863 resultados para heat losses


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Heat transfer levels have been investigated behind a rearward-facing step in a superorbital expansion tube. The heat transfer was measured along a flat plate and behind 2 and 3mm steps with the same length to step height ratio. Results were obtained with air as the test gas at speeds of 6.76kms(-1) and 9-60kms(-1) corresponding to stagnation enthalpies of 26MJ/kg and 48MJ/kg respectively. A laminar boundary layer was established on the flat plate and measured heat transfer levels were consistent with classical empirical correlations. In the case of flow behind a step, the measurements showed a gradual rise in heat transfer from the rear of the step to a plateau several step heights downstream for both flow conditions. Reattachment distance was estimated to be approximately 1.6 step heights downstream of the 2mm step at the low enthalpy condition through the use of flow visualisation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To define the location of potential oncogenes and tumor suppressor genes in ocular melanoma we carried out comparative genomic hybridization (CGH) analysis on a population-based series of 25 formalin-fixed, paraffin-embedded primary tumors comprising 17 choroidal, 2 ciliary body, 4 iris, and 2 conjunctival melanomas. Twelve (48%) of the 25 melanomas showed no chromosomal changes and 13 (52%) had at least one chromosomal gain or loss. The mean number of CGH changes in all tumors was 3.3, with similar mean numbers of chromosomal gains (1.5) and losses (1.8). The highest number of chromosomal changes (i.e., nine) occurred in a conjunctival melanoma and included four changes not observed in tumors at any other ocular site (gains in 22q and 11p and losses in 6p and 17p). The most frequent gains in all primary ocular melanomas were on chromosome arm 8q (69%), 6p (31%) and 8p (23%) and the most frequent losses were on 6q (38%), 10q (23%), and 16q (23%). The most common pairing was gain in 8p and gain in 8q, implying a whole chromosome copy number increase; gains in 8p occurred only in conjunction with gains in 8q. The smallest regions of copy number alteration were mapped to gain of 8q21 and loss of 6q21, 10q21, and 16q22. Sublocalization of these chromosomal changes to single-band resolution should accelerate the identification of genes involved in the genesis of ocular melanoma.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ageing results in a progressive, intrinsic and generalised imbalance of the control of regulatory systems. A key manifestation of this complex biological process includes the attenuation of the universal stress response. Here we provide the first global assessment of the ageing process as it affects the heat shock response, utilising human peripheral lymphocytes and cDNA microarray analysis. The genomic approach employed in our preliminary study was supplemented with a proteomic approach. In addition, the current study correlates the in vivo total antioxidant status with the age-related differential gene expression as well as the translational kinetics of heat shock proteins (hsps). Most of the genes encoding stress response proteins on the 4224 element microarray used in this study were significantly elevated after heat shock treatment of lymphocytes obtained from both young and old individuals albeit to a greater extent in the young. Cell signaling and signal transduction genes as well as some oxidoreductases showed varied response. Results from translational kinetics of induction of major hsps, from 0 to 24 It recovery period were broadly consistent with the differential expression of HSC 70 and HSP 40 genes. Total antioxidant levels in plasma from old individuals were found to be significantly lower by comparison with young, in agreement with the widely acknowledged role of oxidant homeostasis in the ageing process. (C) 2002 Elsevier Science Ireland Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Twenty-one strains of Bacillus (10 B. stearothermophilus, 3 B. cereus, and 8 B. licheniformis strains) were assayed for spore surface hydrophobicity on the basis of three measures: contact angle measurement (CAM), microbial adhesion to hydrocarbons (MATH), and hydrophobic interaction chromatography (HIC). On the basis of the spore surface characteristics obtained from these assays, along with data on the heat resistance of these spores in water, eight strains of Bacillus (three B. stearothermophilus, three B. cereus, and two B. licheniformis strains) either suspended in water or adhering to stainless steel were exposed to sublethal heat treatments at 90 to 110degreesC to determine heat resistance (D-value). Significant increases in heat resistance (ranging from 3 to 400%) were observed for the eight strains adhering to stainless steel. No significant correlation was found between these heat resistance increases and spore surface characteristics as determined by the three hydrophobicity assays. There was a significant positive correlation between the hydrophobicity data obtained by the MATH assay and those obtained by the HIC assay, but these data did not correlate with those obtained by the CAM assay.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Raw milk was stored for 0, 2 and 4 days and processed in a UHT pilot plant by either direct or indirect heating. The unstored raw milk was also pasteurised. The thermally induced changes resulting from these treatments were investigated by examining a number of indices of heat damage. Lactulose, furosine, total and free hydroxymethylfurfural (HMF) and acid-soluble beta-lactoglobulin were analysed by high performance liquid chromatography (HPLC) while soluble tryptophan was examined by fluorescence spectroscopy. The directly heated UHT milk showed less heat damage than the indirectly heated milk, while the pasteurised milk displayed the least heat damage. During storage of the UHT milk for 12 weeks at similar to20degreesC, the levels of lactulose remained constant, while the furosine concentration increased. Both the total HMF and undenatured beta-lactoglobulin contents showed a general decrease during storage; however free HMF values initially rose but then decreased after four weeks' storage. As the age of the milk at the time of UHT processing increased, the levels of some of the indicators decreased. It is concluded that lactulose is the most reliable index of heat treatment, as it is virtually unaffected by refrigerated storage of the milk before or ambient storage after UHT processing. Reliance on other indicators may give misleading information on the heat load that UHT milk has received during processing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

1. Two broiler experiments and a layer experiments were conducted on Kunitz trypsin inhibitor (Kti) soybeans (SB) of low trypsin inhibitor (TI) activity to determine their nutritive value when included as mash in least-cost poultry diets. 2. Experiment 1 compared chick performance on the Kti or raw SB using a commercial full-fat SB meal (FFSBM) and a solvent extracted SB meal (SBM) as controls during a 20 d experimental period. Broiler experiment 2 compared Kti and raw SB, non-steamed, or steam-pelleted with and without DL-methionine supplementation added to every treatment containing 170 g SB/kg. For each broiler experiment the levels of each SB were 70, 120 and 170 g/kg with the control birds fed only 170 g SB/kg. 3. The layer experiment, compared steam-pelleted Kti and raw SB against a non-steamed Kti and raw SB each fed at two levels (70 and 110 g/kg) x 30 replicates from 29 weeks of age for 19 weeks in a completely randomised design. Production parameters were measured when diets were formulated to contain minimum required specifications and calculated apparent metabolisable energy (AME). At the completion of each trial, 2 broiler birds from each cage and 5 layer birds per treatment were killed, weighed, and their liver and pancreas weighed. 4. Both broiler experiments indicated that production parameters on the Kti SB treatments were significantly lower (P < 0.05) than on the two commercial control SB treatments. However, the Kti treatments were superior to the raw SB treatments. 5. Pancreas weight increased with increasing inclusion of both raw and Kti SB, suggesting that a TI was causing the depression in performance. The AME of the Kti SB was similar to that of commercial FFSB meal. After steam conditioning, the raw SB meal AME value of 9.5 MJ/kg dry matter (DM) was improved to 14.1 MJ/kg DM by reduced TI activity, but this AME improvement with TI activity reduction, plus the supplementation with DL-methionine on birds fed the raw SB had no effect (P > 0.05) on any parameter evaluated in experiment 2. 6. The layer experiment showed that hens on the Kti SB treatments had significantly greater live weight gain (LWG), egg weight and daily egg mass than birds given raw SB. A reduced food intake (FI) was observed in the Kti treatments but egg mass was generally similar to that on the FFSB control diet, indicating that Kti SB supported excellent egg production at an inclusion of 110 g/kg. The depressed performance observed for broiler chicks suggest that younger birds are more susceptible to the effects of SB TI.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Heat shock and salicylic acid have been studied on shelf-life extension of fruits. The benefits of these techniques have been related to their effect on inducing physiological defense responses against the oxidative stress and pathogen development. The objective of this study was to evaluate the effect of heat shock and salicylic acid on the postharvest preservation and contents of total phenolics, anthocyanins, ascorbic acid, fresh weight loss and microbiological quality of organic strawberries cv. Dover. Strawberries produced organically and stored at 5 ºC were subjected to heat shock (45 ºC ± 3 ºC for 3 h), application of salicylic acid (soaking in 2.0 mmol L-1 solution), heat shock in combination with salicylic acid and control. After treatment, the fruits were packed and stored in a climatic chamber at 5 ºC ± 2 ºC. At 1, 7 and 14 days, the experimental units were removed from refrigeration and kept at room temperature of approximately 20 ºC for two days. There was no effect of treatments on fresh weight loss, incidence of pathogens or chemical variations in strawberry fruits during the storage period. In natural conditions, organically grown strawberries remained in good condition for sale up to seven days of storage in all treatments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract: There is a need for heat tolerant wheat cultivars adapted to the expansion of cultivation areas in warmer regions due to the high demand of this cereal for human consumption. The objective of this study was to evaluate the effect of high temperatures on grain yield and yield components of wheat and characterize heat tolerant wheat genotypes at different development stages. The genotypes were evaluated in the field with and without heat stress. High temperatures reduced the number of spikelets per spike (21%), number of grains per spike (39%), number of grains per spikelet (23%), 1000-grain weight (27%) and grain yield (79%). Cultivars MGS 1 Aliança, Embrapa 42, IAC 24-Tucuruí and IAC 364-Tucuruí III are the most tolerant to heat stress between the stages double ridge and terminal spikelet; MGS 1 Aliança, BRS 264, IAC 24-Tucuruí, IAC 364-Tucuruí III and VI 98053, between meiosis and anthesis; and BRS 254, IAC-24-Tucuruí, IAC-364-Tucuruí III and VI 98053, between anthesis and physiological maturity. High temperatures reduce grain yield and yield components. The number of grains per spike is the most reduced component under heat stress. The genotypes differed in tolerance to heat stress in different developmental stages.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Demand for power is growing every day, mainly due to emerging economies in countries such as China, Russia, India, and Brazil. During the last 50 years steam pressure and temperature in power plants have been continuously raised to improve thermal efficiency. Recent efforts to improve efficiency leads to the development of a new generation of heat recovery steam generator, where the Benson once-through technology is applied to improve the thermal efficiency. The main purpose of this paper is to analyze the mechanical behavior of a high pressure superheater manifold by applying finite element modeling and a finite element analysis with the objective of analyzing stress propagation, leading to the study of damage mechanism, e.g., uniaxial fatigue, uniaxial creep for life prediction. The objective of this paper is also to analyze the mechanical properties of the new high temperature resistant materials in the market such as 2Cr Bainitic steels (T/P23 and T/P24) and also the 9-12Cr Martensitic steels (T/P91, T/P92, E911, and P/T122). For this study the design rules for construction of power boilers to define the geometry of the HPSH manifold were applied.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The operation of power systems in a Smart Grid (SG) context brings new opportunities to consumers as active players, in order to fully reach the SG advantages. In this context, concepts as smart homes or smart buildings are promising approaches to perform the optimization of the consumption, while reducing the electricity costs. This paper proposes an intelligent methodology to support the consumption optimization of an industrial consumer, which has a Combined Heat and Power (CHP) facility. A SCADA (Supervisory Control and Data Acquisition) system developed by the authors is used to support the implementation of the proposed methodology. An optimization algorithm implemented in the system in order to perform the determination of the optimal consumption and CHP levels in each instant, according to the Demand Response (DR) opportunities. The paper includes a case study with several scenarios of consumption and heat demand in the context of a DR event which specifies a maximum demand level for the consumer.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In recent decades, all over the world, competition in the electric power sector has deeply changed the way this sector’s agents play their roles. In most countries, electric process deregulation was conducted in stages, beginning with the clients of higher voltage levels and with larger electricity consumption, and later extended to all electrical consumers. The sector liberalization and the operation of competitive electricity markets were expected to lower prices and improve quality of service, leading to greater consumer satisfaction. Transmission and distribution remain noncompetitive business areas, due to the large infrastructure investments required. However, the industry has yet to clearly establish the best business model for transmission in a competitive environment. After generation, the electricity needs to be delivered to the electrical system nodes where demand requires it, taking into consideration transmission constraints and electrical losses. If the amount of power flowing through a certain line is close to or surpasses the safety limits, then cheap but distant generation might have to be replaced by more expensive closer generation to reduce the exceeded power flows. In a congested area, the optimal price of electricity rises to the marginal cost of the local generation or to the level needed to ration demand to the amount of available electricity. Even without congestion, some power will be lost in the transmission system through heat dissipation, so prices reflect that it is more expensive to supply electricity at the far end of a heavily loaded line than close to an electric power generation. Locational marginal pricing (LMP), resulting from bidding competition, represents electrical and economical values at nodes or in areas that may provide economical indicator signals to the market agents. This article proposes a data-mining-based methodology that helps characterize zonal prices in real power transmission networks. To test our methodology, we used an LMP database from the California Independent System Operator for 2009 to identify economical zones. (CAISO is a nonprofit public benefit corporation charged with operating the majority of California’s high-voltage wholesale power grid.) To group the buses into typical classes that represent a set of buses with the approximate LMP value, we used two-step and k-means clustering algorithms. By analyzing the various LMP components, our goal was to extract knowledge to support the ISO in investment and network-expansion planning.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mestrado em Engenharia Química

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A Indústria Têxtil do Ave S.A. (ITA) dedica-se, desde 1948, à produção de componentes têxteis para pneus em forma de fio torcido (corda) e tela. Estes componentes são quimicamente activados e impregnados em estufas, possibilitando assim a posterior adesão ao pneu. A máquina de impregnar corda Single End é composta pelos grupos de estiragem, por um recipiente contendo a solução química e por 4 estufas em série. A máquina de impregnar tela Zell é composta pelos grupos de estiragem, pelos acumuladores de saída e entrada, pelos recipientes com as soluções químicas e por um grupo de 7 estufas em série. O aquecimento das estufas é feito através da queima de gás natural. O presente trabalho teve como objectivo a realização de uma auditoria energética à ITA com um especial destaque às máquinas de impregnar corda (Single End) e tela (Zell). As correntes de entrada que contribuem para a potência térmica de impregnação são a combustão do gás natural, o ar de combustão, o ar fresco, o artigo em verde e as soluções químicas. As correntes de saída correspondem aos gases de combustão e exaustão, ao artigo impregnado e às perdas térmicas. A auditoria à máquina Single End mostrou que a potência térmica de impregnação é de 413,1 kW. Dessa potência térmica, 77,2% correspondem à combustão do gás natural, 6,7% ao ar de combustão, 15% ao ar fresco, 0,7% às cordas em verde e 0,4% à solução química. Da potência térmica de saída, 88,4% correspondem aos gases de combustão e exaustão, 3,2% às cordas impregnadas e 8,4% às perdas térmicas. Da auditoria à máquina Zell observou-se que a potência térmica de impregnação é de 5630,7 kW. Dessa potência, 73,3% corresponde à combustão do gás natural, 1,6% ao ar de combustão, 24,5% ao ar fresco, 0,3% à tela em verde e 0,3% às soluções químicas. Da potência térmica de saída, 65,2% correspondem aos gases de combustão e exaustão, 3,1% à tela impregnada e 31,7% às perdas térmicas. Foram sugeridas como medidas de optimização a redução dos caudais de exaustão das estufas e o aumento de temperatura do ar fresco. O aumento da temperatura do ar fresco da máquina de impregnar Single End para 50 ºC, usando ar quente dos torcedores, leva a uma poupança de 0,22 €/h, com um período de retorno do investimento de 13 anos e 4 meses enquanto o aumento para 120 ºC, usando o calor dos gases de combustão e exaustão, reduz os custos em 0,88 €/h, sendo o período de retorno para esse investimento de 2 anos e 6 meses. Na máquina de impregnar Zell, uma redução de 15% no caudal de exaustão numa das estufas leva a ganhos de 3,43 €/h. O aumento de temperatura do ar fresco para 45 ºC, usando o calor de gases de combustão e exaustão, leva a uma poupança de 9,93 €/h sendo o período de retorno para cada uma das duas sugestões de investimento de 5 meses e 9 meses.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Como o sector cerâmico é um consumidor intensivo de energia, este trabalho teve como objectivo principal a elaboração de um plano de optimização do desempenho energético da olaria número três da Fábrica Cerâmica de Valadares. Para o efeito, efectuou-se o levantamento energético desta fracção autónoma. O valor total obtido para os ganhos térmicos foi de 8,7x107 kJ/dia, sendo 82% desta energia obtida na combustão do gás natural. Por outro lado, as perdas energéticas rondam os 8,2x107 kJ/dia, sendo o ar de exaustão e a envolvente os principais responsáveis, com um peso de 42 % e 38%, respectivamente. Tendo em conta estes valores, estudaram-se várias medidas de isolamento da cobertura, pavimento, paredes e saída de ar através de fendas do edifício. No caso do isolamento da cobertura sugeriu-se a substituição das telhas de fibrocimento e do isolamento actualmente existentes por painéis sandwich de cobertura. Esta acção permite uma poupança de 64.796€/ano, com um investimento de 57.029€ e o seu período de retorno de 0,9 anos. O Valor Actualizado Líquido (VAL) no 5º ano foi de 184.069€, com uma Taxa Interna de Rentabilidade (TIR) de 92%. Para isolar o pavimento, sugeriu-se a utilização de placas de poliuretano expandido (PU) de 20mm de espessura. Assim, consegue-se uma poupança de 7.442 €/ano, com um investimento de 21.708€, e um tempo de retorno 2,9 anos. No final do 5º ano de vida útil do projecto, o VAL é de 4.070€ e a TIR 7%. Relativamente ao isolamento das paredes e pilares, sugeriu-se a utilização de placas de PU (30mm), recobertas com chapa de ferro galvanizado. O tempo de retorno do investimento é de 1,5 anos, uma vez que, o investimento é de 13.670€ e a poupança anual será de 9.183€. Esta solução apresenta no último ano um VAL de 12.835€ e uma TIR de 22%. No isolamento das fendas do edifício, sugeriu-se a redução de 20% da sua área livre. Esta medida de optimização implica um investimento de 8.000€, revelando-se suficientemente eficaz, pois apresenta um tempo de retorno de 0,67 anos. O VAL e a TIR da solução no último ano de vida útil do projecto de investimento são de 36.835€ e 35%, respectivamente. Por fim, sugeriu-se ainda a instalação de um sistema de controlo que visa o aproveitamento de ar quente proveniente do forno, instalado no piso inferior à olaria, para pré-aquecer o ar alimentado aos geradores de calor. Esta medida implicaria um investimento de 4.000€, com um tempo de retorno de 2,4 anos e uma poupança anual é de 1.686€. O investimento é aconselhável, já que, no 5º ano, o VAL é de 1.956€ e a TIR é de 17%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Na indústria cerâmica o consumo de energia é elevado, fazendo com que este custo represente uma parte significativa dos custos totais de produção das peças. De forma a diminuir esta dependência, a energia deve ser gerida de forma contínua e eficazmente. O presente trabalho consistiu na análise da situação energética e na elaboração de propostas de optimização da etapa de conformação que ocorre na Olaria número quatro da Fábrica Cerâmica de Valadares, S.A. Determinou-se o rendimento efectivo da Olaria, tendo-se obtido um valor de 24,7%. As perdas térmicas ocorrem na Olaria, a nível da envolvente, da ventilação, da exaustão de gases e da inércia térmica, representando, respectivamente, 18122 MJ, 50222 MJ, 39228 MJ e 4338 MJ por semana de trabalho. Numa última fase sugeriram-se algumas medidas de optimização energética. A primeira medida visa uma melhoria na manutenção dos geradores, um aumento na gama de temperaturas de funcionamento dos geradores e uma minimização dos tempos de abertura dos portões. Na segunda medida propõe-se a diminuição da percentagem de excesso de ar para 10%, equivalendo a uma poupança de 8839 €/ano. Na terceira medida avaliou-se a possibilidade da aplicação de um permutador de calor de modo a aproveitar os gases de combustão. Esta permitiria uma poupança de 119 €/ano, no entanto, devido ao elevado tempo de retorno do investimento (12,6 anos) considerou-se que esta medida não era viável. A quarta proposta relaciona-se com a optimização da ventilação da Olaria por aumento do ciclo de renovação de ar para 5 h, promovendo uma poupança de 8583 € anuais. Como última sugestão de optimização, aconselhou-se a diminuição do volume da olaria em 6935 m3. Com esta proposta é possível obter uma poupança de 4993 €/ano. Esta medida envolve um investimento de 12000 €, sendo o tempo de retorno do investimento de 2,4 anos. Das cinco propostas estudadas concluiu-se que quatro são viáveis permitindo uma melhoria do funcionamento da Olaria e uma poupança significativa na factura energética.