264 resultados para TECHNETIUM-99M


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aim of the study was to evaluate the influence of an extra corporal perfusion (cardiopulmonary bypass operation - cpb) on activation and biodistribution of Tc-99m labelled granulocytes in pigs with and without inhibition of the granulocytes by a leukocyte inhibition module (LIM). The cpb is often related to an activation of granulocytes resulting in an inflammatory answer. The biological mechanisms are unsolved yet. First trials of our group showed that LIM may inhibit the activation of neutrophils and therefore antagonize a cpb-caused impairment of cardiac function. This study is the continuation of these experiments with a higher number of animals and the focus on scintigraphic imaging. Animals, material, methods: 39 German landrace pigs were subdivided into three groups: group A (control) median sternotomy without cpb, group B with cpb, group C with LIM in addition to cpb. After labelling with Tc-99m-HMPAO autologues granulocytes were reinjected. Subsequently to cpb, the animals underwent scintigraphic imaging. Quantification was performed with ROI evaluation and with tissue samples (section analysis) examined in a well counter. Results:A high uptake of Tc-99m-HMPAO was found in the liver. The count rates in brain, heart, lung, spleen and kidneys were far below. The amount of Tc-99m-activity in the organ related to the half life corrected administered activity [%] was for the tissue samples (group A/B/C): brain 0.01/0.02/0.03; lung 12.1/8.3/11.5; heart 0.35/0.54/0.42; kidney 1.24/0.87/1.02; spleen 4.0/4.0/4.5, liver 16.8/20.9/19.6. The count rates determined by ROI-evaluation of the scintigraphic images related to the total count rate in the image [%] were (group A/B/C): brain 1.1/0.9/1.0; lung 15.6/10.4/12.2; heart 4.0/3.5/3.4; kidney 4.0/2.9/3.2; spleen 7.6/7.7/9.5, liver 23.1/36.7/31.4. A significant difference in the tracer uptake between the groups could neither be detected by scintigraphic imaging nor evaluation of tissue samples. Conclusion: Scintigraphic imaging as well as section analysis showed a comparable biodistribution of the tracer. Therefore, the initial results of our group were not confirmed with a considerably higher number of animals. Neither cpb nor the use of the LIM influenced distribution of Tc-99m-labelled granulocytes in pigs significantly.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: To make individual assessments using automated quantification methodology in order to screen for perfusion abnormalities in cerebral SPECT examinations among a sample of subjects with OCD. Methods: Statistical parametric mapping (SPM) was used to compare 26 brain SPECT images from patients with OCD individually with an image bank of 32 normal subjects, using the statistical threshold of p < 0.05 (corrected for multiple comparisons at the level of individual voxels or clusters). The maps were analyzed, and regions presenting voxels that remained above this threshold were sought. results: Six patients from a sample of 26 OCD images showed abnormalities at cluster or voxel level, considering the criteria described above, which represented 23.07%. However, seven images from the normal group of 32 were also indicated as cases of perfusional abnormality, representing 21.8% of the sample. Conclusion: The automated quantification method was not considered to be a useful tool for clinical practice, for analyses complementary to visual inspection.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: To describe the preoperative upper limb lymphoscintigraphic pattern in women with breast cancer. Methods: Thirty-seven patients undergoing lymphoscintigraphy within 30 days of surgery were investigated. Lymphoscintigraphic studies of 37 upper limbs ipsilateral to surgery and 32 contralateral upper limbs were performed. The examination protocol consisted in obtaining static images of the upper limb in semi-flexion after 10 minutes, and 1 and 2 hours after subcutaneous injection of 1 mCi (37 MBq) of Tc-99m-dextran in the dorsum of the hand. The velocity of axillary lymph node visualization (I, visible at 10 minutes; II, 1 hour; III, 2 hours; and IV, invisible) and degree (intensity) of nodal uptake (a, marked; b, moderate; c,mild; and d, absent) were analyzed. Results: Optimal lymphatic functional pattern (Ia) was observed in four (11%) patients, in the ipsilateral upper limb, and six (19%), in the contralateral upper limb. Worse condition was observed in three (8%) patients (IVd) in the ipsilateral upper limb and two (6%) patients in the contralateral upper limb. The remaining patients showed intermediate states of velocity and uptake intensity. Conclusion: This study found relevant changes in preoperative lymphoscintigraphy, demonstrating preexisting functional differences in the lymphatic system. © 2011 Elsevier Editora Ltda.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Ginecologia, Obstetrícia e Mastologia - FMB

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: Angiogenesis involves many mediators including integrins, and the tripeptide RGD is a target amino acid recognition sequence for many of them. Hindlimb ischemia is a simple and convenient animal model however standardization of the injection procedures in the devascularized and control limb is lacking, thus rendering difficult the interpretation of results. The aim of this investigations was to evaluate neovascularization in a hindlimb murine model by means of 99mTc-HYNIC-ß-Ala-RGD. Methods: 99mTc-HYNIC-RGD analog was prepared using coligands. Ischemia was induced in Wistar rats by double- ligation of the common femoral artery. Radiolabeled RGD was injected after 2h, as well as 1, 3, 5, 7, 10 and 14 days. Uptake was evaluated by planar imaging and biodistribution studies. Results: The highest ratio between ischemia and control was achieved at the 7th day (2.62 ± 0.95), with substantial decrease by the 14th day. For pertechnetate the 7th day ratio was 0.87 ± 0.23. Scintigraphic image confirmed different uptakes. Conclusion: 99mTc-HYNIC-RGD analog concentrated in ischemic tissue by the time of widespread angiogenesis and pertechnetate confirmed reduction in blood flow. In this sense, the protocol can be recommended for ischemic models.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: To evaluate the anatomical and functional renal alterations and the association with post-traumatic arterial hypertension. Methods: The studied population included patients who sustained high grades renal injury (grades III to V) successfully non-operative management after staging by computed tomography over a 16-year period. Beyond the review of medical records, these patients were invited to the following protocol: clinical and laboratory evaluation, abdominal computed tomography, magnetic resonance angiography, DMSA renal scintigraphy, and ambulatory blood pressure monitoring. The hypertensive patients also were submitted to dynamic renal scintigraphy (Tc-99m EC), using captopril stimulation to verify renal vascular etiology. Results: Of the 31 patients, there were thirteen grade III, sixteen grade IV (nine lacerations, and seven vascular lesions), and two grade V injuries. All the patients were asymptomatic and an average follow up post-injury of 6.4 years. None had abnormal BUN or seric creatinine. The percentage of renal volume reduction correlates with the severity as defined by OIS. There was no evidence of renal artery stenosis in Magnetic Resonance angiography (MRA). DMSA scanning demonstrated a decline in percentage of total renal function corresponding to injury severity (42.2 +/- 5.5% for grade III, 35.3 +/- 12.8% for grade IV, 13.5 +/- 19.1 for grade V). Six patients (19.4%) had severe compromised function (< 30%). There was statistically significant difference in the decrease in renal function between parenchymal and vascular causes for grade IV injuries (p < 0.001). The 24-hour ambulatory blood pressure monitoring detected nine patients (29%) with post-traumatic hypertension. All the patients were male, mean 35.6 years, 77.8 % had a familial history of arterial hypertension, 66.7% had grade III renal injury, and average post-injury time was 7.8 years. Seven patients had negative captopril renography. Conclusions: Late results of renal function after conservative treatment of high grades renal injuries are favorable, except for patients with grades IV with vascular injuries and grade V renal injuries. Moreover, arterial hypertension does not correlate with the grade of renal injury or reduction of renal function.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Antimicrobial peptides are present in animals, plants and microorganisms and play a fundamental role in the innate immune response. Gomesin is a cationic antimicrobial peptide purified from haemocytes of the spider Acanthoscurria gomesiana. It has a broad-spectrum of activity against bacteria, fungi, protozoa and tumour cells. Candida albicans is a commensal yeast that is part of the human microbiota. However, in immunocompromised patients, this fungus may cause skin, mucosal or systemic infections. The typical treatment for this mycosis comprises three major categories of antifungal drugs: polyenes, azoles and echinocandins; however cases of resistance to these drugs are frequently reported. With the emergence of microorganisms that are resistant to conventional antibiotics, the development of alternative treatments for candidiasis is important. In this study, we evaluate the efficacy of gomesin treatment on disseminated and vaginal candidiasis as well as its toxicity and biodistribution. Results: Treatment with gomesin effectively reduced Candida albicans in the kidneys, spleen, liver and vagina of infected mice. The biodistribution of gomesin labelled with technetium-99 m showed that the peptide is captured in the kidneys, spleen and liver. Enhanced production of TNF-alpha, IFN-gamma and IL-6 was detected in infected mice treated with gomesin, suggesting an immunomodulatory activity. Moreover, immunosuppressed and C. albicans-infected mice showed an increase in survival after treatment with gomesin and fluconazole. Systemic administration of gomesin was also not toxic to the mice Conclusions: Gomesin proved to be effective against experimental Candida albicans infection. It can be used as an alternative therapy for candidiasis, either alone or in combination with fluconazole. Gomesin's mechanism is not fully understood, but we hypothesise that the peptide acts through the permeabilisation of the yeast membrane leading to death and/or releasing the yeast antigens that trigger the host immune response against infection. Therefore, data presented in this study reinforces the potential of gomesin as a therapeutic antifungal agent in both humans and animals.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Micelles composed of amphiphilic copolymers linked to a radioactive element are used in nuclear medicine predominantly as a diagnostic application. A relevant advantage of polymeric micelles in aqueous solution is their resulting particle size, which can vary from 10 to 100 nm in diameter. In this review, polymeric micelles labeled with radioisotopes including technetium (99mTc) and indium (111In), and their clinical applications for several diagnostic techniques, such as single photon emission computed tomography (SPECT), gamma-scintigraphy, and nuclear magnetic resonance (NMR), were discussed. Also, micelle use primarily for the diagnosis of lymphatic ducts and sentinel lymph nodes received special attention. Notably, the employment of these diagnostic techniques can be considered a significant tool for functionally exploring body systems as well as investigating molecular pathways involved in the disease process. The use of molecular modeling methodologies and computer-aided drug design strategies can also yield valuable information for the rational design and development of novel radiopharmaceuticals.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In der vorliegenden Arbeit werden Entwicklungen zur Optimierung von Selektivität und Effizienz von Resonanzionisations-Laserionenquellen vorgestellt. Mit der Perspektive auf die Anwendungen radioaktiver Ionenstrahlen in der Grundlagenforschung sowie auf Fragestellungen in der Ultraspurenanalytik wurden verschiedene Methoden entwickelt und erprobt: Auf Seiten der Grundlagenforschung wurden zwei komplementäre Ansätze, die Konstruktion von Ionenquellen aus Materialien niedriger Austrittsarbeit und die Weiterentwicklung der Laserionenquelle und -falle LIST umgesetzt. Hierdurch konnte die Selektivität der Resonanzionisation in on-line Tests um einige Gröÿenordnungen verbessert werden. Für die Ultraspurenanalytik wurden speziell angepasste, hocheffiziente Ionenquellen entwickelt. Mit diesen Ionenquellen wurde für die Resonanzionisation von Gallium eine Ionisationseffizienz von 67 % demonstriert, für den Ultraspurennachweis des im Zusammenhang der nuklearen Endlagerung wichtigen Radioisotops 99g-Technetium wurde auf dieser Grundlage eine Nachweisgrenze von weniger als 10^6 Atomen gezeigt.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

ZusammenfassungrnDie vorliegende Arbeit beschreibt Experimente mit einer Apparatur namens Mikro-rnSISAK, die in der Lage ist, eine Flüssig-Flüssig-Extraktion im Mikroliter-Maßstab durchzuführen. Dabei werden zwei nicht mischbare Flüssigkeiten in einer Mikrostruktur emulgiert und anschließend über eine Teflonmembran wieder entmischt.rnIn ersten Experimenten wurden verschiedene Extraktionssysteme für Elemente derrnGruppen 4 und 7 des Periodensystems der Elemente untersucht und die Ergebnisse mit denen aus Schüttelversuchen verglichen. Da die zunächst erreichten Extraktionsausbeuten nicht ausreichend waren, wurden verschiedene Maßnahmen zu deren Verbesserung herangezogen.rnZunächst hat man mit Hilfe eines an die MikroSISAK-Apparatur angelegten Heizelements die dort für die Extraktion herrschende Temperatur erhöht. Dies führte wie erhofft zu einer höheren Extraktionsausbeute.rnDes Weiteren wurde MikroSISAK vom Institut für Mikrotechnik Mainz, welches derrnEntwickler und Konstrukteur der Apparatur ist, durch eine Erweiterung modifiziert, um den Kontakt der beiden Phasen zwischen Mischer und Separationseinheit zu verlängern. Auch dies verbesserte der Extraktionsausbeute.rnNun erschienen die erzielten Ergebnisse als ausreichend, um die Apparatur für online-Experimente an den TRIGA-Reaktor Mainz zu koppeln. Hierfür wurden durch Kernreaktion erzeugte Spaltprodukte des Technetiums MikroSISAK zugeführt, um sie dort abzutrennen und anschließend über ihren Zerfall an einem Detektor nachzuweisen. Neben erfolgreichen Ergebnissen lieferten diese Experimente auch die Belege für die Funktionsfähigkeit eines neuen Entgasers und für die Möglichkeit sowohl diesen als auch ein adäquates Detektorsystem an die MikroSISAK-Apparatur anzuschließen.rnDies schafft die Voraussetzung für die eigentliche Anwendungsidee, die hinter der Entwicklung von MikroSISAK steckt: Die Untersuchung der chemischen Eigenschaften von kurzlebigen superschweren Elementen (SHE) an einem Schwerionenbeschleuniger. Es liegt nahe, solche Experimente für das schwere Homologe des Technetiums, Element 107, Bohrium, ins Auge zu fassen.