969 resultados para Radiation dose reduction
Resumo:
Poly(tetrafluoroethylene-co-perfluoropropyI vinyl ether), PFA, was grafted with styrene from the vapor phase using a simultaneous radiation grafting method. The graft yields were measured as a function of the dose and dose rate and were found to be initially linearly dependent on the dose and independent of the dose rate up to dose rates of similar to3 kGy/h. However, at a dose rate of 6.2 kGy/h, the slope of the yield-grafting time plot decreased. Raman depth profiles of the grafts showed that the polystyrene concentrations were greatest near the surface of the grafted samples and decreased with depth. The maximum penetration depth of the graft depended on the radiation dose for a fixed dose rate. Fmoc-Rink loading tests showed that the grafts displayed superior loading compared to grafts prepared from bulk styrene or from styrene solutions other than methanol.
Resumo:
Actualmente a Tomografia Computorizada (TC) é um dos métodos de diagnóstico por imagem que tem uma maior contribuição para a dose de radiação X recebida pelos pacientes. Pretende-se com este estudo avaliar as doses praticadas em TC e contribuir para o estabelecimento de Níveis de Referência de Diagnóstico (NRD) na região da Grande Lisboa, Portugal. Foram efectuadas medições de dose em 5 equipamentos de TC multidetectores, considerando o abdómen como área anatómica de interesse. Recorreu-se a uma câmara de ionização e a um fantoma para obter o índice de dose de TC (CTDI) e o produto dose-comprimento (DLP), que permitem determinar os NRD. Estes valores foram comparados com os NRD propostos pela Guideline Europeia e com os estudos desenvolvidos em outros países, como o Reino Unido, Grécia e Taiwan. Os resultados revelaram que os valores de NRD obtidos neste estudo (16,7 mGy para o CTDIvol e 436,5 mGy·cm para o DLP) são discrepantes relativamente à Guideline Europeia (±50%), mas muito próximos relativamente aos NRD estabelecidos nos países considerados. Estes valores podem ser eventualmente explicados pelos equipamentos em análise e pela utilização de protocolos de exame adoptados pelos profissionais de Radiologia nas instituições analisadas. ABSTRACT - Nowadays Computed Tomography (CT) is one of the imaging techniques which have a large contribution to radiation dose received by patients. The purpose of this study is to evaluate CT doses and contribute to the establishment of Diagnostic Reference Levels (DRL) in Lisbon, Portugal. Dose measurements on 5 multidetector CT scanners have been performed, considering the abdomen as the anatomic region of interest. All measurements were performed using an ionization chamber and a phantom to obtain the index CT dose (CTDI) and the dose-length product (DLP), which are used to determine DRL. These values were compared not only with European reference dose values but also with DRL studies developed in other countries like United Kingdom, Greece and Taiwan. The results revealed that DRL values obtained in this study (CTDIvol is 16,7 mGy and DLP is 436,5 mGy·cm) have a higher discrepancy to European Guideline (±50%), while the DRL´s of other countries are nearest to values obtained in this study. Those differences may be eventually explained by the type of the evaluated equipments but also by the exam protocols used by the Radiology professionals on the analyzed institutions.
Resumo:
Introdução – A monitorização da exposição ocupacional a doses de radiação ionizante pode ser complementada por dosímetros eletrónicos individuais que permitem uma leitura direta da dose de radiação recebida. Dada a dependência energética e de débito de dose já reportada para estes dosímetros, este trabalho pretende determinar a linearidade da resposta de um dosímetro eletrónico individual e estudar o comportamento da sua resposta em função da energia de radiação e do débito de dose. Metodologia – Para estudar a dependência da energia da radiação do dosímetro eletrónico pessoal Vertec Bleeper Sv procedeu‑se à sua irradiação com um equivalente de dose individual, Hp(10), de 500 μSv de radiação gama do Cobalto – 60 (60C) e Césio – 137 (137Cs) e das qualidades de radiação X da série Narrow (N): N‑30, N‑40, N‑60, N‑80, N‑100 e N‑120. Para investigar a dependência da resposta em função do débito de dose aplicaram‑se à ampola de raios X as intensidades de corrente elétrica de 1 mA, 5 mA, 10 mA, 15 mA e 20 mA. Resultados – Não existe uma relação entre a resposta do detetor e a energia de radiação a que este é exposto. Ocorre uma subestimação superior a 50% na grandeza medida para energias inferiores a 33 keV, mas ostenta uma medida relativamente linear da grandeza Hp(10) para doses inferiores a 100 μSv. Também se constata que, à medida que o débito de dose aumenta, existe uma diminuição na resposta do dosímetro. O menor decréscimo na resposta deste dosímetro eletrónico individual dá‑se para as qualidades de radiação N‑30 (1,1%), N‑40 (4,1%) e N‑120 (20,0%). Conclusão – Verifica‑se que a resposta do dosímetro individual Vertec Bleeper Sv depende fortemente da energia da radiação e do débito de dose. ABSTRACT: Introduction – The measurement of occupational exposure to radiation doses can be completed with an electronic personal dosemeter that allows a direct reading and alarm function of the received radiation dose. Due to the energy and dose rate dependence already reported for this type of dosemeter, it is intended, with this work, to determine the response linearity of an Electronic Personal Dosemeter and to study its response behavior to the dose rate and radiation energy. Methodology – The electronic personal dosemeter Vertec Bleeper Sv energy dependency was evaluated by its irradiation with 500 μSv from the radionuclides Cobalt – 60 (60C) and Cesium – 137 (137Cs) as well as by the radiation qualities of the Narrow (N) series: N‑30, N‑40, N‑60, N‑80, N‑100 e N‑120. To investigate the dose rate dependency, the intensities of electric current of 1 mA, 5 mA, 10 mA, 15 mA and 20 mA were applied to the X‑ray tube. Results – There is no relationship between the response of the detector and the radiation energy. For energies below 33 keV there is an underestimation over 50% of the radiation dose measured but the detector presents a linear response for energies under 100 μSv. A dependency on the dose rate is perceived since as the dose rate increases, the response of the individual monitor decreases. There is a smaller decrease for the radiation qualities of N‑30 (1.1%), N‑40 (4.1%) and N‑120 (20.0%). Conclusion – It is concluded that there is a strong dependence of radiation energy and dose rate on the response of an electronic personal dosemeter.
Resumo:
Mestrado em Radiações Aplicadas às Tecnologias da Saúde. Área de especialização: Proteção contra Radiações.
Resumo:
Mestrado em Radiações Aplicadas às Tecnologias da Saúde - Área de especialização: Proteção Contra Radiações
Resumo:
A importância da radiação ionizante na prática médica, nãoo só como diagnóstico mas também como terapia, ganhou, no último meio século, uma importância fulcral. Devido aos efeitos secundários da radiação ao ser humano, torna-se fundamental definir regras para aumentar a segurança de todos os seus utilizadores, surgindo assim a radioprotecção. Nesse sentido a Comunidade Europeia da Energia Atómica (EURATOM) define directrizes para os países membros da Comunidade Europeia de forma a poder orientá-los nesse processo. Torna-se assim importante registar e monitorizar os valores de dose de radiação num exame radiológico para o aumento de segurança dos pacientes e técnicos. O presente trabalho desenvolvido no âmbito da disciplina anual Dissertação/Projecto/ Estágio Profissional do Mestrado em Computação e Instrumentação Médica teve como objectivo registar esses valores através da comunicação com medidores de doses. A luz do dia-a-dia da Dr. Campos Costa - Consultório de Tomogra a Computarizada S.A, é apresentada nesta tese uma aplicação computacional capaz de obter os valores de dose de um estudo radiológico a um paciente e guardá-los numa base de dados projectada exclusivamente para esse fim. Os resultados obtidos são animadores uma vez que provam ser possível automatizar a monitorização desses valores através de aplicações com ferramentas capazes de auxiliar os responsáveis por essa monitorização em qualquer centro clínico.
Resumo:
In 2012 we were awarded an Erasmus Intensive Programme grant to facilitate OPTIMAX 2013, a three week duration residential summer school held within the UK during August 2013. The summer school helped to further develop student radiographer skills in optimising x-radiation dose and image quality. With a major emphasis on visual techniques to determine image quality, lesion visibility, lesion detection performance and physical measures of image quality (eg signal to noise ratio (SNR)) we conducted controlled laboratory experiments on phantoms using Computed Radiography, CT and Full Field Digital Mammography. Mathematical modelling was used for radiation dose estimation. Sixty seven people from 5 European countries participated. This included 49 PhD, MSc and BSc students. Discipline areas included radiography, physics, biomedical science and nuclear medicine.
Resumo:
Mestrado em Radiações Aplicadas às tecnologias da Saúde
Resumo:
Coronary artery disease (CAD) is currently one of the most prevalent diseases in the world population and calcium deposits in coronary arteries are one direct risk factor. These can be assessed by the calcium score (CS) application, available via a computed tomography (CT) scan, which gives an accurate indication of the development of the disease. However, the ionising radiation applied to patients is high. This study aimed to optimise the protocol acquisition in order to reduce the radiation dose and explain the flow of procedures to quantify CAD. The main differences in the clinical results, when automated or semiautomated post-processing is used, will be shown, and the epidemiology, imaging, risk factors and prognosis of the disease described. The software steps and the values that allow the risk of developingCADto be predicted will be presented. A64-row multidetector CT scan with dual source and two phantoms (pig hearts) were used to demonstrate the advantages and disadvantages of the Agatston method. The tube energy was balanced. Two measurements were obtained in each of the three experimental protocols (64, 128, 256 mAs). Considerable changes appeared between the values of CS relating to the protocol variation. The predefined standard protocol provided the lowest dose of radiation (0.43 mGy). This study found that the variation in the radiation dose between protocols, taking into consideration the dose control systems attached to the CT equipment and image quality, was not sufficient to justify changing the default protocol provided by the manufacturer.
Resumo:
This review aims to identify strategies to optimise radiography practice using digital technologies, for full spine studies on paediatrics focusing particularly on methods used to diagnose and measure severity of spinal curvatures. The literature search was performed on different databases (PubMed, Google Scholar and ScienceDirect) and relevant websites (e.g., American College of Radiology and International Commission on Radiological Protection) to identify guidelines and recent studies focused on dose optimisation in paediatrics using digital technologies. Plain radiography was identified as the most accurate method. The American College of Radiology (ACR) and European Commission (EC) provided two guidelines that were identified as the most relevant to the subject. The ACR guidelines were updated in 2014; however these guidelines do not provide detailed guidance on technical exposure parameters. The EC guidelines are more complete but are dedicated to screen film systems. Other studies provided reviews on the several exposure parameters that should be included for optimisation, such as tube current, tube voltage and source-to-image distance; however, only explored few of these parameters and not all of them together. One publication explored all parameters together but this was for adults only. Due to lack of literature on exposure parameters for paediatrics, more research is required to guide and harmonise practice.
Resumo:
Aim: Optimise a set of exposure factors, with the lowest effective dose, to delineate spinal curvature with the modified Cobb method in a full spine using computed radiography (CR) for a 5-year-old paediatric anthropomorphic phantom. Methods: Images were acquired by varying a set of parameters: positions (antero-posterior (AP), posteroanterior (PA) and lateral), kilo-voltage peak (kVp) (66-90), source-to-image distance (SID) (150 to 200cm), broad focus and the use of a grid (grid in/out) to analyse the impact on E and image quality (IQ). IQ was analysed applying two approaches: objective [contrast-to-noise-ratio/(CNR] and perceptual, using 5 observers. Monte-Carlo modelling was used for dose estimation. Cohen’s Kappa coefficient was used to calculate inter-observer-variability. The angle was measured using Cobb’s method on lateral projections under different imaging conditions. Results: PA promoted the lowest effective dose (0.013 mSv) compared to AP (0.048 mSv) and lateral (0.025 mSv). The exposure parameters that allowed lower dose were 200cm SID, 90 kVp, broad focus and grid out for paediatrics using an Agfa CR system. Thirty-seven images were assessed for IQ and thirty-two were classified adequate. Cobb angle measurements varied between 16°±2.9 and 19.9°±0.9. Conclusion: Cobb angle measurements can be performed using the lowest dose with a low contrast-tonoise ratio. The variation on measurements for this was ±2.9° and this is within the range of acceptable clinical error without impact on clinical diagnosis. Further work is recommended on improvement to the sample size and a more robust perceptual IQ assessment protocol for observers.
Resumo:
Purpose: Pressure ulcers are a high cost, high volume issue for health and medical care providers, having a detrimental effect on patients and relatives. Pressure ulcer prevention is widely covered in the literature, but little has been published regarding the risk to patients in the radiographical setting. This review of the current literature is to identify findings relevant to radiographical context. Methods: Literature searching was performed using Science Direct and Medline databases. The search was limited to articles published in the last ten years to remain current and excluded studies containing participants less than 17 years of age. In total 14 studies were acquired; three were excluded as they were not relevant. The remaining 11 studies were compared and reviewed. Discussion: Eight of the studies used ‘healthy’ participants and three used symptomatic participants. Nine studies explored interface pressure with a range of pressure mat technologies, two studies measured shear (MRI finite element modelling, and a non-invasive instrument), and one looked at blood flow and haemoglobin oxygenation. A range of surfaces were considered from trauma, nursing and surgical backgrounds for their ability to reduce pressure including standard mattresses, high specification mattresses, rigid and soft layer spine boards, various overlays (gel, air filled, foam). Conclusion: The current literature is not appropriate for the radiographic patient and cannot be extrapolated to a radiologic context. Sufficient evidence is presented in this review to support the need for further work specific to radiography in order to minimise the development of PU in at risk patients.
Resumo:
Introduction: Pressure ulcers are a high cost, high volume issue for health and medical care providers, affecting patients’ recovery and psychological wellbeing. The current research of support surfaces on pressure as a risk factor in the development of pressure ulcers is not relevant to the specialised, controlled environment of the radiological setting. Method: 38 healthy participants aged 19-51 were placed supine on two different imaging surfaces. The XSENSOR pressure mapping system was used to measure the interface pressure. Data was acquired over a time of 20 minutes preceded by 6 minutes settling time to reduce measurement error. Qualitative information regarding participants’ opinion on pain and comfort was recorded using a questionnaire. Data analysis was performed using SPSS 22. Results: Data was collected from 30 participants aged 19 to 51 (mean 25.77, SD 7.72), BMI from 18.7 to 33.6 (mean 24.12, SD 3.29), for two surfaces, following eight participant exclusions due to technical faults. Total average pressure, average pressure for jeopardy areas (head, sacrum & heels) and peak pressure for jeopardy areas were calculated as interface pressure in mmHg. Qualitative data showed that a significant difference in experiences of comfort and pain was found in the jeopardy areas (P<0.05) between the two surfaces. Conclusion: A significant difference is seen in average pressure between the two surfaces. Pain and comfort data also show a significant difference between the surfaces, both findings support the proposal for further investigation into the effects of radiological surfaces as a risk factor for the formation of pressure ulcers.
Resumo:
Introdução – A pesquisa de informação realizada pelos estudantes de ensino superior em recursos eletrónicos não corresponde necessariamente ao domínio de competências de pesquisa, análise, avaliação, seleção e bom uso da informação recuperada. O conceito de literacia da informação ganha pertinência e destaque, na medida em que abarca competências que permitem reconhecer quando é necessária a informação e de atuar de forma eficiente e efetiva na sua obtenção e utilização. Objetivo – A meta da Escola Superior de Tecnologia da Saúde de Lisboa (ESTeSL) foi a formação em competências de literacia da informação, fora da ESTeSL, de estudantes, professores e investigadores. Métodos – A formação foi integrada em projetos nacionais e internacionais, dependendo dos públicos-alvo, das temáticas, dos conteúdos, da carga horária e da solicitação da instituição parceira. A Fundação Calouste Gulbenkian foi o promotor financeiro privilegiado. Resultados – Decorreram várias intervenções em território nacional e internacional. Em 2010, em Angola, no Instituto Médio de Saúde do Bengo, formação de 10 bibliotecários sobre a construção e a gestão de uma biblioteca de saúde e introdução à literacia da informação (35h). Em 2014, decorrente do ERASMUS Intensive Programme, o OPTIMAX (Radiation Dose and Image Quality Optimisation in Medical Imaging) para 40 professores e estudantes de radiologia (oriundos de Portugal, Reino Unido, Noruega, Países Baixos e Suíça) sobre metodologia e pesquisa de informação na MEDLINE e na Web of Science e sobre o Mendeley, enquanto gestor de referências (4h). Os trabalhos finais deste curso foram publicados em formato de ebook (http://usir.salford.ac.uk/34439/1/Final%20complete%20version.pdf), cuja revisão editorial foi da responsabilidade dos bibliotecários. Ao longo de 2014, na Escola Superior de Educação, Escola Superior de Dança, Instituto Politécnico de Setúbal e Faculdade de Medicina de Lisboa e, ao longo de 2015, na Universidade Aberta, Escola Superior de Comunicação Social, Instituto Egas Moniz, Faculdade de Letras de Lisboa e Centro de Linguística da Universidade de Lisboa foram desenhados conteúdos sobre o uso do ZOTERO e do Mendeley para a gestão de referências bibliográficas e sobre uma nova forma de fazer investigação. Cada uma destas sessões (2,5h) envolveu cerca de 25 estudantes finalistas, mestrandos e professores. Em 2015, em Moçambique, no Instituto Superior de Ciências da Saúde, decorreu a formação de 5 bibliotecários e 46 estudantes e professores (70h). Os conteúdos ministrados foram: 1) gestão e organização de uma biblioteca de saúde (para bibliotecários); 2) literacia da informação: pesquisa de informação na MEDLINE, SciELO e RCAAP, gestores de referências e como evitar o plágio (para bibliotecários e estudantes finalistas de radiologia). A carga horária destinada aos estudantes incluiu a tutoria das monografias de licenciatura, em colaboração com mais duas professoras do projeto. Para 2016 está agendada formação noutras instituições de ensino superior nacionais. Perspetiva-se, ainda, formação similar em Timor-Leste, cujos conteúdos, datas e carga horária estão por agendar. Conclusões – Destas iniciativas beneficia a instituição (pela visibilidade), os bibliotecários (pelo evidenciar de competências) e os estudantes, professores e investigadores (pelo ganho de novas competências e pela autonomia adquirida). O projeto de literacia da informação da ESTeSL tem contribuído de forma efetiva para a construção e para a produção de conhecimento no meio académico, nacional e internacional, sendo a biblioteca o parceiro privilegiado nesta cultura de colaboração.
Resumo:
Os métodos utilizados pela Medicina moderna no âmbito da Imagem Molecular e na sua capacidade de diagnosticar a partir da “Função do Orgão” em vez da “Morfologia do Orgão”, vieram trazer á componente fundamental desta modalidade da Imagiologia Médica – A Medicina Nuclear – uma importância acrescida, que se tem traduzido num aumento significativo no recurso á sua utilização nas diferentes formas das suas aplicações clínicas. Para além dos aspectos meramente clínicos, que só por si seriam suficientes para ocupar várias dissertações como a presente; a própria natureza desta técnica de imagem, com a sua inerente baixa resolução e tempos longos de aquisição, vieram trazer preocupações acrescidas quanto ás questões relacionadas com a produtividade (nº de estudos a realizar por unidade de tempo); com a qualidade (aumento da resolução da imagem obtida) e, com os níveis de actividade radioactiva injectada nos pacientes (dose de radiação efectiva sobre as populações). Conhecidas que são então as limitações tecnológicas associadas ao desenho dos equipamentos destinados á aquisição de dados em Medicina Nuclear, que apesar dos avanços introduzidos, mantêm mais ou menos inalteráveis os conceitos base de funcionamento de uma Câmara Gama, imaginou-se a alteração significativa dos parâmetros de aquisição (tempo, resolução, actividade), actuando não ao nível das condições técnico-mecânicas dessa aquisição, mas essencialmente ao nível do pós-processamento dos dados adquiridos segundo os métodos tradicionais e que ainda constituem o estado da arte desta modalidade. Este trabalho tem então como objectivo explicar por um lado, com algum pormenor, as bases tecnológicas que desde sempre têm suportado o funcionamento dos sistemas destinados á realização de exames de Medicina Nuclear, mas sobretudo, apresentar as diferenças com os inovadores métodos, que aplicando essencialmente conhecimento (software), permitiram responder ás questões acima levantadas.