884 resultados para Cost Estimation System
Resumo:
Human tremor can be defined as a somewhat rhythmic and quick movement of one or more body parts. In some people, it is a symptom of a neurological disorder. From the mathematical point of view, human tremor can be defined as a weighted contribution of different sinusoidal signals which causes oscillations of some parts of the body. This sinusoidal is repeated over time, but its amplitude and frequency change slowly. This is why amplitude and frequency are considered important factors in the tremor characterization, and thus for its diagnosis. In this paper, a tool for the prediagnosis of the human tremor is presented. This tool uses a low cost device (<$40) and allows to compute the main factors of the human tremor accurately. Real cases have been tested using the algorithms developed in this investigation. The patients suffered from different tremor severities, and the components of amplitude and frequency were computed using a series of tests. These additional measures will help the experts to make better diagnoses allowing them to focus on specific stages of the test or get an overview of these tests. From the experimental, we stated that not all tests are valid for every patient to give a diagnosis. Guided by years of experience, the expert will decide which test or set of tests are the most appropriate for a patient.
Resumo:
In this project, we propose the implementation of a 3D object recognition system which will be optimized to operate under demanding time constraints. The system must be robust so that objects can be recognized properly in poor light conditions and cluttered scenes with significant levels of occlusion. An important requirement must be met: the system must exhibit a reasonable performance running on a low power consumption mobile GPU computing platform (NVIDIA Jetson TK1) so that it can be integrated in mobile robotics systems, ambient intelligence or ambient assisted living applications. The acquisition system is based on the use of color and depth (RGB-D) data streams provided by low-cost 3D sensors like Microsoft Kinect or PrimeSense Carmine. The range of algorithms and applications to be implemented and integrated will be quite broad, ranging from the acquisition, outlier removal or filtering of the input data and the segmentation or characterization of regions of interest in the scene to the very object recognition and pose estimation. Furthermore, in order to validate the proposed system, we will create a 3D object dataset. It will be composed by a set of 3D models, reconstructed from common household objects, as well as a handful of test scenes in which those objects appear. The scenes will be characterized by different levels of occlusion, diverse distances from the elements to the sensor and variations on the pose of the target objects. The creation of this dataset implies the additional development of 3D data acquisition and 3D object reconstruction applications. The resulting system has many possible applications, ranging from mobile robot navigation and semantic scene labeling to human-computer interaction (HCI) systems based on visual information.
Resumo:
AIM: To define the financial and management conditions required to introduce a femtosecond laser system for cataract surgery in a clinic using a fuzzy logic approach. METHODS: In the simulation performed in the current study, the costs associated to the acquisition and use of a commercially available femtosecond laser platform for cataract surgery (VICTUS, TECHNOLAS Perfect Vision GmbH, Bausch & Lomb, Munich, Germany) during a period of 5y were considered. A sensitivity analysis was performed considering such costs and the countable amortization of the system during this 5y period. Furthermore, a fuzzy logic analysis was used to obtain an estimation of the money income associated to each femtosecond laser-assisted cataract surgery (G). RESULTS: According to the sensitivity analysis, the femtosecond laser system under evaluation can be profitable if 1400 cataract surgeries are performed per year and if each surgery can be invoiced more than $500. In contrast, the fuzzy logic analysis confirmed that the patient had to pay more per surgery, between $661.8 and $667.4 per surgery, without considering the cost of the intraocular lens (IOL). CONCLUSION: A profitability of femtosecond laser systems for cataract surgery can be obtained after a detailed financial analysis, especially in those centers with large volumes of patients. The cost of the surgery for patients should be adapted to the real flow of patients with the ability of paying a reasonable range of cost.
Resumo:
Federal Highway Administration, Washington, D.C.
Resumo:
National Highway Traffic Safety Administration, Washington, D.C.
Resumo:
Federal Highway Administration, Office of Engineering and Highway Operations Research and Development, McLean, Va.
Resumo:
Federal Highway Administration, Office of Engineering and Highway Operations Research and Development, McLean, Va.
Resumo:
"OTA-H-262"--P. [4] of cover.
Resumo:
National Highway Traffic Safety Administration, Washington, D.C.
Resumo:
National Highway Traffic Safety Administration, Washington, D.C.
The statistical estimation of throughput and turnaround functions for a university computer system /
Resumo:
Vita.
Resumo:
Cover-title.
Resumo:
Cover title.
Resumo:
Mode of access: Internet.
Resumo:
Mode of access: Internet.