896 resultados para SLUDGE DRYING


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: Amorphous drug forms provide a useful method of enhancing the dissolution performance of poorly water-soluble drugs; however, they are inherently unstable. In this article, we have used Flory–Huggins theory to predict drug solubility and miscibility in polymer candidates, and used this information to compare spray drying and melt extrusion as processes to manufacture solid dispersions.
Method:  Solid dispersions were characterised using a combination of thermal (thermogravimetric analysis and differential scanning calorimetry) and spectroscopic (Fourier transform infrared spectroscopy (FTIR) and X-ray diffraction methods. 
Key Findings: Spray drying permitted generation of amorphous solid dispersions to be produced across a wider drug concentration than melt extrusion. Melt extrusion provided sufficient energy for more intimate mixing to be achieved between drug and polymer, which may improve physical stability. It was also confirmed that stronger drug–polymer interactions might be generated through melt extrusion. Remixing and dissolution of recrystallised felodipine into the polymeric matrices did occur during the modulated differential scanning calorimetry analysis, but the complementary information provided from FTIR confirms that all freshly prepared spray-dried samples were amorphous with the existence of amorphous drug domains within high drug-loaded samples. 
Conclusion: Using temperature–composition phase diagrams to probe the relevance of temperature and drug composition in specific polymer candidates facilitates polymer screening for the purpose of formulating solid dispersions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Carbonation and chloride ingress are the two main causes of corrosion in reinforced concrete structures. An investigation to monitor the ingress of chlorides and carbonation during a 9 month wetting and drying exposure regime to simulate conditions in which multiple mode transport mechanisms are active was conducted on a variety of binders. The penetration was evaluated using water and acid soluble chloride profiles, and phenolphthalein indicator. X-ray diffraction was also used to determine the presence of bound chlorides and carbonation. The results indicated that acid extraction of chlorides is quantitatively reliable and practical for assessing penetration. The effect of carbonation on binding capability was observed and the relative quantity of chlorides also showed a correlation with the amount of chlorides bound in the form of Friedel’s salt.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A valorização de diferentes resíduos industriais provenientes dosector de tratamento/revestimento de superfícies metálicas pode ser obtida utilizando-os como matérias-primas na formulação de pigmentos cerâmicos, sintetizados pelo método cerâmico convencional. Neste trabalho avaliou-se a viabilidade de incorporar lamas geradas pelos processos de (i) anodização, ricas em alumínio, (ii) de niquelagem e cromagem de torneiras, usadas como fonte de níquel e crómio, e (iii) da decapagem química de aços de uma trefilaria, ricas em ferro, utilizadas por si só, ou em conjunto com matérias-primas comerciais, para a obtenção depigmentos cerâmicos que coram, de forma estável, diversas matrizes cerâmicas e vítreas. Esta solução assegura ainda a inertização de potenciaisespécies perigosas presentes nos resíduos, resultando produtos inócuospara a saúde pública. Procedeu-se à caracterização de cada resíduo, em termos de composição química e mineralógica, comportamento térmico, grau de toxicidade, distribuição granulométrica, teor de humidade, etc. Verificou-se a constância das características das lamas, recorrendo à análise de lotes recolhidos em momentos distintos. Os resíduos são essencialmente constituídos por hidróxidos metálicos e foram utilizados após secagem e desagregação. No entanto, a lama de anodização de alumínio sofreu um tratamento térmico suplementar a 1400ºC. O método de síntese dos pigmentos englobou as seguintes etapas: (i) doseamento; (ii) homogeneização; (iii) calcinação; (iv) lavagem e moagem.Procedeu-se à caracterização dos pigmentos, avaliando a cor por espectroscopia de reflectância difusae pelo método CIELAB e determinando as características físico-químicas relevantes. Posteriormente, testou-se o seu desempenho em produtos cerâmicos distintos (corpos e vidrados), aferindo o desempenho cromático e a estabilidade. Numa primeira fase, desenvolveram-se e caracterizaram-se tipos distintos de pigmentos: (i) com base na estrutura do corundo (ii) verde Victória deuvarovite (iii) violeta de cassiterite com crómio (iv) pigmento carmim de malaiaíte; (v)pretos e castanhos com base na estrutura da espinela. Aprofundaram-se depois os estudos do pigmento carmim de malaiaítee do pigmento preto com base na estrutura da espinela. O pigmento carmim de malaiaíte, CaSnSiO5:Cr2O3, é formulado coma lama gerada no processo de niquelagem e cromagem. Avaliou-se a influência do teor de lama na temperatura de síntese e na qualidade cromática, em comparação com um pigmento formulado com reagentes puros. O pigmento preto com estrutura de espinela de níquel, crómio e ferro, foii formulado exclusivamente a partir das lamas geradas nos processos de cromagem/niquelagem e de decapagem química do aço. Avaliaram-se as características cromáticas e o grau de inertização dos elementos tóxicospresentes, em função da estequiometria e do tratamento térmico. Estudou-se ainda um novo sistema com base na estrutura da hibonite(CaAl12O19), que permite a obtenção de pigmentos azuis e que utiliza a lama de cromagem e niquelagem. As espécies cromóforas (Ni2+ ou Co2+) assumem coordenação tetraédrica quando substituem os iões Al3+ que ocupam as posições M5 da rede da hibonite. A formação simultânea de anortite permite reduzir a temperatura de síntese.Para além do carácter inovador deste pigmento de dissolução sólida, a qualidade cromática e a sua estabilidade são interessantes. Além disso, os teores de cobalto ou níquel são reduzidosrelativamente aos utilizados em formulações comerciais de pigmentos azuis, o que se traduz em importantes vantagens económicas e ambientais.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thermal degradation and gaseous products evolving from the pyrolysis of sewage sludge, aimed at agricultural soil amendment, were investigated using Thermogravimetric Analysis in conjunction with Fourier Transform Infrared Analysis (TG-FTIR). The materials were studied in temperatures ranging from 30 to 800 ºC. Furthermore infrared spectra of sewage sludge samples were performed as a complementary technique. In parallel the sewage sludge was spiked with ibuprofen in order to test whether the mentioned techniques are able to detect the drug. Thermal analysis showed the range of 200-400ºC as the most characteristic for weight loss, corresponding with the organic matter volatilization, while the range of 500-800ºC was also characteristic and due to the volatilization of carbonates. On the other hand, ibuprofen-spiking tests identified at temperature range (150-250ºC) where the compound totally volatilizes, therefore, in this work, the detection of ibuprofen by TGA was established for concentrations higher than 0.5 g/kg sludge, concentration 102 times higher than the concentrations measured by other authors in regular sewage sludge (Martín, et al., 2010). A correlation has been found between the ibuprofen concentrations in the sludge and the intensity of the absorption bands, both for FT-IR spectra at the maximum emission temperature for ibuprofen (232ºC) as for the FT-IR spectra of the non-pyrolyzed samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tese de doutoramento, Farmácia (Tecnologia Farmacêutica), Universidade de Lisboa, Faculdade de Farmácia, 2014

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Having previously investigated the dispersal by different hand drying methods of a chemical indicator, fungi and bacteria on the hands of users, this new study assessed the potential for viral dispersal. Aims/Objectives: To determine differences between hand drying methods in their capacity to disperse viruses on the hands of users to other occupants of public washrooms and into the washroom environment. Method: A harmless virus was used to artificially contaminate the hands of participants prior to using three different hand drying devices (jet air dryer, warm air dryer, paper towel dispenser). Viral dispersal was assessed at different heights and distances from the hand drying devices and also at different times after use by means of an air sampler. Results: The jet air dryer was shown to produce significantly more dispersal of virus than the warm air dryer or paper towels. After use of the jet air dryer, high numbers of virus were detected at a range of heights with maximum numbers between 0.61 and 1.22 metres. Virus was also detected at distances of up to 3 metres from the jet air dryer and in the air for up to 15 minutes after its use. The warm air dryer and paper towel dispenser produced low or zero viral counts at different heights, different distances and times after use. Conclusion: Jet air dryers have a greater potential than other hand drying methods to disperse viruses on the hands and contaminate other occupants of a public washroom and the washroom environment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The importance of hand hygiene in reducing the spread of pathogens has been long established and this has been highlighted recently in initiatives such as the NHS’s ‘clean your hands’ campaign. However, much of the focus on hand hygiene has concerned effective hand washing; there has been less emphasis on hand drying and its role in hygienic practices. This study aimed to compare three hand drying methods namely paper towels, a warm air dryer and a jet air dryer for their relative ability to disseminate virus particles into the washroom environment during hand drying. A bacteriophage model was used to compare these methods; hands were artificially contaminated with MS2 phage and dried using each device. Both air sampling and contact plates were assessed and a plaque assay was used to quantify virus dissemination. Samples were collected at set times, heights, angles and distances around each device. Both air sampling and contact plate results indicated that the jet air dryer produced significantly more virus dispersal than either paper towels or the warm air dryer in terms of quantity, distance travelled and the time spent circulating in the air around the device and potentially in the washroom environment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background World Health Organization hand hygiene guidelines state that if electric hand dryers are used, they should not aerosolize pathogens. Previous studies have investigated the dispersal by different hand-drying devices of chemical indicators, fungi and bacteria on the hands. This study assessed the aerosolization and dispersal of virus on the hands to determine any differences between hand-drying devices in their potential to contaminate other occupants of public washrooms and the washroom environment. Methods A suspension of MS2, an Escherichia coli bacteriophage virus, was used to artificially contaminate the hands of participants prior to using three different handdrying devices: jet air dryer, warm air dryer, paper towel dispenser. Virus was detected by plaque formation on agar plates layered with the host bacterium. Vertical dispersal of virus was assessed at a fixed distance (0.4 m) and over a range of different heights (0.0 – 1.8 m) from the floor. Horizontal dispersal was assessed at different distances of up to three metres from the hand-drying devices. Virus aerosolization and dispersal was also assessed at different times up to 15 minutes after use by means of air sampling at two distances (0.1 and 1.0 m) and at a distance behind and offset from each of the hand-drying devices. Results Over a range of heights, the jet air dryer was shown to produce over 60 times greater vertical dispersal of virus from the hands than a warm air dryer and over 1300 times greater than paper towels; the maximum being detected between 0.6 and 1.2 metres from the floor. Horizontal dispersal of virus by the jet air dryer was over 20 times greater than a warm air dryer and over 190 times greater than paper towels; virus being detected at distances of up to three metres. Air sampling at three different positions from the hand-drying devices 15 minutes after use showed that the jet air dryer produced over 50-times greater viral contamination of the air than a warm air dryer and over 110-times greater than paper towels. Conclusions Due to their high air speed, jet air dryers aerosolize and disperse more virus over a range of heights, greater distances, and for longer times than other hand drying devices. If hands are inadequately washed, they have a greater potential to contaminate other occupants of a public washroom and the washroom environment. Main messages: Jet air dryers with claimed air speeds of over 600 kph have a greater potential than warm air dryers or paper towels to aerosolize and disperse viruses on the hands of users. The choice of hand-drying device should be carefully considered. Jet air dryers may increase the risk of transmission of human viruses, such as norovirus, particularly if hand washing is inadequate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims To use a MS2 bacteriophage model to compare three hand-drying methods, paper towels (PT), a warm air dryer (WAD) and a jet air dryer (JAD), for their potential to disperse viruses and contaminate the immediate environment during use. Methods and Results Participants washed their gloved hands with a suspension of MS2 bacteriophage and hands were dried with one of the three hand-drying devices. The quantity of MS2 present in the areas around each device was determined using a plaque assay. Samples were collected from plates containing the indicator strain, placed at varying heights and distances and also from the air. Over a height range of 0.15-1.65 m, the JAD dispersed an average of >60 and >1300-fold more plaque-forming units (pfu) compared to the WAD and PT (P <0.0001), respectively. The JAD dispersed an average of >20 and >190-fold more pfu in total compared to WAD and PT at all distances tested up to 3 m (P <0.01), respectively. Air samples collected around each device 15 minutes after use indicated that the JAD dispersed an average of >50 and >100-fold more pfu compared to the WAD and PT (P <0.001), respectively. Conclusions Use of the JAD lead to significantly greater and further dispersal of MS2 bacteriophage from artificially contaminated hands when compared to the WAD and PT. Significance and Impact of Study The choice of hand drying device should be considered carefully in areas where infection prevention concerns are paramount, such as healthcare settings and the food industry.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background World Health Organization and EU hand hygiene guidelines state that if electric hand dryers are used, they should not aerosolize pathogens. Previous studies have investigated the dispersal by different hand-drying devices of chemical indicators, fungi and bacteria on the hands. This study assessed the aerosolization and dispersal of virus on the hands to determine any differences between hand-drying devices in their potential to contaminate other occupants of public washrooms and the washroom environment. Methods A suspension of MS2, an Escherichia coli bacteriophage virus, was used to artificially contaminate the hands of participants prior to using three different hand-drying devices: jet air dryer, warm air dryer, paper towel dispenser. Virus was detected by plaque formation on agar plates layered with the host bacterium. Vertical dispersal of virus was assessed at a fixed distance (0.4 m) and over a range of different heights (0.0 – 1.8 m) from the floor. Horizontal dispersal was assessed at different distances of up to three metres from the hand-drying devices. Virus aerosolization and dispersal was also assessed at different times up to 15 minutes after use by means of air sampling at two distances (0.1 and 1.0 m) and at a distance behind and offset from each of the hand-drying devices. Results Over a range of heights, the jet air dryer was shown to produce over 60 times greater vertical dispersal of virus from the hands than a warm air dryer and over 1300 times greater than paper towels; the maximum being detected between 0.6 and 1.2 metres from the floor. Horizontal dispersal of virus by the jet air dryer was over 20 times greater than a warm air dryer and over 190 times greater than paper towels; virus being detected at distances of up to three metres. Air sampling at three different positions from the hand-drying devices 15 minutes after use showed that the jet air dryer produced over 50-times greater viral contamination of the air than a warm air dryer and over 110-times greater than paper towels. Conclusions Due to their high air speed, jet air dryers aerosolize and disperse more virus over a range of heights, greater distances, and for longer times than other hand drying devices. If hands are inadequately washed, they have a greater potential to contaminate other occupants of a public washroom and the washroom environment. Main messages: Jet air dryers with claimed air speeds of over 600 kph have a greater potential than warm air dryers or paper towels to aerosolize and disperse viruses on the hands of users. The choice of hand-drying device should be carefully considered. Jet air dryers may increase the risk of transmission of human viruses, such as norovirus, particularly if hand washing is inadequate.