 degrees) and 12.4 degrees (SD 2.3 degrees) during the second one. The performance of the system enabled us to detect knee function modifications in the sagittal and transverse plane. Prior to the reconstruction, the ROM of the injured knee was lower in flexion-extension and internal-external rotation in comparison with the controlateral knee. One year after the surgery, four patients were classified normal (A) and one almost normal (B), according to the IKDC score, and changes in the kinematics of the five patients remained: lower flexion-extension ROM and higher internal-external rotation ROM in comparison with the controlateral knee. The 3D kinematics was changed after an ACL lesion and remained altered one year after the surgery
Resumo:
OBJECTIVE: The aim of the current study was to investigate the biomechanical stability and fixation strength provided by a posterior approach reconstruction technique to realign the craniovertebral junction.¦METHODS: We tested seven human cadaver occipito-cervical spines (occiput-C4) by applying pure moments of ±1.5 Nm on a spine tester. Each specimen was tested in the following modes: 1) intact; 2) injured; 3) spacers alone at C1-C2 articulation (S); 4) spacers plus C1-C2 Posterior Instrumentation (S+PI); and 5) spacers plus C1-C2 posterior instrumentation plus midline wiring (S+PI+MLW). C1-C2 range of motion for each construct was obtained in flexion-extension, lateral bending, and axial rotation.¦RESULTS: In all the loading modes, S, S+PI, and S+PI+MLW constructs significantly reduced range of motion compared with the intact and injured condition (P < 0.05). There was no statistical difference between any of the three instrumentation constructs (P > 0.05).¦CONCLUSIONS: This study investigated the biomechanics of the posterior approach technique for realignment of the craniovertebral junction and also made comparisons with additional posterior fixations. The stand-alone spacers were stable in all three loading modes. Posterior instrumentation increased the stability as compared to stand-alone spacers. The third point of fixation, carried out by using midline wiring, increased the stability further. However, there was not much difference in the stability imparted with the midline wiring versus without. The present study highlights the biomechanics of this novel concept and reaffirms the view that distraction of the C1-C2 articular facets and direct articular joint atlantoaxial fixation would be an ideal method of management of basilar invagination.
Resumo:
PURPOSE: The primary objective of this study was to describe the frequency of behaviors observed during rest, a non-nociceptive procedure, and a nociceptive procedure in brain-injured intensive care unit (ICU) patients with different levels of consciousness (LOC). Second, it examined the inter-rater reliability and discriminant and concurrent validity of the behavioral checklist used. METHODS: The non-nociceptive procedure involved calling the patient and shaking his/her shoulder. The nociceptive procedure involved turning the patient. The frequency of behaviors was recorded using a behavioral checklist. RESULTS: Patients with absence of movement, or stereotyped flexion or extension responses to a nociceptive stimulus displayed more behaviors during turning (median 5.5, range 0-14) than patients with localized responses (median 4, range 0-10) or able to self-report their pain (median 4, range 0-10). Face flushing, clenched teeth, clenched fist, and tremor were more frequent in patients with absence of movement, or stereotyped responses to a nociceptive stimulus. The reliability of the checklist was supported by a high intra-class correlation coefficient (0.77-0.92), and the internal consistency was acceptable in all three groups (KR 20, 0.71-0.85). Discriminant validity was supported as significantly more behaviors were observed during nociceptive stimulation than at rest. Concurrent validity was confirmed as checklist scores were correlated to the patients' self-reports of pain (r s = 0.53; 95 % CI 0.21-0.75). CONCLUSION: Brain-injured patients reacted significantly more during a nociceptive stimulus and the number of observed behaviors was higher in patients with a stereotyped response.
Resumo:
Controversy exists about the best method to achieve bone fusion in four-corner arthrodesis. Thirty-five patients who underwent this procedure by our technique were included in the study. Surgical indications were stage II-III SLAC wrist, stage II SNAC wrist and severe traumatic midcarpal joint injury. Mean follow-up was 4.6 years. Mean active flexion and extension were 34 degrees and 30 degrees respectively; grip strength recovery was 79%. Radiological consolidation was achieved in all cases. The mean DASH score was 23 and the postoperative pain improvement by visual analogue scale was statistically significant. Return to work was possible at 4 months for the average patient. Complications were a capitate fracture in one patient and the need for hardware removal in four cases. Four-corner bone wrist arthrodesis by dorsal rectangular plating achieves an acceptable preservation of range of motion with good pain relief, an excellent consolidation rate and minimal complications.
Resumo:
OBJECTIVES: This study investigated the relationship between inter-arm coordination and the energy cost of locomotion in front crawl and breaststroke and explored swimmers' flexibility in adapting their motor organization away from their preferred movement pattern. DESIGN: Nine front-crawlers performed three 300-m in front crawl and 8 breaststrokers performed three 200-m in breaststroke at constant submaximal intensity and with 5-min rests. Each trial was performed randomly in a different coordination pattern: freely chosen, 'maximal glide' and 'minimal glide'. Two underwater cameras videotaped frontal and side views to analyze speed, stroke rate, stroke length and inter-limb coordination. METHODS: In front crawl, inter-arm coordination was quantified by the index of coordination (IdC) and the leg beat kicks were counted. In breaststroke, four time gaps quantified the arm to leg coordination (i.e., time between leg and arm propulsions; time between beginning, 90° flexion and end of arm and leg recoveries). The energy cost of locomotion was calculated from gas exchanges and blood lactate concentration. RESULTS: In both front crawl and breaststroke, the freely chosen coordination corresponded to glide pattern and showed the lowest energy cost (12.8 and 17.1Jkg(-1)m(-1), respectively). Both front-crawlers and breaststrokers were able to reach 'maximal glide' condition (respectively, +35% and +28%) but not 'minimal glide' condition for front crawl. CONCLUSIONS: The freely chosen pattern appeared more economic because more trained. When coordination was constrained, the swimmers had higher coordination flexibility in breaststroke than in front crawl, suggesting that breaststroke coordination was easier to regulate by changing glide time.
Resumo:
BACKGROUND: Accurate assessment of glenoid inclination is of interest for a variety of conditions and procedures. The purpose of this study was to develop an accurate and reproducible measurement for glenoid inclination on standardized anterior-posterior (AP) radiographs and on computed tomography (CT) images. MATERIALS AND METHODS: Three consistently identifiable angles were defined: Angle α by line AB connecting the superior and inferior glenoid tubercle (glenoid fossa) and the line identifying the scapular spine; angle β by line AB and the floor of the supraspinatus fossa; angle γ by line AB and the lateral margin of the scapula. Experimental study: these 3 angles were measured in function of the scapular position to test their resistance to rotation. Conventional AP radiographs and CT scans were acquired in extension/flexion and internal/external rotation in a range up to ±40°. Clinical study: the inter-rater reliability of all angles was assessed on AP radiographs and CT scans of 60 patients (30 with proximal humeral fractures, 30 with osteoarthritis) by 2 independent observers. RESULTS: The experimental study showed that angle α and β have a resistance to rotation of up to ±20°. The deviation from neutral position was not more than ±10°. The results for the inter-rater reliability analyzed by Bland-Altman plots for the angle β fracture group were (mean ± standard deviation) -0.1 ± 4.2 for radiographs and -0.3 ± 3.3 for CT scans; and for the osteoarthritis group were -1.2 ± 3.8 for radiographs and -3.0 ± 3.6 for CT scans. CONCLUSION: Angle β is the most reproducible measurement for glenoid inclination on conventional AP radiographs, providing a resistance to positional variability of the scapula and a good inter-rater reliability.
Resumo:
La déchirure des ischio-jambiers est la blessure non-traumatique la plus fréquemment rencontrée dans les sports demandant une course à haute vitesse. Les ischio-jambiers sont particulièrement vulnérables lors de la fin de phase d'oscillation du sprint étant donné qu'ils se contractent excentriquement alors qu'ils sont en position d'allongement. Le renforcement excentrique a été montré comme étant une méthode efficace pour diminuer le risque de blessure. Cependant, les exercices classiquement utilisés comme le Nordic hamstring ne soumettent pas les ischio-jambiers à un niveau d'allongement spécifique au sprint. Dès lors, l'objectif de cette thèse était d'évaluer le fonctionnement des ischio-jambiers à différents niveaux d'allongement musculo- tendineux puis de transposer dans la pratique les résultats obtenus afin de concevoir des exercices plus spécifiques aux besoins des athlètes. Avant cela, une première partie avait pour but de proposer de nouvelles méthodes d'évaluation de terrain des ischio-jambiers. Les différents travaux réalisés pour cette thèse ont permis : 1) de proposer deux nouveaux outils de terrain pour l'évaluation de la flexibilité et de la force des ischio-jambiers ; 2) de montrer que le niveau d'allongement influence directement la force produite par les ischio-jambiers et de suggérer que ce niveau d'allongement semble être un stimulus au moins aussi déterminant que le mode de contraction musculaire pour générer des adaptations de l'architecture musculaire propices à la diminution du risque de blessure ; 3) de proposer des modalités spécifiques de renforcement des ischio-jambiers destinées aux sprinteurs dans une perspective de prévention des blessures et de montrer l'efficacité de ces recommandations sur l'amélioration d'un certain nombre de facteurs de risque de blessure. Finalement, ce travail a ouvert de nouvelles perspectives allant de la proposition d'exercices de renforcement de terrain au développement d'un système motorisé spécifique au sprint permettant le renforcement et l'évaluation de la force des ischio-jambiers en passant par différents projets de recherche. -- High-speed running sports accounts for the majority of hamstring strains. The terminal swing phase of the running cycle is believed to be the most hazardous as the hamstrings are undergoing an active lengthening contraction in a long muscle length position. Prevention-based strength training relies mainly on eccentric exercises. However, most hamstrings exercises like the Nordic hamstring are performed at an inadequately low hip-flexion angle. Thus, the objective of this thesis was to assess the hamstring function at different muscle lengths and depending on the obtained results to design strength exercises more specific to the athlete's need. Before that, a first part of this thesis aimed to develop new assessment methods of the hamstring on site. The different studies included in the present thesis allowed: 1) to propose two new methods to test the hamstring flexibility and strength on the field; 2) to show that the hamstring muscle length directly influences its level of strength, and to suggest that the training range of motion could be a dominant stimulus (as important than contraction type) for modifying the muscle architecture, which leads to a decrease in hamstring injury risk; 3) to define sprint specific parameters for prevention-based strength training, and to show the efficiency of these recommendations on the improvement of several injury risk factors for the hamstring. Finally, this thesis proposed new perspectives: 1) new strength exercises on site; 2) the development of a motorised device specific for the sprint which could be used to strength and to assess the hamstring; 3) several future research projects.