883 resultados para probabilistic tests
Resumo:
Significant advances were made in the diagnosis of filariasis in the 1990s with the emergence of three new alternative tools: ultrasound and tests to detect circulating antigen using two monoclonal antibodies, Og4C3 and AD12-ICT-card. This study aimed to identify which of these methods is the most sensitive for diagnosis of infection. A total of 256 individuals, all male and carrying microfilariae (1-15,679 MF/mL), diagnosed by nocturnal venous blood samples, were tested by all three techniques. The tests for circulating filarial antigen concurred 100% and correctly identified 246/256 (96.69%) of the positive individuals, while ultrasound detected only 186/256 (73.44%). Of the circulating antigen tests, ICT-card was the most convenient method for identification of Wuchereria bancrofti carriers. It was easy to perform, practical and quick.
Resumo:
BACKGROUND Illiteracy, a universal problem, limits the utilization of the most widely used short cognitive tests. Our objective was to assess and compare the effectiveness and cost for cognitive impairment (CI) and dementia (DEM) screening of three short cognitive tests applicable to illiterates. METHODS Phase III diagnostic test evaluation study was performed during one year in four Primary Care centers, prospectively including individuals with suspicion of CI or DEM. All underwent the Eurotest, Memory Alteration Test (M@T), and Phototest, applied in a balanced manner. Clinical, functional, and cognitive studies were independently performed in a blinded fashion in a Cognitive Behavioral Neurology Unit, and the gold standard diagnosis was established by consensus of expert neurologists on the basis of these results. Effectiveness of tests was assessed as the proportion of correct diagnoses (diagnostic accuracy [DA]) and the kappa index of concordance (k) with respect to gold standard diagnoses. Costs were based on public prices at the time and hospital accounts. RESULTS The study included 139 individuals: 47 with DEM, 36 with CI, and 56 without CI. No significant differences in effectiveness were found among the tests. For DEM screening: Eurotest (k = 0.71 [0.59-0.83], DA = 0.87 [0.80-0.92]), M@T (k = 0.72 [0.60-0.84], DA = 0.87 [0.80-0.92]), Phototest (k = 0.70 [0.57-0.82], DA = 0.86 [0.79-0.91]). For CI screening: Eurotest (k = 0.67 [0.55-0.79]; DA = 0.83 [0.76-0.89]), M@T (k = 0.52 [0.37-0.67]; DA = 0.80 [0.72-0.86]), Phototest (k = 0.59 [0.46-0.72]; DA = 0.79 [0.71-0.86]). There were no differences in the cost of DEM screening, but the cost of CI screening was significantly higher with M@T (330.7 ± 177.1 €, mean ± sd) than with Eurotest (294.1 ± 195.0 €) or Phototest (296.0 ± 196. 5 €). Application time was shorter with Phototest (2.8 ± 0.8 min) than with Eurotest (7.1 ± 1.8 min) or M@T (6.8 ± 2.2 min). CONCLUSIONS Eurotest, M@T, and Phototest are equally effective. Eurotest and Phototest are both less expensive options but Phototest is the most efficient, requiring the shortest application time.
Resumo:
This paper proposes MSISpIC, a probabilistic sonar scan matching algorithm for the localization of an autonomous underwater vehicle (AUV). The technique uses range scans gathered with a Mechanical Scanning Imaging Sonar (MSIS), the robot displacement estimated through dead-reckoning using a Doppler velocity log (DVL) and a motion reference unit (MRU). The proposed method is an extension of the pIC algorithm. An extended Kalman filter (EKF) is used to estimate the robot-path during the scan in order to reference all the range and bearing measurements as well as their uncertainty to a scan fixed frame before registering. The major contribution consists of experimentally proving that probabilistic sonar scan matching techniques have the potential to improve the DVL-based navigation. The algorithm has been tested on an AUV guided along a 600 m path within an abandoned marina underwater environment with satisfactory results
Resumo:
Understanding why dispersal is sex-biased in many taxa is still a major concern in evolutionary ecology. Dispersal tends to be male-biased in mammals and female-biased in birds, but counter-examples exist and little is known about sex bias in other taxa. Obtaining accurate measures of dispersal in the field remains a problem. Here we describe and compare several methods for detecting sex-biased dispersal using bi-parentally inherited, codominant genetic markers. If gene flow is restricted among populations, then the genotype of an individual tells something about its origin. Provided that dispersal occurs at the juvenile stage and that sampling is carried out on adults, genotypes sampled from the dispersing sex should on average be less likely (compared to genotypes from the philopatric sex) in the population in which they were sampled. The dispersing sex should be less genetically structured and should present a larger heterozygote deficit. In this study we use computer simulations and a permutation test on four statistics to investigate the conditions under which sex-biased dispersal can be detected. Two tests emerge as fairly powerful. We present results concerning the optimal sampling strategy (varying number of samples, individuals, loci per individual and level of polymorphism) under different amounts of dispersal for each sex. These tests for biases in dispersal are also appropriate for any attribute (e.g. size, colour, status) suspected to influence the probability of dispersal. A windows program carrying out these tests can be freely downloaded from http://www.unil.ch/izea/softwares/fstat.html
Resumo:
Although active personal dosemeters (APDs) are not used quite often in hospital environments, the possibility to assess the dose and/or dose rate in real time is particularly interesting in interventional radiology and cardiology (IR/IC) since operators can receive relatively high doses while standing close to the primary radiation field.A study concerning the optimization of the use of APDs in IR/IC was performed in the framework of the ORAMED project, a Collaborative Project (2008-2011) supported by the European Commission within its 7th Framework Program. This paper reports on tests performed with APDs on phantoms using an X-ray facility in a hospital environment and APDs worn by interventionalists during routine practice in different European hospitals.The behaviour of the APDs is more satisfactory in hospitals than in laboratories with respect to the influence of the tube peak high voltage and pulse width, because the APDs are tested in scattered fields with dose equivalent rates generally lower than 1 Sv.h(-1).
Resumo:
Orally transmitted Chagas disease (ChD), which is a well-known entity in the Brazilian Amazon Region, was first documented in Venezuela in December 2007, when 103 people attending an urban public school in Caracas became infected by ingesting juice that was contaminated with Trypanosoma cruzi. The infection occurred 45-50 days prior to the initiation of the sampling performed in the current study. Parasitological methods were used to diagnose the first nine symptomatic patients; T. cruzi was found in all of them. However, because this outbreak was managed as a sudden emergency during Christmas time, we needed to rapidly evaluate 1,000 people at risk, so we decided to use conventional serology to detect specific IgM and IgG antibodies via ELISA as well as indirect haemagglutination, which produced positive test results for 9.1%, 11.9% and 9.9% of the individuals tested, respectively. In other more restricted patient groups, polymerase chain reaction (PCR) provided more sensitive results (80.4%) than blood cultures (16.2%) and animal inoculations (11.6%). Although the classical diagnosis of acute ChD is mainly based on parasitological findings, highly sensitive and specific serological techniques can provide rapid results during large and severe outbreaks, as described herein. The use of these serological techniques allows prompt treatment of all individuals suspected of being infected, resulting in reduced rates of morbidity and mortality.
Resumo:
The performances of two rapid tests and a standard serological test for the diagnosis of visceral leishmaniasis (VL) were compared using sera from 193 patients with VL and 85 controls. The Kala-Azar Detect®, IT-LEISH® and IFI-LH® assays showed sensitivities of 88.1%, 93.3% and 88.6%, respectively, and specificities of 90.6%, 96.5% and 80%, respectively. The sensitivity values were similar for both rapid tests, but the specificity and positive predictive values of IT-LEISH® were higher than the corresponding values for IFI-LH®. Both rapid tests showed satisfactory performances and can be used in primary health care settings; however, IT-LEISH® permits the use of whole blood, making this assay more suitable for bedside diagnosis.
Resumo:
A single strain of Mycobacterium abscessus subsp. bolletii, characterised by a particular rpoB sequevar and two highly related pulsed field gel electrophoresis patterns has been responsible for a nationwide outbreak of surgical infections in Brazil since 2004. In this study, we developed molecular tests based on polymerase chain reaction restriction-enzyme analysis (PRA) and sequencing for the rapid identification of this strain. Sequences of 15 DNA regions conserved in mycobacteria were retrieved from GenBank or sequenced and analysed in silico. Single nucleotide polymorphisms specific to the epidemic strain and located in enzyme recognition sites were detected in rpoB, the 3' region of the 16S rDNA and gyrB. The three tests that were developed, i.e., PRA-rpoB, PRA-16S and gyrB sequence analysis, showed 100%, 100% and 92.31% sensitivity and 93.06%, 90.28% and 100% specificity, respectively, for the discrimination of the surgical strain from other M. abscessus subsp. bolletii isolates, including 116 isolates from 95 patients, one environmental isolate and two type strains. The results of the three tests were stable, as shown by results obtained for different isolates from the same patient. In conclusion, due to the clinical and epidemiological importance of this strain, these tests could be implemented in reference laboratories for the rapid preliminary diagnosis and epidemiological surveillance of this epidemic strain.
Resumo:
The diagnosis of leprosy continues to be based on clinical symptoms and early diagnosis and treatment are critical to preventing disability and transmission. Sensitive and specific laboratory tests are not available for diagnosing leprosy. Despite the limited applicability of anti-phenolic glycolipid-I (PGL-I) serology for diagnosis, it has been suggested as an additional tool to classify leprosy patients (LPs) for treatment purposes. Two formats of rapid tests to detect anti-PGL-I antibodies [ML immunochromatography assay (ICA) and ML Flow] were compared in different groups, multibacillary patients, paucibacillary patients, household contacts and healthy controls in Brazil and Nepal. High ML Flow intra-test concordance was observed and low to moderate agreement between the results of ML ICA and ML Flow tests on the serum of LPs was observed. LPs were "seroclassified" according to the results of these tests and the seroclassification was compared to other currently used classification systems: the World Health Organization operational classification, the bacilloscopic index and the Ridley-Jopling classification. When analysing the usefulness of these tests in the operational classification of PB and MB leprosy for treatment and follow-up purposes, the ML Flow test was the best point-of-care test for subjects in Nepal and despite the need for sample dilution, the ML ICA test yielded better performance among Brazilian subjects. Our results identified possible ways to improve the performance of both tests.
Resumo:
Résumé en français Cadre : Policlinique pédiatrique à Lausanne en Suisse, pays rencontrant une proportion importante de tuberculose au sein de la population de migrants. But : Déterminer les facteurs de risque associés à un test tuberculinique positif (ou test de Mantoux), notamment l'influence du BCG (Bacille Calmette Guérin) et d'un contact avec un personne ayant une tuberculose active. Les patients concernés étaient des enfants examinés dans le cadre d'un contrôle de santé ou dans le cadre d'une étude d'entourage d'un cas déclaré de tuberculose. Méthode : Etude descriptive comprenant des enfants ayant eu un test tuberculinique (2 unités RT23) entre novembre 2002 et avril 2004. L'âge, le sexe, l'anamnèse de contact avec une personne ayant une tuberculose active, la vaccination par le BCG, le pays d'origine et le lieu de naissance (en Suisse ou hors de la Suisse) étaient répertoriés. Résultats : Parmi les 234 enfants de l'étude, 176 (75%) avaient une réaction tuberculinique égal à zéro et 31 (13%) avaient une réaction positive (> 10mm). Dans le modèle de régression linéaire, la taille de la réaction tuberculinique variait significativement selon l'anamnèse de contact avec une personne ayant une tuberculose active, l'âge, l'incidence de la tuberculose dans le pays d'origine et la vaccination par le BCG. Le sexe ou le lieu de naissance n'influençait pas la taille de la réaction. Dans le modèle de régression logistique incluant toutes les valeurs répertoriées, les paramètres significativement associés avec un Mantoux positif étaient l'âge (Odds Ratio = 1.21, 95% CI 1.08 ; 1.35), l'anamnèse de contact avec une personne ayant une tuberculose active (OR = 7.31, 95% CI 2.23 ; 24) et l'incidence de la tuberculose dans le pays d'origine (OR = 1.01, 95% CI 1.00 ; 1.02). Le sexe (OR = 1.18, 95% CI 0.50 ; 2.78) et la vaçcination par le BCG (OR = 2.97, 95% CI 0.91 ; 9.72) n'étaient pas associés avec une réaction tuberculinique positive. Conclusions : L'incidence de la tuberculose dans le pays d'origine, la vaccination par le BCG et l'âge influencent le test de Mantoux (taille ou proportion de réaction > 10mm). Toutefois, le facteur de risque le plus important d'avoir une réaction tuberculinique positive est l'anamnèse de contact avec. une personne ayant une tuberculose active.
Resumo:
Mice experimentally infected with a pathogenic strain of Leptospira interrogans serovar Canicola produced false negative results (prozone effect) in a microscopic agglutination test (MAT). This prozone effect occurred in several serum samples collected at different post-infection times, but it was more prominent in samples collected from seven-42 days post-infection and for 1:50 and 1:100 sample dilutions. This phenomenon was correlated with increased antibody titres in the early post-infection phase. While prozone effects are often observed in serological agglutination assays for the diagnosis of animal brucellosis and human syphilis, they are not widely reported in leptospirosis MATs.
Resumo:
INTRODUCTION: Rivaroxaban (RXA) is licensed for prophylaxis of venous thromboembolism after major orthopaedic surgery of the lower limbs. Currently, no test to quantify RXA in plasma has been validated in an inter-laboratory setting. Our study had three aims: to assess i) the feasibility of RXA quantification with a commercial anti-FXa assay, ii) its accuracy and precision in an inter-laboratory setting, and iii) the influence of 10mg of RXA on routine coagulation tests. METHODS: The same chromogenic anti-FXa assay (Hyphen BioMed) was used in all participating laboratories. RXA calibrators and sets of blinded probes (aim ii.) were prepared in vitro by spiking normal plasma. The precise RXA content was assessed by high-pressure liquid chromatography-tandem mass spectrometry. For ex-vivo studies (aim iii), plasma samples from 20 healthy volunteers taken before and 2 - 3hours after ingestion of 10mg of RXA were analyzed by participating laboratories. RESULTS: RXA can be assayed chromogenically. Among the participating laboratories, the mean accuracy and the mean coefficient of variation for precision of RXA quantification were 7.0% and 8.8%, respectively. Mean RXA concentration was 114±43μg/L .RXA significantly altered prothrombin time, activated partial thromboplastin time, factor analysis for intrinsic and extrinsic factors. Determinations of thrombin time, fibrinogen, FXIII and D-Dimer levels were not affected. CONCLUSIONS: RXA plasma levels can be quantified accurately and precisely by a chromogenic anti-FXa assay on different coagulometers in different laboratories. Ingestion of 10mg RXA results in significant alterations of both PT- and aPTT-based coagulation assays.