981 resultados para label printing


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Analysis of binding recognition and conformation of biomolecules is of paramount important in understanding of their vital functions in complex biological systems. By enabling sub-wavelength light localization and strong local field enhancement, plasmonic biosensors have become dominant tools used for such analysis owing to their label-free and real-time attributes1,2. However, the plasmonic biosensors are not well-suited to provide information regarding conformation or chemical fingerprint of biomolecules. Here, we show that plasmonic metamaterials, consisting of periodic arrays of artificial split-ring resonators (SRRs)3, can enable capabilities of both sensing and fingerprinting of biomolecules. We demonstrate that by engineering geometry of individual SRRs, localized surface plasmon resonance (LSPR) frequency of the metamaterials could be tuned to visible-near infrared regimes (Vis-NIR) such that they possess high local field enhancement for surface-enhanced Raman scattering spectroscopy (SERS). This will provide the basis for the development of a dual mode label-free conformational-resolving and quantitative detection platform. We present here the ability of each sensing mode to independently detect binding adsorption and to identify different conformational states of Guanine (G)-rich DNA monolayers in different environment milieu. Also shown is the use of the nanosensor for fingerprinting and detection of Arginine-Glycine-Glycine (RGG) peptide binding to the G-quadruplex aptamer. The dual-mode nanosensor will significantly contribute to unraveling the complexes of the conformational dynamics of biomolecules as well as to improving specificity of biodetection assays that the conventional, population-averaged plasmonic biosensors cannot achieve.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Analysis of molecular interaction and conformational dynamics of biomolecules is of paramount importance in understanding of their vital functions in complex biological systems, disease detection, and new drug development. Plasmonic biosensors based upon surface plasmon resonance and localized surface plasmon resonance have become the predominant workhorse for detecting accumulated biomass caused by molecular binding events. However, unlike surface-enhanced Raman spectroscopy (SERS), the plasmonic biosensors indeed are not suitable tools to interrogate vibrational signatures of conformational transitions required for biomolecules to interact. Here, we show that highly tunable plasmonic metamaterials can offer two transducing channels for parallel acquisition of optical transmission and sensitive SERS spectra at the biointerface, simultaneously probing the conformational states and binding affinity of biomolecules, e.g. G-quadruplexes, in different environments. We further demonstrate the use of the metamaterials for fingerprinting and detection of arginine-glycine-glycine domain of nucleolin, a cancer biomarker which specifically binds to a G-quadruplex, with the picomolar sensitivity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Automatically determining and assigning shared and meaningful text labels to data extracted from an e-Commerce web page is a challenging problem. An e-Commerce web page can display a list of data records, each of which can contain a combination of data items (e.g. product name and price) and explicit labels, which describe some of these data items. Recent advances in extraction techniques have made it much easier to precisely extract individual data items and labels from a web page, however, there are two open problems: 1. assigning an explicit label to a data item, and 2. determining labels for the remaining data items. Furthermore, improvements in the availability and coverage of vocabularies, especially in the context of e-Commerce web sites, means that we now have access to a bank of relevant, meaningful and shared labels which can be assigned to extracted data items. However, there is a need for a technique which will take as input a set of extracted data items and assign automatically to them the most relevant and meaningful labels from a shared vocabulary. We observe that the Information Extraction (IE) community has developed a great number of techniques which solve problems similar to our own. In this work-in-progress paper we propose our intention to theoretically and experimentally evaluate different IE techniques to ascertain which is most suitable to solve this problem.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this study, calcium phosphate (CaP) powders were blended with a three-dimensional printing (3DP) calcium sulfate (CaSO4)-based powder and the resulting composite powders were printed with a water-based binder using the 3DP technology. Application of a water-based binder ensured the manufacture of CaP:CaSO4 constructs on a reliable and repeatable basis, without long term damage of the printhead. Printability of CaP:CaSO4 powders was quantitatively assessed by investigating the key 3DP process parameters, i.e. in-process powder bed packing, drop penetration behavior and the quality of printed solid constructs. Effects of particle size, CaP:CaSO4 ratio and CaP powder type on the 3DP process were considered. The drop penetration technique was used to reliably identify powder formulations that could be potentially used for the application of tissue engineered bone scaffolds using the 3DP technique. Significant improvements (p < 0.05) in the 3DP process parameters were found for CaP (30-110 μm):CaSO4 powders compared to CaP (< 20 μm):CaSO4 powders. Higher compressive strength was obtained for the powders with the higher CaP:CaSO4 ratio. Hydroxyapatite (HA):CaSO4 powders showed better results than beta-tricalcium phosphate (β-TCP):CaSO4 powders. Solid and porous constructs were manufactured using the 3DP technique from the optimized CaP:CaSO4 powder formulations. High-quality printed constructs were manufactured, which exhibited appropriate green compressive strength and a high level of printing accuracy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study investigated the feasibility of manufacturing hydroxyapatite (HA)-based scaffolds using 3D printing technology by incorporating different binding additives, such as maltodextrin and polyvinyl alcohol (PVOH), into the powder formulation. Different grades of PVOH were evaluated in terms of their impact on the printing quality. Results showed that scaffolds with high architectural accuracy in terms of the design and excellent green compressive strength were obtained when the PVOH (high viscosity) was used as the binding additive for HA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Inkjet printing is proposed as a means to create the resistively loaded elements of a frequency selective surface (FSS) which suppresses radar backscatter when placed above a metal ground plane. Spectral transmission and reflection measurements from 9 to 18 GHz show that the dot density of the printed features and the volume ratio of an aqueous vehicle and nano-silver (Ag) ink mixture can be selected to obtain surface resistances in the range 1.2-200 Ω/sq.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Anemia is considered a negative prognostic risk factor for survival in patients with myelofibrosis. Most patients with myelofibrosis are anemic, and 35-54 % present with anemia at diagnosis. Ruxolitinib, a potent inhibitor of Janus kinase (JAK) 1 and JAK2, was associated with an overall survival benefit and improvements in splenomegaly and patient-reported outcomes in patients with myelofibrosis in the two phase 3 COMFORT studies. Consistent with the ruxolitinib mechanism of action, anemia was a frequently reported adverse event. In clinical practice, anemia is sometimes managed with erythropoiesis-stimulating agents (ESAs). This post hoc analysis evaluated the safety and efficacy of concomitant ruxolitinib and ESA administration in patients enrolled in COMFORT-II, an open-label, phase 3 study comparing the efficacy and safety of ruxolitinib with best available therapy for treatment of myelofibrosis. Patients were randomized (2:1) to receive ruxolitinib 15 or 20 mg twice daily or best available therapy. Spleen volume was assessed by magnetic resonance imaging or computed tomography scan.

RESULTS: Thirteen of 146 ruxolitinib-treated patients had concomitant ESA administration (+ESA). The median exposure to ruxolitinib was 114 weeks in the +ESA group and 111 weeks in the overall ruxolitinib arm; the median ruxolitinib dose intensity was 33 mg/day for each group. Six weeks before the first ESA administration, 10 of the 13 patients had grade 3/4 hemoglobin abnormalities. These had improved to grade 2 in 7 of the 13 patients by 6 weeks after the first ESA administration. The rate of packed red blood cell transfusions per month within 12 weeks before and after first ESA administration remained the same in 1 patient, decreased in 2 patients, and increased in 3 patients; 7 patients remained transfusion independent. Reductions in splenomegaly were observed in 69 % of evaluable patients (9/13) following first ESA administration.

CONCLUSIONS: Concomitant use of an ESA with ruxolitinib was well tolerated and did not affect the efficacy of ruxolitinib. Further investigations evaluating the effects of ESAs to alleviate anemia in ruxolitinib-treated patients are warranted (ClinicalTrials.gov identifier, NCT00934544; July 6, 2009).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Evidence that persistent environmental pollutants may target the male reproductive system is increasing. The male reproductive system is regulated by secretion of testosterone by testicular Leydig cells, and perturbation of Leydig cell function may have ultimate consequences. 3-Methylsulfonyl-DDE (3-MeSO2-DDE) is a potent adrenal toxicants formed from the persistent insecticide DDT. Although studies have revealed the endocrine disruptive effect of 3-MeSO2-DDE, the underlying mechanisms at cellular level in steroidogenic Leydig cells remains to be established. The current study addresses the effect of 3-MeSO2-DDE on viability, hormone production and proteome response of primary neonatal porcine Leydig cells. The AlamarBlue™ assay was used to evaluate cell viability. Solid phase radioimmunoassay was used to measure concentration of hormones produced by both unstimulated and Luteinizing hormone (LH)-stimulated Leydig cells following 48h exposure. Protein samples from Leydig cells exposed to a non-cytotoxic concentration of 3-MeSO2-DDE (10μM) were subjected to nano-LC-MS/MS and analyzed on a Q Exactive mass spectrometer and quantified using label-free quantitative algorithm. Gene Ontology (GO) and Ingenuity Pathway Analysis (IPA) were carried out for functional annotation and identification of protein interaction networks. 3-MeSO2-DDE regulated Leydig cell steroidogenesis differentially depending on cell culture condition. Whereas its effect on testosterone secretion at basal condition was stimulatory, the effect on LH-stimulated cells was inhibitory. From triplicate experiments, a total of 6804 proteins were identified in which the abundance of 86 proteins in unstimulated Leydig cells and 145 proteins in LH-stimulated Leydig cells was found to be significantly regulated in response to 3-MeSO2-DDE exposure. These proteins not only are the first reported in relation to 3-MeSO2-DDE exposure, but also display small number of proteins shared between culture conditions, suggesting the action of 3-MeSO2-DDE on several targeted pathways, including mitochondrial dysfunction, oxidative phosphorylation, EIF2-signaling, and glutathione-mediated detoxification. Further identification and characterization of these proteins and pathways may build our understanding to the molecular basis of 3-MeSO2-DDE induced endocrine disruption in Leydig cells.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work proposes a novel approach for a suitable orientation of antibodies (Ab) on an immunosensing platform, applied here to the determination of 8-hydroxy-2′-deoxyguanosine (8OHdG), a biomarker of oxidative stress that has been associated to chronic diseases, such as cancer. The anti-8OHdG was bound to an amine modified gold support through its Fc region after activation of its carboxylic functions. Non-oriented approaches of Ab binding to the platform were tested in parallel, in order to show that the presented methodology favored Ab/Ag affinity and immunodetection of the antigen. The immunosensor design was evaluated by quartz-crystal microbalance with dissipation, atomic force microscopy, electrochemical impedance spectroscopy (EIS) and square-wave voltammetry. EIS was also a suitable technique to follow the analytical behavior of the device against 8OHdG. The affinity binding between 8OHdG and the antibody immobilized in the gold modified platform increased the charge transfer resistance across the electrochemical set-up. The observed behavior was linear from 0.02 to 7.0 ng/mL of 8OHdG concentrations. The interference from glucose, urea and creatinine was found negligible. An attempt of application to synthetic samples was also successfully conducted. Overall, the presented approach enabled the production of suitably oriented Abs over a gold platform by means of a much simpler process than other oriented-Ab binding approaches described in the literature, as far as we know, and was successful in terms of analytical features and sample application.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new immunosensor is presented for human chorionic gonadotropin (hCG), made by electrodepositing chitosan/gold-nanoparticles over graphene screen-printed electrode (SPE). The antibody was covalently bound to CS via its Fc-terminal. The assembly was controlled by electrochemical Impedance Spectroscopy (EIS) and followed by Fourier Transformed Infrared (FTIR). The hCG-immunosensor displayed linear response against the logarithm-hCG concentration for 0.1–25 ng/mL with limit of detection of 0.016 ng/mL. High selectivity was observed in blank urine and successful detection of hCG was also achieved in spiked samples of real urine from pregnant woman. The immunosensor showed good detection capability, simplicity of fabrication, low-cost, high sensitivity and selectivity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Human chorionic gonadotropin (hCG) is a key diagnostic marker of pregnancy and an important biomarker for cancers in the prostate, ovaries and bladder and therefore of great importance in diagnosis. For this purpose, a new immunosensor of screen-printed electrodes (SPEs) is presented here. The device was fabricated by introducing a polyaniline (PANI) conductive layer, via in situ electropolymerization of aniline, onto a screen-printed graphene support. The PANI-coated graphene acts as the working electrode of a three terminal electrochemical sensor. The working electrode is functionalised with anti-hCG, by means of a simple process that enabled oriented antibody binding to the PANI layer. The antibody was attached to PANI following activation of the –COOH group at the Fc terminal. Functionalisation of the electrode was analysed and optimized using Electrochemical Impedance Spectroscopy (EIS). Chemical modification of the surface was characterised using Fourier transform infrared, and Raman spectroscopy with confocal microscopy. The graphene–SPE–PANI devices displayed linear responses to hCG in EIS assays from 0.001 to 50 ng mL−1 in real urine, with a detection limit of 0.286 pg mL−1. High selectivity was observed with respect to the presence of the constituent components of urine (urea, creatinine, magnesium chloride, calcium chloride, sodium dihydrogen phosphate, ammonium chloride, potassium sulphate and sodium chloride) at their normal levels, with a negligible sensor response to these chemicals. Successful detection of hCG was also achieved in spiked samples of real urine from a pregnant woman. The immunosensor developed is a promising tool for point-of-care detection of hCG, due to its excellent detection capability, simplicity of fabrication, low-cost, high sensitivity and selectivity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Increased levels of plasma oxLDL, which is the oxidized fraction of Low Density Lipoprotein (LDL), are associated with atherosclerosis, an inflammatory disease, and the subsequent development of severe cardiovascular diseases that are today a major cause of death in modern countries. It is therefore important to find a reliable and fast assay to determine oxLDL in serum. A new immunosensor employing three monoclonal antibodies (mAbs) against oxLDL is proposed in this work as a quick and effective way to monitor oxLDL. The oxLDL was first employed to produce anti-oxLDL monoclonal antibodies by hybridoma cells that were previously obtained. The immunosensor was set-up by selfassembling cysteamine (Cyst) on a gold (Au) layer (4 mm diameter) of a disposable screen-printed electrode. Three mAbs were allowed to react with N-hydroxysuccinimide (NHS) and ethyl(dimethylaminopropyl)carbodiimide (EDAC), and subsequently incubated in the Au/Cys. Albumin from bovine serum (BSA) was immobilized further to ensure that other molecules apart from oxLDL could not bind to the electrode surface. All steps were followed by various characterization techniques such as electrochemical impedance spectroscopy (EIS) and square wave voltammetry (SWV). The analytical operation of the immunosensor was obtained by incubating the sensing layer of the device in oxLDL for 15 minutes, prior to EIS and SWV. This was done by using standard oxLDL solutions prepared in foetal calf serum, in order to simulate patient's plasma with circulating oxLDL. A sensitive response was observed from 0.5 to 18.0 mg mL 1 . The device was successfully applied to determine the oxLDL fraction in real serum, without prior dilution or necessary chemical treatment. The use of multiple monoclonal antibodies on a biosensing platform seemed to be a successful approach to produce a specific response towards a complex multi-analyte target, correlating well with the level of oxLDL within atherosclerosis disease, in a simple, fast and cheap way.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A label-free DNA aptamer-based impedance biosensor for the detection of E. coli outer membrane proteins (OMPs) was developed. Two single stranded DNA sequences were tested as recognition elements and compared. The aptamer capture probes were immobilized, with and without 6-mercapto-1-hexanol (MCH) on a gold electrode. Each step of the modification process was characterized by Faradaic impedance spectroscopy (FIS). A linear relationship between the electron-transfer resistance (Ret) and E. coli OMPs concentration was demonstrated in a dynamic detection range of 1 × 10−7–2 × 10−6 M. Moreover, the aptasensor showed selectivity despite the presence of other possible water contaminates and could be regenerated under low pH condition. The developed biosensor shows great potential to be incorporated in a biochip and used for in situ detection of E. coli OMPs in water samples.