550 resultados para BFRP rods


Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: This study aims to identify which aspects of the pupil light reflex are most influenced by rods and cones independently by analyzing pupil recordings from different mouse models of photoreceptor deficiency. METHODS: One-month-old wild type (WT), rodless (Rho-/-), coneless (Cnga3-/-), or photoreceptor less (Cnga3-/-; Rho-/- or Gnat1-/-) mice were subjected to brief red and blue light stimuli of increasing intensity. To describe the initial dynamic response to light, the maximal pupillary constriction amplitudes and the derivative curve of the first 3 seconds were determined. To estimate the postillumination phase, the constriction amplitude at 9.5 seconds after light termination was related to the maximal constriction amplitude. RESULTS: Rho-/- mice showed decreased constriction amplitude but more prolonged pupilloconstriction to all blue and red light stimuli compared to wild type mice. Cnga3-/- mice had constriction amplitudes similar to WT however following maximal constriction, the early and rapid dilation to low intensity blue light was decreased. To high intensity blue light, the Cnga3-/- mice demonstrated marked prolongation of the pupillary constriction. Cnga3-/-; Rho-/- mice had no pupil response to red light of low and medium intensity. CONCLUSIONS: From specific gene defective mouse models which selectively voided the rod or cone function, we determined that mouse rod photoreceptors are highly contributing to the pupil response to blue light stimuli but also to low and medium red stimuli. We also observed that cone cells mainly drive the partial rapid dilation of the initial response to low blue light stimuli. Thus photoreceptor dysfunction can be derived from chromatic pupillometry in mouse models.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Guanylate cyclase activating proteins are EF-hand containing proteins that confer calcium sensitivity to retinal guanylate cyclase at the outer segment discs of photoreceptor cells. By making the rate of cGMP synthesis dependent on the free intracellular calcium levels set by illumination, GCAPs play a fundamental role in the recovery of the light response and light adaptation. The main isoforms GCAP1 and GCAP2 also localize to the synaptic terminal, where their function is not known. Based on the reported interaction of GCAP2 with Ribeye, the major component of synaptic ribbons, it was proposed that GCAP2 could mediate the synaptic ribbon dynamic changes that happen in response to light. We here present a thorough ultrastructural analysis of rod synaptic terminals in loss-of-function (GCAP1/GCAP2 double knockout) and gain-of-function (transgenic overexpression) mouse models of GCAP2. Rod synaptic ribbons in GCAPs−/− mice did not differ from wildtype ribbons when mice were raised in constant darkness, indicating that GCAPs are not required for ribbon early assembly or maturation. Transgenic overexpression of GCAP2 in rods led to a shortening of synaptic ribbons, and to a higher than normal percentage of club-shaped and spherical ribbon morphologies. Restoration of GCAP2 expression in the GCAPs−/− background (GCAP2 expression in the absence of endogenous GCAP1) had the striking result of shortening ribbon length to a much higher degree than overexpression of GCAP2 in the wildtype background, as well as reducing the thickness of the outer plexiform layer without affecting the number of rod photoreceptor cells. These results indicate that preservation of the GCAP1 to GCAP2 relative levels is relevant for maintaining the integrity of the synaptic terminal. Our demonstration of GCAP2 immunolocalization at synaptic ribbons at the ultrastructural level would support a role of GCAPs at mediating the effect of light on morphological remodeling changes of synaptic ribbons.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Macroscopic samples of fullerene nanostructures are obtained in a modified arc furnace using the electric arc method with a Helium atmosphere at low pressures. High purity graphite rods are used as electrodes but, when drilled and the orifices filled with powders of transition metals (Fe, Co, Ni) acting as catalysts, the resulting particles are carbon nanostructures of the fullerene family, known as Single Wall Nanotubes (SWNTs). They have typical diameters of 1.4 nm, lengths up to tenths of microns and they are arranged together in bundles containing several SWNTs. Those samples are observed and analyzed using Scanning Electron Microscopy (SEM) and Transmission Electron Microscopy (TEM) techniques.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper provides a map of the scientific productivity of authors affiliated to a Spanish institution and who have addressed one of the most important current topics in schizophrenia: The study of cognitive performance. A search of the Web of Science yielded 125 articles that met the inclusion criteria. In order to provide a comprehensive overview of scientific productivity, we examine several bibliometric indicators, concerning both productivity and impact or visibility. The analysis also focuses on qualitative aspects of key theoretical importance, such as the kinds of cognitive functions that are most often assessed and the tests most widely used to evaluate them in clinical practice. The study shows that interest in the subject of cognitive function in schizophrenia has increased considerably in Spain since the beginning of this century. The results also highlight the need to standardize the type of tests to be used in the cognitive assessment of patients with schizophrenia.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: The relevance of persistent cognitive deficits to the pathogenesis and prognosis of bipolar disorders (BD) is understudied, and its translation into clinical practice has been limited by the absence of brief methods assessing cognitive status in Psychiatry. This investigation assessed the psychometric properties of the Spanish version of the Screen for Cognitive Impairment in Psychiatry (SCIP-S) for the detection of cognitive impairment in BD. Methods: After short training, psychiatrists at 40 outpatient clinics administered the SCIP three times over two weeks to a total of 76 consecutive type I BD admissions. Experienced psychologists also administered a comprehensive battery of standard neuropsychological instruments to clinical sample and 45 healthy control subjects. Results: Feasibility was supported by a brief administration time (approximately 15 minutes) and minimal scoring errors. The reliability of the SCIP was confirmed by good equivalence of forms, acceptable stability (ICC range 0.59 to 0.87) and adequate internal consistency (Chronbach's alpha of 0.74). Construct validity was granted by extraction of a single factor (accounting 52% of the variance), acceptable correlations with conventional neuropsychological instruments, and a clear differentiation between bipolar I and normal samples. Efficiency was also provided by the adequate sensitivity and specificity. Limitations: The sample size is not very large. The SCIP and the neurocognitive battery do not cover all potentially relevant cognitive domains. Also, sensitivity to change remains unexplored. Conclusion: With minimal training, physicians obtained a reliable and valid estimate of cognitive impairment in approximately 15 minutes from an application of the SCIP to type I BD patients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: The relevance of persistent cognitive deficits to the pathogenesis and prognosis of bipolar disorders (BD) is understudied, and its translation into clinical practice has been limited by the absence of brief methods assessing cognitive status in Psychiatry. This investigation assessed the psychometric properties of the Spanish version of the Screen for Cognitive Impairment in Psychiatry (SCIP-S) for the detection of cognitive impairment in BD. Methods: After short training, psychiatrists at 40 outpatient clinics administered the SCIP three times over two weeks to a total of 76 consecutive type I BD admissions. Experienced psychologists also administered a comprehensive battery of standard neuropsychological instruments to clinical sample and 45 healthy control subjects. Results: Feasibility was supported by a brief administration time (approximately 15 minutes) and minimal scoring errors. The reliability of the SCIP was confirmed by good equivalence of forms, acceptable stability (ICC range 0.59 to 0.87) and adequate internal consistency (Chronbach's alpha of 0.74). Construct validity was granted by extraction of a single factor (accounting 52% of the variance), acceptable correlations with conventional neuropsychological instruments, and a clear differentiation between bipolar I and normal samples. Efficiency was also provided by the adequate sensitivity and specificity. Limitations: The sample size is not very large. The SCIP and the neurocognitive battery do not cover all potentially relevant cognitive domains. Also, sensitivity to change remains unexplored. Conclusion: With minimal training, physicians obtained a reliable and valid estimate of cognitive impairment in approximately 15 minutes from an application of the SCIP to type I BD patients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Cyclosporine-A-loaded PLGA implants were developed intended for ocular route. Implants were prepared using solvent extraction/evaporation technique followed by casting of the cake into rods in a heated surface. XRD patterns showed that cyclosporine-A was completely incorporated into PLGA. FTIR and DSC results indicated alterations on drug molecular conformation aiming to reach the most stable thermodynamic conformation at polymer/drug interface. Implants provided controlled/sustained in vitro release of the drug. During the first 7 weeks, the drug release was controlled by the diffusion of the cyclosporine-A; and between 7-23 week period, the drug diffusion and degradation of PLGA controlled the drug release.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The irrigation management based on the monitoring of the soil water content allows for the minimization of the amount of water applied, making its use more efficient. Taking into account these aspects, in this work, a sensor for measuring the soil water content was developed to allow real time automation of irrigation systems. This way, problems affecting crop yielding such as irregularities in the time to turn on or turn off the pump, and excess or deficit of water can be solved. To develop the sensors were used stainless steel rods, resin, and insulating varnish. The sensors measuring circuit was based on a microcontroller, which gives its output signal in the digital format. The sensors were calibrated using soil of the type “Quartzarenic Neosoil”. A third order polynomial model was fitted to the experimental data between the values of water content corresponding to the field capacity and the wilting point to correlate the soil water content obtained by the oven standard method with those measured by the electronic circuit, with a coefficient of determination of 93.17%, and an accuracy in the measures of ±0.010 kg kg-1. Based on the results, it was concluded that the sensor and its implemented measuring circuit can be used in the automation process of irrigation systems.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The determination of volumetric water content of soils is an important factor in irrigation management. Among the indirect methods for estimating, the time-domain reflectometry (TDR) technique has received a significant attention. Like any other technique, it has advantages and disadvantages, but its greatest disadvantage is the need of calibration and high cost of acquisition. The main goal of this study was to establish a calibration model for the TDR equipment, Trase System Model 6050X1, to estimate the volumetric water content in a Distroferric Red Latosol. The calibration was carried out in a laboratory with disturbed soil samples under study, packed in PVC columns of a volume of 0.0078m³. The TDR probes were handcrafted with three rods and 0.20m long. They were vertically installed in soil columns, with a total of five probes per column and sixteen columns. The weightings were carried out in a digital scale, while daily readings of dielectric constant were obtained in TDR equipment. The linear model θν = 0.0103 Ka + 0.1900 to estimate the studied volumetric water content showed an excellent coefficient of determination (0.93), enabling the use of probes in indirect estimation of soil moisture.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Four 3-4 month-old chinchillas (Chinchilla lanigera) from a commercial flock of 395 chinchillas, were found dead with evidence of previous diarrhea and prolapsed rectum. A fifth 8 month-old chinchilla died 8 hours after being found recumbent, apathetic, diarrheic and with a prolapsed rectum. Two chinchillas were necropsied and observed gross lesions consisted of extensive hemorrhagic enteritis, mild pulmonary edema and enlarged and yellow liver; this latter finding was particularly prominent in the chinchilla presenting longer clinical course. Histologically there was necrotizing enteritis associated with abundant bacterial rods aggregates in the intestinal surface epithelium and within the lamina propria. In the lungs there were small amounts of pink proteinaceous material (edema) in the interstitium and marked vacuolar hepatocellullar degeneration (lipidosis) in the liver. Anaerobic cultures from the intestinal contents of one of the affected chinchillas yielded Clostridium perfringens. Genotyping of this C. perfringens isolate was achieved by multiplex polymerase chain reaction (mPCR) as C. perfringenstype B due to detection of alpha, beta and epsilon-toxin genes. These findings suggest C. perfringens type B as an important cause of sudden or acute death in chinchillas.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The fuel element of LMFBR consists of a bundle of rods wrapped with an helical wire as spacer, surrounded by an hexagonal duct. In the present work, a semi-empirical model is developed to calculate bundle average and subchannel based friction factors and flow redistribution. The obtained results were compared to experimental data and they were considered satisfactory for wide range of geometrical parameters.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The classical treatment of rough wall turbulent boundary layers consists in determining the effect the roughness has on the mean velocity profile. This effect is usually described in terms of the roughness function delta U+. The general implication is that different roughness geometries with the same delta U+ will have similar turbulence characteristics, at least at a sufficient distance from the roughness elements. Measurements over two different surface geometries (a mesh roughness and spanwise circular rods regularly spaced in the streamwise direction) with nominally the same delta U+ indicate significant differences in the Reynolds stresses, especially those involving the wall-normal velocity fluctuation, over the outer region. The differences are such that the Reynolds stress anisotropy is smaller over the mesh roughness than the rod roughness. The Reynolds stress anisotropy is largest for a smooth wall. The small-scale anisotropy and interniittency exhibit much smaller differences when the Taylor microscale Reynolds number and the Kolmogorov-normalized mean shear are nominally the same. There is nonetheless evidence that the small-scale structure over the three-dimensional mesh roughness conforms more closely with isotropy than that over the rod-roughened and smooth walls.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An experimental investigation is performed in a turbulent flow in a seven wire-wrapped rod bundle, mounted in an open air facility. Static pressure distributions are measured on central and peripheral rods. By using a Preston tube, the wall shear stress profiles are experimentally obtained along the perimeter of the rods. The geometric parameters of the test section are P/D=1.20 and H/D=15. The measuring section is located at L/D=40 from the air inlet. It is observed that the dimensionless static pressure and wall shear stress profiles are nearly independent of the Reynolds number and strongly dependent of the wire-spacer position, with abrupt variations of the parameters in the neighborhood of the wires.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fuel elements of PWR type nuclear reactors consist of rod bundles, arranged in a square array, and held by spacer grids. The coolant flows, mainly, axially along the rods. Although such elements are laterally open, experiments are performed in closed type test sections, originating the appearance of subchannels with different geometries. In the present work, utilizing a test section of two bundles of 4x4 pins each, experiments were performed to determine the friction and the grid drag coefficients for the different subchannels and to observe the effect of the grids in the crossflow, in cases of inlet flow maldistribution.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In nuclear reactors, the occurrence of critical heat flux leads to fuel rod overheating with clad fusion and radioactive products leakage. To predict the effects of such phenomenon, experiments are performed using electrically heated rods to simulate operational and accidental conditions of nuclear fuel rods. In the present work, it is performed a theoretical analysis of the drying and rewetting front propagation during a critical heat flux experiment, starting with the application of an electrical power step from steady state condition. After the occurrence of critical heat flux, the drying front propagation is predicted. After a few seconds, a power cut is considered and the rewetting front behavior is analytically observed. Studies performed with various values of coolant mass flow rate show that this variable has more influence on the drying front velocity than on the rewetting one.