300 resultados para esthetics
Resumo:
Objective: Evaluate the impact of the use of strip adhesive over the quality of life of institutionalized patients and wearers of complete dentures. Material and method: Twenty-nine institutionalized patients wearers of complete denture were selected to this study and after a clinical exam, a questionnaire (adjusted and based upon the index of Oral Health Impact Profile and Oral Health-Related Quality of Life, OHIP and OHQOL) was applied to evaluate issues related to epidemiological conditions (gender and age), quality of life (pain, discomfort, functional limitations, phonetic, social, psychological and esthetic), taste and notion of implant treatment. Following this part, the patients received instruction to use the strips adhesives (Corega Fita Adesiva, Glaxo-Smith-Kline, Rio de Janeiro, Brazil), considering three in maxillary prosthesis and two in the lower prosthesis during a period of 30 days. After this period, all the patients were recall and the questionnaire was reapplied; add some adhesive performance questions, to compare the results before and after the adhesive use in terms of percentage. Result: After the adhesive strips use there were improvement of the functional, social and physcological limitation aspects, but without percentual increasement of phonetic and esthetics aspects. The results showed 65.5% of the answers stating adhesive maintenance between 6-12 hours, easy removal (68.9%), and without change the taste (89.6%). The notion for implant treatment was decreased changing from 75.8 to 37.9% after the adhesive use. Conclusion: The results enhanced a positive impact over quality of life of the respondents after the strip adhesive use, showing decrease of pain and discomfort, mainly of inferior dental prosthesis.
Resumo:
Esthetics and durability of materials used to fabricate artificial eyes has been an important issue since artificial eyes are essential to restore esthetics and function, protect the remaining tissues and help with patients' psychological therapy. However, these materials are submitted to degrading effects of environmental agents on the physical properties of the acrylic resin. OBJECTIVE: This study assessed the color stability of acrylic resins used to fabricate sclera in three basic shades (N1, N2 and N3) when subjected to accelerated aging, mechanical and chemical polishing. MATERIAL AND METHODS: Specimens of each resin were fabricated and submitted to mechanical and chemical polishing. Chromatic analysis was performed before and after accelerated aging through ultraviolet reflection spectrophotometry. RESULTS: All specimens revealed color alteration following polishing and accelerated aging. The resins presented statistically significant chromatic alteration (p<0.01) between the periods of 252 and 1008 h. CONCLUSIONS: Both polishing methods presented no significant difference between the values of color derivatives of resins.
Resumo:
The osseointegrated implants created a progress in oral rehabilitation. But this rehabilitation may be complicated by anatomical conditions, mainly in maxillary anterior region, where a higher aesthetic is required. The aim of study was to report one case which the use of angled abutments were necessary to allow the correct positioning of the prosthesis and also the prosthetic reconstruction with gingival-colored ceramic to provide best aesthetic result for patient. The aesthetic and functional results provided greater patient satisfaction with her smile. The correct planning is essential to provide to patient the best aesthetic and functional results, being necessary the use of abutments and gingival-colored ceramic to reach better results. Uniterms: dental implantacion, esthetics, mouth rehabilitation.
Resumo:
The determination of occlusal vertical dimension (OVD) is one of the most important steps in the rehabilitation treatment. Although various techniques have been used to measure it, none has proven to be scientifically accurate. Thus, the purpose of this study was to survey the different methods of measuring the vertical dimension and describe the clinical sequence of a method that we deem reliable.
Resumo:
Zirconia abutments are used to obtain satisfactory aesthetic results in implant fixed anterior prostheses when metal abutments promote a grayish mucosal discoloration of the peri-implant soft tissues. However, there is a lack of studies to confirm the clinical performance of the peri-implant soft tissues surrouding zirconia abutments. This study described a case report of a patient treated with implant fixed all-ceramic crown made out on zirconia abutment after 3 years of followup. A 47-year-old female patient was admitted to the dental clinic (Aracatuba Dental School) complaining about the fracture of her implant fixed single crown in the region of the left lateral incisor. The patient chose the replacement of the fractured prosthesis for an allceramic crown. After 3 years of follow-up it was observed that maintenance of the aesthetic results and the peri-implant soft tissue without any inflammation or gingival recessions. Within the limitations of a case report, it can be conclude that zirconia abutments is a effective rehabilitation treatment because it preserves the aesthetics and function through the maintenance of peri-implant tissues.
Resumo:
An important phase of rehabilitation treatment, is the aesthetic and functional testing, performed with the patient. Its relevance is because at this time it’s possible to have a very faithful preview of the final result of the prosthesis, but, if necessary, still allow changes. Therefore, the objective of this review is to describe didactically the clinical steps and factors that should be examined by the dentist at the moment of aesthetic and functional testing of a complete denture. This clinical stage basically involves four requirements to be analyzed: mechanical, functional, aesthetic and phonetic. After the jointly analysis with all the requirements, the patient must approve, preferably in writing, the completion of the prosthesis. In case of need for any changes, this is when it should be performed, followed by new aesthetic and functional testing. It should be noted that the patient’s opinion is always sovereign in deciding to end the denture.
Resumo:
The literature has suggested that the association of removable partial dentures with dental implants can improve the quality of life of patients. Thus, the purpose of this study was to present a case report. This case report describes the development of a removable partial denture associated with dental implants bilaterally been monitored for 12 years, and the efficacy of the proposed treatment. The radiographic controls demonstrated no changes on bone tissue. The maxillary arch was rehabilitated with metal-free crowns. The patient was fully satisfied with this technique providing stability, esthetics, and proper function. It was concluded that the technique of using removable partial dentures associated with dental implants is viable and show the advantages of improved function, aesthetics and cost reductions in rehabilitation treatment.
Resumo:
Objective: The use of methods for tissue regeneration has been widely applied in Implantology, in clinical situations with disabilities or anatomical limitations that prevent the placement of osseointegrated dental implants. The evolution of the development of biomaterials revolutionized this therapeutic modality, facilitating the resolution of clinical cases with tissue deficiencies. Thus, this study aimed to describe a clinical case approaching the methods, techniques, and materials used in guided bone regeneration applied to Implantology. Case report: A clinical case of a patient who received a Morse taper dental implant (region 15) is described. The use of biomaterial and membrane on the buccal wall of the socket was required. After the osseointegration period, a reopening surgery was performed, and an immediate provisional implant was produced. After 2 months of follow-up, the final prosthesis was made involving other adjacent elements. Final considerations: The guided bone regeneration technique employed showed satisfactory performance. The patient was positive regarding esthetics and function. However, more controlled studies with longer follow-up period are needed for analyses of predictability
Resumo:
AIM: The aim of this study is to present a clinical case in which an occlusal matrix device was used in a patient who needed to restore a posterior tooth. MATERIAL AND METHODS: A direct duplicate occlusal appliance was used (biteperf) in a patient who needed an occlusal restoration in two posterior teeth. RESULTS: Using the matrix helps having fast and accurate reproduction of the original anatomical details of the occlusal surface. The final result surprised with the presented restoration in terms of esthetic quality, despite the simplicity of the technique. CONCLUSION: Posterior teeth with initial lesions were confined to the occlusal surface of anatomically complex or fissured anatomy with or without signs of proximal caries wich are ideal candidates for this technique. The overlying enamel surface must be relatively intact; lesions of hidden or occult caries. CLINICAL SIGNIFICANCE: The aesthetic and time-saving benefits of the occlusal device (biteperf) are immediately clear. The matrix allows the fast and accurate reproduction of the anatomic details of the original occlusal surface of the tooth. The professionals who lack an artistic penchant and marked manual ability will be able to carry out excellent posterior resin composite restorations.
Resumo:
Many patients seeking dental care wish to improve facial and smile aesthetics to be accepted in modern day society. In denture wearers, the physiological resorption causes atrophy mainly in the maxilla, being necessary to carry out reconstruction techniques and sometimes orthognathic surgery to improve occlusal stability and facial harmony. The aim of this study is to discuss the features related to the rehabilitation of edentulous patients with indication for reconstruction of the maxilla using bone grafts and orthognathic surgery by means of a clinical case. In the present case, after the prosthetic rehabilitation, the patient was full satisfied with obtained results and dismissed the initially proposed surgical protocol. Therefore, professionals should provide therapeutic options but the patient’s opinion should prevail provided its clinical feasibility.
Resumo:
The evolution of ceramic systems currently allows the manufacture of prosthesis similar to the natural teeth, meeting the expectations of patients. However, when using vitreous ceramic the color of substrate is significant for the esthetic result, requiring planning aesthetic cores when involved reconstruction of endodontically treated teeth without coronal structure. Thus, the aim of this study to describe a case report of aesthetic rehabilitation in upper anterior teeths using vitreous ceramic system for the reconstruction of elements: 11, 12, 21 and 22 after endodontically treated. It was emphasized the removal of crowns and manufacture of custom cast post and core with ceramic in coronal portion, prioritizing the aesthetic result. Through the clinical results observed can be seen that the use of custom cast post and core with ceramic in association lithium disilicate glass ceramics provided a satisfactory aesthetic result.
Resumo:
The evolution of techniques and materials applied to adhesive ceramic restorations resulted in the intensification of its use, proving to be an excellent method of aesthetic restoration. Some important features of this technique are its conservative preparation, which avoids an excessive loss of tooth structure and its high aesthetic value provided by the ceramic even when utilized under different color of dental substrates. The aim of this paper was to report a clinical case with full crowns, porcelain veneers and non-prep veneers, enhancing peculiarities related to the material used, tooth preparation techniques, cementing, indications and contraindications.
Resumo:
In many oral rehabilitation professionals seeking venture renew people smile. However, these procedures have functional implications and aesthetic criteria which must be satisfied so that the final result is predictable. The restoration of relations intermaxillary, phonetics, masticatory function, esthetics and patient comfort are the goals to be achieved. An effective way to achieve these goals when immediate reconstruction with permanent dentures is not possible, make use of a type of partial denture called overlay. Bruxism is a manifestation of biopsychological imbalance that affects the stomatognathic system, characterized by clenching and / or attrition of teeth together so centric or eccentric, can be manifestation of nocturnal or diurnal. Its effects can manifest themselves in different parts of the stomatognathic system, varying the severity of the damage as the resistance of the structures affected, the time of existence, its regularity and the general state of the wearer. The description of the steps followed in solving this case, in which the patient edentulous mandibular arch while the maxillary arch showed absence of teeth 16 and 26 and, except for the teeth 17 and 27, all other teeth showed wear very sharp in the sense denoting incisal cervical, severe impairment of the vertical dimension, the quality of masticatory function and a marked impairment phonetic, this case report aims to guide the beginning of a rehabilitation, as well as the transitional phase of treatment for recovery of functional and aesthetic relationships intermaxillary .
Resumo:
Several alloys have been used for prosthodontics restorations in the last years. These alloys have a number of metals that include gold, palladium, silver, nickel, cobalt, chromium and titanium and they are used in oral cavity undergo several corrosion. Corrosion can lead to poor esthetics, compromise of physical properties, or increased biological irritation. The objective of this study was evaluated corrosion resistance of two alloys Ni-Cr and Ni-Cr-Ti in three types of mouthwashes with different active ingredients: 0.5g/l cetylpyridinium chloride + 0.05% sodium fluoride, 0.05% sodium fluoride + 0.03% triclosan (with fluor) and 0.12% chlorohexidine digluconate. The potentiodynamic curves were performed by means of an EG&G PAR 283 potentiostat/galvanostat. The counter electrode was a platinum wire and reference electrode was an Ag/AgCl, KCl saturated. Before each experiment, working electrodes were mechanically polished with 600 and 1200 grade papers, rinsed with distilled water and dried in air. All experiments were carried out at 37.0oC in conventional three-compartment double wall glass cell containing mouthwashes. The microstructures of two alloys were observed in optical microscopy. Analysis of curves showed that Ni-Cr alloy was less reactive in the presence of 0.12% chlorohexidine digluconate while Ni-Cr-Ti alloy was more sensitive for others two types of mouthwashes (0.5g/l cetylpyridinium chloride + 0.05% sodium fluoride and 0.05% sodium fluoride + 0.03% triclosan). This occurred probably due presence of titanium in this alloy. Microstructural analysis reveals the presence of dendritic and eutectic microstructures for NiCr and Ni-Cr-Ti, respectively.
Resumo:
Aim: compare the evaluation of orthodontics and lay people on facial attractiveness of pattern II and III subjects. Methodology: thirty orthodontists and 30 laymen judged a profile facial photos of 64 subjects standard II and III (34 standard II e 30 standard III), making as visual analogical scale (VAS) with 10 cm. Results: after evaluation, the results were submitted to a statistics analysis (Mann- Whitney test) showed that the groups of evaluators orthodontists and lay people differed in their assessments, and these differences are statistically significant. Conclusions: the laymen was more rigorous than orthodontics, and both considered the female pattern III more agradable.