914 resultados para System monitoring


Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this work, a system using active RFID tags to supervise truck bulk cargo is described. The tags are attached to the bodies of the trucks and readers are distributed in the cargo buildings and attached to weighs and the discharge platforms. PDAs with camera and support to a WiFi network are provided to the inspectors and access points are installed throughout the discharge area to allow effective confirmations of unload actions and the acquisition of pictures for future audit. Broadband radio equipments are used to establish efficient communication links between the weighs and cargo buildings which are usually located very far from each other in the field. A web application software was especially developed to enable robust communication between the equipments for efficient device management, data processing and reports generation to the operating personal. The system was deployed in a cargo station of a Brazilian seashore port. The obtained results prove the effectiveness of the proposed system.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The success in the adoption of peach integrated production (IP) was evaluated in small orchards of the Parana State. The importance of specific technical accompaniment; points of strangulating in adoption of technology and the classification of the areas to IP conformity were evaluated. The seasons 2005/2006 (without IP orientation) and 2006/2007 (with IP orientation) were compared considering 20 producers who were oriented monthly to attend the minimum requisites. The incidence of peach rust (Tranzschelia discolor) and of brown rot (Monilinia fructicola) in full bloom was evaluated in 2006/2007 and 2007/2008 seasons, as biological parameters to accompany the efficiency of system adoption. After the technical accompaniment in 2007/2008 season, the software APOIA-Novo Rural-PI (APOIA-PI) was applied to measure the conformity to IP in peach orchards. The conformity index of each orchard was compared to the minimum requisite to classify as IP (0.7). The major difficulties in register of field book were: pests monitoring; collect of climate data and the harvest evaluation. The technical accompaniment increased in 60% the conformity in use of field book. In 2007/2008 season, the brown rot incidence increased in some areas, caused by not following IP recommendations. The inadequate management caused the increment in pathogen inoculum, promoting the disease development in peach orchards. The APOIA-PI classified two orchards as good agricultural practices (GAP) (0.7 <= conformity index >= 0.4), two as integrated production (IP) (>= 0.7) and the other orchards had conformity index lower than 0.4.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Brown rot, caused by Monilinia fructicola, is the most widespread disease for organic peach production systems in Brazil. The objective of this study was to determine the favorable periods for latent infection by M. fructicola in organic systems. The field experiment was carried out during 2006, 2007 and 2008 using the cultivar Aurora. After thinning fruits were bagged using white paraffin bags, and the treatments were performed by removing the bags and exposing the fruit for four days to the natural infection during each of seven fruit stages from pit hardening to harvest. Throughout the entire growing season, the conidial density and the weather variables were measured and related to the disease incidence using multiple regression analyses. At the fourth day after harvest in each season, the cumulative disease incidence was assessed, and it ranged from 40 to 98%. The incidence of brown rot on fruit that were exposed during the embryo growing stage was lower than that of unbagged fruit throughout the entire season in 2006 and 2008. The relative humidity and the conidia density were significantly correlated to disease incidence. Based on our results, M. fructicola can infect peaches during any stage of fruit development, and control of the disease must be revised to account for organic peach production systems. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Appropriate ways to monitor the availability and use of illicit drugs were examined. Four methods were tested concurrently: (1) a quantitative survey of injecting drug users, (2) a qualitative key informant study of illicit drug users and professionals working in the drug field, (3) examination of existing sources of survey, health and law enforcement data and (4) an ethnographic study of a high risk group of illicit drug users. The first three methods were recommended for inclusion in an ongoing national monitoring system, enabling the collection of both quantitative and qualitative data on a range of illicit drugs in a relatively brief, quick and cost-effective manner. A degree of convergent validity was also noted among these methods, improving the degree of confidence in drug trends. The importance of injecting drug users as a sentinel population of illicit drug users was highlighted, along with optimal methods for qualitative research.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The increasing emphasis on evidence-based clinical practice has thrown into sharp focus multiple deficiencies in current systems of ethical review. This paper argues that a complete overhaul of systems for ethical oversight of studies involving human subjects is now required as developments in medical, epidemiological and genetic research have outstripped existing structures for ethical supervision. It shows that many problems are now evident and concludes that sequential and piecemeal amendments to present arrangements an inadequate to address these. Ar their core present systems of ethical review still rely on the integrity and judgement of individual investigators. One possible alternative is to train and license research investigators, make explicit their responsibilities and have ethics committees devote much more of their time to monitoring research activity in order to detect those infringing the rules.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dherte PM, Negrao MPG, Mori Neto S, Holzhacker R, Shimada V, Taberner P, Carmona MJC - Smart Alerts: Development of a Software to Optimize Data Monitoring. Background and objectives: Monitoring is useful for vital follow-ups and prevention, diagnosis, and treatment of several events in anesthesia. Although alarms can be useful in monitoring they can cause dangerous user`s desensitization. The objective of this study was to describe the development of specific software to integrate intraoperative monitoring parameters generating ""smart alerts"" that can help decision making, besides indicating possible diagnosis and treatment. Methods: A system that allowed flexibility in the definition of alerts, combining individual alarms of the parameters monitored to generate a more elaborated alert system was designed. After investigating a set of smart alerts, considered relevant in the surgical environment, a prototype was designed and evaluated, and additional suggestions were implemented in the final product. To verify the occurrence of smart alerts, the system underwent testing with data previously obtained during intraoperative monitoring of 64 patients. The system allows continuous analysis of monitored parameters, verifying the occurrence of smart alerts defined in the user interface. Results: With this system a potential 92% reduction in alarms was observed. We observed that in most situations that did not generate alerts individual alarms did not represent risk to the patient. Conclusions: Implementation of software can allow integration of the data monitored and generate information, such as possible diagnosis or interventions. An expressive potential reduction in the amount of alarms during surgery was observed. Information displayed by the system can be oftentimes more useful than analysis of isolated parameters.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The level of fractional exhaled nitric oxide (FENO) is significantly elevated in uncontrolled asthma and decreases after anti-inflammatory therapy The aim of this prospective study was to analyze the behavior of FENO in the follow-up and management of the inflammation in asthmatic pediatric patients treated with inhaled corticosteroids (ICS), compared to sputum cellularity, serum interleukins (IL), and pulmonary function. Twenty-six clinically stable asthmatic children aged from 6 to 18 years, previously treated or not with ICS were included. Following an international consensus (GINA), the patients were submitted to standard treatment with inhaled fluticasone for 3 months according to the severity of the disease. During this period, each patient underwent three assessments at intervals of approximately 6 weeks: Each evaluation consisted of the measurement of FENO, determination of serum interleukins IL-5, IL-10, IL-13, and interferon gamma (INF-gamma), spirometry and cytological analysis of spontaneous or induced sputum. A significant reduction in mean FENO and IL-5, without concomitant changes in FEV1, was observed along the study. There was no significant correlation between FeNO and FEV1 in the three assessments. A significant correlation between FeNO and IL-5 levels was only observed in the third assessment (r = 0.499, P=0.025). In most patients, serum IL-10, IL-13, and INF-gamma concentrations were undetectable throughout the study Sputum samples were obtained spontaneously in 11 occasions and in 56 by induction with 3% hypertonic saline solution (success rate: 50.8%), with 39 (69.9%) of them adequate for analysis. Only two of the 26 patients produced adequate samples in the three consecutive evaluations, which impaired the determination of a potential association between sputum cellularity and FeNO levels throughout the study. In conclusion, among the parameters of this study, it was difficult to perform and to interpret the serial analysis of spontaneous or induced sputum. Serum interleukins, which remained at very low or undetectable levels in most patients, were not found to be useful for therapeutic monitoring, except for IL-5 that seems to present some correlation with levels of FeNO exhaled. Monitoring of the mean FEV1 indicated no significant variations during the treatment, demonstrating that functional stability or the absence of obstruction may not reflect the adequate management of asthma. Serial measurement of FeNO seemed to best reflect the progressive anti-inflammatory action of ICS in asthma.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Gamma and beta radiation emitting radiopharmaceuticals are handled in nuclear medicine services, and in many cases there is only individual monitoring of gamma radiation. In this paper, the results obtained using a wrist dosimeter prototype (CaSO(4):Dy + Teflon pellets) show that the doses for workers occupationally exposed to beta radiation from (153)Sm are not negligible. It is important that this dose is evaluated, and it has to be taken into consideration in the individual monitoring system.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction: The ACCM/PALS guidelines address early correction of paediatric septic shock using conventional measures. In the evolution of these recommendations, indirect measures of the balance between systemic oxygen delivery and demands using central venous or superior vena cava oxygen saturation ( ScvO(2) >= 70%) in a goal-directed approach have been added. However, while these additional goal-directed endpoints are based on evidence-based adult studies, the extrapolation to the paediatric patient remains unvalidated. Objective: The purpose of this study was to compare treatment according to ACCM/PALS guidelines, performed with and without ScvO(2) goal-directed therapy, on the morbidity and mortality rate of children with severe sepsis and septic shock. Design, participants and interventions: Children and adolescents with severe sepsis or fluid-refractory septic shock were randomly assigned to ACCM/PALS with or without ScvO(2) goal-directed resuscitation. Measurements: Twenty-eight-day mortality was the primary endpoint. Results: Of the 102 enrolled patients, 51 received ACCM/PALS with ScvO(2) goal-directed therapy and 51 received ACCM/PALS without ScvO(2) goal-directed therapy. ScvO(2) goal-directed therapy resulted in less mortality ( 28-day mortality 11.8% vs. 39.2%, p = 0.002), and fewer new organ dysfunctions ( p = 0.03). ScvO(2) goal-directed therapy resulted in more crystalloid ( 28 ( 20-40) vs. 5 ( 0-20) ml/kg, p < 0.0001), blood transfusion ( 45.1% vs. 15.7%, p = 0.002) and inotropic ( 29.4% vs. 7.8%, p = 0.01) support in the first 6 h. Conclusions: This study supports the current ACCM/PALS guidelines. Goal-directed therapy using the endpoint of a ScvO(2) = 70% has a significant and additive impact on the outcome of children and adolescents with septic shock.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Quartz Crystal Microbalance (QCM) was used to monitor the mass changes on a quartz crystal surface containing immobilized lectins that interacted with carbohydrates. The strategy for lectin immobilization was developed on the basis of a multilayer system composed of Au-cystamine-glutaraldehyde-lectin. Each step of the immobilization procedure was confirmed by FTIR analysis. The system was used to study the interactions of Concanavalin A (ConA) with maltose and Jacalin with Fetuin. The real-time binding of different concentrations of carbohydrate to the immobilized lectin was monitored by means of QCM measurements and the data obtained allowed for the construction of Langmuir isotherm curves. The association constants determined for the specific interactions analyzed here were (6.4 +/- 0.2) X 10(4) M-1 for Jacalin-Fetuin and (4.5 +/- 0.1) x 10(2) M-1 for ConA-maltose. These results indicate that the QCM constitutes a suitable method for the analysis of lectin-carbohydrate interactions, even when assaying low molecular mass ligands such as disaccharides. Published by Elsevier B.V.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction: Among patients with congestive heart failure (CHF) both obstructive and central sleep apnea (SA) are associated with increased sympathetic activity. However, the day-night pattern of cardiac autonomic nervous system modulation in CHF patients with and without sleep apnea is unknown. Material and methods: Twenty-five CHF patients underwent polysomnography with simultaneous beat-to-beat blood pressure (Portapres), respiration and electrocardiogram monitoring. Patients were divided according to the presence (SA, n=17) and absence of SA (NoSA, n=8). Power spectral analyses of heart rate variability (HRV) and spontaneous baroreflex sensitivity (BRS) were determined in periods with stable breathing while awake at 6 AM, 10 AM, 10 PM, as well as during stage 2 sleep. In addition, muscle sympathetic nerve activity (MSNA) was evaluated at 10 AM. Results: RR variance, low-frequency (LF), high-frequency (HF) powers of HRV, and BRS were significantly lower in patients with SA compared with NoSA in all periods. HF power, a marker of vagal activity, increased during sleep in patients with NoSA but in contrast did not change across the 24-hour period in patients with SA. MSNA was significantly higher in patients with SA compared with NoSA. RR variance, LF and HF powers correlated inversely with simultaneous MSNA (r=-0.64, -0.61, and -0.61 respectively; P < 0.01). Conclusions: Patients with CHF and SA present a reduced and blunted cardiac autonomic modulation across the 24-hour period. These findings may help to explain the increased cardiovascular risk in patients with CHF and SA. (C) 2009 Elsevier Ireland Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Using NONMEM, the population pharmacokinetics of perhexiline were studied in 88 patients (34 F, 54 M) who were being treated for refractory angina. Their mean +/- SD (range) age was 75 +/- 9.9 years (46-92), and the length of perhexiline treatment was 56 +/- 77 weeks (0.3-416). The sampling time after a dose was 14.1 +/- 21.4 hours (0.5-200), and the perhexiline plasma concentrations were 0.39 +/- 0.32 mg/L (0.03-1.56). A one-compartment model with first-order absorption was fitted to the data using the first-order (FO) approximation. The best model contained 2 subpopulations (obtained via the $MIXTURE subroutine) of 77 subjects (subgroup A) and 11 subjects (subgroup B) that had typical values for clearance (CL/F) of 21.8 L/h and 2.06 L/h, respectively. The volumes of distribution (V/F) were 1470 L and 260 L, respectively, which suggested a reduction in presystemic metabolism in subgroup B. The interindividual variability (CV%) was modeled logarithmically and for CL/F ranged from 69.1% (subgroup A) to 86.3% (subgroup B). The interindividual variability in V/F was 111%. The residual variability unexplained by the population model was 28.2%. These results confirm and extend the existing pharmacokinetic data on perhexiline, especially the bimodal distribution of CL/F manifested via an inherited deficiency in hepatic and extrahepatic CYP2D6 activity.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper proposes the creation of an objectively acquired reference database to more accurately characterize the incidence and longterm risk of relatively infrequent, but serious, adverse events. Such a database would be maintained longitudinally to provide for ongoing comparison with new rheumatologic drug safety databases collecting the occurrences and treatments of rare events, We propose the establishment of product-specific registries to prospectively follow a cohort of patients with rheumatoid arthritis (RA) who receive newly approved therapies. In addition, a database is required of a much larger cohort of RA patients treated with multiple second line agents of sufficient size to enable case-controlled determinations of the relative incidence of rare but serious events in the treated (registry) versus the larger disease population, The number of patients necessary for agent-specific registries and a larger patient population adequate to supply a matched case-control cohort will depend upon estimates of the detectability of an increased incidence over background. We suggest a system to carry out this proposal that will involve an umbrella organization. responsible for establishment of this large patient cohort, envisioned to be drawn from around the world.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This work is developed in the context of Ambient Assisted Living (AAL) and has, as main purpose, the development of a mechatronic system that allows caring of bedridden patients with ongoing medical care terminal (MCT), by a single person. This system allows higher autonomy in domiciliary care, safety, comfort and hygiene of bedridden patients. It contributes to a large increase in their quality of life as well as the ease of monitoring by providers of continuous care, which, in many cases, may be the family itself. The product includes an embedded processing interface for acquiring physiological data to support online monitoring. The development of this project was focused on improving the quality of life, autonomy, participation in social life and reducing healthcare costs in the area AAL. The developed societies currently face severe demographic changes: the world is aging at an unprecedented rate. In 2000, about 420 million people, or about 7 percent of the world population were over 65 years old. In 2050, that number will be near 1500 million people, about 16 percent of the world population. This demographic trend will be accompanied by the increase of people with physical limitations. This will impose new challenges for traditional health systems, not only for Portugal but also for all European countries. There is an urgent need to find solutions to improve the lives of people in their preferred environment by increasing their autonomy, self-confidence and mobility. Therefore, in the case of household scenarios, the provision of effective health services is of fundamental importance to the welfare and economic development of each country. This ongoing project aims to develop a mechatronic system to meet the diverse needs, namely: improving life, health care, safety, comfort, and remote monitoring of bedridden person.