894 resultados para heavy metal species


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The research concerned the assessment of the pathways utilized by heavy metal pollutants in urban stormwater runoff. A separately sewered urban residential catchment of approximately 107 hectares in Chelmsley Wood, north-east Birmingham was the subject of the field investigation. The catchment area, almost entirely residential, had no immediate industrial heavy metal input, however, industry was situated to the north of the catchment. The perimeter of the catchment was bounded by the M6 motorway on the northern and eastern sides and was believed to contribute to aerial deposition. Metal inputs to the ground surface were assumed to be confined to normal suburban activities, namely, aerial deposition, vehicular activity and anthropological activities. A programme of field work was undertaken over a 12 month period, from July 1983 to July 1984. Monthly deposition rates were monitored using a network of deposit cannisters and roadside sediment and soil samples were taken. Stormwater samples were obtained for 19 separate events. All samples were analysed for iron, lead, zinc, copper, chromium, nickel and cadmium content. Rainfall was recorded on site with additional meteorological data obtained from local Meteorological Offices. Use was made of a simple conceptual model designed for the catchment to substantiate hypotheses derived from site investigations and literature, to investigate the pathways utilized for the transportation of heavy metals throughout the catchment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The research examines the deposition of airborne particles which contain heavy metals and investigates the methods that can be used to identify their sources. The research focuses on lead and cadmium because these two metals are of growing public and scientific concern on environmental health grounds. The research consists of three distinct parts. The first is the development and evaluation of a new deposition measurement instrument - the deposit cannister - designed specifically for large-scale surveys in urban areas. The deposit cannister is specifically designed to be cheap, robust, and versatile and therefore to permit comprehensive high-density urban surveys. The siting policy reduces contamination from locally resuspended surface-dust. The second part of the research has involved detailed surveys of heavy metal deposition in Walsall, West Midlands, using the new high-density measurement method. The main survey, conducted over a six-week period in November - December 1982, provided 30-day samples of deposition at 250 different sites. The results have been used to examine the magnitude and spatial variability of deposition rates in the case-study area, and to evaluate the performance of the measurement method. The third part of the research has been to conduct a 'source-identification' exercise. The methods used have been Receptor Models - Factor Analysis and Cluster Analysis - and a predictive source-based deposition model. The results indicate that there are six main source processes contributing to deposition of metals in the Walsall area: coal combustion, vehicle emissions, ironfounding, copper refining and two general industrial/urban processes. |A source-based deposition model has been calibrated using facctorscores for one source factor as the dependent variable, rather than metal deposition rates, thus avoiding problems traditionally encountered in calibrating models in complex multi-source areas. Empirical evidence supports the hypothesised associatlon of this factor with emissions of metals from the ironfoundry industry.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Changes in concentration levels and speciation of heavy metals during sedimentation on example of a typical semi-closed bay, where bottom sediments have formed due to river run-off, are under consideration. It is shown that due to desorption of mobile manganese, zinc and copper entered the bay with river suspended matter, their total contents in bottom sediments decrease and percentages of lithogenic forms increase. Contents and speciation of iron in bottom sediments are determined by its participation in coagulation of river colloids in the mixing zone and by mechanical differentiation of sedimentary material.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Acknowledgements We thank B. Lahner, E. Yakubova and S. Rikiishi for ICP-MS analysis, N. Komiyama, Iowa State University Plant Transformation Facility and Prashant Hosmani for generation of transgenic rice, K. Wang for providing pTF101.1 vector and N. Verbruggen for providing pYES2 and pYEC2/CT-GFP vectors. We also thank Rice T-DNA Insertion Sequence Database center for providing the T-DNA insertion line and X. Wang, T. Zheng and Z. Li for accessing 3 K rice genome sequence, and Graeme Paton for helpful discussions on Cu bioavailability in water-logged soils. This research was supported by a Grant-in-Aid for Specially promoted Research (JSPS KAKENHI Grant Number 16H06296 to J.F.M), and the US National Science Foundation, Plant Genome Research Program (Grant #IOS 0701119 to D.E.S., M.L.G. and S.R.M.P.).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The authors acknowledge the financial support the Scottish Government’s Rural and Environmental Sciences and Analytical Services (RESAS) in order to complete some of the soil and pore water sample analysis as well as the Czech Ministry of Education, Youth and Sports (COST CZ LD13068), the Czech Science Foundation (GAČR 14-02183P) and EU COST actionFP1407 (‘ModWoodLife’) short term scientific mission grant in order to complete the column leaching test.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A new procedure was developed in this study, based on a system equipped with a cellulose membrane and a tetraethylenepentamine hexaacetate chelator (MD-TEPHA) for in situ characterization of the lability of metal species in aquatic systems. To this end, the DM-TEPHA system was prepared by adding TEPHA chelator to cellulose bags pre-purified with 1.0 mol L-1 of HCl and NaOH solutions. After the MD-TEPHA system was sealed, it was examined in the laboratory to evaluate the influence of complexation time (0-24 h), pH (3.0, 4.0, 5.0, 6.0 and 7.0), metal ions (Cu, Cd, Fe, Mn and Ni) and concentration of organic matter (15, 30 and 60 mg L-1) on the relative lability of metal species by TEPHA chelator. The results showed that Fe and Cu metals were complexed more slowly by TEPHA chelator in the MD-TEPHA system than were Cd, Ni and Mn in all pH used. It was also found that the pH strongly influences the process of metal complexation by the MD-TEPHA system. At all the pH levels, Cd, Mn and Ni showed greater complexation with TEPHA chelator (recovery of about 95-75%) than did Cu and Fe metals. Time also affects the lability of metal species complexed by aquatic humic substances (AHS); while Cd, Ni and Mn showed a faster kinetics, reaching equilibrium after about 100 min, and Cu and Fe approached equilibrium after 400 min. Increasing the AHS concentration decreases the lability of metal species by shifting the equilibrium to AHS-metal complexes. Our results indicate that the system under study offers an interesting alternative that can be applied to in situ experiments for differentiation of labile and inert metal species in aquatic systems. (c) 2006 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The present study deals with a new analytical procedure based on a cellulose diffusion membrane and immobilised tetraethylene-pentamine-hexaacetate chelator (DM-TEPHA) for an in situ differentiation of labile and inert metal species in aquatic systems. The DM-TEPHA system was prepared by placing TEPHA chelator in pre-purified cellulose bags and in situ applied immersing the system in two Brazilian rivers to study the relative lability of metal species (Cu, Pb, Fe, Mn and Ni) as a function of the time and the quantity of exchanger, respectively. The procedure is simple and enables a new perspective for understanding the complexation, transport, stability and lability of metal species in aquatic systems rich in organic matter.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The need for solutions to minimize the negative environmental impacts of anthropogenic activities Fhas increased. Sewage sludge is composed of predominantly organic matter and can be used to improve soil characteristics, such as fertility. Therefore, its application in agriculture is an adequate alternative for its final disposal. However, there is a lack of information on its long-term effects on soil changes in tropical areas. Thus, the objectives of this study were to determine (i) the effect of sewage sludge application on heavy metal build-up in soil and maize grains and leaves, and (ii) the effects of soil amendment with sewage sludge on the chemical properties of a Brazilian oxisol. Besides the increasing levels of Zn, Cu, Ni, and Cr, amending soil with sewage sludge also alters the distribution of these metals by increasing the mobile Phases, which correlated significantly with the increase in metal extraction with two single extractants, Mehlich 1 and DTPA (Diethylene triamine pentaacetic acid). The levels of Fe, Mn, Zn, and Cu in maize grains and leaves increased with the type and rate of sewage sludge application. Nevertheless, metal build-up in soil and plants was within the allowed limits. Significant differences were also found in soil characteristics like humic fractionation with the applied sewage doses. The data obtained does not indicate any expressive drawbacks in the use of sewage sludge as a soil amendment, as the heavy metal concentrations observed are unlikely to cause any environmental or health problems, even overestimated loadings, and are in accordance with the Brazilian regulations on farming land biosolid disposal.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Zero valent iron nanoparticles (nZVI) represent a promising agent for environmental remediation. Nevertheless, their application presents some limitations regarding their rapid oxidation and aggregation in the media. The aim of this study was to determine the effect that nZVI aging has in heavy metal remediation in water. Contaminants studied were Zn, Cd, Ni, Cu and Cr, which are typical elements found in ground and wastewater. Results show a high contaminant removal capacity by the nZVI in the first 2 h of reaction. Nevertheless, for longer reaction times, some of the metal ions that had already been adsorbed in the nZVI were delivered to the water. Cd and Ni show the maximum delivery percentages (65 and 27% respectively after 21 days of contact time). The starting delivery time was shortened when applying lower nZVI amounts. No re-dissolution of Cr was observed in any circumstance because it was the only element incorporated into the nanoparticles core, as TEM images showed. Contaminant release from nZVI is probably due to nanoparticles oxidation caused by aging, which produced a pH decrease and nZVI surface crystallization.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Übergangsmetallen wie Nickel und Cobalt kommt meist eine große Bedeutung als Cofaktor in Enzymen oder Metallkomplexen im Metabolismus von Lebewesen zu. Da eine sehr geringe Konzentration dieser Übergangsmetalle in einer Zelle für deren Funktionalität ausreicht, ist eine konstante Konzentration der Spurenelemente in einer Zelle angestrebt. Durch meist anthropogene Einflüsse sind Pflanzen und Menschen zunehmend hohen Konzentrationen von Übergangsmetallen ausgesetzt, die in Abhängigkeit von ihrer Spezies, der Konzentration und der Lokalisation unterschiedliche Toxizitäten aufweisen können. Die Speziation von Metallen wurde bisher mittels gängiger Analyseverfahren, wie der ICP-MS und ähnlicher Verfahren, anhand von bulk-Material durchgeführt. Durch die Entwicklung von optischen Sensoren für Metallionen war es möglich, diese Metalle auch in lebenden Zellen mittels Fluoreszenzmikroskopie zu lokalisieren. Ke und Kollegen (2006, 2007) nutzten einen solchen optischen Sensor - Newport Green DCF, um die Aufnahme von Nickel in humane A543 Lungenbronchialepithelzellen nach Inkubation mit dem wasserlöslichen NiCl2 (0,5 mM und 1 mM) sowie den wasserunlöslichen Verbindungen Ni3S2 (0,5 µg/cm2 und 1 µg/cm2) und NiS (2,5 µg/cm2) nachzuweisen und zu lokalisieren und konnten damit eine Akkumulation von Nickel im Zytoplasma und im Zellkern aufzeigen. Dabei war bei wasserlöslichen und wasserunlöslichen Nickelverbindungen Nickel nach 24 h im Zytoplasma und erst nach 48 h im Zellkern zu beobachten.rnrnDa Nickel und Cobalt keine detektierbare Eigenfluoreszenz unter den gegebenen Bedingungen zeigten, wurde für den optischen Nachweis von Nickel und Cobalt mit dem konfokalen Laser-Raster Mikroskop (CLSM) nach der Zugabe der verschiedenen wasserlöslichen und wasserunlöslichen Metallverbindungen NiCl2, NiSO4, Ni3S2 und CoCl2 in einzelnen lebenden humanen Gingiva-Fibroblasten, sowie in Pflanzenzellen in dieser Arbeit ebenfalls der optische Sensor Newport Green DCF genutzt. Korrespondierend zu den Ergebnissen früherer Arbeiten von Ke et al. (2006, 2007), in denen die Nickelaufnahme bei Konzentrationen von >0,5 mM NiCl2 bzw. >0,5 µg/cm2 Ni3S2 gezeigt wurde, wurde Nickel in Fibroblasten in Abhängigkeit von der Spezies mit steigender Metallkonzentration von 100 µM bis 500 µM nach 16 h im Zytoplasma und zunehmend nach 24 h bis 48 h im Zellkern detektiert. Bei der wasserunlöslichen Verbindung Ni3S2 war der Nachweis von Nickel im Zellkern bereits nach 16 h bis 24 h erfolgreich. Zusätzlich wurden weitere Strukturen wie das Endoplasmatische Retikulum, die Mitochondrien und die Nukleoli durch eine starke Fluoreszenz des optischen Sensors bei Colokalisationsexperimenten mit Organell-spezifischen Fluoreszenzfarbstoffen als target für die Nickelbindung vermutet. Die Lokalisation von Cobalt in den Fibroblasten entsprach weitgehend der Lokalisation von Nickel. Im Zellkern war die Cobaltlokalisation jedoch auf die Nukleoli beschränkt. Weiterführende Versuche an humanen Gingiva-Fibroblasten zeigten, dass die Aufnahme der Metalle in die Fibroblasten pH-Wert abhängig war. Niedrige pH-Werte im sauren pH-Bereich verringerten die Aufnahme der Metalle in die Zellen, wobei ein pH-Wert im basischen Bereich keinen bedeutenden Unterschied zum neutralen pH-Bereich aufwies. Im Vergleich zu den Fibroblasten war in Pflanzenzellen zu jedem Zeitpunkt, auch bei geringen Konzentrationen der Metallverbindungen sowie des optischen Sensors, Nickel und Cobalt in den Zellkernen detektierbar. Durch die Eigenschaft der Pflanzenzellen eine Vakuole zu besitzen, war Nickel und Cobalt hauptsächlich in den Vakuolen lokalisiert. Weitere Strukturen wie das Endoplasmatische Retikulum, die Mitochondrien oder auch die Zellwand kamen bei Pflanzenzellen als target in Frage.rnrnDie Fluoreszenz und Lokalisation der Metalle in den Fibroblasten waren unabhängig von der Spezies sehr ähnlich, sodass in den Zellen die Spezies anhand der fluoreszenzmikroskopischen Aufnahmen kaum unterschieden werden konnten. Lambda-Scans in verschiedenen regions of interest (ROI) wurden durchgeführt, um durch die Fluoreszenzspektren Hinweise auf eine charakteristische Beeinflussung der Bindungspartner von Nickel und Cobalt oder dieser Metalle selbst in den Zellen auf den optischen Sensor zu bekommen und diese dadurch identifizieren zu können. Das Ziel der parallelen Detektion bzw. Lokalisation und gleichzeitigen Speziation bestimmter Nickel- und Cobaltpezies in einzelnen lebenden Zellen konnte in dieser Arbeit durch den optischen Sensor Newport Green DCF nicht erreicht werden.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Cochin, commercial capital of Kerala, located on the west-coast of South India has a large number of chemical and sea food industries. Earlier studies in the past indicated that these industries contribute to heavy metal pollution, particularly mercury, copper, and cadmium, in Cochin backwater. Hence, in the present study, it was desired to isolate cadmium resistant bacteria from effluent discharged by chemical industry with a view to develop an ideal bioremediation process for safe discharge of industrial effluent in to the nearby aquatic environment. Effluent from three industries, located in the industrial belt of Cochin, were collected from the discharge point and cadmium resistant bacteria were screened using standard microbiological techniques