857 resultados para ultrasound assisted dissolution-evaporation
Resumo:
The objective of this study was to describe multiple Doppler ultrasound parameters of ductus venosus and inferior vena cava in fetuses at gestational ages ranging from 22 to 38 weeks. In this prospective observational study, Doppler ultrasound exams were performed in 45 healthy fetuses at 22, 26, 34, and 38 weeks. Maximum venous velocity, minimum venous velocity, venous pulsatility index, and venous acceleration time (VAT) (defined as the time between minimum and maximum venous velocity) were evaluated at those gestational periods. Increase in the velocities and decrease in the pulsatility index were observed in these vessels throughout gestational age. The VAT increased with gestational age. The VAT, a Doppler parameter still not described elsewhere, increased during pregnancy could be related to a longer period of time needed to fill the atrium in bigger hearts. In this study, we provide reference values for VAT in healthy fetuses.
Resumo:
We assessed the repair of transverse, 3-mm wide bone gaps created at the distal radius in 28 dogs that were randomly divided into two 14-animal groups; one was the control group and the other received a daily, 20-min application of low-intensity pulsed ultrasound for 100 days. Sequential radiographs, histomorphometrics, bone fluorescent histology and bone vascularity assessments found that all animals from both groups obtained a stage of hypertrophic-type nonunion with fibrocartilage tissue formation throughout the region of osteotomy. However, treated animals exhibited areas of endochondral ossification within the fibrocartilage region. There was no difference in type of vascularity or the newly formed bone process obtained by tetracycline labeling. Application of low-intensity ultrasound was not capable of significantly changing the reparative process and it may not be sufficiently powerful to overcome a combination of local deleterious effects on bone healing, created by gapping, excessive motion and periosteal resection. (E-mail: jbvolpon@fmrp.usp.br) (C) 2010 World Federation for Ultrasound in Medicine & Biology.
Resumo:
Subclinical mastitis is a common and easily disseminated disease in dairy herds. Its routine diagnosis via bacterial culture and biochemical identification is a difficult and time-consuming process. In this work, we show that matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) allows bacterial identification with high confidence and speed (1 d for bacterial growth and analysis). With the use of MALDI-TOF MS, 33 bacterial culture isolates from milk of different dairy cows from several farms were analyzed, and the results were compared with those obtained by classical biochemical methods. This proof-of-concept case demonstrates the reliability of MALDI-TOF MS bacterial identification, and its increased selectivity as illustrated by the additional identification of coagulase-negative Staphylococcus species and mixed bacterial cultures. Matrix-assisted laser desorption-ionization mass spectrometry considerably accelerates the diagnosis of mastitis pathogens, especially in cases of subclinical mastitis. More immediate and efficient animal management strategies for mastitis and milk quality control in the dairy industry can therefore be applied.
Resumo:
Purpose: The aim of this research was to assess the dimensional accuracy of orbital prostheses based on reversed images generated by computer-aided design/computer-assisted manufacturing (CAD/CAM) using computed tomography (CT) scans. Materials and Methods: CT scans of the faces of 15 adults, men and women older than 25 years of age not bearing any congenital or acquired craniofacial defects, were processed using CAD software to produce 30 reversed three-dimensional models of the orbital region. These models were then processed using the CAM system by means of selective laser sintering to generate surface prototypes of the volunteers` orbital regions. Two moulage impressions of the faces of each volunteer were taken to manufacture 15 pairs of casts. Orbital defects were created on the right or left side of each cast. The surface prototypes were adapted to the casts and then flasked to fabricate silicone prostheses. The establishment of anthropometric landmarks on the orbital region and facial midline allowed for the data collection of 31 linear measurements, used to assess the dimensional accuracy of the orbital prostheses and their location on the face. Results: The comparative analyses of the linear measurements taken from the orbital prostheses and the opposite sides that originated the surface prototypes demonstrated that the orbital prostheses presented similar vertical, transversal, and oblique dimensions, as well as similar depth. There was no transverse or oblique displacement of the prostheses. Conclusion: From a clinical perspective, the small differences observed after analyzing all 31 linear measurements did not indicate facial asymmetry. The dimensional accuracy of the orbital prostheses suggested that the CAD/CAM system assessed herein may be applicable for clinical purposes. Int J Prosthodont 2010;23:271-276.
Resumo:
Introduction: The aim of this study was to evaluate the biofilm dissolution and cleaning ability of different irrigant solutions on intraorally infected dentin. Methods: One hundred twenty bovine dentin specimens were infected intraorally by using a removable orthodontic device. Thirty samples were used for each irrigant solution: 2% chlorhexidine and 1%, 2.5%, and 5.25% sodium hypochlorite (NaOCl). The solutions were used for 5, 15, and 30 minutes and at 2 experimental volumes, 500 mu L and 1 mL. The samples were stained by using acridine orange dye before and after the experiments and evaluated by using a confocal microscope. The percentage of biofilm, isolated cells, and noncolonized dentin was measured by using a grid system. Differences in the reduction or increase of the studied parameters were assessed by using nonparametric methods (P < .05). Results: The higher values of biofilm dissolution and noncolonized dentin were found in the 30-minute NaOCl group and in the 5-minute and 15-minute groups of 5.25% NaOCL. The use of 2% chlorhexidine solution did not improve the biofilm dissolution or increase the cleaning of the dentin in comparison with the NaOCl solutions (P < .05). Conclusions: Two percent chlorhexidine does not dissolve the biofilms. Thirty minutes of NaOCl are necessary to have higher values of biofilm dissolution and to increase the cleaning of the dentin independently of the concentration in comparison with the 5-minute and 15-minute contact times. (J Endod 2011;37:1134-1138)
Resumo:
Objectives: This study examined the retention of solvents within experimental HEMA/solvent primers after two conditions for solvent evaporation: from a free surface or from dentine surface. Methods: Experimental primers were prepared by mixing 35% HEMA with 65% water, methanol, ethanol or acetone (v/v). Aliquots of each primer (50 mu l) were placed on glass wells or they were applied to the surface of acid-etched dentine cubes (2 mm x 2 mm x 2 mm) (n = 5). For both conditions (i.e. from free surface or dentine cubes), change in primers mass due to solvent evaporation was gravimetrically measured for 10 min at 51% RH and 21 degrees C. The rate of solvent evaporation was calculated as a function of loss of primers mass (%) over time. Data were analysed by two-way ANOVA and Student-Newman-Keuls (p < 0.05). Results: There were significant differences between solvent retention(%) and evaporation rate (%/min) depending on the solvent present in the primer and the condition for evaporation (from free surface or dentine cubes) (p < 0.05). For both conditions, the greatest amount of retained solvent was observed for HEMA/water primer. The rate of solvent evaporation for HEMA/acetone primer was almost 2- to 10-times higher than for HEMA/water primer depending whether evaporation occurred, respectively, from a free surface or dentine cubes. The rate of solvent evaporation varied with time, being in general highest at the earliest periods. Conclusions: The rate of solvent evaporation and its retention into HEMA/solvent primers was influenced by the type of the solvent and condition allowed for their evaporation. (C) 2009 Elsevier Ltd. All rights reserved.
Resumo:
To evaluate several protocols for the application of ultrasound during removal of cast posts with varying core configurations cemented with zinc phosphate. Sixty maxillary canines were distributed into three groups (n = 20): group 1 - core with 5 mm diameter/height and post diameter of 1.3 mm; groups 2 and 3 - core with the same diameter as the post (1.3 mm) and heights of 5 mm and 3 mm, respectively. Posts/cores were cemented using a standard technique with zinc phosphate cement. Each group was divided into two subgroups according to the ultrasonic vibration mode: point vibration - ultrasonic vibration applied to the core surface for 5 s, on each face totalling 25 s; alternate vibration - intermittent application of ultrasonic vibration for 10 s to the labial and lingual surfaces, 10 s to the mesial and distal surfaces and 5 s to the incisal surface, totalling 25 s. The specimens were submitted to the tensile test using an Instron machine (1 mm min(-1)) and results were analysed by anova and t-test. The failure type was also analysed. Statistical analysis showed significant differences between groups relating to the core preparations (P < 0.05). The lowest mean values of traction force were obtained for group 3 (46.1 +/- 7.7 N), followed by group 2 (89.0 +/- 2.7 N) and group 1 (160.4 +/- 7.5 N). Regarding ultrasonic vibration, the lowest mean was observed with alternate vibration (81.1 +/- 10.1 N), which was significantly lower than the point vibration (115.9 +/- 9.5 N) (P < 0.05). Cohesive failure occurred in all cases. A reduction in core diameter/height and intermittent ultrasonic application improved the removal of cast posts cemented with zinc phosphate.
Resumo:
Conventional methods for detecting differences in microsatellite repeat lengths rely on electrophoretic fractionation on long denaturing polyacrylamide gels, a time-consuming and labor-intensive method. Therefore, there is a need for the development of new and rapid approaches to routinely detect such length polymorphisms. The advent of techniques allowing the coupling of DNA molecules to solid surfaces has provided new prospects in the area of mutation. We describe here the development and optimization of the ligase-assisted spacer addition (LASA) method, a novel and rapid procedure based on an ELISA format to measure microsatellite repeat lengths. The LASA assay was successfully applied to a set of 11 bird samples to assess its capability as a genotyping method.
Resumo:
Growing evidence supports low-intensity pulsed ultrasound (US) as an osteogenic mechanical stimulus. Its effects on isolated bone cells and on fractured bone are established. However, its effects on osteoporosis are not clear. This study examined US effects on ovariectomy (OVX) induced bone changes within the rodent hindlimb (distal femur and proximal tibia), and on normal bone in animals following sham-OVX. Animals were exposed to daily unilateral active-US and contralateral inactive-US for 12 weeks. Bone status was assessed using dual energy X-ray absorptiometry and histomorphometry. Ovariectomy resulted in significant bone changes. Low-intensity pulsed US did not influence these changes. These results suggest that the US dose introduced may not be a beneficial treatment for osteoporosis, and that intact bone may be less sensitive to US than fractured bone and isolated bone cells. This may relate to the biophysical mechanisms of action of US, US-bone interactions and tissue level processes taking place.
Resumo:
Perineal ultrasound was used to detect and quantify levator activity by measuring the displacement of the internal urethral meatus against the inferoposterior margin of the symphysis pubis, Women who had previously been instructed in pelvic floor muscle exercises were more likely to contract the levator muscle when asked to do so than were those without previous instruction (P
Resumo:
A prospective clinical study was carried out to evaluate the influence of posture on perineal ultrasound imaging parameters. One hundred and thirty-two consecutive women presenting with symptoms of lower urinary tract dysfunction were examined by multichannel videourodynamics and perineal ultrasound, both supine and standing. Ultrasound included color Doppler imaging when available, i.e. in a subgroup of 99 patients. The position of the bladder neck at rest was higher in the supine position (P
Resumo:
In a prospective study 105 patients with symptoms of stress incontinence underwent video-urodynamic testing, including resting urethral pressure profilometry and translabial ultrasound. The urethral pressure profile (UPP) included maximum urethral closure pressure (MUCP), functional length (FL) and area under the curve (AUC). Ultrasound parameters included urethral thickness, urethral rotation and bladder neck descent, as well as funneling/opening of the internal urethral meatus on Valsalva maneuver. Levator contraction strength was assessed measuring the cranioventral displacement of the internal meatus. Negative correlations between UPP data and age, parity and previous surgery were observed which were consistent with literature data. There was a positive correlation :between the urethral AP diameter on ultrasound and the MUCP, which agrees with reports showing reduced sphincter thickness or volume in stress-incontinent women. Hypermobility on ultrasound did not correlate with UPP data. However, a lower MUCP correlated with extensive opening of the bladder neck. Finally, there was a trend towards poorer pelvic floor function with lower MUCP measurements.
Resumo:
If the Internet could be used as a method of transmitting ultrasound images taken in the field quickly and effectively, it would bring tertiary consultation to even extremely remote centres. The aim of the study was to evaluate the maximum degree of compression of fetal ultrasound video-recordings that would not compromise signal quality. A digital fetal ultrasound videorecording of 90 s was produced, resulting in a file size of 512 MByte. The file was compressed to 2, 5 and 10 MByte. The recordings were viewed by a panel of four experienced observers who were blinded to the compression ratio used. Using a simple seven-point scoring system, the observers rated the quality of the clip on 17 items. The maximum compression ratio that was considered clinically acceptable was found to be 1:50-1:100. This produced final file sizes of 5-10 MByte, corresponding to a screen size of 320 x 240 pixels, running at 15 frames/s. This study expands the possibilities for providing tertiary perinatal services to the wider community.
Resumo:
We have established a realtime fetal tele-ultrasound consultation service in Queensland, which has been integrated into our routine clinical practice, The service, which uses ISDN transmission at 384 kbit/s, allows patients in Townsville to be examined by subspecialists in Brisbane, 1500 km away. For the 90 tele-ultrasound consultations performed for the first 71 patients, 90% of the babies have been delivered, and outcome data have been received on all the pregnancies. All significant anomalies and diagnoses have been confirmed. The referring clinicians would have physically referred 24 of the 71 patients to Brisbane in the absence of telemedicine. A crude cost-benefit calculation suggests that the tele-ultrasound service resulted in a net saving of A$6340, and at the same time enabled almost four times the number of consultations to be carried out.