976 resultados para standardization
Resumo:
To obtain a high quality EMG acquisition, the signal must be recorded as far away as possible from muscle innervations and tendon zones, which are known to shift during dynamic contractions. This study describes a methodology, using commercial bipolar electrodes, to identify better electrode positions for superficial EMG of lower limb muscles during dynamic contractions. Eight female volunteers participated in this study. Myoelectric signals of the vastus lateralis, gastrocnemius medialis, peroneus longus and tibialis anterior muscles were acquired during maximum isometric contractions using bipolar electrodes. The electrode positions of each muscle were selected assessing SENIAM and then, other positions were located along the length of muscle up and down the SENIAM site. The raw signal (density), the linear envelopes, the RMS value, the motor point site, the position of the IZ and its shift during dynamic contractions were taken into account to select and compare electrode positions. For vastus lateralis and peroneus longus, the best sites were 66% and 25% of muscle length, respectively (similar to SENIAM location). The position of the tibialis anterior electrodes presented the best signal at 47.5% of its length (different from SENIAM location). The position of the gastrocnemius medialis electrodes was at 38% of its length and SENIAM does not specify a precise location for signal acquisition. The proposed method should be considered as another methodological step in every EMG study to guarantee the quality of the signal and subsequent human movement interpretations. (C) 2009 Elsevier B.V. All rights reserved.
Resumo:
Objective: A new adjustable pinch has been developed for producing a crush injury, with a previously known load of 5 kg, on a 5 mm-long segment of the nerve. Methods: Stainless steel was the material selected for building the pinch due its durability and possibility of sterilization with anti-septic substances, which are often corrosive. The crushing load of the pinch is adjustable by increasing or decreasing the tension of the spring by means of a screw used for calibration, which is performed by a load cell. Result: This pinch has been used in a few experimental investigations and was shown to be as efficient as both the universal testing machine and the dead weight machine, previously used. Conclusion: The developed pinch has the advantages of being portable and user-friendly. In addition, the pinch is cheap and allows for the standardization of the applied load.
Resumo:
The present study compared two heating methods currently used for antigen retrieval (AR) immunostaining: the microwave oven and the steam cooker. Myosin-V, a molecular motor involved in vesicle transport, was used as a neuronal marker in honeybee Apis mellifera brains fixed in formalin. Overall, the steam cooker showed the most satisfactory AR results. At 100 degrees C, tissue morphology was maintained and revealed epitope recovery, while evaporation of the AR solution was markedly reduced; this is important for stabilizing the sodium citrate molarity of the AR buffer and reducing background effects. Standardization of heat-mediated AR of formalin-fixed and paraffin-embedded tissue sections results in more reliable immunostaining of the honeybee brain.
Resumo:
Objective To investigate whether standardization of the multiplanar view (SMV) when evaluating the uterus using three-dimensional ultrasonography (3D-US) improves intra-and interobserver reliability and agreement with regard to endometrial measurement. Methods Two-dimensional (2D) and 3D-US was used to measure endometrial thickness by two observers in 30 women undergoing assisted reproduction treatment. Endometrial volume was measured with Virtual Organ Computer-aided AnaLysis (VOCAL (TM)) in the longitudinal (A) and coronal (C) planes using an unmodified multiplanar view (UMV) and a standardized multiplanar view (SMV). Measurement reliability was evaluated by intraclass correlation coefficient (ICC) and agreement was examined using Bland-Altman plots with limits of agreement (LoA). The ease of outlining the endometrial-myometrial interface was compared between the A-and C-planes using subjective assessment. Results Endometrial volume measurements using the SMV and A-plane were more reliable (intra-and interobserver ICCs, 0.979 and 0.975, respectively) than were measurements of endometrial thickness using 2D-US (intra-and interobserver ICCs, 0.742 and 0.702, respectively) or 3D-US (intra-and interobserver ICCs, 0.890 and 0.784, respectively). The LoAs were narrower for SMV than for UMV. Reliability and agreement were not much different between the A- and C-planes. However the observers agreed that delineating the endometrial-myometrial interface using the A-plane was easier (first and second observer, 50.0 and 46.7%, respectively) or `comparable` (50 and 53.3%, respectively), but never more difficult than using the C-plane. Conclusions Endometrial volume measurements are more reliable than endometrial thickness measurements and are best performed using SMV and the A-plane. Copyright (C) 2011 ISUOG. Published by John Wiley & Sons, Ltd.
Resumo:
P>The determination of normal parameters is an important procedure in the evaluation of the stomatognathic system. We used the surface electromyography standardization protocol described by Ferrario et al. (J Oral Rehabil. 2000;27:33-40, 2006;33:341) to determine reference values of the electromyographic standardized indices for the assessment of muscular symmetry (left and right side, percentage overlapping coefficient, POC), potential lateral displacing components (unbalanced contractile activities of contralateral masseter and temporalis muscles, TC), relative activity (most prevalent pair of masticatory muscles, ATTIV) and total activity (integrated areas of the electromyographic potentials over time, IMPACT) in healthy Brazilian young adults, and the relevant data reproducibility. Electromyography of the right and left masseter and temporalis muscles was performed during maximum teeth clenching in 20 healthy subjects (10 women and 10 men, mean age 23 years, s.d. 3), free from periodontal problems, temporomandibular disorders, oro-facial myofunctional disorder, and with full permanent dentition (28 teeth at least). Data reproducibility was computed for 75% of the sample. The values obtained were POC Temporal (88 center dot 11 +/- 1 center dot 45%), POC masseter (87 center dot 11 +/- 1 center dot 60%), TC (8 center dot 79 +/- 1 center dot 20%), ATTIV (-0 center dot 33 +/- 9 center dot 65%) and IMPACT (110 center dot 40 +/- 23 center dot 69 mu V/mu V center dot s %). There were no statistical differences between test and retest values (P > 0 center dot 05). The Technical Errors of Measurement (TEM) for 50% of subjects assessed during the same session were 1 center dot 5, 1 center dot 39, 1 center dot 06, 3 center dot 83 and 10 center dot 04. For 25% of the subjects assessed after a 6-month interval, the TEM were 0 center dot 80, 1 center dot 03, 0 center dot 73, 12 center dot 70 and 19 center dot 10. For all indices, there was good reproducibility. These electromyographic indices could be used in the assessment of patients with stomatognathic dysfunction.
Resumo:
Introduction: This study assessed in vitro the physicochemical properties of 2 methacrylate resin-based sealers (Epiphany SE and Hybrid Root SEAL), comparing the results with a well-established epoxy resin-based sealer (AH Plus). Methods: Five samples of each material were used for each test (setting time, flow, radiopacity, dimensional change after setting, and solubility) according to American National Standards Institute/American Dental Association (ANSI/ADA) Specification 57. The samples were assigned to 3 groups: I, AH Plus; II, Epiphany SE; and III, Hybrid Root SEAL. The distilled and deionized water used at the solubility test was submitted to atomic absorption spectrometry to observe the presence of Ca2+, K+, Ni2+, and Zn2+ ions. In addition, the surface morphology of the specimens was analyzed by means of scanning electron microscopy (SEM). Statistical analysis was performed by using one-way analysis of variance and Tukey-Kramer test (P < .05). Results: Flow, radiopacity, and solubility of all sealers were in accordance with ANSI/ADA. The setting time of Hybrid Root SEAL did not agree with ANSUADA requirements. The dimensional change of all sealers was greater than the values considered acceptable by ANSI/ADA. The spectrometry analysis showed significant Ca2+ ions release for AH Plus. In SEM analysis, Hybrid Root SEAL presented spherical monomers with inferior size than AH Plus and Epiphany SE. Conclusions: It might be concluded that physicochemical properties of the tested sealers conformed to ANSI/ADA (2000) standardization, except for the setting time of Hybrid Root SEAL and the dimensional change of all sealers, which did not fulfill the ANSI/ADA requirements. (J Endod 2010;36:1531-1536)
Resumo:
P>Aim To assess the physicochemical properties and the surface morphology of AH Plus, Epiphany, and Epiphany SE root canal sealers. Methodology Five samples of each material were employed for each test according to ANSI/ADA specification 57. The samples were assigned to four groups: (i) AH Plus; (ii) Epiphany; (iii) Epiphany + Thinning Resin; (iv) Epiphany SE. The distilled water used during the solubility test was submitted to spectrometry to verify the release of calcium ions. The morphologies of the external surface and the cross-section of the samples were analysed by means of a scanning electron microscope (SEM). Statistical analysis was performed by using One-Way anova and post hoc Tukey-Kramer tests with the null hypothesis set as 5%. Results Setting time, flow and radiopacity results were in accordance with ANSI/ADA requirements whereas the dimensional change of all sealers and solubility of Epiphany did not fulfil ANSI/ADA protocols. AH Plus and Epiphany SE were similar in terms of flow, radiopacity, solubility and dimensional change. The spectrometry test revealed significant calcium ion release from Epiphany with and without the thinning resin. SEM analysis revealed essentially a homogeneous surface with compact layer and some rough areas. Conclusions Setting time, flow, and radiopacity tests conformed to ANSI/ADA standardization. The dimensional change in all groups and the solubility of Epiphany were greater than values considered acceptable, with higher amounts of calcium ion release. Epiphany SE revealed more organized, compacted, and homogeneous polymers in a reduced resin matrix when compared with the other groups.
Resumo:
Laser heating Ar-40/Ar-39 geochronology provides high analytical precision and accuracy, mum-scale spatial resolution. and statistically significant data sets for the study of geological and planetary processes, A newly commissioned Ar-40/Ar-39 laboratory at CPGeo/USP, Sao Paulo, Brazil, equips the Brazilian scientific community with a new powerful tool applicable to the study of geological and cosmochemical processes. Detailed information about laboratory layout, environmental conditions, and instrumentation provides the necessary parameters for the evaluation of the CPGeo/USp Ar-40/Ar-39 suitability to a diverse range of applications. Details about analytical procedures, including mineral separation, irradiation at the IPEN/CNEN reactor at USP, and mass spectrometric analysis enable potential researchers to design the necessary sampling and sample preparation program suitable to the objectives of their study. Finally, the results of calibration tests using Ca and K salts and glasses, international mineral standards, and in-house mineral standards show that the accuracy and precision obtained at the Ar-40/Ar-39 laboratory at CPGeo/USP are comparable to results obtained in the most respected laboratories internationally. The extensive calibration and standardization procedures under-taken ensure that the results of analytical studies carried out in our laboratories will gain immediate international credibility, enabling Brazilian students and scientists to conduct forefront research in earth and planetary sciences.
Resumo:
With the advent of object-oriented languages and the portability of Java, the development and use of class libraries has become widespread. Effective class reuse depends on class reliability which in turn depends on thorough testing. This paper describes a class testing approach based on modeling each test case with a tuple and then generating large numbers of tuples to thoroughly cover an input space with many interesting combinations of values. The testing approach is supported by the Roast framework for the testing of Java classes. Roast provides automated tuple generation based on boundary values, unit operations that support driver standardization, and test case templates used for code generation. Roast produces thorough, compact test drivers with low development and maintenance cost. The framework and tool support are illustrated on a number of non-trivial classes, including a graphical user interface policy manager. Quantitative results are presented to substantiate the practicality and effectiveness of the approach. Copyright (C) 2002 John Wiley Sons, Ltd.
Resumo:
Improvement in analysis and reporting results of osteoarthritis (OA) clinical trials has been recently obtained because of harmonization and standardization of the selection of outcome variables (OMERACT 3 and OARSI). Moreover, OARSI has recently proposed the OARSI responder criteria. This composite index permits presentation of results of symptom modifying clinical trials in OA based on individual patient responses (responder yes/no). The 2 organizations (OMERACT and OARSI) established. a task force aimed at evaluating: (1) the variability of observed placebo and active treatment effects using the OARSI responder criteria; and (2) the possibility of proposing a simplified set of criteria. The conclusions of the task force were presented and discussed during the OMERACT 6 conference, where a simplified set of responder criteria (OMERACT-OARSI set of criteria) was proposed.
Resumo:
Translabial ultrasound is increasingly being used for the assessment of women presenting with pelvic floor dysfunction and incontinence (1,2). However, there is little information on normal values for bladder neck descent, with the two available studies disagreeing widely (3,4). No data has so far been published on mobility of the central and posterior compartment which can now also be assessed by ultrasound (5). This study presents normal values for urethral, bladder, cervical and rectal mobility in a cohort of young, stress continent, nulliparous nonpregnant women. Methods 118 nonpregnant nulliparous Caucasian women between 18 and 23 years of age were recruited for an ongoing twin study of pelvic floor function. Translabial ultrasound assessment of pelvic organ mobility was undertaken supine and after bladder emptying (6,7). The best of at least three effective Valsalva manoeuvres was used for evaluation, with no attempts at standardization of Valsalva pressure. Parameters of anterior compartment mobility were obtained by the use of on-screen calipers; cervical and rectal descent were evaluated on printouts. All examinations were carried out under direct supervision of the first author or by personnel trained by him for at least 100 consecutive assessments. Results The median age of participants in this study was 20 (range 18- 23). Mean body mass index was 23 (range 16.9- 36.7). Of 118 women, 2 were completely unable to perform a Valsalva manoeuvre despite repeated efforts at teaching and were excluded from analysis, as were ten women who complained of urinary stress incontinence, leaving 106 datasets. Average measurements for the parameters ‘retrovesical angle at rest’ (RVA-R) and on Valsalva (RVA-S), urethral rotation, bladder neck mobility, cysto-cele descent, cervical descent and descent of the rectal ampulla are given in Table 1.
Resumo:
Objetivo: Analisar a padronização da coleta do lavado gástrico para diagnóstico de tuberculose em crianças. Métodos: Estudo de revisão sistemática referente aos anos de 1968 a 2008. O levantamento de artigos científicos foi feito nas bases de dados Lilacs, SciELO e Medline, utilizando-se a estratégia de busca ("gastric lavage and tuberculosis" ou "gastric washing and tuberculosis", com o limite "crianças com idade até 15 anos"; e "gastric lavage and tuberculosis and childhood" ou "gastric washing and tuberculosis and childhood"). A análise dos 80 artigos recuperados baseou-se nas informações sobre o protocolo de coleta de lavado gástrico para diagnóstico da tuberculose em crianças: preparo da criança e horas de jejum, horário da coleta, aspiração do resíduo gástrico, volume total aspirado, solução usada para aspiração do conteúdo gástrico, solução descontaminante, solução tampão, e tempo de encaminhamento das amostras para o laboratório. Desses, foram selecionados 14 artigos após análise criteriosa. Resultados: Nenhum artigo explicava detalhadamente todo o procedimento. Em alguns artigos não constavam: quantidade de aspirado gástrico, aspiração antes ou após a instilação de uma solução, solução usada na aspiração gástrica, solução tampão utilizada, tempo de espera entre coleta e processamento do material. Esses resultados mostram inconsistências entre os protocolos de coleta de lavado gástrico. Conclusões: Embora este seja um método secundário no Brasil, reservado a casos que não alcançaram pontuação diagnóstica pelo sistema preconizado pelo Ministério da Saúde, é necessário padronizar a coleta de lavado gástrico para diagnóstico de tuberculose pulmonar na infância.
Resumo:
O texto apresenta os percursos da investigação realizada numa escola pública de ensino médio do município de Santa Teresa, interior do Espírito Santo. Afirma que, nas ações e inventividades cotidianas dos sujeitos praticantes, são tecidos os processos curriculares que dão movimento à pesquisa, considerando esses praticantes como protagonistas das teoriaspráticas curriculares. Problematiza os modos de ser jovem ao discutir os processos de singularização que acontecem nas relações cotidianas, defendendo uma perspectiva teoricoepistemológica que considera os jovens como sujeitos híbridos que habitam entre-lugares culturais, impossibilitando sua localização em identidades idealizadas ou fixas. Aposta nas relações e criações cotidianas, nos movimentos e tessituras dos currículos que se dão em redes coletivas e compartilhadas de saberesfazessentidos, tecidas entre os jovenspraticantes, seus professores e demais habitantes dos cotidianos escolares para além das uniformidades, padronizações e hierarquias das políticas oficiais de currículos. Assume o processo de hibridação que acontece nessas relações, nas discussões ligadas às teoriaspráticas cotidianas e associa a educação e a produção curricular aos processos culturais mais amplos, reconhecendo os limites da criação de uma definição única e precisa de “currículo”. Nesse sentido, defende o fazer curricular como produção de sentidos, argumentando a favor da criação de currículos hibridizados que se constituem em meio a práticas culturais híbridas, onde os movimentos, usos e negociações devem ser considerados nos processos complexos que os constituem, em meio às criações anônimas que se proliferam nos cotidianos. Assume como opção teoricometodologicopolítica as pesquisas com os cotidianos, utilizando narrativastextuaisimagéticas produzidas nos diferentes contextos da pesquisa pelos praticantes. Evidencia, ainda, que a criação da tese se faz no próprio movimento da escrita, num processo de ficção, discutindo questões ligadas às juventudes, à educação profissionalizante, ao ensino médio, aos modos de pesquisa, às relações cotidianas, às redes de singularidades, aos currículos, aos modelos de escola, às magensnarrativas desses processos, entre outras, sem, no entanto, definir os limites desses campos enunciativos, compondo-se, numa mistura intrigante e complexa de sons, gostos, fazeres, dizeres e calares dos percursos de conhecer, compreendendo a maior “marca cotidiana do cotidiano”.
Resumo:
A absorção de água por carcaças de frango na etapa de pré-resfriamento da linha abate representa uma característica de qualidade importante relacionada ao rendimento do produto final. Uma forma de manter o padrão de qualidade de um produto é garantir que as etapas do processo sejam estáveis e replicáveis. Ao empregar o Controle Estatístico de Processo (CEP) é possível obter estabilidade e melhorias nos processos, por meio da redução da variabilidade. Neste contexto, o objetivo deste trabalho foi a aplicação de gráficos de controle, análise de correlação, estatística descritiva, testes de hipóteses e regressão linear múltipla na linha de abate de um abatedouro-frigorífico de aves para monitorar a variabilidade da absorção de água pelas carcaças de frango após a etapa de pré-resfriamento. Como resultado, verificou-se que o teor de absorção de água das carcaças de frango apresentou elevada variabilidade, sendo que 10% (8/80) das carcaças apresentaram absorção de água superior ao limite de 8% definido pela legislação brasileira. Do total de 16 variáveis de entrada analisadas, as mais impactantes no teor de absorção de água foram o “tempo de retenção da carcaça no pré-chiller” e o “tempo de espera da carcaça após a etapa de gotejamento”. Entretanto, o modelo de regressão obtido apresentou baixa correlação (R²=0,16) que foi associada à elevada variabilidade da variável-resposta. Os resultados da estatística descritiva demonstraram que as variáveis de entrada também apresentaram elevada variabilidade, com coeficiente de variação entre 7,95 e 63,5%. Verificou-se, pela análise dos gráficos de controle de medida individual e da amplitude móvel, que 15 das 16 variáveis de entrada se apresentaram fora de controle estatístico assim como a variável-resposta. Baseado no fluxograma e na descrição das etapas da linha de abate, previamente realizados, atribuiu-se à falta de padronização na condução das etapas e de procedimentos para o controle de qualidade das operações na linha de abate como fatores relevantes que poderiam estar associados à presença de causas especiais no processo. Concluiu-se que para reduzir a elevada variabilidade das variáveis e eliminar as causas especiais presentes são necessários ajustes operacionais para, dessa forma, obter um processo mais estável e mais uniforme garantindo o padrão de qualidade das carcaças de frango em relação ao teor de absorção de água.
Resumo:
A resistência a fármacos antituberculose tem constituído uma grande ameaça ao controle da tuberculose em âmbito mundial. A sua detecção precoce permite ao médico instituir um esquema de tratamento mais adequado ao paciente e consequentemente quebrar a cadeia de transmissão dos bacilos. Os testes de sensibilidade a antimicrobianos atuais, embora eficientes, são caros e/ou demorados e/ou trabalhosos. Com base nesta premissa, nos propusemos a desenvolver e padronizar um método fenotípico direto para determinação da sensibilidade do Mycobacterium tuberculosis a antimicrobianos de primeira linha do tratamento da tuberculose. Para o desenvolvimento deste novo teste, utilizaram-se os princípios do método das proporções e do exame de cultura pelo método de Ogawa–Kudoh. O estudo foi dividido em duas fases. A primeira, caracterizada pelo desenvolvimento e padronização do método proposto e a segunda, pela análise da concordância entre o método desenvolvido e o método do MGIT (padrão-ouro). Na primeira fase, foram realizados diversos ensaios para definir: os volumes de absorção e de liberação de líquidos de diferentes tipos de swab, o meio de cultura, as concentrações dos antimicrobianos e o tempo de leitura/interpretação das culturas. Além disso, foi verificado se a amostra deveria ou não ser diluída. Com base nos resultados destes ensaios, padronizou-se o método com: swab comercial, em meio de cultura Ogawa- Kudoh contendo separadamente 0,2 μg/mL de isoniazida, 40,0 μg/mL de rifampicina, 10,0 μg/mL de estreptomicina e 500,0 μg/mL de ácido para-nitrobenzóico. Padronizou-se ainda a inoculação da amostra de escarro de forma direta, ou seja, sem diluir e a leitura/interpretação do resultado do teste no período entre 21 e 28 dias. A análise comparativa entre este método e o teste de sensibilidade a antimicrobianos no sistema MGIT realizada na segunda fase do projeto indicou um índice kappa igual a 1,000, ou seja, uma concordância muito boa em relação ao padrão-ouro. Diante desses resultados promissores, acreditamos que o método desenvolvido apresente um grande potencial para ser utilizado em laboratórios com pouca infra-estrutura, por ser de baixo custo, fácil execução e relativamente rápido.