948 resultados para parallel robots,cable driven,underactuated,calibration,sensitivity,accuracy


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The application of analytical procedures based on multivariate calibration models has been limited in several areas due to requirements of validation and certification of the model. Procedures for validation are presented based on the determination of figures of merit, such as precision (mean, repeatability, intermediate), accuracy, sensitivity, analytical sensitivity, selectivity, signal-to-noise ratio and confidence intervals for PLS models. An example is discussed of a model for polymorphic purity control of carbamazepine by NIR diffuse reflectance spectroscopy. The results show that multivariate calibration models can be validated to fulfill the requirements imposed by industry and standardization agencies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Biofilm communities are exposed to long periods of desiccation in temporary streams. We investigated how water flow intermittency affected the bacterial community structure colonizing three different streambed compartments in a Mediterranean stream. Massive parallel sequencing revealed different bacterial communities in biofilms from sand sediments and cobbles. Bacterial communities were similar (62% of shared operational taxonomic units) in the epipsammic and hyporheic biofilms, and more diverse than those in the epilithic biofilms. The non-flow phase caused a decrease of bacterial diversity in the biofilms, when communities included only bacterial taxa assumed to be adapted to water stress. The most sensitive bacterial communities to flow intermittency were in the epilithic, where the exposure to physical stress was the highest. In sand sediments a wide group of bacterial taxa was tolerant to desiccation. During non-flow the proliferation of opportunistic taxa in the superficial compartments evidenced the biological link with the terrestrial environment. Bacterial communities better tolerate rewetting than desiccation, since a major number of taxa tolerant to rewetting occurred in all biofilms. Overall, bacterial communities in sandy compartments showed higher resistance to flow intermittency than those in epilithic biofilms

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This thesis presents the calibration and comparison of two systems, a machine vision system that uses 3 channel RGB images and a line scanning spectral system. Calibration. is the process of checking and adjusting the accuracy of a measuring instrument by comparing it with standards. For the RGB system self-calibrating methods for finding various parameters of the imaging device were developed. Color calibration was done and the colors produced by the system were compared to the known colors values of the target. Software drivers for the Sony Robot were also developed and a mechanical part to connect a camera to the robot was also designed. For the line scanning spectral system, methods for the calibrating the alignment of the system and the measurement of the dimensions of the line scanned by the system were developed. Color calibration of the spectral system is also presented.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In the present work the aim was to prepare an automatic installation for studies of galvanomagnetic effects in solids and to test it by calibration measurements. As a result required automatic installation was created in this work and test measurements were performed. Created setup automatically provides measurements of the magnetoresistance of the Hall effect with an accuracy of ± 2 µV in the temperature range 2 – 300 K and steady magnetic fields up to 6 T. The test measurements of the glassy carbon samples showed that the setup is reliable, has high sensitivity and is easy to use. The results obtained in the research process are pioneer and will be separately analyzed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The maximum realizable power throughput of power electronic converters may be limited or constrained by technical or economical considerations. One solution to this problemis to connect several power converter units in parallel. The parallel connection can be used to increase the current carrying capacity of the overall system beyond the ratings of individual power converter units. Thus, it is possible to use several lower-power converter units, produced in large quantities, as building blocks to construct high-power converters in a modular manner. High-power converters realized by using parallel connection are needed for example in multimegawatt wind power generation systems. Parallel connection of power converter units is also required in emerging applications such as photovoltaic and fuel cell power conversion. The parallel operation of power converter units is not, however, problem free. This is because parallel-operating units are subject to overcurrent stresses, which are caused by unequal load current sharing or currents that flow between the units. Commonly, the term ’circulatingcurrent’ is used to describe both the unequal load current sharing and the currents flowing between the units. Circulating currents, again, are caused by component tolerances and asynchronous operation of the parallel units. Parallel-operating units are also subject to stresses caused by unequal thermal stress distribution. Both of these problemscan, nevertheless, be handled with a proper circulating current control. To design an effective circulating current control system, we need information about circulating current dynamics. The dynamics of the circulating currents can be investigated by developing appropriate mathematical models. In this dissertation, circulating current models aredeveloped for two different types of parallel two-level three-phase inverter configurations. Themodels, which are developed for an arbitrary number of parallel units, provide a framework for analyzing circulating current generation mechanisms and developing circulating current control systems. In addition to developing circulating current models, modulation of parallel inverters is considered. It is illustrated that depending on the parallel inverter configuration and the modulation method applied, common-mode circulating currents may be excited as a consequence of the differential-mode circulating current control. To prevent the common-mode circulating currents that are caused by the modulation, a dual modulator method is introduced. The dual modulator basically consists of two independently operating modulators, the outputs of which eventually constitute the switching commands of the inverter. The two independently operating modulators are referred to as primary and secondary modulators. In its intended usage, the same voltage vector is fed to the primary modulators of each parallel unit, and the inputs of the secondary modulators are obtained from the circulating current controllers. To ensure that voltage commands obtained from the circulating current controllers are realizable, it must be guaranteed that the inverter is not driven into saturation by the primary modulator. The inverter saturation can be prevented by limiting the inputs of the primary and secondary modulators. Because of this, also a limitation algorithm is proposed. The operation of both the proposed dual modulator and the limitation algorithm is verified experimentally.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this master’s thesis is to develop an algorithm to calculate the cable network for heat and power station CHGRES. This algorithm includes important aspect which has an influence on the cable network reliability. Moreover, according to developed algorithm, the optimal solution for modernization cable system from economical and technical point of view was obtained. The conditions of existing cable lines show that replacement is necessary. Otherwise, the fault situation would happen. In this case company would loss not only money but also its prestige. As a solution, XLPE single core cables are more profitable than other types of cable considered in this work. Moreover, it is presented the dependence of value of short circuit current on number of 10/110 kV transformers connected in parallel between main grid and considered 10 kV busbar and how it affects on final decision. Furthermore, the losses of company in power (capacity) market due to fault situation are presented. These losses are commensurable with investment to replace existing cable system.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The possibility of using thiocyanate to determine iron(II) and/or iron(III) in water-acetone mixture has been re-examined as part of a systematic and comparative study involving metallic complexes of pseudohalide ligands. Some parameters that affect the complete oxidation of the ferrous cations, their subsequent complexation and the system stability have been studied to optimize the experimental conditions. Our results show the viability and potentiality of this simply methodology as an alternative analytical procedure to determine iron cations with high sensitivity, precision and accuracy. Studies on the calibration, stability, precision, and effect of various different ions have been carried out by using absorbance values measured at 480 nm. The analytical curve for the total iron determination obeys Beer's law (r = 0.9993), showing a higher sensitivity (molar absorptivity of 2.10x10(4) L cm-1 mol-1) when compared with other traditional systems (ligands) or even with the "similar" azide ion [1.53x10(4) L cm-1 mol-1, for iron-III/azide complexes, in 70% (v/v) tetrahydrofuran/water, at 396 nm]. Under such optimized experimental conditions, it is possible to determine iron in the concentration range from 0.5 to 2 ppm (15-65% T for older equipments, quartz cells of 1.00 cm). Analytical applications have been tested for some different materials (iron ores), also including pharmaceutical products for anemia, and results were compared with atomic absorption determinations. Very good agreement was obtained with these two different techniques, showing the potential of the present experimental conditions for the total iron spectrophotometric determinations (errors < 5%). The possibility of iron speciation was made evident by using another specific and auxiliary method for iron(II) or (III).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Centrifugal pumps are widely used in industrial and municipal applications, and they are an important end-use application of electric energy. However, in many cases centrifugal pumps operate with a significantly lower energy efficiency than they actually could, which typically has an increasing effect on the pump energy consumption and the resulting energy costs. Typical reasons for this are the incorrect dimensioning of the pumping system components and inefficiency of the applied pump control method. Besides the increase in energy costs, an inefficient operation may increase the risk of a pump failure and thereby the maintenance costs. In the worst case, a pump failure may lead to a process shutdown accruing additional costs. Nowadays, centrifugal pumps are often controlled by adjusting their rotational speed, which affects the resulting flow rate and output pressure of the pumped fluid. Typically, the speed control is realised with a frequency converter that allows the control of the rotational speed of an induction motor. Since a frequency converter can estimate the motor rotational speed and shaft torque without external measurement sensors on the motor shaft, it also allows the development and use of sensorless methods for the estimation of the pump operation. Still today, the monitoring of pump operation is based on additional measurements and visual check-ups, which may not be applicable to determine the energy efficiency of the pump operation. This doctoral thesis concentrates on the methods that allow the use of a frequency converter as a monitoring and analysis device for a centrifugal pump. Firstly, the determination of energy-efficiency- and reliability-based limits for the recommendable operating region of a variable-speed-driven centrifugal pump is discussed with a case study for the laboratory pumping system. Then, three model-based estimation methods for the pump operating location are studied, and their accuracy is determined by laboratory tests. In addition, a novel method to detect the occurrence of cavitation or flow recirculation in a centrifugal pump by a frequency converter is introduced. Its sensitivity compared with known cavitation detection methods is evaluated, and its applicability is verified by laboratory measurements for three different pumps and by using two different frequency converters. The main focus of this thesis is on the radial flow end-suction centrifugal pumps, but the studied methods can also be feasible with mixed and axial flow centrifugal pumps, if allowed by their characteristics.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Nykyisessä valmistusteollisuudessa erilaisten robottien ja automatisoitujen tuotantovaiheiden rooli on erittäin merkittävä. Tarkasti suunnitellut liikkeet ja toimintavaiheet voidaan nykyisillä järjestelmillä ajoittaa tarkasti toisiinsa nähden, jolloin erilaisten virhetilanteidenkin sattuessa järjestelmä pystyy toimimaan tilanteen edellyttämällä tavalla. Automatisoinnin etuna on myös tuotannon muokkaaminen erilaisten tuotteiden valmistamiseen pienillä muutoksilla, jolloin tuotantokustannukset pysyvät matalina myös pienten valmistuserien tapauksissa. Usean akselin laitteissa eli niin sanotuissa moniakselikäytöissä laitteen toimintatarkkuus riippuu jokaisen liikeakselin tarkkuudesta. Liikkeenohjauksessa on perinteisesti ollut käytössä myötäkytketty paikkakaskadi, jonka virityksessä otetaan huomioon akselilla olevat erilaiset dynaamiset tilat ja käytettävät referenssit. Monissa nykyisissä hajautetuissa järjestelmissä eli moniakselikäytöissä, joissa jokaiselle akselille on oma ohjauslaite, ei yksittäisen akselin paikkavirhettä huomioida muiden akseleiden ohjauksessa. Työssä tutkitaan erilaisia moniakselijärjestelmien ohjausmenetelmiä ja myötäkytketyn paikkakaskadin toimintaa moniakselikäytössä pyritään parantamaan tuomalla paikkasäätimen rinnalle toinen säädin, jonka tulona on akseleiden välinen paikkaero.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The present study shows the development, simulation and actual implementation of a closed-loop controller based on fuzzy logic that is able to regulate and standardize the mass flow of a helical fertilizer applicator. The control algorithm was developed using MATLAB's Fuzzy Logic Toolbox. Both open and closed-loop simulations of the controller were performed in MATLAB's Simulink environment. The instantaneous deviation of the mass flow from the set point (SP), its derivative, the equipment´s translation velocity and acceleration were all used as input signals for the controller, whereas the voltage of the applicator's DC electric motor (DCEM) was driven by the controller as output signal. Calibration and validation of the rules and membership functions of the fuzzy logic were accomplished in the computer simulation phase, taking into account the system's response to SP changes. The mass flow variation coefficient, measured in experimental tests, ranged from 6.32 to 13.18%. The steady state error fell between -0.72 and 0.13g s-1 and the recorded average rise time of the system was 0.38 s. The implemented controller was able to both damp the oscillations in mass flow that are characteristic of helical fertilizer applicators, and to effectively respond to SP variations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: to evaluate the accuracy of frozen section histopathology from fragments of tissue obtained by percutaneous core needle biopsy of palpable tumors in the diagnosis of breast cancer. METHODS: a cohort study was performed on 57 patients with palpable tumors and suspected breast cancer undergoing percutaneous thick needle core biopsy. The fragments were analyzed by the same pathologist. RESULTS: frozen section diagnosed 16 benign cases (28.6%) and 40 malignant (71.4%), whereas paraffin showed that 15 were benign (26.8%) and 41 malignant (73.2%). Histopathological examinations were concordant in 55 cases and there was one false-negative (6.2%). Statistics rates were: negative predictive value of 93.8%, positive predictive value of 100%, no false-positive (0%), one false negative (6.2%), specificity of 100%, sensitivity of 97 6%; observed agreement = 98.2%; expected agreement = 59.9%, Kappa = 0.955 [ 95% CI = 0.925-0.974, p < 0.01 ]. CONCLUSIONS: frozen section histopathological findings showed excellent correlation with the findings by the technique in paraffin in the fragments of palpable breast tumors obtained by thick needle percutaneous core biopsy (98.2% accuracy). Therefore, in these patients, it was possible to anticipate the diagnosis, staging and the breast cancer treatment planning.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: To evaluate the accuracy of sonographic endometrial thickness and hysteroscopic characteristics in predicting malignancy in postmenopausal women undergoing surgical resection of endometrial polyps. METHODS: Five hundred twenty-one (521) postmenopausal women undergoing hysteroscopic resection of endometrial polyps between January 1998 and December 2008 were studied. For each value of sonographic endometrial thickness and polyp size on hysteroscopy, the sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were calculated in relation to the histologic diagnosis of malignancy. The best values of sensitivity and specificity for the diagnosis of malignancy were determined by the Receiver Operating Characteristic (ROC) curve. RESULTS: Histologic diagnosis identified the presence of premalignancy or malignancy in 4.1% of cases. Sonographic measurement revealed a greater endometrial thickness in cases of malignant polyps when compared to benign and premalignant polyps. On surgical hysteroscopy, malignant endometrial polyps were also larger. An endometrial thickness of 13 mm showed a sensitivity of 69.6%, specificity of 68.5%, PPV of 9.3%, and NPV of 98% in predicting malignancy in endometrial polyps. Polyp measurement by hysteroscopy showed that for polyps 30 mm in size, the sensitivity was 47.8%, specificity was 66.1%, PPV was 6.1%, and NPV was 96.5% for predicting cancer. CONCLUSIONS: Sonographic endometrial thickness showed a higher level of accuracy than hysteroscopic measurement in predicting malignancy in endometrial polyps. Despite this, both techniques showed low accuracy for predicting malignancy in endometrial polyps in postmenopausal women. In suspected cases, histologic evaluation is necessary to exclude malignancy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Transportation of fluids is one of the most common and energy intensive processes in the industrial and HVAC sectors. Pumping systems are frequently subject to engineering malpractice when dimensioned, which can lead to poor operational efficiency. Moreover, pump monitoring requires dedicated measuring equipment, which imply costly investments. Inefficient pump operation and improper maintenance can increase energy costs substantially and even lead to pump failure. A centrifugal pump is commonly driven by an induction motor. Driving the induction motor with a frequency converter can diminish energy consumption in pump drives and provide better control of a process. In addition, induction machine signals can also be estimated by modern frequency converters, dispensing with the use of sensors. If the estimates are accurate enough, a pump can be modelled and integrated into the frequency converter control scheme. This can open the possibility of joint motor and pump monitoring and diagnostics, thereby allowing the detection of reliability-reducing operating states that can lead to additional maintenance costs. The goal of this work is to study the accuracy of rotational speed, torque and shaft power estimates calculated by a frequency converter. Laboratory tests were performed in order to observe estimate behaviour in both steady-state and transient operation. An induction machine driven by a vector-controlled frequency converter, coupled with another induction machine acting as load was used in the tests. The estimated quantities were obtained through the frequency converter’s Trend Recorder software. A high-precision, HBM T12 torque-speed transducer was used to measure the actual values of the aforementioned variables. The effect of the flux optimization energy saving feature on the estimate quality was also studied. A processing function was developed in MATLAB for comparison of the obtained data. The obtained results confirm the suitability of this particular converter to provide accurate enough estimates for pumping applications.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Kuppikartongin yksi tärkeimmistä ominaisuuksista on reunaimeytymän vastustuskyky, joka tulee olla riittävällä tasolla laadun takaamiseksi. Koska yksinkertainen juomakuppi on bulkki¬tuote, ei sen raakareunaa kannata taloudellisuuden vuoksi suojata tätä varten kehitellyillä menetelmillä vaan itse kartongin tulee vastustaa nesteitä riittävässä määrin. Tämän diplomityön tarkoituksena oli selvittää hydrofobointiin käytettävän massaliiman (hartsi) sekä pintaliiman joukkoon annosteltavan lisäaineen välinen optimaalinen suhde parhaan vastustuskyvyn saavuttamiseksi. Lisäksi selvitettiin joidenkin liimapuristimen ajo-olosuhteiden vaikutusta pintaliiman pick-upiin sekä koneen pH-tason oikeellisuus. Jauhatuksen vaikutusta tutkittiin lähinnä historiatietojen avulla. Tutkimus koostui viidestä tehdasmittakaavaisesta koeajosta, joiden avulla selvitettiin muuttujien vaikutus sisäisellä reunaimeytymän määritysmenetelmällä sekä määrittä¬mällä koepisteistä kulloinkin mielenkiinnon kohteena olleet kemikaalipitoisuudet. Viimeisen koeajon koepisteet jalostettiin lisäksi valmiiksi kupeiksi. Käytetty reunaimeytymän määritysmenetelmä osoittautui virhealttiiksi eivätkä raakakartongista tehtyjen määritysten tulokset korreloineet kovinkaan voimakkaasti PE-päällystettyjen näytteiden kanssa. Menetelmän kehitystä on viety eteenpäin tämän työn rinnalla ja työ jatkuu edelleen. Lisäksi kartongin hartsipitoisuusmääritysten tuloksista paljastui ristiriitaisuuksia, joiden vuoksi menetelmää uusittiin voimakkaasti. Reunaimeytymän vastustuksen riittävyydeksi koneella käytettävien massaliima-annosten tulee olla vähintään valitulla nollatasolla kaikissa kerroksissa ja pintaliiman lisäaine tulee pitää käytössä. Mikäli lisäaine jätetään pois käytöstä, tulee massaliima-annokset olla hyvin korkeita, eikä tämäkään takaa täysin reunaimeytymätöntä lopputuotetta. Lisäaineen ollessa käytössä ei suuremmalla massaliima-annoksella ole puolestaan merkittävää vaikutusta. Konetta ajetaan nykyisin hyvin alhaisella pH-tasolla, mutta tason nostaminen aiheuttaa selvän liimauksen heikkenemisen. Liimapuristimelle tulevan radan kosteudella ja pintaliiman kuiva-aineella ei näyttäisi olevan vaikutusta kartongin reunaimeytymän vastustuskykyyn. Myöskään taustakerroksen koivun jauhatusasteella ei ole merkitystä alueella, jolla koneella operoidaan. CTMP-massan jauhatuksen tulee sen sijaan olla riittävä, jotta keskikerrokseen ei synny yksittäisiä, pitkiä imeytymiä.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper describes an electronic transducer for multiphase flow measurement. Its high sensitivity, good signal to noise ratio and accuracy are achieved through an electrical impedance sensor with a special guard technique. The transducer consists of a wide bandwidth and high slew rate differentiator where the lead inductance and stray capacitance effects are compensated. The sensor edge effect is eliminated by using a guard electrode based on the virtual ground potential of the operational amplifier. A theoretical modeling and a calibration method are also presented. The results obtained seem to confirm the validity of the proposed technique.