856 resultados para REPRODUCIBILITY OF RESULTS
Resumo:
Background: The aim of this study was to compare pelvic floor muscle (PFM) strength using transvaginal digital palpation in healthy continent women in different age groups, and to compare the inter- and intra-rater reliability of examiners performing anterior and posterior vaginal assessments.Methods: We prospectively studied 150 healthy multiparous women. They were distributed into four different groups, according to age range: G1 (n = 37), 30-40 years-old; G2 (n = 39), 41-50 years-old; G3 (n = 39), 51-60 years-old; and G4 (n = 35), older than 60 years-old. PFM strength was evaluated using transvaginal digital palpation in the anterior and posterior areas, by 3 different examiners, and graded using a 5-point Amaro's scale.Results: There was no statistical difference among the different age ranges, for each grade of PFM strength. There was good intra-rater concordance between anterior and posterior PFM assessment, being 64.7%, 63.3%, and 66.7% for examiners A, B, and C, respectively. The intra-rater concordance level was good for each examiner. However, the inter-rater reliability for two examiners varied from moderate to good.Conclusions: Age has no effect on PFM strength profiles, in multiparous continent women. There is good concordance between anterior and posterior vaginal PFM strength assessments, but only moderate to good inter-rater reliability of the measurements between two examiners.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Despite its high incidence, patellofemoral pain etiology remains unclear. No prior study has compared surface electromyography frequency domain parameters and surface electromyography time domain variables, which have been used as a classic analysis of patellofemoral pain. Thirty one women with patellofemoral pain and twenty eight pain-free women were recruited. Each participant was asked to descend a seven step staircase and data from five successful trials were collected. During the task, the vastus medialis and vastus lateralis muscle activities were monitored by surface electromyography. The data were processed and analyzed in four variables of the frequency domain (median frequency, low, medium and high frequency bands) and three time domain variables (Automatic, Cross-correlation and Visual Onset between the vastus medialis and vastus lateralis muscles). Reliability, Receiver Operating Characteristic curves and regression models were performed. The medium frequency band was the most reliable variable and different between the groups for both muscles, also demonstrated the best values of sensitivity and sensibility, 72% and 69% for the vastus medialis and 68% and 62% for the vastus lateralis, respectively. The frequency variables predicted the pain of individuals with patellofemoral pain, 26% for the vastus medialis and 20% for the vastus lateralis, being better than the time variables, which achieved only 7%. The frequency domain parameters presented greater reliability, diagnostic accuracy and capacity to predict pain than the time domain variables during stair descent and might be a useful tool to diagnose individuals with patellofemoral pain.
Resumo:
Stair ascent is an activity that exacerbates symptoms of individuals with patellofemoral pain. The discomfort associated with this activity usually results in gait modification such as reduced knee flexion in an attempt to reduce pain. Although such compensatory strategy is a logical approach to decrease pain, it also reduces the normal active shock absorption increasing loading rates and may lead to deleterious and degenerative changes of the knee joint. Thus, the aims of this study were (i) to investigate whether there is reduced knee flexion in adults with PFP compared to healthy controls; and (ii) to analyze loading rates in these subjects, during stair climbing. Twenty-nine individuals with patellofemoral pain and twenty-five control individuals (18-30years) participated in this study. Each subject underwent three-dimensional kinematic and kinetic analyses during stair climbing on two separate days. Between-groups analyses of variance were performed to identify differences in peak knee flexion and loading rates. Intraclass correlation coefficient was performed to verify the reliability of the variables. On both days, the patellofemoral pain group demonstrated significantly reduced peak knee flexion and increased loading rates. In addition, the two variables obtained high to very high reliability. Reduced knee flexion during stair climbing as a strategy to avoid anterior knee pain does not seem to be healthy for lower limb mechanical distributions. Repeated loading at higher loading rates may be damaging to lower limb joints.
Resumo:
A montmorillonite from Wyoming-USA was used to prepare an organo-clay complex, named 2-thiazoline-2-thiol-hexadecyltrimethylammonium-clay (TZT-HDTA-clay), for the purpose of the selective adsorption of the heavy metals ions and possible use as a chemically modified carbon paste electrode (CMCPE). Adsorption isotherms of Hg 2+, Pb 2+, Cd 2+, Cu 2+, and Zn 2+ from aqueous solutions as a function of the pH were studied at 298 K. Conditions for quantitative retention and elution were established for each metal by batch and column methods. The organo-clay complex was very selective to Hg(II) in aqueous solution in which other metals and ions were also present. The accumulation voltammetry of Hg(II) was studied at a carbon paste electrode chemically modified with this material. The mercury response was evaluated with respect to the pH, electrode composition, preconcentration time, mercury concentration, cleaning solution, possible interferences and other variables. A carbon paste electrode modified by TZT-HDTA-clay showed two peaks: one cathodic peak at about 0.0 V and an anodic peak at 0.25 V, scanning the potential from -0.2 to 0.8 V (0.05 M KNO 3 vs. Ag/AgCl). The anodic peak at 0.25 V presents excellent selectivity for Hg(II) ions in the presence of foreign ions. The detection limit was estimated as 0.1 μg L -1. The precision of determination was satisfactory for the respective concentration level. 2005 © The Japan Society for Analytical Chemistry.
Resumo:
Since there was no Portuguese questionnaire to evaluate cutaneous allodynia, which has been pointed out as a risk factor of migraine, we aimed to perform the cross-cultural adaptation of the 12 item Allodynia Symptom Checklist for the Brazilian population and to test its measurement properties. It consisted in six stages: translation, synthesis, back translation, revision by a specialist committee, pretest and submission the documents to the committee. In the pretest stage, the questionnaire was applied to 30 migraineurs of both sexes, who had some difficulty in understanding it. Thus, a second version was applied to 30 additional subjects, with no difficulties being reported. The mean filling out time was 3'36", and the internal consistency was 0.76. To test reproducibility, 15 other subjects filled out the questionnaire at two different times, it was classified as moderate (weighted kappa=0.58). We made available to Brazilian population an easy, quick and reliable questionnaire.
Resumo:
The assessment of adenoids by x-ray imaging has been the topic of heated debate, but few studies have looked into the reliability of most existing radiographic parameters. Objective: This study aims to verify the intra-examiner and inter-examiner reproducibility of the adenoid radiographic assessment methods. Materials and Methods: This is a cross-sectional case series study. Forty children of both genders aged between 4 and 14 were enrolled. They were selected based on complaints of nasal obstruction or mouth breathing and suspicion of pharyngeal tonsil hypertrophy. Cavum x-rays and orthodontic teleradiographs were assessed by two examiners in quantitative and categorical terms. Results: All quantitative parameters in both x-ray modes showed excellent intra and inter-examiner reproducibility. Relatively better performance was observed in categorical parameters used in cavum x-ray assessment by C-Kurien, C-Wang, C-Fujioka, and C-Elwany over C-Cohen and C-Ysunza. As for orthodontic teleradiograph grading systems, C-McNamara has been proven to be more reliable than C-Holmberg. Conclusion: Most instruments showed adequate reproducibility levels. However, more research is needed to properly determine the accuracy and viability of each method.
Resumo:
Objective To evaluate the intra- and interobserver reliability of assessment of three-dimensional power Doppler (3D-PD) indices from single spherical samples of the placenta. Methods Women with singleton pregnancies at 2440 weeks' gestation were included. Three scans were independently performed by two observers; Observer 1 performed the first and third scan, intercalated by the scan of Observer 2. The observers independently analyzed the 3D-PD datasets that they had previously acquired using four different methods, each using a spherical sample: random sample extending from basal to chorionic plate; random sample with 2 cm3 of volume; directed sample to the region subjectively determined as containing more color Doppler signals extending from basal to chorionic plate; or directed sample with 2 cm3 of volume. The vascularization index (VI), flow index (FI) and vascularization flow index (VFI) were evaluated in each case. The observers were blinded to their own and each other's results. Additional evaluation was performed according to placental location: anterior, posterior and fundal or lateral. Intra- and interobserver reliability was assessed by intraclass correlation coefficients (ICC). Results Ninety-five pregnancies were included in the analysis. All three placental 3D-PD indices showed only weak to moderate reliability (ICC < 0.66 and ICC < 0.48, intra- and interobserver, respectively). The highest values of ICC were observed when using directed spherical samples from basal to chorionic plate. When analyzed by placental location, we found lower ICCs for lateral and fundal placentae compared to anterior and posterior ones. Conclusion Intra- and interobserver reliability of assessment of placental 3D-PD indices from single spherical samples in pregnant women greater than 24 weeks' gestation is poor to moderate, and clinical usefulness of these indices is likely to be limited. Copyright (c) 2012 ISUOG. Published by John Wiley & Sons, Ltd.
Resumo:
[EN]This work presents the measurements made to define the temperature−composition curves for a set of binary systems composed of several pyridinium-based ionic liquids (ILs) [bpy][BF4] and [bYmpy][BF4] (Y = 2,3,4) with mono- and dihaloalkanes (Cl and Br) in the temperature interval [280−473] K and at atmospheric pressure. With the exception of the short chain dichloroalkanes (1,1- and 1,2-), all the compounds present some degree of immiscibility with the ionic liquids selected.
Resumo:
Conventional time-domain optical coherence tomography (OCT) has become an important tool for following dry or exudative age-related macular degeneration (AMD). Fourier-domain three-dimensional (3D) OCT was recently introduced. This study tested the reproducibility of 3D-OCT retinal thickness measurements in patients with dry and exudative AMD.
Resumo:
In this study we sought to evaluate the reproducibility of sensory nerve conduction studies (NCS) using ultrasound-guided needle positioning (USNP).
Resumo:
Although a history of previous acute mountain sickness (AMS) is commonly used for providing advice and recommending its prophylaxis during subsequent exposure, the intraindividual reproducibility of AMS during repeated high-altitude exposure has never been examined in a prospective controlled study.