924 resultados para Ultrasonic transducers.


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work, a computational framework has been proposed to successfully simulate the fibre embedding using ultrasonic consolidation process. The main components of the proposed computational approach are a developed constitutive model and a friction model which are especially suitable for the condition of ultrasonic process. The effect of different process parameters, such as velocity of sonotrode, displacement amplitude of ultrasonic vibration and applied loads are studied. The presented work especially focuses on the quality of the developed weld and the fibre coverage due to the plastic flow around the fibre. The areas of maximum plastic flow predicted by the simulation are confirmed by the EBSD microstructural studies. © 2011 Inderscience Enterprises Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Currently there is no reliable objective method to quantify the setting properties of acrylic bone cements within an operating theatre environment. Ultrasonic technology can be used to determine the acoustic properties of the polymerising bone cement, which are linked to material properties and provide indications of the physical and chemical changes occurring within the cement. The focus of this study was the critical evaluation of pulse-echo ultrasonic test method in determining the setting and mechanical properties of three different acrylic bone cement when prepared under atmospheric and vacuum mixing conditions. Results indicated that the ultrasonic pulse-echo technique provided a highly reproducible and accurate method of monitoring the polymerisation reaction and indicating the principal setting parameters when compared to ISO 5833 standard, irrespective of the acrylic bone cement or mixing method used. However, applying the same test method to predict the final mechanical properties of acrylic bone cement did not prove a wholly accurate approach. Inhomogeneities within the cement microstructure and specimen geometry were found to have a significant influence on mechanical property predictions. Consideration of all the results suggests that the non-invasive and non-destructive pulse-echo ultrasonic test method is an effective and reliable method for following the full polymerisation reaction of acrylic bone cement in real-time and then determining the setting properties within a surgical theatre environment. However the application of similar technology for predicting the final mechanical properties of acrylic bone cement on a consistent basis may prove difficult.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ultrasound absorption spectra of four 1-alkyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide were determined as a function of the alkyl chain length on the cation from 1-propyl- to 1-hexyl- from 293.15 to 323.15 K at ambient pressure. Herein, the ultrasound absorption measurements were carried out using a standard pulse technique within a frequency range from 10 to 300 MHz. Additionally the speed of sound, density and viscosity have been measured. The presence of strong dissipative processes during the ultrasound wave propagation was found experimentally, i.e. relaxation processes in the megahertz range were observed for all compounds over the whole temperature range. The relaxation spectra (both relaxation amplitude and relaxation frequency) were shown to be dependent on the alkyl side chain length of the 1-alkyl-3-methylimidazolium ring. In most cases, a single Debye model described the absorption spectra very well. However, a comparison of the determined spectra with the spectra of a few other imidazolium-based ionic liquids reported in the literature (in part recalculated in this work) shows that the complexity of the spectra increases rapidly with the elongation of the alkyl chain length on the cation. This complexity indicates that both the volume viscosity and the shear viscosity are involved in relaxation processes even in relatively low frequency ranges. As a consequence, the sound velocity dispersion is present at relatively low megahertz frequencies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Esta tese apresenta um sistema de localização baseado exclusivamente em ultrassons, não necessitando de recorrer a qualquer outra tecnologia. Este sistema de localização foi concebido para poder operar em ambientes onde qualquer outra tecnologia não pode ser utilizada ou o seu uso está condicionado, como são exemplo aplicações subaquáticas ou ambientes hospitalares. O sistema de localização proposto faz uso de uma rede de faróis fixos permitindo que estações móveis se localizem. Devido à necessidade de transmissão de dados e medição de distâncias foi desenvolvido um pulso de ultrassons robusto a ecos que permite realizar ambas as tarefas com sucesso. O sistema de localização permite que as estações móveis se localizem escutando apenas a informação em pulsos de ultrassons enviados pelos faróis usando para tal um algoritmo baseado em diferenças de tempo de chegada. Desta forma a privacidade dos utilizadores é garantida e o sistema torna-se completamente independente do número de utilizadores. Por forma a facilitar a implementação da rede de faróis apenas será necessário determinar manualmente a posição de alguns dos faróis, designados por faróis âncora. Estes irão permitir que os restantes faróis, completamente autónomos, se possam localizar através de um algoritmo iterativo de localização baseado na minimização de uma função de custo. Para que este sistema possa funcionar como previsto será necessário que os faróis possam sincronizar os seus relógios e medir a distância entre eles. Para tal, esta tese propõe um protocolo de sincronização de relógio que permite também obter as medidas de distância entre os faróis trocando somente três mensagens de ultrassons. Adicionalmente, o sistema de localização permite que faróis danificados possam ser substituídos sem comprometer a operabilidade da rede reduzindo a complexidade na manutenção. Para além do mencionado, foi igualmente implementado um simulador de ultrassons para ambientes fechados, o qual provou ser bastante preciso e uma ferramenta de elevado valor para simular o comportamento do sistema de localização sobre condições controladas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, an open source solution for measurement of temperature and ultrasonic signals (RF-lines) is proposed. This software is an alternative to the expensive commercial data acquisition software, enabling the user to tune applications to particular acquisition architectures. The collected ultrasonic and temperature signals were used for non-invasive temperature estimation using neural networks. The existence of precise temperature estimators is an essential point aiming at the secure and effective applica tion of thermal therapies in humans. If such estimators exist then effective controllers could be developed for the therapeutic instrumentation. In previous works the time-shift between RF-lines echoes were extracted, and used for creation of neural networks estimators. The obtained estimators successfully represent the temperature in the time-space domain, achieving a maximum absolute error inferior to the threshold value defined for hyperthermia/diathermia applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: : To determine the influence of nebulizer types and nebulization modes on bronchodilator delivery in a mechanically ventilated pediatric lung model. DESIGN: : In vitro, laboratory study. SETTING: : Research laboratory of a university hospital. INTERVENTIONS: : Using albuterol as a marker, three nebulizer types (jet nebulizer, ultrasonic nebulizer, and vibrating-mesh nebulizer) were tested in three nebulization modes in a nonhumidified bench model mimicking the ventilatory pattern of a 10-kg infant. The amounts of albuterol deposited on the inspiratory filters (inhaled drug) at the end of the endotracheal tube, on the expiratory filters, and remaining in the nebulizers or in the ventilator circuit were determined. Particle size distribution of the nebulizers was also measured. MEASUREMENTS AND MAIN RESULTS: : The inhaled drug was 2.8% ± 0.5% for the jet nebulizer, 10.5% ± 2.3% for the ultrasonic nebulizer, and 5.4% ± 2.7% for the vibrating-mesh nebulizer in intermittent nebulization during the inspiratory phase (p < 0.01). The most efficient nebulizer was the vibrating-mesh nebulizer in continuous nebulization (13.3% ± 4.6%, p < 0.01). Depending on the nebulizers, a variable but important part of albuterol was observed as remaining in the nebulizers (jet and ultrasonic nebulizers), or being expired or lost in the ventilator circuit (all nebulizers). Only small particles (range 2.39-2.70 µm) reached the end of the endotracheal tube. CONCLUSIONS: : Important differences between nebulizer types and nebulization modes were seen for albuterol deposition at the end of the endotracheal tube in an in vitro pediatric ventilator-lung model. New aerosol devices, such as ultrasonic and vibrating-mesh nebulizers, were more efficient than the jet nebulizer.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We study the ultrasonic attenuation in layered superconductors using the Green's function formalism. General expressions are derived analytically and then calculated numerically by taking the nearest and next-nearest interactions in a disordered layered superconductor with random hoppings. Our results show huge anisotropics of ultrasonic attenuation in the superconductors and the strong dependence of ultrasonic attenuation on the temperature and the direction of polarization of the sound wave.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Adult rats emit 22 kHz ultrasonic alann calls in aversive situations. This type of call IS a component of defensive behaviour and it functions predominantly to warn conspecifics about predators. Production of these calls is dependent on the central cholinergic system. The laterodorsal tegmental nucleus (LDT) and pedunculopontine tegmental nucleus (PPT) contain largely cholinergic neurons, which create a continuous column in the brainstem. The LDT projects to structures in the forebrain, and it has been implicated in the initiation of 22 kHz alarm calls. It was hypothesized that release of acetylcholine from the ascending LDT terminals in mesencephalic and diencephalic areas initiates 22 kHz alarm vocalization. Therefore, the tegmental cholinergic neurons should be more active during emission of alarm calls. The aim of this study was to demonstrate increased activity of LDT cholinergic neurons during emission of 22 kHz calls induced by air puff stimuli. Immunohistochemical staining of the enzyme choline acetyltransferase identified cell bodies of cholinergic neurons, and c-Fos immunolabeling identified active cells. Double labeled cells were regarded as active cholinergic cells. There were significantly more (p

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ultrasonic vocalizations (USV) are emitted by rats in a number of social situations such as aggressive encounters, during sexual behavior, and during play in young rats, situations which are predominantly associated with strong emotional responses. These USV typically involve two distinct types of calls: 22 kHz calls, which are emitted in aversive situations and 50 kHz calls, which are emitted in non-aversive, appetitive situation. The 50 kHz calls are the focus of the present study and to date both the glutamatergic and the dopaminergic systems have been independently implicated in the production of these 50 kHz calls. The present study was conducted to examine a possible relationship between glutamate (GLU) and dopamine (DA) in mediating 50 kHz calls. It was hypothesized that the dopaminergic system plays a mediating role in 50 kHz calls induced by injections ofGLU into the anterior hypothalamic/preoptic area (AHPOA) in adult rats. A total of 68 adult male rats were used in this study. Rats' USV were recorded and analyzed in five experiments that were designed to test the hypothesis: in experiment 1, rats were treated with systemic amphetamine (AMPH) alone; in experiment 2, intra- AHPOA GLU was pretreated with systemic AMPH; in experiment 3, intra-AHPOA GLU was pretreated with intra-AHPOA AMPH; in experiment 4, rats were treated with high and low doses of intra-AHPOA AMPH only; in experiment 5, rats were treated with systemic haloperidol (HAL) as a pretreatment for intra-AHPOA GLU. Analysis of the results indicated that AMPH has a facilitatory effect on 50 kHz USV and that a relationship between DA and GLU in inducing 50 kHz calls does exist. The effect, however, was only observed when DA receptors were antagonized with HAL and was not seen with systemic AMPH pretreatments of intra-AHPOA GLU. The DAGLU relationship at the AHPOA was unclear.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ultrasonic vocalization plays an important role in intraspecies communication for rats. It has been well demonstrated that rats will emit 22kHz vocalization in stressfiil or threatening situations. Although the neural mechanism underlying vocahzation is not well understood, it is known that chohnergic input to the basal forebrain induces such alarm calls. A number of experiments have found that intracerebral injection of carbachol, a predominantly muscarinic agonist, into die anterior hypothalamic/preoptic area (AH/POA) rehably induces vocalization similar to naturally emitted ultrasonic calls. It has also been shown that carbachol has extensive inhibitory effects on neuronal firing in the same area. This result impUes that the inhibitory effects of carbachol in the AH/POA could trigger vocahzation, and that the GABAergic system could be involved. The purpose of this study is to investigate the effects ofGABA agonists and antagonists on flie production of carbachol induced 22kHz vocalization. The following hypotheses were examined: 1) apphcation ofGABA (a naturally occurring inhibitory neurotransmitter) will have a synergistic effect with carbachol, increasing vocalization; and 2) tiie apphcation ofGABA antagonists (picrotoxin or bicuculline) will reduce caibachol-induced vocalization. A total of sixty rats were implanted with stainless steel guide cannulae in the AH/POA area. After recovery, animals were locally pretreated with 1) GABA (l-40ng), 2) picrotoxin (1 .5^g) or bicuculhne (0.03ng), or 3) sahne; before injection with carbachol (1 .5^g). The resulting vocalization was measured and quantitated. The results indicate that pretreatment with GABA or GABA antagonists had no significant effect on vocalization. Local pretreatment with GABA did not potentiate the vocal response as measured by its duration, latraicy, and total number of calls. Similarly, pretreatment with picrotoxin or bicuculline had no effects on the same measures of vocalization. The results suggest tfiat chohnoceptive neurons involved in the production of alarm calls are not under direct GABAergic control.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rats produce ultrasonic vocalizations that can be categorized into two types of ultrasonic calls based on their sonographic structure. One group contains 22-kHz ultrasonic vocalization (USVs), characterized by relatively constant (flat) frequency with peak frequency ranging from 19 to 28-kHz, and a call duration ranging between 100 – 3000 ms. These vocalization can be induced by cholinomimetic agents injected into the ascending mesolimbic cholinergic system that terminates in the anterior hypothalamic-preoptic area (AH-MPO) and lateral septum (LS). The other group of USVs contains 50-kHz USVs, characterized by high peak frequency, ranging from 39 to 90-kHz, short duration ranging from 10-90 ms, and varying frequency and complex sonographic morphology. These vocalizations can be induced by dopaminergic agents injected into the nucleus accumbens, the target area for the mesolimbic dopaminergic system. 22-kHz USVs are emitted in situations that are highly aversive, such as proximity of a predator or anticipation of a foot shock, while 50 kHz USVs are emitted in rewarding and appetitive situations, such as juvenile play behaviour or anticipation of rewarding electrical brain stimulation. The activities of these two mesolimbic systems were postulated to be antagonistic to each other. The current thesis is focused on the interaction of these systems indexed by emission of relevant USVs. It was hypothesized that emission of 22 kHz USVs will be antagonized by prior activation of the dopaminergic system while emission of 50 kHz will be antagonized by prior activation of the cholinergic system. It was found that injection of apomorphine into the shell of the nucleus accumbens significantly decreased the number of carbachol-induced 22 kHz USVs from both AH-MPO and LS. Injection of carbachol into the LS significantly decreased the number of apomorphine-induced 50 kHz USVs from the shell of the nucleus accumbens. The results of the study supported the main hypotheses that the mesolimbic dopaminergic and cholinergic systems function in antagonism to each other.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rats produce ultrasonic vocalizations that can be categorized into two types of ultrasonic calls based on their sonographic structure. One group contains 22-kHz ultrasonic vocalization (USVs), characterized by relatively constant (flat) frequency with peak frequency ranging from 19 to 28-kHz, and a call duration ranging between 100 – 3000 ms. These vocalization can be induced by cholinomimetic agents injected into the ascending mesolimbic cholinergic system that terminates in the anterior hypothalamic-preoptic area (AH-MPO) and lateral septum (LS). The other group of USVs contains 50-kHz USVs, characterized by high peak frequency, ranging from 39 to 90-kHz, short duration ranging from 10-90 ms, and varying frequency and complex sonographic morphology. These vocalizations can be induced by dopaminergic agents injected into the nucleus accumbens, the target area for the mesolimbic dopaminergic system. 22-kHz USVs are emitted in situations that are highly aversive, such as proximity of a predator or anticipation of a foot shock, while 50 kHz USVs are emitted in rewarding and appetitive situations, such as juvenile play behaviour or anticipation of rewarding electrical brain stimulation. The activities of these two mesolimbic systems were postulated to be antagonistic to each other. The current thesis is focused on the interaction of these systems indexed by emission of relevant USVs. It was hypothesized that emission of 22 kHz USVs will be antagonized by prior activation of the dopaminergic system while emission of 50 kHz will be antagonized by prior activation of the cholinergic system. It was found that injection of apomorphine into the shell of the nucleus accumbens significantly decreased the number of carbachol-induced 22 kHz USVs from both AH-MPO and LS. Injection of carbachol into the LS significantly decreased the number of apomorphine-induced 50 kHz USVs from the shell of the nucleus accumbens. The results of the study supported the main hypotheses that the mesolimbic dopaminergic and cholinergic systems function in antagonism to each other.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Central administration of orexin-A has been shown to activate autonomic arousal in rats, reliably inducing anxiety-like behaviours in the open field. To date, there has yet to be a study investigating the role of orexin-A in the communication of such negative affective state. In the current study, forty-six adult male rats were chronically cannulated and administered orexin-A into the medial preoptic area/anterior hypothalamic area to determine the effect of this neuropeptide on anxiety-like behaviour and the production of 22 kHz aversive ultrasonic vocalizations. It was found that intracerebral administration of orexin-A increased autonomic arousal as measured by a significant increase in fecal boli output, however orexin-A did not significantly affect locomotor activity or induce 22 kHz calling. These data suggest that orexin-A is involved in the regulation of the autonomic aspect of anxiety-like behaviour but not in the vocal communication of such negative affect

Relevância:

20.00% 20.00%

Publicador:

Resumo:

There is extensive evidence that the mesolimbic dopamine system underlies the production of 50 kHz ultrasonic vocalizations in rats. In particular, the shell of the nucleus accumbens is associated with generation of frequency modulated 50 kHz calls (a specific type of 50 kHz call which can be subdivided into various subtypes). There is also evidence that amphetamine administered systemically preferentially increases the proportion of trill and step calls compared to other frequency modulated 50 kHz subtypes. The purpose of this study was to investigate the effect of drug administration route and the role of the nucleus accumbens shell in amphetamine-induced 50 kHz call profile in the rat. Three experiments investigated this by using subcutaneous and intra-accumbens microinjections of amphetamine, as well as procaine (a local anesthetic) blockade of the nucleus accumbens. Ultrasonic vocalizations were recorded digitally from 24 rats and were analysed for sonographic structure based on general call parameters. The results of the three experiments were partially supportive of the hypotheses. Systemic amphetamine was found to induce greater bandwidth in 50 kHz calling compared to spontaneous calls in a vehicle condition. Systemic amphetamine was also found to preferentially increase the proportion of trill and step subtypes compared to vehicle. Moreover, there was no difference in the proportions of 50 kHz subtypes resulting from intracerebral or systemic application of amphetamine. There was, however, a significant difference for bandwidth, with systemic amphetamine inducing greater bandwidth over intraaccumbens application. Procaine blockade of the nucleus accumbens shell paired with subcutaneous amphetamine produced no difference in bandwidth of calls compared with those after a vehicle pre-treatment similarly paired. There was no reduction in the proportions of trill and step 50 kHz subtypes as well, with the procaine condition showing significantly greater proportion of step calls. The results of the study support a role for the iii nucleus accumbens shell in the amphetamine-induced changes on 50 kHz call profile. They also indicate there are more regions and pathways involved in generating 50 kHz calls than the projections from the ventral tegmental area to the nucleus accumbens. The implications of this work are that frequency modulated 50 kHz subtypes may be generated by distinct neurophysiological mechanisms and may represent a profitable avenue for investigating different circuits of 50 kHz call categories in the rat.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The thesis investigated the elastic properties and phase transitions in selected mixed sulphate crystals – Lithium Hydrazinium Sulphate [LiN2H2SO4], Lithium Ammonium Sulphate [LiNH4SO4] and Lithium Potassium Sulphate [LiKSO4] – using ultrasonic technique. The pulse echo overlap technique has been used for measuring ultrasonic velocity and its dependence on temperature along different directions with waves of longitudinal and transverse polarizations. Two major numerical techniques and the corresponding computer programs developed as part of present work are presented in this thesis. All the 9 elastic constants of LHS are determined accurately from ultrasonic measurements and applying misorientation correction refines the constants. Ultrasonic measurements are performed in LAS to determine the elastic constants and to study the low temperature phase transitions. Temperature variation studies of elastic constant of LAS are performed for 6 different modes of propagation for heating and cooling at low temperatures. All the 5 independent elastic constants of LPS is determined using ultrasonic measurements. It is concluded that LPS crystal does not undergo a phase transition near this temperature. A comparison of the three crystals studied shows that LPS has maximum number of phase transitions and LHS has the least number. It is interesting to note that LPS has the simplest formula unit among the three. There is considerable scope for the future work on these crystals and others belonging to the sulphate family.