959 resultados para automated software testing
Resumo:
There is a need for more efficient methods giving insight into the complex mechanisms of neurotoxicity. Testing strategies including in vitro methods have been proposed to comply with this requirement. With the present study we aimed to develop a novel in vitro approach which mimics in vivo complexity, detects neurotoxicity comprehensively, and provides mechanistic insight. For this purpose we combined rat primary re-aggregating brain cell cultures with a mass spectrometry (MS)-based metabolomics approach. For the proof of principle we treated developing re-aggregating brain cell cultures for 48h with the neurotoxicant methyl mercury chloride (0.1-100muM) and the brain stimulant caffeine (1-100muM) and acquired cellular metabolic profiles. To detect toxicant-induced metabolic alterations the profiles were analysed using commercial software which revealed patterns in the multi-parametric dataset by principal component analyses (PCA), and recognised the most significantly altered metabolites. PCA revealed concentration-dependent cluster formations for methyl mercury chloride (0.1-1muM), and treatment-dependent cluster formations for caffeine (1-100muM) at sub-cytotoxic concentrations. Four relevant metabolites responsible for the concentration-dependent alterations following methyl mercury chloride treatment could be identified using MS-MS fragmentation analysis. These were gamma-aminobutyric acid, choline, glutamine, creatine and spermine. Their respective mass ion intensities demonstrated metabolic alterations in line with the literature and suggest that the metabolites could be biomarkers for mechanisms of neurotoxicity or neuroprotection. In addition, we evaluated whether the approach could identify neurotoxic potential by testing eight compounds which have target organ toxicity in the liver, kidney or brain at sub-cytotoxic concentrations. PCA revealed cluster formations largely dependent on target organ toxicity indicating possible potential for the development of a neurotoxicity prediction model. With such results it could be useful to perform a validation study to determine the reliability, relevance and applicability of this approach to neurotoxicity screening. Thus, for the first time we show the benefits and utility of in vitro metabolomics to comprehensively detect neurotoxicity and to discover new biomarkers.
Resumo:
This paper examines statistical analysis of social reciprocity at group, dyadic, and individual levels. Given that testing statistical hypotheses regarding social reciprocity can be also of interest, a statistical procedure based on Monte Carlo sampling has been developed and implemented in R in order to allow social researchers to describe groups and make statistical decisions.
Resumo:
Kansas State University, with funding from the Kansas Department of Transportation (KDOT), has developed a computerized reduction system for profilograms produced by mechanical profilographs. The commercial version of the system (ProScan (trademark)) is marketed by Devore Systems, Inc. The system consists of an IBM Compatible PC 486SX33 computer or better, Epson LQ-570 printer, a Logitech Scanman 32 hand scanner system, a paper transport unit, and the ProScan software. The Scanner is not adaptable to IBM computers with the micro channel architecture. The Iowa DOT Transportation Centers could realize the following advantages by using ProScan: (1) Save about 5 to 8 staff hours of reduction and reporting time per Transportation Center per week for a Materials Technician 3 or 4 (the time savings would come during the busiest part of the season); (2) Reduce errors in reduction, transfer, and typing of profile values; (3) Increase the accuracy of the monitor results; and (4) Allow rapid evaluation of contractor traces when tolerance limits between monitor and certified results are exceeded.
Resumo:
OBJECTIVE: Imaging during a period of minimal myocardial motion is of paramount importance for coronary MR angiography (MRA). The objective of our study was to evaluate the utility of FREEZE, a custom-built automated tool for the identification of the period of minimal myocardial motion, in both a moving phantom at 1.5 T and 10 healthy adults (nine men, one woman; mean age, 24.9 years; age range, 21-32 years) at 3 T. CONCLUSION: Quantitative analysis of the moving phantom showed that dimension measurements approached those obtained in the static phantom when using FREEZE. In vitro, vessel sharpness, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were significantly improved when coronary MRA was performed during the software-prescribed period of minimal myocardial motion (p < 0.05). Consistent with these objective findings, image quality assessments by consensus review also improved significantly when using the automated prescription of the period of minimal myocardial motion. The use of FREEZE improves image quality of coronary MRA. Simultaneously, operator dependence can be minimized while the ease of use is improved.
Resumo:
Background: Research in epistasis or gene-gene interaction detection for human complex traits has grown over the last few years. It has been marked by promising methodological developments, improved translation efforts of statistical epistasis to biological epistasis and attempts to integrate different omics information sources into the epistasis screening to enhance power. The quest for gene-gene interactions poses severe multiple-testing problems. In this context, the maxT algorithm is one technique to control the false-positive rate. However, the memory needed by this algorithm rises linearly with the amount of hypothesis tests. Gene-gene interaction studies will require a memory proportional to the squared number of SNPs. A genome-wide epistasis search would therefore require terabytes of memory. Hence, cache problems are likely to occur, increasing the computation time. In this work we present a new version of maxT, requiring an amount of memory independent from the number of genetic effects to be investigated. This algorithm was implemented in C++ in our epistasis screening software MBMDR-3.0.3. We evaluate the new implementation in terms of memory efficiency and speed using simulated data. The software is illustrated on real-life data for Crohn’s disease. Results: In the case of a binary (affected/unaffected) trait, the parallel workflow of MBMDR-3.0.3 analyzes all gene-gene interactions with a dataset of 100,000 SNPs typed on 1000 individuals within 4 days and 9 hours, using 999 permutations of the trait to assess statistical significance, on a cluster composed of 10 blades, containing each four Quad-Core AMD Opteron(tm) Processor 2352 2.1 GHz. In the case of a continuous trait, a similar run takes 9 days. Our program found 14 SNP-SNP interactions with a multiple-testing corrected p-value of less than 0.05 on real-life Crohn’s disease (CD) data. Conclusions: Our software is the first implementation of the MB-MDR methodology able to solve large-scale SNP-SNP interactions problems within a few days, without using much memory, while adequately controlling the type I error rates. A new implementation to reach genome-wide epistasis screening is under construction. In the context of Crohn’s disease, MBMDR-3.0.3 could identify epistasis involving regions that are well known in the field and could be explained from a biological point of view. This demonstrates the power of our software to find relevant phenotype-genotype higher-order associations.
Resumo:
Recent reports indicate that of the over 25,000 bridges in Iowa, slightly over 7,000 (29%) are either structurally deficient or functionally obsolete. While many of these bridges may be strengthened or rehabilitated, some simply need to be replaced. Before implementing one of these options, one should consider performing a diagnostic load test on the structure to more accurately assess its load carrying capacity. Frequently, diagnostic load tests reveal strength and serviceability characteristics that exceed the predicted codified parameters. Usually, codified parameters are very conservative in predicting lateral load distribution characteristics and the influence of other structural attributes. As a result, the predicted rating factors are typically conservative. In cases where theoretical calculations show a structural deficiency, it may be very beneficial to apply a "tool" that utilizes a more accurate theoretical model which incorporates field-test data. At a minimum, this approach results in more accurate load ratings and many times results in increased rating factors. Bridge Diagnostics, Inc. (BDI) developed hardware and software that are specially designed for performing bridge ratings based on data obtained from physical testing. To evaluate the BDI system, the research team performed diagnostic load tests on seven "typical" bridge structures: three steel-girder bridges with concrete decks, two concrete slab bridges, and two steel-girder bridges with timber decks. In addition, a steel-girder bridge with a concrete deck previously tested and modeled by BDI was investigated for model verification purposes. The tests were performed by attaching strain transducers on the bridges at critical locations to measure strains resulting from truck loading positioned at various locations on the bridge. The field test results were used to develop and validate analytical rating models. Based on the experimental and analytical results, it was determined that bridge tests could be conducted relatively easy, that accurate models could be generated with the BDI software, and that the load ratings, in general, were greater than the ratings, obtained using the codified LFD Method (according to AASHTO Standard Specifications for Highway Bridges).
Resumo:
Integral abutment bridges are constructed without an expansion joint in the superstructure of the bridge; therefore, the bridge girders, deck, abutment diaphragms, and abutments are monolithically constructed. The abutment piles in an integral abutment bridge are vertically orientated, and they are embedded into the pile cap. When this type of a bridge experiences thermal expansion or contraction, horizontal displacements are induced at the top of the abutment piles. The flexibility of the abutment piles eliminates the need to provide an expansion joint at the inside face to the abutments: Integral abutment bridge construction has been used in Iowa and other states for many years. This research is evaluating the performance of integral abutment bridges by investigating thermally induced displacements, strains, and temperatures in two Iowa bridges. Each bridge has a skewed alignment, contains five prestressed concrete girders that support a 30-ft wide roadway for three spans, and involves a water crossing. The bridges will be monitored for about two years. For each bridge, an instrumentation package includes measurement devices and hardware and software support systems. The measurement devices are displacement transducers, strain gages, and thermocouples. The hardware and software systems include a data-logger; multiplexers; directline telephone service and computer terminal modem; direct-line electrical power; lap-top computer; and an assortment of computer programs for monitoring, transmitting, and management of the data. Instrumentation has been installed on a bridge located in Guthrie County, and similar instrumentation is currently being installed on a bridge located in Story County. Preliminary test results for the bridge located in Guthrie County have revealed that temperature changes of the bridge deck and girders induce both longitudinal and transverse displacements of the abutments and significant flexural strains in the abutment piles. For an average temperature range of 73° F for the superstructure concrete in the bridge located in Guthrie County, the change in the bridge length was about 1 118 in. and the maximum, strong-axis, flexural-strain range for one of the abutment piles was about 400 micro-strains, which corresponds to a stress range of about 11,600 psi.
Resumo:
Currently, there is no simple direct screening method for the misuse of blood transfusions in sports. In this study, we investigated whether the measurement of iron in EDTA-plasma can serve as biomarker for such purpose. Our results revealed an increase of the plasma iron level up to 25-fold 6 h after blood re-infusion. The variable remained elevated 10-fold one day after the procedure. A specificity of 100% and a sensitivity of 93% were obtained with a proposed threshold at 45 µg/dL of plasma iron. Therefore, our test could be used as a simple, cost effective biomarker for the screening for blood transfusion misuse in sports. Copyright © 2014 John Wiley & Sons, Ltd.
Resumo:
BACKGROUND: Current bilevel positive-pressure ventilators for home noninvasive ventilation (NIV) provide physicians with software that records items important for patient monitoring, such as compliance, tidal volume (Vt), and leaks. However, to our knowledge, the validity of this information has not yet been independently assessed. METHODS: Testing was done for seven home ventilators on a bench model adapted to simulate NIV and generate unintentional leaks (ie, other than of the mask exhalation valve). Five levels of leaks were simulated using a computer-driven solenoid valve (0-60 L/min) at different levels of inspiratory pressure (15 and 25 cm H(2)O) and at a fixed expiratory pressure (5 cm H(2)O), for a total of 10 conditions. Bench data were compared with results retrieved from ventilator software for leaks and Vt. RESULTS: For assessing leaks, three of the devices tested were highly reliable, with a small bias (0.3-0.9 L/min), narrow limits of agreement (LA), and high correlations (R(2), 0.993-0.997) when comparing ventilator software and bench results; conversely, for four ventilators, bias ranged from -6.0 L/min to -25.9 L/min, exceeding -10 L/min for two devices, with wide LA and lower correlations (R(2), 0.70-0.98). Bias for leaks increased markedly with the importance of leaks in three devices. Vt was underestimated by all devices, and bias (range, 66-236 mL) increased with higher insufflation pressures. Only two devices had a bias < 100 mL, with all testing conditions considered. CONCLUSIONS: Physicians monitoring patients who use home ventilation must be aware of differences in the estimation of leaks and Vt by ventilator software. Also, leaks are reported in different ways according to the device used.
Resumo:
Työn päätavoitteena oli tuoda esiin tärkeimmät julkistamisprosessin tehokkuuteen vaikuttavat tekijät. Tutkimuksessa tarkasteltiin aihetta julkistamisprojektien vetäjän näkökulmasta. Kirjallinen selvitys kattaa keskeisimmät ohjelmistoprosessin, palvelun laadun sekä projektihallinnan teoriat. Kokeellisena aineistona käytettiin asiakkailta ja myynnin sekä käyttöönoton organisaatioilta tullutta palautetta ja asiantuntijahaastatteluita. Case-tuotteena tarkasteltiin suuren kansainvälisen yrityksen jälleenmyymää leikkaussalihallinnan ohjelmistoa. Tärkeimpiä julkistamisprosessin tehokkuuteen vaikuttavia tekijöitä ovat tiekartan ja julkistamispakettien sisällön hallinta, projektin aikataulujen pitäminen, rehellinen ja nopea kommunikaatio myyntikanavaan ja asiakkaille, sekä hyvin toteutettu testaus. Työssä käydään läpi esimerkkistrategioita kehittymiseen näillä alueilla.
Resumo:
Perushyväksymistestaus on oleellinen osa S60 alustan julkaisukandidaatin maturiteetin seurannassa. Perushyväksymistestausta tehdään myös ohjelmiston julkistamiskelpoisuuden varmistamiseksi. Testaustulokset halutaan aina mahdollisimman nopeasti. Lisäksi testaustiimin työmäärä on hiljalleen kasvanut, koska projekteja onenemmän ja korjauksia sisältäviä ja räätälöityjä settejä testataan enemmän. Tässä diplomityössä tutkitaan lyhentäisikö testisetin osan automatisointi testien ajoaikaa ja helpottaisiko se testaajien työtaakkaa. Tarkastelu toteutetaan automatisoimalla osa testisetistä ja kokemuksia esitellään tässä lopputyössä.
Resumo:
Euroopan hiukkastutkimuslaitoksen CERNin rakenteilla olevan LHC-hiukkaskiihdyttimen CMS-koeasema on tarkoitettu erityisesti myonin ilmaisuun. Tässä työssä on esitelty CMS-koeaseman RPC-ilmaisintyypin linkkijärjestelmä ja sen testaamiseen tarkoitetut laitteet sekä laitteiden testaamiseen tarvittavat ohjelmistot. Työssä on selvitetty ohjelmien toimivuus ja keskinäinen yhteensopivuus.
Resumo:
Opinnäytetyö etsii korrelaatiota ohjelmistomittauksella saavutettujen tulosten ja ohjelmasta löytyneiden virheiden väliltä. Työssä käytetään koeryhmänä jo olemassaolevia ohjelmistoja. Työ tutkii olisiko ohjelmistomittareita käyttämällä ollut mahdollista paikallistaa ohjelmistojen ongelmakohdat ja näin saada arvokasta tietoa ohjelmistokehitykseen. Mittausta voitaisiin käyttää resurssien parempaan kohdentamiseen koodikatselmuksissa, koodi-integraatiossa, systeemitestauksessa ja aikataulutuksessa. Mittaamisen avulla nämä tehtävät saisivat enemmän tietoa resurssien kohdistamiseen. Koeryhmänä käytetään erilaisia ohjelmistotuotteita. Yhteistä näille kaikille tuotteille on niiden peräkkäiset julkaisut. Uutta julkaisua tehtäessä, edellistä julkaisua käytetään pohjana, jonka päällekehitetään uutta lähdekoodia. Tämän takia ohjelmistomittauksessa pitää pystyä erottelemaan edellisen julkaisun lähdekoodi uudesta lähdekoodista. Työssä käytettävät ohjelmistomittarit ovat yleisiä ja ohjelmistotekniikassalaajasti käytettyjä mittaamaan erilaisia lähdekoodin ominaisuuksia, joiden arvellaan vaikuttavan virhealttiuteen. Tämän työn tarkoitus on tutkia näiden ohjelmistomittareiden käytettävyyttä koeryhmänä toimivissa ohjelmistoympäristöissä. Käytännön osuus työstä onnistui löytämään korrelaation joidenkinohjelmistomittareiden ja virheiden väliltä, samalla kuin toiset ohjelmistomittarit eivät antaneet vakuuttavia tuloksia. Ohjelmistomittareita käyttämällä näyttää olevan mahdollista tunnistaa virhealttiit kohdat ohjelmasta ja siten parantaa ohjelmistokehityksen tehokkuutta. Ohjelmistomittareiden käyttö tuotekehityksessäon perusteltavaa ja niiden avulla mahdollisesti pystyttäisiin vaikuttamaan ohjelmiston laatuun tulevissa julkaisuissa.
Resumo:
Background and aim of the study: In Switzerland no HIV test is performed without the patient's consent based on a Voluntary Counseling and Testing policy (VCT). We hypothesized that a substantial proportion of patients going through an elective surgery falsely believed that an HIV test was performed on a routine basis and that the lack of transmission of result was interpreted as being HIV negative. Material and method: All patients with elective orthopedic surgery during 2007 were contacted by phone in 2008. A structured questionnaire assessed their belief about routine preoperative blood analysis (glycemia, coagulation capacity, HIV serology and cholesterol) as well as result awareness and interpretation. Variables included age and gender. Analysis were conducted using the software JMP 6.0.3. Results: 1123 patients were included. 130 (12%) were excluded (i.e. unreachable, unable to communicate on the phone, not operated). 993 completed the survey (89%). Median age was 51 (16-79). 50% were female. 376 (38%) patients thought they had an HIV test performed before surgery but none of them had one. 298 (79%) interpreted the absence of result as a negative HIV test. A predictive factor to believe an HIV test had been done was an age below 50 years old (45% vs 33% for 16-49 years old and 50-79 years old respectively, p <0.001). No difference was observed between genders. Conclusion: In Switzerland, nearly 40% of the patients falsely thought an HIV test had been performed on a routine basis before surgery and were erroneously reassured about their HIV status. These results should either improve the information given to the patient regarding preoperative exams, or motivate public health policy to consider HIV opt-out screening, as patients are already expecting it.
Resumo:
Today's business environment has become increasingly unexpected and fast changing because of the global competition. This new environment requires the companies to organize their control differently, e.g. by logistic process thinking. Logistic process thinking in software engineering applies the principles of production process to immaterial products. Processes must be optimized, so that every phase adds value to the customer, and the lead times can be cut shorter to meet the new customer requirements. The purpose of this thesis is to examine and optimize the testing processes of software engineering concentrating on module testing, functional testing and their interface. The concept of logistic process thinking is introduced through production process, value added model and process management. Also theory of testing based on literature is presented, concentrating on module testing and functional testing. The testing processes of the Case Company are presented together with the project models in which they are implemented. The real life practices in module testing and functional testing and their interface are examined through interviews. These practices are analyzed against the processes and the testing theory, through which ideas for optimizing the testing process are introduced. The project world of the Case Company is also introduced together with two example testing projects in different life cycle phases. The examples give a view of how much effort of the project is put in different types of testing.