Static pressure and wall shear stress distributions in air flow in a seven wire-wrapped rod bundle
| Data(s) |
01/01/2000
|
|---|---|
| Resumo |
An experimental investigation is performed in a turbulent flow in a seven wire-wrapped rod bundle, mounted in an open air facility. Static pressure distributions are measured on central and peripheral rods. By using a Preston tube, the wall shear stress profiles are experimentally obtained along the perimeter of the rods. The geometric parameters of the test section are P/D=1.20 and H/D=15. The measuring section is located at L/D=40 from the air inlet. It is observed that the dimensionless static pressure and wall shear stress profiles are nearly independent of the Reynolds number and strongly dependent of the wire-spacer position, with abrupt variations of the parameters in the neighborhood of the wires. |
| Formato |
text/html |
| Identificador |
http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0100-73862000000200012 |
| Idioma(s) |
en |
| Publicador |
The Brazilian Society of Mechanical Sciences |
| Fonte |
Journal of the Brazilian Society of Mechanical Sciences v.22 n.2 2000 |
| Palavras-Chave | #Wall shear stress #Static pressure distribution #Rod bundles #Nuclear reactors |
| Tipo |
journal article |